Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flux Filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

New approaches to some methodological problems of meteor science

Several low cost approaches to continuous radioscatter monitoring of the incoming meteor flux are described. Preliminary experiments were attempted using standard time frequency stations WWVH and CHU (on frequencies near 15 MHz) during nighttime hours. Around-the-clock monitoring using the international standard aeronautical beacon frequency of 75 MHz was also attempted. The techniques are simple and can be managed routinely by amateur astronomers with relatively little technical expertise. Time series analysis can now be performed using relatively inexpensive microcomputers. Several algorithmic approaches to the analysis of meteor rates are discussed. Methods of obtaining optimal filter predictions of future meteor flux are also discussed.

Meisel, David D.↗

Thermographic detection of cracks in thin sheets

A thermographic inspection technique for crack detection based on a 2D filter convolved with the thermal temperature images is presented. The filter is designed to approximate operating on the temperature images with a Laplacian operator. This operation yields an image which approximates changes in the heat flux in a thin plate. This filtering method results in an enhanced contrast due to the presence of cracks. Measurements have been performed on samples with fabricated electrical discharge machining (EDM) notches (both through-the-thickness and surface notches) and closed fatigue cracks around rivets. It is shown that the technique is effective for the detection of various crack lengths down to the resolution limits of the imager used.

Cramer, K. E.↗

CERES ERBE-like Instantaneous TOA Estimates (ES-8) in HDF (CER_ES8_Aqua-FM3_Edition2)

The ES-8 archival data product contains a 24-hour, single-satellite, instantaneous view of scanner fluxes at the top-of-atmosphere (TOA) reduced from spacecraft altitude unfiltered radiances using Earth Radiation Budget Experiment (ERBE) scanner Inversion algorithms and the ERBE shortwave (SW) and longwave (LW) Angular Distribution Models (ADMs). The ES-8 also includes the total (TOT), SW, LW, and window (WN) channel radiometric data; SW, LW, and WN unfiltered radiance values; and the ERBE scene identification for each measurement. These data are organized according to the CERES 3.3-second scan into 6.6-second records. As long as there is one valid scanner measurement within a record, the ES-8 record will be generated. The following CERES ES8 data sets are currently available: CER_ES8_TRMM-PFM_Edition1 CER_ES8_TRMM-PFM_Edition2 CER_ES8_TRMM-PFM_Transient-Ops2 CER_ES8_Terra-FM1_Edition1 CER_ES8_Terra-FM2_Edition1 CER_ES8_Terra-FM1_Edition2 CER_ES8_Terra-FM2_Edition2 CER_ES8_Aqua-FM3_Edition1 CER_ES8_Aqua-FM4_Edition1 CER_ES8_Aqua-FM3_Edition2 CER_ES8_Aqua-FM4_Edition2 CER_ES8_Aqua-FM3_Edition1-CV CER_ES8_Aqua-FM4_Edition1-CV CER_ES8_Terra-FM1_Edition1-CV CER_ES8_Terra-FM1_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1997-12-27; Stop_Date=2005-12-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 day; Temporal_Resolution_Range=Daily - < Weekly].

LONGWAVE FLUX↗

Quantitative Characterization of Hyper-Local Atmospheric Greenhouse Gas Sources

Atmospheric greenhouse gas (GHG) emissions are often characterized using stationary, tower-based sensors. Ground based sensors reside in the turbulent boundary layer and are subject to intense concentration impulses from hyper-local (<100m) point sources of emissions. These high frequency spikes are often filtered out in broader emission flux studies, losing valuable information about how hyper-local sources influence receptors. In this study, we investigated how empirical atmospheric data can be used to locate and quantify a concurrently measured hyper-local point source in a dense urban setting. An eddy covariance style tower and a low-cost sensor tower were deployed in various locations around an urban, hyper-local CO2/CH4 emissions source (a continuously measured restaurant exhaust vent). A model using different processing and statistical techniques was built to examine the most effective procedures for source isolation, directional location, and emission quantification. Using excess concentrations above a minimum baseline, we identify the source using bivariate polar plots and quantify the relationship between source size, receptor distance, and statistical proxies. Furthermore, we find that varying statistical thresholds allows for identification of less influential sources which are drowned out by larger or closer sources. Finally, we show that large sources can be effectively characterized using low-cost sensors, a valuable outcome informing how networks for monitoring larger areas could be implemented. This work may provide a basis for source identification and monitoring protocols for networks that feature sensors influenced by hyper-local point sources, subject to site-specific assumptions.

