Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluoropolymers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Unique applications of fluoroepoxy materials

The following subject areas are covered: (1) fluoroepoxy and curing agents; (2) an excellent moisture vapor barrier coating; (3) as adhesives to bond Teflon without any surface treatment; (4) a new method to make thermosetting fluoropolymer foam; and (5) as a new antifoaming agent for epoxy material manufacturing and processing.

Lee, Sheng Yen↗

Durability evaluation of photovoltaic blanket materials exposed on LDEF tray S1003

Several candidate protective coatings on Kapton and uncoated Kapton were exposed to the low Earth orbital (LEO) environment on the Long Duration Exposure Facility (LDEF) to determine if the coatings could be used to protect polymeric substrates from degradation in the LEO environment. The coatings that were evaluated were 700 A of aluminum oxide, 650 A of silicon dioxide, and 650 A of a 4 percent polytetrafluoroethylene-96 percent silicon dioxide mixed coating. All of the coatings evaluated were ion beam sputter deposited. These materials were exposed to a very low atomic oxygen fluence (4.8 x 10 exp 19 atoms/sq. cm) as a result of the experiment tray being located 98 degrees from the ram direction. As a result of the low atomic oxygen fluence, determination of a change in mass was not possible for any of the samples including the uncoated Kapton. There was no evidence of spalling of any of the coatings after the approximately 33,600 thermal cycles recorded for LDEF. The surface of the uncoated Kapton, however, did show evidence of grazing incidence texturing. There was a 7-8 percent increase in solar absorptance for the silicon dioxide and aluminum oxide coated Kapton and only a 4 percent increase for the mixed coating. It appears that the addition of a small amount of fluoropolymer may reduce the magnitude of absorptance increase due to environmental exposure. Thermal emittance did not change significantly for any of the exposed samples. Scanning electron microscopy revealed few micrometeoroid or debris impacts, but the impact sites found indicated that the extent of damage or cracking of the coating around the defect site did not extend beyond a factor of three of the impact crater diameter. This limiting of impact damage is of great significance for the durability of thin film coatings used for protection against the LEO environment.

Sharon K Rutledge↗

Highly fluorinated polymers

The topics covered include the following: highly fluorinated polyesters; N-alkylated polyamides; highly fluorinated polyethers; and silicon-containing fluoropolymers.

Cassidy, Patrick E.↗

Trifluoromethyl-substituted polymers

Current work sponsored by the grant at Southwest Texas State University is directed toward the synthesis and characterization of: (1) N-alkylated polyamides derived from o-fluorinated diacids; (2) highly fluorinated polyethers; (3) polyesters derived from 2-hydroxy-2-propyl substituted arenes and/or 2,5-difluoroterephthalic acid; and (4) silicon-containing fluoropolymers. Work during the period from 1 July to 31 Dec. 1993 focused primarily on items 3 and 4 and on the development of a phosphorus containing modification of '12F-PEK.'

Source record↗

Near-ambient solid polymer fuel cell

Fuel cells are extremely attractive for extraterrestrial and terrestrial applications because of their high energy conversion efficiency without noise or environmental pollution. Among the various fuel cell systems the advanced polymer electrolyte membrane fuel cells based on sulfonated fluoropolymers (e.g., Nafion) are particularly attractive because they are fairly rugged, solid state, quite conductive, of good chemical and thermal stability and show good oxygen reduction kinetics due to the low specific adsorption of the electrolyte on the platinum catalyst. The objective of this program is to develop a solid polymer fuel cell which can efficiently operate at near ambient temperatures without ancillary components for humidification and/or pressurization of the fuel or oxidant gases. During the Phase 1 effort we fabricated novel integral electrode-membrane structures where the dispersed platinum catalyst is precipitated within the Nafion ionomer. This resulted in electrode-membrane units without interfacial barriers permitting unhindered water diffusion from cathode to anode. The integral electrode-membrane structures were tested as fuel cells operating on H2 and O2 or air at 1 to 2 atm and 10 to 50 C without gas humidification. We demonstrated that cells with completely dry membranes could be self started at room temperature and subsequently operated on dry gas for extended time. Typical room temperature low pressure operation with unoptimized electrodes yielded 100 mA/cm(exp 2) at 0.5V and maximum currents over 300 mA/cm(exp 2) with low platinum loadings. Our results clearly demonstrate that operation of proton exchange membrane fuel cells at ambient conditions is feasible. Optimization of the electrode-membrane structure is necessary to assess the full performance potential but we expect significant gains in weight and volume power density for the system. The reduced complexity will make fuel cells also attractive for smaller and portable power supplies and as replacement for batteries.

