Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the noise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

Johnson, Hans↗

Helium Degassing Filter for Mercury Process Gas Liquid Separator

Testing was conducted to find a suitable filter to help separate helium gas from the Spallation Neutron Source’s mercury process loop. This filter is proposed for installation on the gas-liquid separator (GLS) vent line to prevent a column of liquid mercury from flowing outside of the process loop shielding in the service bay. The filter’s desired properties are to prevent the passage of liquid mercury, provide minimal resistance to helium flow, resist radiation, operate for the lifetime of the target, be replaceable, and have a reliable construction. Testing concluded that the Mott Corporation POU-10-S series of filters provided the best performance available. The filters could stop most liquid mercury passage while allowing helium passage at nominal pressures above the GLS in standard conditions. This result has several implications for the design of the GLS vent system.

Weinmeister, Justin↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the n oise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Making an s1G Self-Preserving Environmental DNA (eDNA) Filter from Sustainable Materials

Environmental DNA (eDNA) sampling of aquatic environments is a powerful new tool for resource managers to use in detecting the presence of rare and endangered species. The use of eDNA for species detection is quickly becoming an industry-standard methodology in environmental science, and the technology sector is moving quickly to create purpose-built tools for eDNA sampling. Smith-Root, Inc. pioneered the new technology of self-preserving eDNA filters that automatically preserve the DNA captured on filters by desiccating the internal filter membrane. This capability saves the sampling technician significant time in the field and drastically reduces the potential for sample contamination. One main constraint of this new technology, however, is the necessity of single-use plastics for eDNA sampling. Single-use designs are employed because sampling equipment must be devoid of potential contaminating DNA, and the time required to sterilize equipment is often not cost-effective for practitioners. Thus, this technology is creating a significant new source of plastic waste—something that eDNA practitioners, and society, would like to avoid. This project explores the use of alternative bio based polymers and composites as replacements for incumbent industrial standards for eDNA filtration systems, with an emphasis on ease of processing and biodegradable options. 8 candidate materials, 3 for the top filter housing and 5 for the bottom filter housing, were investigated to replace incumbent housing materials. Of the 8 candidates, 2 materials were identified for future investigation which met performance requirements, were bio-based and could potentially offer better disposal options like soil degradation or composting, features sought by the customers of these products. The top housing candidate, material 1, has comparable performance to the incumbent material and equally manufacturable. The bottom housing candidate, material 6, improved desiccation performance by 81% after 1 hour in comparison to the incumbent material, is 100% bio-based, compostable and can be sourced domestically throughout the U.S.A.

36 MATERIALS SCIENCE↗

Aerosol-Assisted Deposition for TiO 2 Immobilization on Photocatalytic Fibrous Filters for VOC Degradation

Atomization and spraying are well-established methods for the production of submicrometer- and micrometer- sized powders. In addition, they could be of interest to the immobilization of photocatalytic nanoparticles onto supports because they enable the formation of microporous films with photocatalytic activity. Here, we provide a comparison of aerosol-assisted immobilization methods, such as spray-drying (SD), spray atomization (SA), and spray gun (SG), which were used for the deposition of TiO 2 dispersions onto fibrous filter media. The morphology, microstructure, and electronic properties of the structures with deposited TiO 2 were characterized by SEM and TEM, BET and USAXS, and UV-Vis spectrometry, respectively. The photocatalytic performances of the functionalized filters were evaluated and compared to the benchmark dip-coating method. Our results showed that the SG and SA immobilization methods led to the best photocatalytic and operational performance for the degradation of toluene, whereas the SD method showed the lowest degradation efficiency and poor stability of coating. We demonstrated that TiO2 sprays using the SG and SA methods with direct deposition onto filter media involving dispersed colloidal droplets revealed to be promising alternatives to the dip-coating method owing to the ability to uniformly cover the filter fibers. In addition, the SA method allowed for fast and simple control of the coating thickness as the dispersed particles were continuously directed onto the filter media without the need for repetitive coatings, which is common for the SG and dip-coating methods. Our study highlighted the importance of the proper immobilization method for the efficient photocatalytic degradation of VOCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filtering micro-operations for a micro-operation cache in a processor

A processor includes a micro-operation cache having a plurality of micro-operation cache entries for storing micro-operations decoded from instruction groups and a micro-operation filter having a plurality of micro-operation filter table entries for storing identifiers of instruction groups for which the micro-operations are predicted dead on fill if stored in the micro-operation cache. The micro-operation filter receives an identifier for an instruction group. The micro-operation filter then prevents a copy of the micro-operations from the first instruction group from being stored in the micro-operation cache when a micro-operation filter table entry includes an identifier that matches the first identifier.