54 ENVIRONMENTAL SCIENCES↗

Improving bioenergy recovery from municipal wastewater with a novel cloth-filter anaerobic membrane bioreactor

Anaerobic membrane bioreactors (AnMBR) have been used for treating high-strength industrial wastewater at full-scale and the potential to use them for mainstream municipal wastewater treatment presents an important opportunity to turn energy-intensive plants into net-energy producers. However, several limitations of the AnMBR technology have prevented their adoption in the municipal wastewater industry, namely, high membrane cleaning energy demand and low membrane flux. This study demonstrated a novel AnMBR configuration that uses a commercially available cloth filter technology to address the key limitations of cleaning energy and membrane flux. The cloth filter anaerobic membrane bioreactor (CFAnMBR) is comprised of an anaerobic fixed-film bioreactor coupled with a cloth filter membrane with nominal pore size of 5 µm. The pilot CFAnMBR was operated for 150 days through the winter at a municipal wastewater plant in central Illinois (minimum/average influent temperature 5/13°C). The CFAnMBR increased membrane flux by more than 2 orders of magnitude (3,649 ± 1,246 L per meter squared per hour) and reduced cleaning energy demand by 78%—92% (0.0085 kWh/m 3 ) relative to previously reported AnMBR configurations. With the CFAnMBR, average chemical oxygen demand and total suspended solids removal were 66% and 91%, respectively, and were shown to be increased up to 88% and 96% by in-line coagulant dosing with ferric chloride. Average headspace methane yield was 154 mL CH 4 /g COD removed by the end of the study period with influent temperatures of 11°C± 4°C. The CFAnMBR resolves major limitations of AnMBR technology by employing a commercially-available technology already used for other municipal wastewater treatment applications.

59 BASIC BIOLOGICAL SCIENCES↗

Calibration of the NEAR XRS Solar Monitor

The NEAR-Shoemaker X-ray spectrometer measured elemental abundance ratios for six elements (Mg, Al, Si, S, Ca, Fe) on the surface of 433 Eros by remote-sensing x-ray fluorescence spectroscopy (1,2). The fluorescent x-rays are excited by x-rays from the solar corona. Therefore, accurate knowledge of the incident solar spectrum was critically important to interpreting the fluorescence spectra received by the NEAR detectors in terms of elemental ratios on the asteroid's surface. NEAR, therefore, carried two additional X-ray spectrometers dedicated to monitoring the solar spectrum between 1 and 10 keV. One of these, a Si PIN photodiode, failed prior to orbit insertion. The second consisted of a gas-filled proportional counter similar to the asteroid-pointing detectors, but covered by a graded filter (3) intended to attenuate the incoming solar flux and increase the dynamic range of the detector. Unfortunately, the response of this filter as a function of solar incidence angle was not adequately determined in the laboratory prior to launch. The response function had to be calculated from the assumed properties of the graded filter.

Lim, L. F.↗

AmeriFlux US-GL1 Stannard Rock

This is the AmeriFlux version of the carbon flux data for the site US-GL1 Stannard Rock. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris↗

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana↗

CERES ERBE-like Instantaneous TOA Estimates (ES-8) in HDF (CER_ES8_Terra-FM1_Edition1-CV)

The ES-8 archival data product contains a 24-hour, single-satellite, instantaneous view of scanner fluxes at the top-of-atmosphere (TOA) reduced from spacecraft altitude unfiltered radiances using Earth Radiation Budget Experiment (ERBE) scanner Inversion algorithms and the ERBE shortwave (SW) and longwave (LW) Angular Distribution Models (ADMs). The ES-8 also includes the total (TOT), SW, LW, and window (WN) channel radiometric data; SW, LW, and WN unfiltered radiance values; and the ERBE scene identification for each measurement. These data are organized according to the CERES 3.3-second scan into 6.6-second records. As long as there is one valid scanner measurement within a record, the ES-8 record will be generated. The following CERES ES8 data sets are currently available: CER_ES8_TRMM-PFM_Edition1 CER_ES8_TRMM-PFM_Edition2 CER_ES8_TRMM-PFM_Transient-Ops2 CER_ES8_Terra-FM1_Edition1 CER_ES8_Terra-FM2_Edition1 CER_ES8_Terra-FM1_Edition2 CER_ES8_Terra-FM2_Edition2 CER_ES8_Aqua-FM3_Edition1 CER_ES8_Aqua-FM4_Edition1 CER_ES8_Aqua-FM3_Edition2 CER_ES8_Aqua-FM4_Edition2 CER_ES8_Aqua-FM3_Edition1-CV CER_ES8_Aqua-FM4_Edition1-CV CER_ES8_Terra-FM1_Edition1-CV CER_ES8_Terra-FM1_Edition1-CV. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1997-12-27; Stop_Date=2006-09-30] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 day; Temporal_Resolution_Range=Daily - < Weekly].