Holleck, G. L.↗

Gas Sensor Evaluations in Polymer Combustion Product Atmospheres

Toxic gases produced by the combustion or thermo-oxidative degradation of materials such as wire insulation, foam, plastics, or electronic circuit boards in space shuttle or space station crew cabins may pose a significant hazard to the flight crew. Toxic gas sensors are routinely evaluated in pure gas standard mixtures, but the possible interferences from polymer combustion products are not routinely evaluated. The NASA White Sands Test Facility (WSTF) has developed a test system that provides atmospheres containing predetermined quantities of target gases combined with the coincidental combustion products of common spacecraft materials. The target gases are quantitated in real time by infrared (IR) spectroscopy and verified by grab samples. The sensor responses are recorded in real time and are compared to the IR and validation analyses. Target gases such as carbon monoxide, hydrogen cyanide, hydrogen chloride, and hydrogen fluoride can be generated by the combustion of poly(vinyl chloride), polyimide-fluoropolymer wire insulation, polyurethane foam, or electronic circuit board materials. The kinetics and product identifications for the combustion of the various materials were determined by thermogravimetric-IR spectroscopic studies. These data were then scaled to provide the required levels of target gases in the sensor evaluation system. Multisensor toxic gas monitors from two manufacturers were evaluated using this system. In general, the sensor responses satisfactorily tracked the real-time concentrations of toxic gases in a dynamic mixture. Interferences from a number of organic combustion products including acetaldehyde and bisphenol-A were minimal. Hydrogen bromide in the products of circuit board combustion registered as hydrogen chloride. The use of actual polymer combustion atmospheres for the evaluation of sensors can provide additional confidence in the reliability of the sensor response.

Delgado, Rafael H.↗

XPS Study of Plasma- and Argon Ion-Sputtered Polytetrafluoroethylene

The similarity of plasma-polymerized tetrafluoroethylene (PPTFE) and the fluoropolymer film deposited by rf (radio frequency) plasma sputtering (SPTFE) of polytetrafluoroethylene (PTFE), noted earlier in the literature, has been reconfirmed. FT-IR (Fourier Transform Infrared), XPS (X ray Photoelectron Spectroscopy) and UV (ultraviolet) spectroscopy has been employed in apparently the first study to involve preparation of PPTFE and SPTFE in the same reactor and under comparable low-power plasma conditions. Most of the work concerned the use of He or Ar as sputtering gas, but some runs were also carried out with the other rare gases Ne, Kr and Xe. The C1s XPS spectra of SPTFE films displayed a relatively higher content of CF2 groups, and yielded higher F/C (fluorine / carbon) ratios, than PPTFE films, while the SPTFE films were somewhat more transparent in the UV than PPTFE. The F/C ratios for SPTFE were essentially independent of the rare gas used for sputtering. Increasing rf power from 10 to 50 W for Xe plasma-sputtering of PTFE resulted in successively lower F/C ratios (1.55 to 1.21), accompanied by sputtering of the glass reactor occurring at 40 W and above. Some limited XPS, FT-IR and UV data are presented on Ar ion-sputtered PTFE.

Golub, Morton A.↗

Protective Coating Enhances the Durability of Retroreflectors for the International Space Station

Corner cube reflectors (retroreflectors) will be used on the International Space Station to aid in rendezvous and docking. They are designed to reflect light, such as that from a laser, directly back to the source. The resulting bright reflection from the surface can be used for critical alignment purposes. The housing for the reflectors is composed of polyoxymethylene, a polymer known as Delrin (DuPont), which is highly susceptible to erosion by the atomic oxygen environment that surrounds the station. Atomic oxygen is highly chemically reactive and will convert polymers such as Delrin into volatile oxidation products. This could cause the reflectors to detach from the housing or could cause volatile products and other contamination to recondense onto the surface of the reflectors, causing them to darken. The NASA Lewis Research Center is applying their patented fluoropolymer-filled silicon dioxide coating to the surface of the Delrin retroreflector to prevent degradation in performance caused by reactions with atomic oxygen.

