A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

CNN-Based Phase Fault Classification in Real and Simulated Power Systems Data

This study proposes a convolutional neural network (CNN)–based two-step phase fault detection and identification method to classify anomalies in the power grid signal. Specifically, the first step checks the fault’s existence and determines the need for the second step. Subsequently, in the case of anomalies in the power grid signal, the second step identifies the type of fault, including line-to-line, single-line-to-ground, double-line-to-ground, and triple-line. Accordingly, the CNN architecture is both designed for the classification layers and trained with simulated data. To provide maximum prediction accuracy with minimum processing time, this study investigates the combinations of various feature extraction (FE) techniques, such as fast Fourier transform (FFT), amplitude and phase (AP), auto-correlation function, power spectral density, and wavelet transform (WT). Consequently, simulated and real-world results demonstrate that the proposed two-step method outperforms conventional one-step techniques, with the best performance obtained by using the combination of AP-AP, AP-WT, FFT-AP, and FFT-WT–based FE methods.

Alaca, Ozgur↗

Fallon FORGE: Seismic Reflection Profiles

Newly reprocessed Naval Air Station Fallon (1994) seismic lines: pre-stack depth migrations, with interpretations to support the Fallon FORGE (Phase 2B) 3D Geologic model. Data along seven profiles (>100 km of total profile length) through and adjacent to the Fallon site were re-processed. The most up-to-date, industry-tested seismic processing techniques were utilized to improve the signal strength and coherency in the sedimentary, volcanic, and Mesozoic crystalline basement sections, in conjunction with fault diffractions in order to improve the identification and definition of faults within the study area.

15 GEOTHERMAL ENERGY↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

PERLE: A High Power Energy Recovery Facility

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Kaabi, W.↗

SRF Cavity Fault Classification Using Machine Learning At CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Solopova, A.↗

SRF Cavity Fault Classification Using Machine Learning At CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Solopova, A.↗

Statistical Fault Detection for Parallel Applications with AutomaDeD

Today's largest systems have over 100,000 cores, with million-core systems expected over the next few years. The large component count means that these systems fail frequently and often in very complex ways, making them difficult to use and maintain. While prior work on fault detection and diagnosis has focused on faults that significantly reduce system functionality, the wide variety of failure modes in modern systems makes them likely to fail in complex ways that impair system performance but are difficult to detect and diagnose. This paper presents AutomaDeD, a statistical tool that models the timing behavior of each application task and tracks its behavior to identify any abnormalities. If any are observed, AutomaDeD can immediately detect them and report to the system administrator the task where the problem began. This identification of the fault's initial manifestation can provide administrators with valuable insight into the fault's root causes, making it significantly easier and cheaper for them to understand and repair it. Our experimental evaluation shows that AutomaDeD detects a wide range of faults immediately after they occur 80% of the time, with a low false-positive rate. Further, it identifies weaknesses of the current approach that motivate future research.

99 GENERAL AND MISCELLANEOUS↗

AI-enabled traveling wave protection for microgrids

Grid forming inverters provide voltage and frequency regulations for microgrids; in the meantime, new challenges are introduced for microgrid protections. For instance, inverters’ control strategies can affect protection behaviors, and low short-circuit ratios and bi-directional power flows also make protection operations complex. Protection schemes based on conventional principles such as overcurrent and distance relays do not always provide reliable, sensitive, or selective operations. Here, we devise a traveling wave protection approach for microgrids using a wavelet-driven deep neural network named WaveletKernelNet (WKN). Compared with conventional methods, the presented approach provides enhanced sensitivity, higher selectivity, and better identification of various faults in microgrids. Extensive case studies validate the efficacy and excellent performance of the devised approach.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Relocating microseismicity from downhole monitoring of the Decatur CCS site using a modified double-difference algorithm

