Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fire and Drought Affect Multiple Aspects of Diversity in a Migratory Bird Stopover Community

Drought and high-severity, stand-replacing wildfires can have substantial impacts on the composition of avian communities, including stop-over communities during migration. An inextricable link exists between drought and wildfire, each operating and impacting across different timescales. Many studies have found nonlinear avian abundance trends in breeding community time series data that include pre- and post-fire observations, describing an initial decrease in abundance followed by rapid increases that can attenuate over time. Here, we use a fall bird-banding dataset to evaluate shifts in a drought-impacted avian community following wildfire from taxonomic, functional, and phylogenetic perspectives. We looked at the community as a whole and also categorized birds as residents, migrants, and breeders to assess potential varying responses at the study site. We observed post-fire shifts in functional and phylogenetic diversity that corresponded to changes in vegetation. An influx of migratory insectivores post-fire drove much of the variation between pre- and post-fire avian communities and toward a more related, less phylogenetically dispersed community. A concurrent monsoon season drought was also associated with functional and phylogenetic diversity, highlighting the intertwined pulse press effects on avian communities. Overall, our results suggest that, although bird communities are immediately impacted by fire-driven resource changes, they can rebound over time, it is unclear how long-term drought may continue to shape the composition of these avian communities.

59 BASIC BIOLOGICAL SCIENCES↗

Interplay of Topography, Fire History, and Climate on Interior Alaska Boreal Forest Vegetation Dynamics in the 21st Century: A Landsat Time-Series Analysis

This study investigates vegetation dynamics in boreal forests of Interior Alaska, focusing on topography, fire history, and climate influences. The study area includes Bonanza Creek Experimental Forest (BCEF) and surrounding region, categorized by topography (upland, floodplain, lowland) and fire history. Using Mann–Kendall trend and Theil–Sen slope analyses on Landsat-derived spectral metrics: Normalized Difference Vegetation Index (NDVI) and Normalized Burn Ratio (NBR), we observed a shift from browning to greening trends, particularly in historically burned areas. The photosynthetic activity in burned upland converged with unburned areas ~30 years post-fire, coincident with a shift towards deciduous dominance during post-fire succession. Normalized Difference Moisture Index (NDMI) trends revealed a significant increase in vegetation moisture content across all topographies. We introduce Effective Seasonal Precipitation Index (ESPI), which combines prior-year annual precipitation with current-year spring snow depth. Its positive correlation with NDMI highlights its potential for monitoring vegetation moisture dynamics at the landscape scale. Furthermore, by correlating dendrochronology-based climate indices, we found strong correlation between NDMI and normalized Supplemental Precipitation Index (nSPI), across topographies. Overall, this research provides critical insights into how climate and fire influence interior boreal vegetation, highlighting the effects of increased precipitation, and topography on shaping differential vegetation responses across the landscape.

Google Earth Engine↗

Modeling the impact of smoke from prescribed fire on road visibility

Prescribed fires are planned to achieve conservation and fuel reduction objectives while minimizing smoke ground concentration to limit health impacts and road visibility impairment. Prescribed burns cannot indeed be conducted if those hazards are not within predefined limits. This paper proposes a new framework to evaluate road visibility that overcomes the limitation of the state of the art model, VSMOKE. The framework leverages the fast-running framework QUIC-Fire/QUIC-SMOKE to capture fire and smoke dynamics, and the timing and duration of hazardous conditions on the road network close to the burn unit (within 50–100 km). The paper presents parametric study using a real burn plot at Fort Stewart (GA, USA), under hypothetical wind conditions to understand the interplay between buoyancy and smoke dilution. Here, results showed that faster winds caused fire escape while slower winds did not achieve a complete burn. Furthermore, faster winds featured brief road visibility reduction below braking distance.

54 ENVIRONMENTAL SCIENCES↗

California annual grass phenology and allometry influence ecosystem dynamics and fire regime in a vegetation demography model

Grass-dominated ecosystems cover wide areas of the land surface yet have received far less attention from the Earth System Model (ESM) community. This limits model projections of ecosystem dynamics in response to global change and coupled vegetation–climate dynamics. We used the Functionally Assembled Terrestrial Ecosystem Simulator (FATES), a dynamic vegetation demography model, to determine ecosystem sensitivity to alternate, observed grass allometries and biophysical traits, and evaluated model performance in capturing California C 3 annual grasslands structure and fire regimes. Grass allometry, leaf physiology, plant phenology, and plant mortality all drove the seasonal variation in matter and energy exchange and fire dynamics in California annual grasslands. Allometry influenced grassland structure and function mainly through canopy architecture-mediated space and light competition instead of through carbon partitioning strategy. Regional variation in grassland annual burned area was driven by variation in ecosystem productivity. Our study advances the modeling of grassy ecosystems in ESMs by establishing the importance of grass allometry and plant phenology and mortality in driving C 3 annual grassland seasonal dynamics and fire regime. The calibrated annual grass allometry and biophysical traits presented can be applied in future studies to project climate–vegetation–fire feedbacks in annual grass-dominant ecosystems under global change.