Rutledge, Sharon K.↗

Cryogenic Shrouds for Testing Thermal-Insulation Panels

Cryogenic shrouds have been designed and built for use in thermomechanical testing of samples of thermalinsulation panels on cryogenic vessels. In the original application for which these shrouds were specifically designed, the samples are representative of the large-area thermal-insulation panels on the space-shuttle external tanks that hold liquid hydrogen and liquid oxygen, and the purpose of the testing is to demonstrate the ability of bonded layers in the panels to resist delamination under a combination of applied uniaxial mechanical loads and realistic operational temperatures. Presumably, the shrouds and the tests performed by use of them could be modified to enable similar evaluation of thermomechanical properties of thermal-insulation panels for cryogenic vessels other than the external tanks of the space shuttles. The shrouds are required to enable maintenance of required temperatures on the inner and outer surfaces of the thermal-insulation-panel samples, to enable visual observation of the outer surfaces of the samples, and not to introduce any measurable loads into the panels. For each panel sample, there are two shrouds: one to be mounted on the inner surface (the surface that would be in contact with a tank containing a cryogenic liquid during normal use) and one to be mounted on the outer surface (the surface that would be exposed to ambient air or other warmer environment during normal use). The shrouds for testing specimens of thermal-insulation- panels for the liquid-hydrogen tank are made largely of titanium; the shrouds for testing specimens of thermal- insulation-panels for the liquid-oxygen tank are made largely of an aluminum- lithium alloy. The specific temperature requirements are the following: The inner shroud must make it possible to maintain a temperature of 321 degrees F (196 degrees C) [the approximate temperature of liquid nitrogen] or 453 F (about 269 C) [the approximate temperature of liquid helium] on the inner face of the sample. The outer shroud must make it possible to maintain a temperature between 30 degrees and 0 degrees F (between about 34 degrees and about 18 degrees C) on the outer surface of the sample by blowing a cryogenic gas or missile grade air along that surface. To enable viewing of the outer surface of the sample during testing, the outer shroud includes a window comprising two layers of poly(methyl methacrylate) with a gap between them to reduce fogging. To ensure that the shrouds do not introduce any measurable loads into a panel specimen, the shrouds are cushioned on the specimen by seals made of a fluoropolymer-membrane/fabric composite material and are held in place on the specimen by means of symmetrically placed clamps with poly(tetrafluoroethylene) pads. Instrumentation ports for thermocouples and strain gauges used in the tests are incorporated into the shrouds.

Norris, Jeffrey↗

Overview of the MISSE 7 Polymers and Zenith Polymers Experiments After 1.5 Years of Space Exposure

As part of the Materials International Space Station Experiment 7 (MISSE 7), two experiments called the Polymers Experiment and the Zenith Polymers Experiment were flown on the exterior of the International Space Station (ISS) and exposed to the low Earth orbit (LEO) space environment for 1.5 years. The Polymers Experiment contained 47 samples, which were flown in a ram or wake flight orientation. The objectives of the Polymers Experiment were to determine the LEO atomic oxygen erosion yield (Ey, volume loss per incident oxygen atoms, given in cu cm/atom) of the polymers, and to determine if atomic oxygen erosion of high and low ash containing polymers is dependent on fluence. The Zenith Polymers Experiment was flown in a zenith flight orientation. The primary objective of the Zenith Polymers Experiment was to determine the effect of solar exposure on the erosion of fluoropolymers. Kapton H (DuPont, Wilmington, DE) was flown in each experiment for atomic oxygen fluence determination. This paper provides an introduction to both the MISSE 7 Polymers Experiment and the MISSE 7 Zenith Polymers Experiment, and provides initial erosion yield results.