TOTAL FILTERED RADIANCE↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

Inferring Cloud Properties from Passive Solar Sensors

The most common approach for retrieving cloud optical depth from ground-based observations uses downwelling fluxes measured by pyranometers and Multi-Filter Rotating Shadowband Radiometers (MFRSR). The key element in both retrieval techniques is the one-to-one mapping of the "observed" fluxes into cloud optical depth through plane-parallel radiative transfer. Both methods are expected to work well only for completely overcast clouds giving an effective optical depth for the whole sky. To infer cloud optical depth locally one can assume to use a narrow-field-of view radiometer that measures radiances instead of fluxes. However, lack of one-to-one relationships between radiance and cloud optical depth, prevents the direct use of radiances either. Here we discuss a new method for retrieving cloud optical depth from ground-based measurements of zenith radiance in the RED and near infrared (NIR) spectral regions. In addition to an algebraic combinations of spectral radiances such as Normalized Difference Cloud Index (NDCI) that largely removes nonuniqueness and the radiative effects of cloud inhomogeneity but can result in poor retrievals due to its insensitivity to cloud fraction, both RED and NIR radiances as points on the "RED vs. NIR" plane are proposed to be used for retrieval. The proposed retrieval method is applied to a multi- channel sunphotometer (as a part of AERONET) measurements at the ARM site in Oklahoma. The results of retrieval are compared with the ones from Microwave Radiometer (MWR) and MFRSR. In addition to cloud optical depth, the new retrieval method also infers a "radiatively effective" cloud fraction.

Marshak, A.↗

Sampling errors in the vertical fluxes of potential temperature and moisture measured by aircraft during FIFE

This paper contributes to understanding the particular problems encountered during FIFE 87 as a result of utilizing relatively short (15 km) averaging lengths for the flux estimates. The implications of employing data that had been high-pass filtered with a five-km cutoff wavelength for flux estimates are also investigated. It is found that a 15-km run length is just adequate for low-level flux estimates as long as the runs are crosswind.

Grossman, Robert L.↗

On the effects of filtering on convective-core statistics

Analysis of convective events north of Australia during the equatorial Monsoon Experiment (EMEX) reinforces accumulating evidence that convective cores over the tropical ocean are weak, with small diameters and vertical velocities. Superposition of smaller-scale turbulence on the convective core signal could yield artificially small cores, and thus produce sampling bias by aircraft. To investigate this potential source of bias, a side-by-side analysis of filtered and unfiltered vertical velocity data was performed while investigating the EMEX convective cores. Data were collected by the NOAA P3 and NCAR Electra using filtered (Graham filter) and non-filtered cores. The effects of filtering vertical velocity data to identify updraft and downdraft cores were noticeable but smaller than expected. Updraft cores had a vertical velocity greater than 1 m/sec for at least 500 m, and downdraft cores were defined analogously so that the filter eliminated events with less than a 500 m apparent diameter. Median and 10 percent core diameters were increased by 20-25 percent at most, with larger increases at higher levels (fewer small events). The maximum vertical velocity was changed only by changing the individual events in the distribution, but changes were detectable. At the lower levels, where many small, weak cores are introduced by filtering, average vertical velocity for the updraft cores was lowered by up to around 10 percent. Mass flux was changed the least, since diameter and mean vertical velocity respond to filtering in opposite ways. The filtering procedure increased total mass flux slightly due to inclusion of more upward moving air into the sample.