SUMMARY The injection of CO2 at the Decatur carbon capture and storage site has generated significant microseismic activity, which occurs in distinct spatial clusters up to approximately 2.2 km from the primary injection well. Accurate and precise event locations are vital for the characterization of the microseismicity to help understand the reservoir response to the CO2 injection, whilst enabling the identification of minor faults and fractures below the resolution of conventional active seismic imaging. However, microseismic monitoring of fluid injection sites, such as Decatur, is often performed using a network of borehole sensors often from a single well. While these downhole sensors have excellent detection capabilities, their poor azimuthal coverage limits the ability to precisely determine event locations. We have developed a modified double-difference relocation algorithm suitable for both 1-D and 3-D velocity models, and which incorporates differential back azimuth observations to allow the benefits of the original double-difference algorithm to be applicable to a downhole microseismic monitoring setting. Applying the modified double-difference algorithm to the microseismicity at Decatur, we have successfully relocated 4293 events. The relocation included over 59 million observations for 757 285 event pairs, split across seven geographic regions. Despite the majority of observations being recorded in only two boreholes, with an almost identical azimuthal coverage, the results have shown to be reliable with significantly reduced residuals and low uncertainties associated with the final locations. We have analysed the residuals in terms of their association with each geographic region, data type, station and individual events, to fully appreciate their influence in the inversion and the fit of the data to the final set of event locations. For each region, the relocated seismicity has become less diffuse with improved clustering, and with newly visible linear features often orientated in a NE–SW direction. These results show the potential improvements that can be made to microseismic event locations recorded by a borehole network with a limited and variable azimuthal distribution.

58 GEOSCIENCES↗

IBR Short Circuit Modeling in ETAP

Mohammad Zadeh from ETAP presented various modeling improvements that included the following: • Address convergence issues by using complete Norton Equivalent model including the IBR series filter impedance. • Fault ride through identification within iterations while short circuit results have not been converged and how that may impact final SC results. • Options for FRT curve 1- using a timer to lock FRT logic vs a hysteresis in FRT curve to avoid unwanted toggling. • Report recent co-operation between software vendors (Aspen, CAPE and ETAP) for adopting a C++ interface for IBR blackbox SC modeling. There was lot of interest to know about the model improvements that are being considered.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Learning Based Superconducting Radio-Frequency Cavity Fault Classification at Jefferson Laboratory

This work investigates the efficacy of deep learning (DL) for classifying C100 superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a large, high-power continuous wave recirculating linac that utilizes 418 SRF cavities to accelerate electrons up to 12 GeV. Recent upgrades to CEBAF include installation of 11 new cryomodules (88 cavities) equipped with a low-level RF system that records RF time-series data from each cavity at the onset of an RF failure. Typically, subject matter experts (SME) analyze this data to determine the fault type and identify the cavity of origin. This information is subsequently utilized to identify failure trends and to implement corrective measures on the offending cavity. Manual inspection of large-scale, time-series data, generated by frequent system failures is tedious and time consuming, and thereby motivates the use of machine learning (ML) to automate the task. This study extends work on a previously developed system based on traditional ML methods (Tennant and Carpenter and Powers and Shabalina Solopova and Vidyaratne and Iftekharuddin, Phys. Rev. Accel. Beams, 2020, 23, 114601), and investigates the effectiveness of deep learning approaches. The transition to a DL model is driven by the goal of developing a system with sufficiently fast inference that it could be used to predict a fault event and take actionable information before the onset (on the order of a few hundred milliseconds). Because features are learned, rather than explicitly computed, DL offers a potential advantage over traditional ML. Specifically, two seminal DL architecture types are explored: deep recurrent neural networks (RNN) and deep convolutional neural networks (CNN). We provide a detailed analysis on the performance of individual models using an RF waveform dataset built from past operational runs of CEBAF. In particular, the performance of RNN models incorporating long short-term memory (LSTM) are analyzed along with the CNN performance. Furthermore, comparing these DL models with a state-of-the-art fault ML model shows that DL architectures obtain similar performance for cavity identification, do not perform quite as well for fault classification, but provide an advantage in inference speed.