54 ENVIRONMENTAL SCIENCES↗

Organic Matter Composition in June 2023 and September 2023 Across the McKenzie Sub-Basin Impacted by the 2020 Holiday Farm Fire

This dataset represents results from a field study aiming to understand the variability in post-fire responses of dissolved organic matter and determine drivers of post-fire responses. Samples were collected at 58 sites within the McKenzie River Watershed (Oregon, USA) that were upstream, within, and downstream of the Holiday Farm Fire burn perimeter. The samples were collected in June 2023 and September 2023 during storm events, approximately 3 years post-fire. Samples were characterized for benezenepolycarboxylic acids (BPCA) and ultra-high resolution mass spectrometry. Dissolved organic carbon and optics (absorbance and fluorescence) data can be found in a separate data packages (https://ir.library.oregonstate.edu/concern/datasets/zc77sz60m, https://ir.library.oregonstate.edu/concern/datasets/mc87q034m). Related data from a subset of sites from 2020-2022 can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1869708 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2478546. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) benzene polycarboxylic acid (BPCA) concentration data; (7) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; (8) folder of high resolution characterization of organic matter via 12 Tesla FTICR-MS data generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

Impact of Forest Canopy Structure on Buoyant Plume Dynamics During Wildland Fires

Heterogeneous forest canopies can generate complex turbulent structures, but in the presence of a fire plume, these interactions are not fully understood. This study investigates the influence of forest canopy heterogeneity on buoyant plume dynamics resulting from surface thermal anomalies representing wildland fires, utilizing Large Eddy Simulation (LES). The Parallelized Large-Eddy Simulation Model (PALM) was employed to simulate six canopy configurations: no canopy, homogeneous canopy, external plume-edge canopy, internal plume-edge canopy, 100 m gap canopy, and 200 m gap canopy. Each configuration was analyzed with and without a static surface heat flux patch of 5000 W ∙ m -2 , resulting in a resting buoyant plume. Simulations were conducted under three crosswind speeds: 0, 5, and 10 m ∙ s -1 . Results show that canopy structure significantly modifies plume behavior, mean flow, and turbulent kinetic energy (TKE) budgets. Plume updraft speed and tilt varied with canopy configuration and crosswind speed. Horizontal pressure gradients associated with plume-atmosphere interaction were modified based on the canopy configuration, resulting in varying crosswind speed reductions at the plume region. Strong momentum absorption was observed above the canopy for the crosswind cases, with the greatest enhancement in the gap canopies. Momentum injection from below the canopy due to the heat source was also observed, resulting in plume structure modulation based on canopy configuration. TKE was found to be the largest in the gap canopy configurations. TKE budget analysis revealed that buoyant production dominated over shear production. At the center of the heat patch, the gap canopy configurations showed enhanced buoyancy within the gap. These results improve our knowledge of fire-canopy-atmosphere interactions that can inform fire models on the impacts of canopy heterogeneity on plume dynamics and ember ejections.

54 ENVIRONMENTAL SCIENCES↗

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Resolution Fire Weather Index Data for the Conterminous US (1980–2099), Version 1

This dataset presents a suite of high-resolution fire weather index datasets calculated from observation (gridMet, Livneh, Daymet V4), reanalysis (AgERA5), downscaled hydro-climate projections over the conterminous United States (CONUS) based on multiple selected Global Climate Models (GCMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). Aside from the daily FWI datasets, we also include a set of FWI extreme indicators at annual, seasonal, and monthly scales, including 1) fwixx: maximum FWI; 2) fwisa: mean FWI. For annual fwisa, it refers to the season with the maximum seasonal average; 3) fwils: Length of fire season over a specified period, where fire season is defined as the days exceeding the median value of the normalized FWI during the reference period (1980-1984); 4) fwixd: Number of extreme fire weather days over a specified period, where extreme day is defined as the day with FWI > the 95th percentile of the FWI during the reference period (1980-1984). All FWI datasets cover 1980-2020 baseline and the model simulated products including the downscaled products additionally include 2021-2099 near-future periods under the high-end (SSP585) emission scenario.

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Post-Fire Vegetation Monitoring Report for Calendar Year 2025

The Hanford Site and the surrounding greater Columbia Basin is comprised of an expanse of shrub-steppe habitats that provides exceptional ecological value to plants and animals. The U.S. Department of Energy, Hanford Field Office (HFO)-managed portion of the Hanford Site, referred to from herein as Central Hanford, has experienced repeated wildfires resulting in profound, often adverse, effects on the landscape. This report summarizes these fires and fire monitoring efforts that occurred in calendar year (CY) 2025 and analyzes the post-fire vegetation recovery in restored areas to inform future post-fire response actions.