Yi, Grace T.↗

Integrated Electrical Wire Insulation Repair System

An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

Williams, Martha↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex®, M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton®, and mixtures of PTFE and Kapton®. Furnace temperatures ranged from 340o to 640o C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Smoke↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex(R), M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton(R), and mixtures of PTFE and Kapton(R). Furnace temperatures ranged from 340 to 640 C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Combustion↗

Pinhole Effects on Venus Superpressure Balloon Lifetime

Experimental results are presented for a series of experiments that addressed the effect of small pinhole defects on the potential lifetime of a Venus superpressure balloon. The experiments were performed on samples of a candidate balloon envelope material through which a single small hole of 80 to 300 microns in diameter was deliberately made in each one by puncturing with a metal pin. The material was mounted horizontally in a test apparatus and then a 2-3 mm thick layer of sulfuric acid was placed on top to mimic balloon wetting at Venus. Acid penetration and damage manifested itself as a darkening of the aluminum metal and adhesive layers around the hole in the balloon material. There were no test conditions under which the acid simply fell through the pinhole due to gravity because the surface tension forces always compensated at this size. Very little acid-damaged material was observed for the smallest 80 micron pinholes while gas flowed through the hole due to balloon-like pressurization: the black spot size was approximately 0.2 mm in diameter after 6 days with 86% sulfuric acid. The damage area grew more quickly in the absence of gas flowing out of an 80 micron hole, namely at a rate of 2 mm/day. It was concluded that the flow of escaping gas out of the hole provides a substantial reduction of the rate of acid penetration and damage. Larger diameter pinholes of approximately 300 micron diameter showed larger growth rates of 0.7 mm/day with gas flow and 1.7 mm/day without. The pinhole size did not change over the duration of these experiments because the material has an outer layer of fluoropolymer film that remained intact during the process and thereby held the hole size constant. None of the damage rates measured in these experiments pose a threat to the lifetime of the balloon over the projected course of a 30 day mission because the affected area is too small to cause a structural failure either through direct damage or increased solar heating and attendant balloon pressurization leading to burst.

Venus↗

Erosion Results of the MISSE 8 Polymers Experiment After 2 Years of Space Exposure on the International Space Station

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded due to reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft, it is important to know the LEO AO erosion yield (E(sub y), volume loss per incident oxygen atom) of materials susceptible to AO reaction. A spaceflight experiment, called the Polymers Experiment, which contained 42 samples, was developed to determine the effect of solar exposure on the AO E(sub y) of fluoropolymers flown in ram, wake, or zenith orientations. The Polymers Experiment was exposed to the LEO space environment on the exterior of the International Space Station (ISS) as part of the Materials International Space Station Experiment 8 (MISSE 8) mission. The MISSE 8 mission included samples flown in a zenith/nadir orientation for 2.14 years in the MISSE 8 Passive Experiment Container (PEC), and samples flown in a ram/wake orientation for 2.0 years in the Optical Reflector Materials Experiment-III (ORMatEIII) tray. The experiment included Kapton H (Registered Trademark) witness samples for AO fluence determination in each orientation. This paper provides an overview of the MISSE 8 mission, a description of the flight experiment with details on the polymers flown, the characterization techniques used, the AO fluence for each exposure orientation, and the LEO E(sub y) results. The E(sub y) of Teflon fluorinated ethylene propylene (FEP) samples flown in ram, wake, and zenith orientations have been compared, and the E(sub y) was found to be highly dependent on orientation and therefore environmental exposure. The FEP E(sub y) was found to directly correlate with the solar exposure/AO fluence ratio showing the effect of solar radiation and/or heating due to solar exposure on FEP erosion. In addition, back-surface carbon painted FEP (C-FEP) flown in the zenith orientation had a significantly higher E(sub y) than clear FEP or Al-FEP further indicating that heating has a significant impact on the erosion of FEP. This experiment provides valuable LEO flight data on the erosion of Teflon FEP, a commonly used spacecraft thermal insulation.