97 MATHEMATICS AND COMPUTING↗

Crossing Active Faults on the Sakhalin II Onshore Pipeline Route: Pipeline Design and Risk Analysis

Twin oil (20 and 24 inch) and gas (20 and 48 inch) pipeline systems stretching 800 km are being constructed to connect offshore hydrocarbon deposits from the Sakhalin II concession in the North to an LNG plant and oil export terminal in the South of Sakhalin island. The onshore pipeline route follows a regional fault zone and crosses individual active faults at 19 locations. Sakhalin Energy, Design and Construction companies took significant care to ensure the integrity of the pipelines, should large seismic induced ground movements occur during the Operational life of the facilities. Complex investigations including the identification of the active faults, their precise location, their particular displacement values and assessment of the fault kinematics were carried out to provide input data for unique design solutions. Lateral and reverse offset displacements of 5.5 and 4.5 m respectively were determined as the single-event values for the design level earthquake (DLE) - the 1000-year return period event. Within the constraints of a pipeline route largely fixed, the underground pipeline fault crossing design was developed to define the optimum routing which would minimize stresses and strain using linepipe materials which had been ordered prior to the completion of detailed design, and to specify requirements for pipe trenching shape, materials, drainage system, etc. Detailed Design was performed with due regard to actual topography and to avoid the possibility of the trenches freezing in winter, the implementation of specific drainage solutions and thermal protection measures.

58 GEOSCIENCES↗

Crossing Active Faults on the Sakhalin II Onshore Pipeline Route: Analysis Methodology and Basic Design

Twin oil (20 and 24 inch) and gas (20 and 48 inch) pipeline systems stretching 800 km are being constructed to connect offshore hydrocarbon deposits from the Sakhalin II concession in the North to an LNG plant and oil export terminal in the South of Sakhalin island. The onshore pipeline route follows a regional fault zone and crosses individual active faults at 19 locations. Sakhalin Energy, Design and Construction companies took significant care to ensure the integrity of the pipelines, should large seismic induced ground movements occur during the Operational life of the facilities. Complex investigations including the identification of the active faults, their precise location, their particular displacement values and assessment of the fault kinematics were carried out to provide input data for unique design solutions. Lateral and reverse offset displacements of 5.5 and 4.5 m respectively were determined as the single-event values for the design level earthquake (DLE)--the 1000-year return period event. Within the constraints of a pipeline route largely fixed, the underground pipeline fault crossing design was developed to define the optimum routing which would minimize stresses and strain using linepipe materials which had been ordered prior to the completion of detailed design, and to specify requirements for pipe trenching shape, materials, drainage system, etc. This Paper describes the steps followed to formulate the concept of the special trenches and the analytical characteristics of the Model.

58 GEOSCIENCES↗

Pre-trained network-based transfer learning: A small-sample machine learning approach to nuclear power plant classification problem

Some research topics belonging to classification problems in the nuclear industry, such as fault diagnosis and accident identification, can be solved by feature extraction and subsequent application of statistical machine learning classifiers. Recently, deep neural network-based methods with automatic feature extraction and high accuracy have gained wide attention. They usually require large-scale training data, however, plant fault or accident data are scarce or difficult to obtain. Here this paper proposes a convolutional network (CNN)-based transfer learning method to solve this problem. The network's shallow layer is derived from a pre-trained CNN based on the ImageNet database to automatically extract features, and the deep layer is customized to match the classification problem. Data in non-image formats are converted to image formats and subsequently used to train the network. Case studies of rotating machines fault diagnosis show that the proposed method requires only limited training data to achieve high accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Phasor Measurement Unit and Its Application in Modern Power Systems

The introduction of phasor measuring units (PMUs) in power systems significantly improves the possibilities for monitoring and analyzing power system dynamics. Synchronized measurements make it possible to directly measure phase angles between corresponding phasors in different locations within the power system. Improved monitoring and remedial action capabilities allow network operators to utilize the existing power system in a more efficient way. Improved information allows fast and reliable emergency actions, which reduces the need for relatively high transmission margins required by potential power system disturbances. In this chapter, the applications of PMU in modern power systems are presented. Specifically, the topics touched in this chapter include state estimation, voltage and transient stability, oscillation monitoring, event and fault detection, situation awareness, and model validation. A case study using Characteristic Ellipsoid method based on PMU to monitor power system dynamic is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