Scrbak, Marko↗

In-Band Scattering and Absorption of Infrared Blocking Foam Filters for Millimeter-wave Cameras

Expanded closed-cell polymer foams are widely used as thermal infrared (IR) blocking filters in millimeter-wave cameras, particularly for Cosmic Microwave Background observations. Precise knowledge of their millimeter-wave properties is essential for optimizing sensitivity. We present broadband (150 GHz - 2 THz) transmittance spectroscopy of Styroace-II and several Zotefoam filters, fitting their spectra with a radiative transfer model incorporating dielectric absorption and Rayleigh, Mie, and higher-order scattering. For a typical 5~cm thick filter stack at 280~GHz, Styroace-II exhibits ${\sim}10\%$ scattering with absorption estimated as ${\lesssim}5\%$ by effective-medium theory, while Zotefoam HD30 offers superior performance at ${\sim}3\%$ scattering and absorption likewise bounded to ${{\lesssim}0.3\%}$. Each model component is constrained at the ${\sim}0.1\%$ transmittance level for millimeter wavelengths. We observe batch-to-batch scattering variability of up to 2 percentage points in foams with multiple tested batches. Less commonly used Zotefoam formulations (LD15 and LD24) can further reduce in-band scattering to ${<}1\%$ while maintaining negligible in-band absorption and likely comparable IR blocking due to shared polyethylene absorption features and similar cell sizes. Based on this work, a filter constructed from the best measured LD24 batch has replaced the Styroace-II filter in a Simons Observatory 220/280 GHz Small Aperture Telescope.

Thomas, Alex [Chicago U., Astron. Astrophys. Ctr.;↗

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Epoxy IR Filters for Superconducting Resonators

Infrared radiation leakage through dielectrics in coaxial cabling can create unwanted quasiparticles in superconducting resonators if allowed to reach devices unattenuated. Modern experimental setups commonly incorporate epoxy-based filter blocks on readout and control lines in order to mitigate this effect; however, most of these multi-channel designs require specialized mounting hardware. Here, this investigation details the design and construction of single-channel inline infrared filters, and finds that their installation in the readout system for an aluminum resonator increased its quality factor by an average of 12% across a range of operating temperatures and powers. The option to incorporate general-purpose inline filters instead of designing custom filter blocks and mounts should prove more convenient for many newer experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging pyrometry for most color cameras using a triple pass filter

A simple combination of the Planck blackbody emission law, optical filters, and digital image processing is demonstrated to enable most commercial color cameras (still and video) to be used as an imaging pyrometer for flames and explosions. The hardware and data processing described take advantage of the color filter array (CFA) that is deposited on the surface of the light sensor array present in most digital color cameras. In this work, a triple-pass optical filter incorporated into the camera lens allows light in three 10-nm wide bandpass regions to reach the CFA/light sensor array. These bandpass regions are centered over the maxima in the blue, green, and red transmission regions of the CFA, minimizing the spectral overlap of these regions normally present. A computer algorithm is used to retrieve the blue, green, and red image matrices from camera memory and correct for remaining spectral overlap. A second algorithm calibrates the corrected intensities to a gray body emitter of known temperature, producing a color intensity correction factor for the camera/filter system. The Wien approximation to the Planck blackbody emission law is used to construct temperature images from the three color (blue, green, red) matrices. A short pass filter set eliminates light of wavelengths longer than 750 nm, providing reasonable accuracy (±10%) for temperatures between 1200 and 6000 K. The effectiveness of this system is demonstrated by measuring the temperature of several systems for which the temperature is known.

47 OTHER INSTRUMENTATION↗

Development of a narrow stopband filter for spectroscopic fast ion deuterium-alpha measurements

A new technique to attenuate the unshifted deuterium Balmer-alpha (D-alpha) emission is developed and tested for the fast ion D-alpha (FIDA) diagnostic. The unshifted D-alpha emission, at λ = 656.1 nm, is around three orders of magnitude higher than the desired FIDA emission. Blocking the strong emission feature is essential to prevent blooming and light smearing on the CCD chip and scattered light contamination. The new method is a notch filter approach that utilizes the reflection from ultra-narrow bandpass filters to block the saturating signal before it enters the spectrometer. Collimated light from the fibers is reflected off the filter at a 15° angle of incidence. Measurements show that a center wavelength transmission of 0.006 and a blocking full width at half maximum of ~ 1 nm are achieved by using a 200 μm fiber and a 20 mm focal length collimator with two filters.

47 OTHER INSTRUMENTATION↗

Angularly resolved spectral reconstruction of x rays via filter pack attenuation

We have designed a new filter pack array to measure angular variations in x-ray spectra during a single shot. The filter pack was composed of repeating identical columns of aluminum and copper filters of varying thicknesses. These columns were located at different positions to measure the spectrum at each corresponding angle. This array was utilized in an experiment to measure the energy evolution of betatron x rays in a laser wakefield accelerator by curving the wakefield with a transverse density gradient, streaking the x rays across the array in front of an x-ray charge-coupled device (CCD) camera. After subtracting the background and “flattening” the image to remove spatial nonuniformities, a critical energy was calculated for each position that produced the best agreement with the measured signal. There was a clear change in critical energy with angle, shedding light on the dynamics of the electrons that traveled through the accelerator. Furthermore, these angles correspond to distinct emission times, covering a timescale of tens of picoseconds. The filter pack was capable of recovering these angular details without the impact of errors introduced by shot-to-shot variability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal Characterization and Filtering of Sensor Data to Support Anomaly Detection

