Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fault mitigation strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Creating Formal Characterizations ofRoutine Contingency Management inCommercial Aviation

Traditional approaches to safety management focus on collection of data describing unwanted states (i.e., accidents and incidents) and analysis of undesired behaviors (i.e., faults and errors) that precede those states. Thus, in the traditional view of safety, safety is both defined and measured by its absence, namely the lack of safety. In extremely high confidence systems like commercial air transport, however, opportunities to measure the absence of safety are relatively rare. Ironically, a critical barrier to measuring safety and the impact of mitigation strategies in commercial aviation is the lack of opportunities for measurement.

Intelligent Contingency Management,↗

Autoencoder-Based Sensor Drift Detection and Mitigation for Resilient Charging Systems

This work presents an autoencoder-based approach for sensor signal reconstruction and drift detection for charging systems. The proposed strategy is implemented within a Simulink-based system framework and evaluated under multiple operating conditions. An autoencoder with 8 neurons in the bottleneck layer is adopted, achieving accurate reconstruction across 10 variables and strong agreement with the physical sensor readings under normal conditions. In the case of a sensor fault, the autoencoder reconstruction remains closer to the expected true value compared to the corrupted measurement. Furthermore, feeding the autoencoder-reconstructed signal value back into the control framework in place of the faulty sensor signal leads to improved power monitoring. These results highlight the potential of autoencoder-based virtual sensing to extend the concept of resiliency to all components of the charging system, including sensors.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

5-2428: Coupled Investigation of Fracture Permeability Impact on Reservoir Stress and Seismic Slip Behavior [Slides]

Our goal is to develop, apply and validate a holistic thermal, hydrologic, mechanical, and chemical (THMC) workflow that also includes evaluation of induced seismic slip in EGS reservoirs. We will integrate experimental and modelling approaches to reduce parameter uncertainty and better integrate friction constitutive laws for faults to improve our ability to predict and mitigate seismic hazard at Utah FORGE and future EGS sites. We propose a novel approach that incorporates 3D physics-based Earthquake simulations in THMC models, using lab measurements of friction parameters, herein referred to as “THMC+E” models. These simulations will enable exploration of various circumstances that may hinder EGS success and develop mitigation strategies.

58 GEOSCIENCES↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrified Aircraft Propulsion Systems: Gas Turbine Control Considerations for the Mitigation of Potential Failure Modes and Hazards

This paper provides a high-level review of the potential failure modes and hazards to which electrified aircraft propulsion (EAP) systems are susceptible along with potential gas turbine control-based strategies to assist in the mitigation of those failures. To introduce the types of failures that an EAP system may experience, a generic EAP system is considered consisting of gas turbine engines, mechanical drives, electric machines, power electronics and distribution systems, energy storage devices, and motor driven propulsors. The functionality provided by each of these EAP subsystems is discussed along with their potential failure modes and possible strategies for mitigating those failures. To further illustrate the role of gas turbine controls in mitigating EAP failure modes, an example based on a simulated EAP concept aircraft proposed by NASA is given. The effects of failures are discussed, along with turbomachinery control strategies, including reversionary control modes, and control limit logic

Electrified Aircraft Propulsion↗

Active Swarm Resiliency in the HelioSwarm Mission

Designed to observe plasma turbulence dynamics in solar wind over a distributed volume of space, the HelioSwarm mission comprises a primary chief spacecraft and eight smaller deputy satellites in uniquely assigned “loops” of periodic relative motion in a P/2 lunar resonant orbit. If one or more deputies fail, this multi-satellite architecture facilitates resiliency for science goals through repositioning of satellites to contingency loops. This strategy of Active Swarm Resiliency mitigates risk by modeling quantitative results ahead of time for mission operators to make informed decisions. Responsive actions meet minimum science objectives based on past and predicted system performance, an approach with applications to future missions with similar architecture and requirements.

Fault Management↗

Active Swarm Resiliency in the HelioSwarm Mission

Designed to observe plasma turbulence dynamics in solar wind over a distributed volume of space, the HelioSwarm mission comprises a primary chief spacecraft and eight smaller deputy satellites in uniquely assigned “loops” of periodic relative motion in a P/2 lunar resonant orbit. If one or more deputies fail, this multi-satellite architecture facilitates resiliency for science goals through repositioning of satellites to contingency loops. This strategy of Active Swarm Resiliency mitigates risk by modeling quantitative results ahead of time for mission operators to make informed decisions. Responsive actions meet minimum science objectives based on past and predicted system performance, an approach with applications to future missions with similar architecture and requirements.