54 ENVIRONMENTAL SCIENCES↗

Model Validation Database for Fires Involving Fuels at Liquefied Natural Gas Facilities (Version 2)

This document provides a description of the model evaluation protocol (MEP) database for fires involving liquefied natural gas (LNG) and processing fuels at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model’s suitability to predict thermal exclusion zones resulting from a fire. The database includes measurements from pool fire, jet fire, and fireball experiments which are provided in a spreadsheet. Users are to enter model results into the spreadsheet which automatically generates statistical performance measures and graphical comparisons with the experimental data. The intent of this document is to provide a description of the experiments and of the procedure required to carry out the validation portion of the MEP. In addition, the statistical performance measures, measurements for comparisons, and parameter variation are provided.

03 NATURAL GAS↗

Model Evaluation Protocol for Fire Models Involving Fuels at Liquefied Natural Gas Facilities (Version 2)

This document provides a description of the model evaluation protocol (MEP) for pool fires, jet fires, and fireballs involving liquefied natural gas (LNG) and processing fuels at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model’s suitability to predict heat flux from fires. Three components, namely, a scientific assessment, model verification, and model validation comprise the MEP. The evaluation of a model satisfying these three components is to be documented in the form of a model evaluation report (MER). Discussion of models for the prediction of fire, detailed information on each of the three MEP components, the MEP procedure regarding new versions of previously approved models, and the format of the model evaluation report (MER) are provided.

03 NATURAL GAS↗

The Co-Firing of Pine Biomass and Waste Coal in 100 and 600 MW Power Plants: A Sustainable Approach to Reduce GHG Emissions

Climate change is a global issue that has gained much attention recently. Co-firing biomass with coal/waste coal reduces the electricity sector’s GHG emissions sustainably. This study uses commercial software to model waste coal and biomass co-firing in 100 MW and 600 MW power plants. The objective is to assess the effects of fluid types (subcritical and supercritical), plant capacities (100 MW and 600 MW), boiler types (pulverized coal and circulating fluidized bed boilers), biomass and waste coal co-firing ratios (0:100, 20:80, 40:60, 60:40, 80:20, and 100:0), and carbon capture and storage efficiencies (0%, 90%, 95%, and 97%) on performance parameters such as net plant efficiency, heat rate, net plant CO2 and SO2, and particulate matter emissions. The feedstocks selected for this investigation include anthracite waste coal and loblolly pine biomass. As the biomass fraction increases from 0% to 100%, co-fired power plants net efficiency increases by 3–8%. Supercritical plants had a 6% higher net plant efficiency than the subcritical plants. The study found that the biomass’s high heating value decreased the fuel flow rate and reduced plant CO2 emissions by 10–16%. With 100% biomass power plant feed and 90% carbon capture and storage efficiency, CO2 emissions drop by 83% and SO2 and PM emissions drop to zero.

Bhoi, Prakashbhai R. (ORCID:0000000333104888)↗

Burn parameters affect PAH emissions at conditions relevant for prescribed fires

Wildfire smoke is a health hazard as it contains carcinogenic volatile compounds and fine particulate matter. In particular, exposure to polycyclic aromatic hydrocarbons (PAHs) is a major concern, since these compounds have been recognized as important contributors to the overall carcinogenic risk. In this work, gas and particle-phase PAH emissions from combustion of Eastern White Pine (Pinus strobus) were quantified using time-of-flight mass spectrometry over a range of burn conditions representative of wildfires and prescribed fires, including fuel moisture, heat flux, and oxygen concentration. We found that changing the burn environment lead to a variability of up to 77% in phenanthrene/anthracene emissions. This could explain a large part of the variability in PAH emission factors from biomass combustion reported in the literature. Here, we found that optimal conditions for fuel moisture content of 20–30%, sample heat load of 60 - 70 kW m -2 , and oxygen concentrations of 5–15% can significantly reduce the emissions of heavy molar weight PAHs. Our analysis showed that the relative carcinogenic risk from PAH exposure can be reduced by more than 50% under optimal conditions. In light of the increasing use of prescribed fire for forest management, the relationship between emissions and burn conditions that we have established provides a guidance for assessing the expected health impact from prescription burns, and can inform strategies to reduce PAH emissions from prescribed fire activities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Downscaled CMIP5 projections of physical fire risk understate historical trends

