Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FeN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Relative Rates for Plasma Homo- and Copolymerizations of Olefins in a Homologous Series of Fluorinated Ethylenes

The relative rates of plasma (co)polymerizations of ethylene, vinyl fluoride, vinylidene fluoride, trifluoroethylene and tetrafluoroethylene (VF(sub x); x = 0-4, respectively) were determined in an rf, capacitively coupled, tubular reactor with external electrodes using identical plasma parameters. The averages of deposition rates obtained by both microgravimetry and ellipsometry were plotted versus the F/C ratios of the monomers or monomer blends. The deposition rates for VF(sub x)(x = 1-3) and 20 monomer blends were all located above a straight line joining the rates for VF(sub 0) and VF(sub 4), following a concave-downward plot of deposition rate versus F/C ratio similar to that reported previously for VF(sub 0)/VF(sub 4) blends. The deposition rates for VF(sub m)/VF(sub n) blends (m = 3 or 4; n = 0-2) were all greater than expected for non-interacting monomers; those for VF(sub 0)/VF(sub 2) and VF(sub 1)/VF(sub 2) blends were all lower than expected; while those for VF(sub 0)/VF(sub 1) and VF(sub 3)/VF(sub 4) blends fen on a straightline plot versus F/C ratio, indicative of apparent non-interaction between monomers. The mechanisms for plasma (co)polymerizations of VF(sub x) monomers responsible for the wide range of relative deposition rates remain to be elucidated.

Golub, Morton A.↗

Climate Controls on Carbon Sequestration in Eastern North America

Mid-latitude forest ecosystems have been proposed as a "missing sink" today. The role of soils (including wetlands) in this proposed sink is a very important unknown. In order to make estimates of future climate change effects on carbon storage, we can examine past wetland carbon sequestration. How did past climate change affect net wetland carbon storage? We present long-term data from existing wetland sites used for paleoclimate reconstruction to assess the net carbon storage in wetland over the last 15000 years. During times of colder and wetter climate, many mid-latitude sites show increases in carbon storage, while past warmer, drier climates produced decreases in storage. Comparison among bog, fen, swamp, and tidal marsh are demonstrated for the Hudson Valley region.

Peteet, D. M.↗

Bryce Canyon Water Resources: Monitoring Vegetation Health and Water Availability in Bryce Canyon National Park for Drought Stress Mitigation Planning

Bryce Canyon National Park is home to groundwater-dependent ecosystems (GDEs) that are threatened by a multidecadal drought and increased groundwater extraction due to a spike in tourism. These ecosystems contain unique species that are only found in areas where near-surface groundwater is present, such as aspen groves and fens. These species contribute to the high biodiversity found in Bryce Canyon, which boosts an ecosystem’s productivity and the services it provides to the park. Unfortunately, many of these GDEs are too small to identify with traditional Earth observation platforms and are difficult to physically reach for monitoring purposes. This project partnered with the National Park Service to identify springs and seeps as a proxy for GDEs within Bryce Canyon from 2013–2022. Furthermore, this project tested the feasibility of various methods to detect and monitor springs and seeps and therefore facilitate the partner’s efforts to conserve these ecologically valuable GDEs in Bryce Canyon. The team mapped groundwater discharge with high resolution National Agriculture Imagery Program (NAIP) and assessed park vegetation trends with Landsat 8 Operational Land Imager (OLI) and PlanetScope imagery. In-situ precipitation data and the Western Land Data Assimilation System (WLDAS) were used to produce time series of climatic variables. Seeps and spring locations were predicted using random forest classification and maximum entropy machine learning models.

Groundwater dependent ecosystems↗

A method for coupling a parameterization of the planetary boundary layer with a hydrologic model

Deardorff's parameterization of the planetary boundary layer is adapted to drive a hydrologic model. The method converts the atmospheric conditions measured at the anemometer height at one site to the mean values in the planetary boundary layer; it then uses the planetary boundary layer parameterization and the hydrologic variables to calculate the fluxes of momentum, heat and moisture at the atmosphere-land interface for a different site. A simplified hydrologic model is used for a simulation study of soil moisture and ground temperature on three different land surface covers. The results indicate that this method can be used to drive a spatially distributed hydrologic model by using observed data available at a meteorological station located on or nearby the site.

Lin, J. D.↗

Electrical Properties of Materials for Elevated Temperature Resistance Strain Gage Application

The objective was to study the electrical resistances of materials that are potentially useful as resistance strain gages at 1000 C. Transition metal carbides and nitrides, boron carbide and silicon carbide were selected for the experimental phase of this research. Due to their low temperature coefficient of resistance and good stability, TiC, ZrC, B sub 4 C and beta-SiC are suggested as good candidates for high temperature resistance strain gage applications.