Lemone, Margaret A.↗

Airborne photometric observations between 1.25 and 3.25 microns of late-type stars

The stars Alpha Aur (G5 III + G0 III), Alpha Boo (K2 IIIp), Alpha Ori (M1-M2 Ia-Ib), Alpha Sco (M1.5 Iab), Mu Gem (M3 III), and Alpha Her (M5 Ib-II) have been observed using interference filters in five photometric bands between 1.25 and 3.25 microns during seven flights with NASA's Lear Jet Infrared Observatory. The filters were designed to measure molecular features, primarily from CN and CO, and continuum fluxes. By calibrating the photometer in the laboratory against a stabilized blackbody source, relative flux curves have been derived. The energy distributions and the strength of molecular features are discussed. The most interesting result obtained is that the fluxes from Mu Gem and Alpha Her in the filter centered at 3.25 microns seem to be depressed by at least some tenths of a magnitude. Tentatively this depression is proposed to be due to the wings of the two vibration-rotation bands (about 2.7 microns) of hot water vapor. Since water vapor is an important opacity source and its abundance is a sensitive C/O indicator, the proposed interpretation makes renewed efforts to detect water bands in early M stars highly desirable.

Nordh, H. L.↗

CERES Clouds and Radiative Swath (CRS) data in HDF. (CER_CRS_Terra-FM2-MODIS_Edition2A

The Clouds and Radiative Swath (CRS) product contains one hour of instantaneous Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The CRS contains all of the CERES SSF product data. For each CERES footprint on the SSF the CRS also contains vertical flux profiles evaluated at four levels in the atmosphere: the surface, 500-, 70-, and 1-hPa. The CRS fluxes and cloud parameters are adjusted for consistency with a radiative transfer model and adjusted fluxes are evaluated at the four atmospheric levels for both clear-sky and total-sky. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2001-10-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

CLOUD LAYER AREA↗

Evaporation/SST Sensitivity Over the Tropical Oceans During ENSO Events as Estimated from the da Silva, Young, Levitus Surface Marine Data Set

The da Silva, Young and Levitus Surface Marine Atlas, based on observations from the Comprehensive Ocean Atmosphere Data Set (COADS) Release 1, has been used to investigate the relationship between evaporation and sea-surface temperature (SST) over the global oceans. For the period 1950 to 1987 SST, surface latent heat flux, and other related variables have been filtered to minimize data uncertainties and to focus upon interannual variations associated with warm (El Nino) and cold (La Nina) ENSO events. Compositing procedures have enabled identification of systematic variations in latent heat fluxes accompanying these events and the relationship to spatial anomalies in ocean surface wind speed and humidity. The evaporation response associated with ENSO sea surface temperature (SST) variability is systematic in nature and composed of offsetting contributions from the surface wind and humidity variations. During warm events exceeding 1.0 S.D. delta SST, increases in the surface humidity deficit, delta(qs-qa), between the surface and 2m height dominate regions of positive SST anomalies and lead to increases in evaporation of almost 2 Wm (exp -2) at deltaSST = 0.23 K. Despite the increases in specific humidity, relative humidity decreases slightly in regions of elevated SSTs. For the most part, variations in wind speed are consistent with previous investigations. Weakening of the equatorial easterlies (and generation of westerlies) between 160 degrees E and 140 degrees W dominates during the early phases of warm events. Elevated wind speeds in adjacent subtropical regions and in the eastern equatorial Pacific subsequently develop too. The net contribution of these winds, which reflect adjustments in Hadley and Walker circulation components is toward reduced evaporation. Results for cold periods are approximately similar, but opposite in sign to warm events, though evidence of different temporal evolution is noted.

Robertson, F. R.↗

Wind enhanced planetary escape: Collisional modifications

The problem of thermal escape is considered in which both the effects of thermospheric winds at the exobase and collisions below the exobase are included in a Monte Carlo calculation. The collisions are included by means of a collisional relaxation layer of a background gas which models the transition region between the exosphere and the thermosphere. The wind effects are considered in the limiting cases of vertical and horizontal flows. Two species are considered: terrestrial hydrogen and terrestrial helium. In the cases of terrestrial hydrogen the escape fluxes were found to be strongly filtered or throttled by collisions at high exospheric temperatures. The model is applied to molecular hydrogen diffusing through a methane relaxation layer under conditions possible on Titan. The results are similar to the case of terrestrial hydrogen with wind enhanced escape being strongly suppressed by collisions. It is concluded that wind enhanced escape is not an important process on Titan.

Curtis, S. A.↗