Reliable projections of wildfire risk are important for multi-sector impacts analysis. Statistically downscaled and bias-corrected Earth system model ensemble products are routinely used to analyze regional physical wildfire risk, but evaluations of historical observed trends and variability are lacking. Here, we evaluate physical fire risk over the western United States using the Canadian Forest Fire Weather Index (FWI) by comparing model outputs from the Coupled Model Intercomparison Project Phase 5 (CMIP5), statistically downscaled via the Multivariate Adaptive Constructed Analogs (MACA) approach, against the observational target dataset gridMET, a gridded high-resolution surface meteorological product. We analyze multidecadal trends and interannual variability in seasonal average FWI for the historical period and future projections under two emissions scenarios, and we compare MACA-CMIP5 ensemble results with a simple time series model that generates historical and future projections of seasonal FWI based on bootstrapping observed historical trends and variability. Our findings indicate that MACA-CMIP5 accurately captures the magnitude and spatial patterns of seasonally averaged FWI but tends to underestimate historical decadal trends. We show that future increases in fire risk may be underestimated relative to the simple time series model that projects historical variability into the future. We also highlight that model biases in relative humidity contribute significantly to model-data differences. Our results underscore the importance of historical hindcasting exercises for informing broader multi-sector applications.

FWI↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Evaluating the Performance and Reliability of Screen-Printable Fire-Through Copper Paste on PERC Solar Cells

A bifacial silicon heterojunction solar cell demands approximately 210 mg usage of silver paste (9 busbars, 24.5%, bifacial, M6 size wafer). Copper is an excellent alternative to silver: 100x cheaper, similar elecvtrical resistivities, and 1000x more abundant. Successful demonstration of large area selective emitter PERC solar cells using Cu fire-through paste with FF approximately 75% and approximately 19%. Paste chemistry results in oxide-based Cu diffusion barrier, leading to good reliability of the devices: 1000h DHT giving a 3.5% efficiency drop. The additional series resistance still needs to be lowered. Printed and fired cell performance is governed mostly by pFF, especially J02 ; same for DHT degradation. Further improvement in printing and firing optimization for lower series resistance and higher FF.

Ag↗

Peatland fires in Alaska will double by the end of the century

During recent summers, warm and dry conditions have increased the occurrence of wildfires and potentially peat-fires across Alaska. Limitations in resolving the fine-scale distribution of peatlands and climate observations have constrained our ability to accurately predict peat-fire dynamics. Using a new high-resolution peatland map of Alaska, we evaluated the climate and environmental controls of past and future peat-fire activity. Ensemble machine learning models identified reduced soil moisture, higher temperatures, and evapotranspiration as key predictors of annual total burned peatland area (tenfold CV R 2 = 0.62, RMSE = 221.1 km 2 ). By the end of the twenty-first century, models forced with climate datasets from representative concentration pathways (RCPs) 4.5, 6.0, and 8.5 emission scenarios project a statewide doubling of burned peatlands (increasing 61–121%), with regional increases ranging from 25–165% in polar, 61–95% in boreal, and 102–106% in maritime ecoregions. These projections indicate that wildfires will progressively encroach further into organic-rich moist and wet peaty soils, potentially amplifying soil carbon release across Alaska.

climate-change ecology↗

Comparing gas composition from fast pyrolysis of live foliage measured in bench-scale and fire-scale experiments

Background: Fire models have used pyrolysis data from oxidising and non-oxidising environments for flaming combustion. In wildland fires pyrolysis, flaming and smouldering combustion typically occur in an oxidising environment (the atmosphere). Aims: Using compositional data analysis methods, determine if the composition of pyrolysis gases measured in non-oxidising and ambient (oxidising) atmospheric conditions were similar. Methods: Permanent gases and tars were measured in a fuel-rich (non-oxidising) environment in a flat flame burner (FFB). Permanent and light hydrocarbon gases were measured for the same fuels heated by a fire flame in ambient atmospheric conditions (oxidising environment). Log-ratio balances of the measured gases common to both environments (CO, CO 2 , CH 4 , H 2 , C 6 H 6 O (phenol), and other gases) were examined by principal components analysis (PCA), canonical discriminant analysis (CDA) and permutational multivariate analysis of variance (PERMANOVA). Key results: Mean composition changed between the non-oxidising and ambient atmosphere samples. PCA showed that flat flame burner (FFB) samples were tightly clustered and distinct from the ambient atmosphere samples. CDA found that the difference between environments was defined by the CO-CO 2 log-ratio balance. PERMANOVA and pairwise comparisons found FFB samples differed from the ambient atmosphere samples which did not differ from each other. Conclusion: Relative composition of these pyrolysis gases differed between the oxidising and non-oxidising environments. This comparison was one of the first comparisons made between bench-scale and field scale pyrolysis measurements using compositional data analysis. Implications: These results indicate the need for more fundamental research on the early time-dependent pyrolysis of vegetation in the presence of oxygen.

54 ENVIRONMENTAL SCIENCES↗