Lei, Jih-Fen↗

Learning dominance relations in combinatorial search problems

Dominance relations commonly are used to prune unnecessary nodes in search graphs, but they are problem-dependent and cannot be derived by a general procedure. The authors identify machine learning of dominance relations and the applicable learning mechanisms. A study of learning dominance relations using learning by experimentation is described. This system has been able to learn dominance relations for the 0/1-knapsack problem, an inventory problem, the reliability-by-replication problem, the two-machine flow shop problem, a number of single-machine scheduling problems, and a two-machine scheduling problem. It is considered that the same methodology can be extended to learn dominance relations in general.

Yu, Chee-Fen↗

Laboratory simulation of cometary neutral gas ionization

The laboratory simulation of the interaction of the solar wind with a comet is used to study the cometary neural gas ionization. The experiment is carried out in the UCR T-1 facility with an ice ball as the comet model. Photographs and data are taken with a variety of values of the solar wind velocity, interplanetary magnetic field (IMF), and comet configurations. The results show that the cometary neutral gas ionization depends on both the velocity of the solar wind and the interplanetary magnetic field. The plasma cloud surrounding the comet is visible only when the solar wind velocity and IMF are both above certain minimum values. This velocity dependent phenomena is explained by Alfven's critical ionization velocity effect. The critical magnetic field may be explained by assuming two stream lower hybrid instability as a triggering mechanism for the ionization of the neutral gas by plasma flow. Critical upper and lower limits for the magnetic field, required by anomalous ionization, are also derived that satisfy the experimental observations.

Chang, Tsuey-Fen↗

Development and characterization of PdCr temperature-compensated wire resistance strain gage

A temperature-compensated resistance static strain gage with potential to be used to 600 C was recently developed. Gages were fabricated from specially developed palladium-13 w/o chromium (Pd-13Cr) wire and platinum (Pt) compensator. When bonded to high temperature Hastelloy X, the apparent strain from room temperature to 600 C was within 400 microstrain for gages with no preheat treatment and within 3500 microstrain for gages with 16 hours prestabilization at 640 C. The apparent strain versus temperature relationship of stabilized PdCr gages were repeatable with the reproducibility within 100 microstrain during three thermal cycles to 600 C and an 11 hours soak at 600 C. The gage fabrication, construction and installation is described. Also, the coating system used for this compensated resistance strain gage is explained. The electrical properties of the strain sensing element and main characteristics of the compensated gage including apparent strain, drift and reproducibility are discussed.

Lei, Jih-Fen↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 800 C

A temperature compensated static strain gage, which is fabricated from palladium-13w/o chromium (Pd13Cr) alloy and a platinum (Pt) compensator, is being developed and was tested over a temperature range to 800 C at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 800 C than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4w/o zirconia overcoating. Test results to 800 C indicate apparent strain variations of less than 300 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. Apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

The apparent strain stability and repeatability of a BCL3 resistance strain gage

Experiments were conducted at NASA-Lewis to study the effect of microstructural instability on the apparent strain stability and reproducibility of a BCL3 resistance strain gage. The resistance drift of the gage at various temperatures in the phase transition temperature range (PTTR) was measured. The effects of the heating and cooling rates with which the gage passed through the PTTR on the apparent strain characteristics of the gage were also studied. BCL3 gage, like other Fe-Cr-Al based gages, exhibited apparent strain instability in the temperature range of 700 to 1100 F due to the reversible microstructural transition the gage materials experienced in this temperature range. The BCL3 gage had a maximum apparent strain drift in the neighborhood of 770 F with an average drift rate of approx. -440 microstrain/hr in 2 hrs. The use of the BCL3 gage as well as other Fe-Cl-Al based gages for static strain measurements within the PTTR should be avoided unless the time durations in the PTTR are small enough to introduce a neglible drift. The microstructure transition that the BCL3 gage underwent occurred in the temperature range of 750 to 1050 F during heating and around 1000 to 800 F during cooling. The heating rate, and, in particular, the cooling rate with which the gage passed through the PTTR affected the shape and the repeatability of the apparent strain curve of the gage.

Lei, Jih-Fen↗

PdCr based high temperature static strain gage

The program at NASA Lewis Research Center to develop a high temperature static strain gage system for the hypersonic vehicle and turbine engine research has emphasized a palladium-13 wt pct chromium (PdCr) alloy. Gages made from this alloy are being developed in both fine wire and thin film form. The wire gage system had platinum wire as a temperature compensator and was coated with a special alumina and zirconia mixture overcoat. This PdCr compensated wire gage responded linearly to the imposed strain to at least 1000 microstrain. The apparent strain varied within 300 microstrain from room temperature to 800 C with a reproducibility within 50 microstrain between thermal cycles to 800 C. The sputtered thin film PdCr strain gage, whose size was 8 x 8 mm and 10 microns thick, has demonstrated the possibility of extending the use of the PdCr strain gage to a temperature of approximately 1000 C.