Teflon↗

Ultra-Pure, High Endurance Liquid Bladder with Volume Sensor for Space Applications

The NASA Portable Life Support System (PLSS) for the Exploration Extravehicular Mobility Unit (xEMU) incorporates a Feedwater Supply Assembly (FSA) to store consumable cooling water. The FSA accepts pure water prior to each Extra-Vehicular Activity (EVA), then supplies this water to a membrane evaporator at ambient suit pressure during the eight hour EVA. The FSA must function reliably for hundreds of EVAs over 15 years of service without introducing contamination that may accumulate and foul the membrane. We present a unique design that combines the benefits of a flexible fluoropolymer bladder with the strength and convenience of a rigid tank, providing an ultra-pure, ambient-pressure reservoir with fill-drain cycle life exceeding 3000, internal pressure tolerance exceeding 100 psi, high volumetric efficiency, near-zero dead volume, optical transparency for visual inspection, simplified mounting, and very low mass. We also incorporate a novel volume sensor suitable for both microgravity and arbitrarily accelerated environments and capable of real-time monitoring with accuracy on the order of 2.5% full scale. Analytical predictions are supported by experimental test data from a mature subscale prototype.

PLSS Portable Life Support System FSA Feedwater Su↗

Water Dynamics of Superacid Aromatic Proton Exchange Membranes for Fuel Cell Applications

Proton exchange membranes (PEMs) with high conductivity are of critical importance for the development of fuel cells, electrolyzers, and other electrochemical technologies. In this research, poly(1,1,2,2-tetrafluoro-2-phenoxyethane-1-sulfonic acid) (PTPS) with an aromatic polymer main chain and a perfluorinated superacidic polymer side chain was synthesized. The water dynamics of PTPS were characterized across various length scales using a combination of Fourier-transform infrared spectroscopy (FTIR) and nuclear magnetic resonance (NMR) and compared with Nafion, a standard perfluorinated PEM, and sulfonated poly(ether sulfone) (SPES 40), an aromatic PEM without perfluorinated superacid side chains. The T 1 and T 2 relaxation times of water in the samples probed by NMR increase from SPES 40 to PTPS to Nafion, indicating that the local motion of the water molecules becomes faster. This trend corresponds well with the relative fraction of bulk-like water determined using FTIR. At larger length scales, the diffusion coefficient of water was characterized using pulsed-field gradient NMR (PFG-NMR). At a longer diffusion time (Δ = 100 ms), PTPS has a smaller diffusion coefficient compared with both Nafion and SPES 40, due to restricted diffusion, and this effect is also evident in the proton conductivity of the hydrated membranes. From this comparison, it is apparent that the aromatic backbone and side chain type greatly influence the water dynamics in PEMs at various length scales and the water dynamics significantly impact the bulk proton conductivity. These insights will lead to new designs for aromatic PEMs and help to identify bottlenecks in current materials.

25 ENERGY STORAGE↗

Stereochemically‐Controlled Fluorinated Copolymers for Selectively Permeable Barrier Applications

Selective oxygen permeability coupled with low water vapor transmission is essential for biomedical and packaging applications requiring controlled oxygen flux under humid conditions. However, most high‐performance barrier polymers depend on perfluoroalkyl substances (PFAS), whose persistence and regulatory restrictions limit their long‐term applicability. We designed a series of stereocontrolled thiol‐yne‐based polyesters, including both fluorinated and non‐fluorinated variants, for selective oxygen permeability with considerable water barrier performance. Tailoring polymer crystallinity and morphology tuned both oxygen transport and mechanical properties. Fluorinated polymers demonstrated enhanced hydrophobicity and water resistance while maintaining oxygen diffusivity within a range relevant to oxygen‐sensing applications. Structure–property relationships were elucidated through small‐ and wide‐angle X‐ray scattering, revealing semi‐crystalline domains influenced by fluorine content and dithiol chain length. Barrier performance was rigorously evaluated via water vapor transmission rate and dynamic vapor sorption, showing reduced water uptake with increasing dithiol monomer length and crystallinity. In conclusion, this work introduces a PFAS‐free alternative to conventional barrier materials and establishes a tunable materials platform with potential relevance for biomedical devices and packaging systems requiring controlled oxygen permeability.

36 MATERIALS SCIENCE↗