Here, we present an approach for characterizing complex temporal behavior in the sensor measurements of a system in order to support detection of anomalies in that system. We first characterize typical behavior by extending a hidden Markov model-based approach to time series alignment. We then use a trace of that learned behavior to develop a particle filter that enables efficient estimation of the filtering distribution on the state space. This produces filtered residuals that can then be used in an anomaly detection framework. Our motivating example is the daily behavior of a building’s heating, ventilation, and air conditioning (HVAC) system, using sensor measurements that arrive every minute and induce a state space with 15,120 states. We provide an end-to-end demonstration of our approach showing improved performance of anomaly detection after application of alignment and filtering compared to the unaligned data. The proposed model is implemented as a computationally efficient R package alignts (align time series) built with R and Fortran 95 with OpenMP support.

47 OTHER INSTRUMENTATION↗

Optimal Modulation and DM Filter Design for a High Switching Frequency Single-Stage Microinverter

This paper presents an optimal modulation and systematic filter design approach for a single-stage dual-active-bridge (DAB) based dc-ac microinverter to achieve improved differential-mode (DM) noise performance for electromagnetic interference (EMI) tests. As DM filters contribute significantly to the overall converter volume, the main objective of this work is to leverage the degrees of freedom in the DAB converters to effectively attenuate the EMI noise. In addition, the DM filter design method needs to ensure near unity power factor converter operation. To achieve these targets, this paper analyzes three modulation strategies based on fixed or variable switching frequency operation where the different control modulation variables are varied to find the simulated DM noise spectrum. Based on the required DM attenuation, a constrained optimization problem is formulated to determine minimal DM filter parameters. Simulation results show that a spread spectrum approach with variable switching frequency is shown to minimize the DM EMI attenuation effort by spreading the noise profile. A fully GaN 400 W hardware prototype demonstrated the spread-sprectrum approach.

14 SOLAR ENERGY↗

Radiological Source Term Estimation and Isotopic Identification with Parallel Log Domain Particle Filters

This paper presents a parallel log-domain particle filtering algorithm combined with gamma spectrum unfolding to perform localization, identification, and evaluation of multiple point sources of various isotopes in an environment with attenuating obstacles. The method uses sets of precomputed attenuation kernels that map the attenuation characteristics of the environment. These kernels are specific to the energy level of a photopeak of interest. The spectral measurements are deconvolved into count measurements of each photopeak. These count measurements are fed into a set of parallel particle filters using attenuation kernels computed for that photopeak’s energy level. The individual regularized particle filters perform all likelihood calculations in the logarithmic domain to mitigate the effects of particle degeneracy. The output of each particle filter is combined to estimate which isotopes are present as well as their positions and strengths. The performance of the algorithm is characterized in a lab-scale environment using a mobile robot equipped with a gamma ray spectrometer in the presence of up to three different radioactive isotopes simultaneously. The sources were localized to within 10 cm, and their strengths were estimated within 10% of their true values. Furthermore, the isotopes were all correctly identified, and no spurious sources were reported.

42 ENGINEERING↗

Autodifferentiable Ensemble Kalman Filters

Data assimilation is concerned with sequentially estimating a temporally evolving state. This task, which arises in a wide range of scientific and engineering applications, is particularly challenging when the state is high-dimensional and the state-space dynamics are unknown. This paper introduces a machine learning framework for learning dynamical systems in data assimilation. Here, our auto-differentiable ensemble Kalman filters (AD-EnKFs) blend ensemble Kalman filters for state recovery with machine learning tools for learning the dynamics. In doing so, AD-EnKFs leverage the ability of ensemble Kalman filters to scale to high-dimensional states and the power of automatic differentiation to train high-dimensional surrogate models for the dynamics. Numerical results using the Lorenz-96 model show that AD-EnKFs outperform existing methods that use expectation-maximization or particle filters to merge data assimilation and machine learning. In addition, AD-EnKFs are easy to implement and require minimal tuning.

autodifferentiation↗

Bloom filters for molecules

Abstract Ultra-large chemical libraries are reaching 10s to 100s of billions of molecules. A challenge for these libraries is to efficiently check if a proposed molecule is present. Here we propose and study Bloom filters for testing if a molecule is present in a set using either string or fingerprint representations. Bloom filters are small enough to hold billions of molecules in just a few GB of memory and check membership in sub milliseconds. We found string representations can have a false positive rate below 1% and require significantly less storage than using fingerprints. Canonical SMILES with Bloom filters with the simple FNV (Fowler-Noll-Voll) hashing function provide fast and accurate membership tests with small memory requirements. We provide a general implementation and specific filters for detecting if a molecule is purchasable, patented, or a natural product according to existing databases at https://github.com/whitead/molbloom .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