Lei, Jih-Fen↗

A resistance strain gage with repeatable and cancellable apparent strain for use to 1500 F

A temperature compensated static strain gauge, which is fabricated from Pd13Cr alloy and a Pt compensator, is being developed and has been tested over a temperature range to 1500 F at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 500 F than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4 wt pct zirconia overcoating. Test Results to 1500 F indicate apparent strain variations of less than 250 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. The apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

Pd/Cr Strain Gauges For High Temperatures

Temperature-compensated Pd/Cr electrical-resistance strain gauges measure static strains in combustors, blades, and vanes of gas turbine engines. Made of alloy of 87 weight percent Pd and 13 weight percent Cr. Microstructure highly stable; undergoes no transformation of phase between ambient temperature and 1,000 degrees C. Gives highly repeatable readings with low drift at temperatures from ambient to 600 degrees C.

Lei, Jih-Fen↗

Protective Coats For High-Temperature Strain Gauges

Addition of some rare-earth oxides to prior alumina (only) coating material increases maximum service temperature of palladium/chromium-wire strain gauges. Pd/Cr wires used at temperatures up to 800 degrees C without excessive drift in electrical resistance. Oxides used: zirconia (ZrO2), yttria (Y2O3), ceria (CeO2), and hafnia (HfO2). Addition of one of these oxides to decrease oxidation of wire at high temperature. Protection against oxidation increases with concentration of rare-earth oxide. Addition of ZrO2 at 4 to 6 weight percent or Y2O3 at 1 weight percent results in smallest drift in electrical resistance.

Lei, Jih-Fen↗

Palladium-chromium static strain gages for high temperatures

An electrical resistance strain gage that can provide accurate static strain measurement to a temperature of 1500 F or above is being developed both in fine wire and thin film forms. The gage is designed to be temperature compensated on any substrate material. It has a dual element: the gage element is a special alloy, palladium-13wt percent chromium (PdCr), and the compensator element is platinum (Pt). Earlier results of a PdCr based wire gage indicated that the apparent strain of this gage can be minimized and the repeatability of the apparent strain can be improved by prestabilizing the gage on the substrate for a long period of time. However, this kind of prestabilization is not practical in many applications and therefore the development of a wire gage which is prestabilized before installation on the substrate is desirable. This paper will present our recent progress in the development of a prestabilized wire gage which can provide meaningful strain data for the first thermal cycle. A weldable PdCr gage is also being developed for field testing where conventional flame-spraying installation can not be applied. This weldable gage is narrower than a previously reported gage, thereby allowing the gage to be more resistant to buckling under compressive loads. Some preliminary results of a prestabilized wire gage flame-sprayed directly on IN100, an engine material, and a weldable gage spot-welded on IN100 and SCS-6/(beta)21-S Titanium Matrix Composite (TMC), a National Aero-Space Plane (NASP) structure material, will be reported. Progress on the development of a weldable thin film gage will also be addressed. The measurement technique and procedures and the lead wire effect will be discussed.

Lei, Jih-Fen↗

Palladium-chromium static strain gage for high temperature propulsion systems

The present electrical strain gage for high temperature static strain measurements is in its fine-wire and thin-film forms designed to be temperature-compensated on any substrate material. The gage element is of Pd-Cr alloy, while the compensator is of Pt. Because the thermally-induced apparent strain of this compensated wire strain gage is sufficiently small, with good reproducibility between thermal cycles to 800 C, output figures can be corrected within a reasonable margin of error.

Lei, Jih-Fen↗

High temperature static strain measurement with an electrical resistance strain gage

An electrical resistance strain gage that can supply accurate static strain measurement for NASP application is being developed both in thin film and fine wire forms. This gage is designed to compensate for temperature effects on substrate materials with a wide range of thermal expansion coefficients. Some experimental results of the wire gage tested on one of the NASP structure materials, i.e., titanium matrix composites, are presented.

Lei, Jih-Fen↗

High-Temperature Resistance Strain Gauges

Resistance strain gauges developed for use at high temperatures in demanding applications like testing aircraft engines and structures. Measures static strains at temperatures up to 800 degrees C. Small and highly reproducible. Readings corrected for temperature within small tolerances, provided temperatures measured simultaneously by thermocouples or other suitable devices. Connected in wheatstone bridge.

Lei, Jih-Fen↗