Fault Management↗

Developing a Disaster-Ready Power Grid Agent Through Geophysically-Informed Fault Event Scenarios

Management of the nation’s power grid over the coming decades will need to factor multiple climate-driven threats to the power system that can be stressful or even detrimental to its operations. During disasters, grid operators suffer from cognitive overload where the electric grid is severely impacted by the weather, yet grid operators have limited awareness of these factors. Meanwhile, the electric grid is facing an explosion of data coming from a variety of sources which can enable the operator to evaluate the risks and develop mitigation strategies against hazardous events. In this work, we processed heterogeneous environmental and power grid data to learn and model grid behavior caused by extreme weather events. In this study, we focused on two weather-driven hazards, hurricanes and wildfires, which were analysed for the electric grid of Texas. We the used this data to train a Reinforcement Learning (RL) agent by analysing and predicting future behaviour of the grid during those hazard events. All these parts are incorporated in one framework to have a geophysically informed power simulators that can be used to train RL agents.

electic grid, reinforcement learning, climate adap↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/dis-turbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

distributed energy resources (DERs)↗

Dynamic Distribution System Restoration Strategy for Resilience Enhancement: Preprint

In electric power distribution systems, distributed energy re-sources (DERs) can act as controllable power sources and support utility operators to minimize power outages after ex-treme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influ-ences of extreme events and the capabilities of DERs are dy-namic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availabil-ity of DERs. In this paper, we propose a new dynamic distribu-tion system restoration strategy to enhance system resilience against potential hazards. An efficient reconfiguration algo-rithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER opera-tion setpoints based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Failure Behavior and Control Based Mitigation for a Parallel Hybrid Propulsion System

NASA is pursuing research to advance Electrified Aircraft Propulsion (EAP) technologies that address fuel burn and emission reduction goals. EAP brings the potential for improved performance over the state of the art. However, for these systems to be practical and certifiable, they need to possess adequate robustness to adverse conditions including a variety of system failures that are not applicable to conventional turbofans today. Numerous EAP concepts interface gas turbine engines with an electrical power system that includes electric machines and sometimes electrical energy storage. The expansion of the powertrain increases the probability of encountering a failure and introduces new failure modes. Failures within the electrical power system may also impact the gas turbine engine(s) to which the electrical powertrain is coupled. This effort investigates failures originating in the electrical power system and their impact on the parallel hybrid propulsion system. Reversionary control strategies are also demonstrated to reduce the impact of the failures. Failure mitigation strategies were devised and employed in simulation. Various failure scenarios were simulated including those occurring during steady state operation, transients, and takeoff and landing scenarios. The timing of the failure and delay in failure identification and activation of mitigation strategies are noteworthy variables in the study. While the system remained stable throughout all failure scenarios, delays in failure identification could result in undesirable conditions such as increased operating temperatures and reduced stall margin. The results demonstrate successful mitigation of failures through reversionary control modes and help to generate confidence in the robustness of the conceptual parallel hybrid propulsion system.

Failure behavior↗

Failure Behavior and Control-Based Mitigation for a Parallel Hybrid Propulsion System

NASA is pursuing research to advance Electrified Aircraft Propulsion (EAP) technologies that address fuel burn and emission reduction goals. EAP brings the potential for improved performance over the state of the art. However, for these systems to be practical and certifiable, they need to possess adequate robustness to adverse conditions including a variety of system failures that are not applicable to conventional turbofans today. Numerous EAP concepts interface gas turbine engines with an electrical power system that includes electric machines and sometimes electrical energy storage. The expansion of the powertrain increases the probability of encountering a failure and introduces new failure modes. Failures within the electrical power system may also impact the gas turbine engine(s) to which the electrical powertrain is coupled. This effort investigates failures originating in the electrical power system and their impact on the parallel hybrid propulsion system. Reversionary control strategies are also demonstrated to reduce the impact of the failures. Failure mitigation strategies were devised and employed in simulation. Various failure scenarios were simulated including those occurring during steady state operation, transients, and takeoff and landing scenarios. The timing of the failure and delay in failure identification and activation of mitigation strategies are noteworthy variables in the study. While the system remained stable throughout all failure scenarios, delays in failure identification could result in undesirable conditions such as increased operating temperatures and reduced stall margin. The results demonstrate successful mitigation of failures through reversionary control modes and help to generate confidence in the robustness of the conceptual parallel hybrid propulsion system.

Failure behavior↗

Innovations in underground hydrogen storage with multiphysics simulations, optimization, and monitoring: A review

Underground Hydrogen Storage (UHS) is a promising solution for large-scale energy storage and a critical component in advancing low-carbon energy system. Ensuring the safety and efficiency of UHS necessitates a comprehensive understanding of multiphysical interactions driven by cyclic pore fluid pressure fluctuations and coupled physicochemical processes. Here, this review examines the key geomechanical responses in UHS, including rock property variations under cyclic loading, fracture evolution and propagation, reservoir stress sensitivity, and fault stability. It also explores the impact of geochemical and microbial reactions on geomechanical characteristics. We provide an in-depth analysis of Thermal-Hydraulic-Mechanical-Chemical (THMC) coupled numerical simulations, highlighting their potential for future multi-scale modeling. Limitations of current machine learning (ML) approaches in addressing UHS challenges are highlighted, emphasizing the need for innovative ML-based methodologies. Operational strategies for hydrogen injection and production are reviewed, focusing on safety, efficiency, and economic viability. The necessity for multi-objective optimization (MOO) to balance storage efficiency, risk mitigation, and cost-effectiveness is also discussed. Current monitoring technologies are evaluated to ensure safe and efficient UHS operations. Finally, this review identifies critical knowledge gaps and underscores the importance of advancing geomechanical understanding under multiphysics-coupling. We highlight the need for ML-driven multiphysics theories, enhanced modeling techniques, and robust optimization strategies to improve UHS performance. This study serves as a comprehensive reference for future research and the large-scale implementation of UHS systems.

25 ENERGY STORAGE↗

Failure Modes and Mitigation Strategies for a Turboelectric Aircraft Concept with Turbine Electrified Energy Management

The electrification of gas turbine engines represents a major step-change in aircraft propulsion systems commonly known as Electrified Aircraft Propulsion (EAP). EAP involves the integration of electric machines potentially functioning as generators for large scale power extraction, as motors providing electrical augmentation of the engine spools, and even as a means of driving propulsors beyond the immediate scope of the engine. It may also include the use of energy storage. These and other characteristics of hybrid electric propulsion systems are relatively new to aircraft propulsion. The expanded propulsion architecture can be leveraged to improve propulsive efficiency and achieve better vehicle aerodynamics and controllability. It can also allow for additional benefits such as those enabled through Turbine Electrified Energy Management (TEEM). As the propulsion system and its functions expand, new failure modes are introduced. Due to the highly coupled nature of the propulsion system, failures could propagate throughout the system in ways that are unique to the new EAP architectures. To build confidence in the safety and practicality of EAP concepts, these failure modes need to be identified, explored, and addressed through mitigation strategies. This paper seeks to evaluate failure modes and failure mitigation strategies for the EAP concept known as the Single aisle Turboelectric AiRCaft with Aft Boundary Layer propulsor (STARC-ABL). The TEEM control concept is applied to improve transient operability. Several failure modes are considered and control based failure mitigation strategies are proposed with the goal of retaining operability and overall thrust. The results demonstrate the ability to maintain operability and a substantial amount of thrust in the event of various types of failures. Some challenges are also identified and discussed.

Turbine Electrified Energy Management↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing the efficacy of active pressure management as a tool to mitigate induced seismicity

Manipulation of subsurface stresses through fluid injection/extraction may induce seismicity through modulation of overpressure along faults. Globally, most industrial operations do not induce significant earthquakes. However, the possibility of inducing moderate to large earthquakes is recognized as a significant risk for basin-scale carbon dioxide (CO 2 ) storage operations (Niass et al., 2017). One possible method to reduce the occurrence of induced seismicity is to maintain only small (or zero) fluid overpressure changes in the subsurface through extraction of formation brine. For active pressure management (APM), operators may employ different procedures including extraction of various brine volumes and different configurations of injection/extraction well locations. However, the impact each these operational procedures on induced seismicity must be understood in order to develop management strategies. Here, we describe a numerical modeling workflow to evaluate the efficacy of APM techniques, that when applied to a specific site may be used to inform operational management strategies. We couple the multiphase reservoir model, NUFT, with the earthquake simulator, RSQSim and simulate seismicity induced by CO 2 injection into a hypothetical brine saturated reservoir. Reservoir overpressure is modified by co-extraction of brine at various fractions of the injected CO 2 volume from five potential wells. Our goal is to understand how the well-pair configuration and the extracted brine volume impact the total number and the maximum event magnitude. Additionally, the performance of each scenario is also evaluated in terms of the volume of CO 2 that can be stored before an earthquake above a tolerance threshold is induced.

58 GEOSCIENCES↗

Evaluation and Improvement of System-of-Systems Resilience in a Simulation of Wildfire Emergency Response

Because of the increasing threat that wildfires pose, there is interest in leveraging new technologies to improve firefighting. Specifically, Unmanned Aerial Systems (UAS) and UAS Traffic Management (UTM) promise to improve firefighters’ situational awareness, coordination, communications, safety, and strategy. While these technologies could be beneficial, there has been little formal investigation into how much benefit would occur and whether these benefits would outweigh hazards introduced by these systems. To better understand the impacts of these technologies, this paper presents a high-level dynamic simulation for evaluating wildfire response performance and resilience incorporating fire propagation, surveillance and communication, response planning, and the resulting mitigation actions. This simulation is then used to study the impact of communications and surveillance improvement, considering (1) the effect on fire containment and ground crew injuries and (2) the effect of introduced and existing disruptive fault scenarios. Simulating this model over a large number of scenarios finds that these changes can improve containment and reduce ground crew injuries. While these improvements generalize over both existing and introduced single-fault scenarios and thus result in a more resilient system, they could be negated if the introduced communications infrastructure is prone to full-scale outages.

modeling↗