Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FT VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cruise noise of an advanced single-rotation propeller measured from an adjacent aircraft

Results are reported from flight measurements of the noise from a full-scale SR-7L advanced single-rotation turbofan model mounted on the wing of the NASA Lewis Propfan Test Assessment (PTA) aircraft (a modified Gulfstream II). Data obtained on the PTA with an outboard microphone boom and by the NASA Lewis acoustically instrumented Learjet flying along several sidelines relative to the PTA are presented in tables and graphs and briefly discussed. It is found that the PTA-boom and Learjet sound levels are in good agreement at Mach 0.69 and altitude 20,000 ft, but the Learjet values are significantly lower than the boom levels at Mach 0.79 and altitude 36,000 ft.

Woodward, Richard P.↗

Temperature Profile Measurements in a Newly Constructed 30-Stage 5 cm Centrifugal Contactor pilot Plant

An annular centrifugal contactor pilot plant incorporating 30 stages of commercial 5 cm CINC V-02 units has been built and operated at INL during the past year. The pilot plant includes an automated process control and data acquisitioning system. The primary purpose of the pilot plant is to evaluate the performance of a large number of inter-connected centrifugal contactors and obtain temperature profile measurements within a 30-stage cascade. Additional solvent extraction flowsheet testing using stable surrogates is also being considered. Preliminary hydraulic testing was conducted with all 30 contactors interconnected for continuous counter-current flow. Hydraulic performance and system operational tests were conducted successfully but with higher single-stage rotor speeds found necessary to maintain steady interstage flow at flowrates of 1 L/min and higher. Initial temperature profile measurements were also completed in this configuration studying the performance during single aqueous and two-phase counter-current flow at ambient and elevated inlet solution temperatures. Temperature profile testing of two discreet sections of the cascade required additional feed and discharge connections. Lamp oil, a commercially available alkane mixture of C14 to C18 chains, and tap water adjusted to pH 2 were the solution feeds for all the testing described in this report. Numerous temperature profiles were completed using a newly constructed 30-stage centrifugal contactor pilot plant. The automated process control and data acquisition system worked very well throughout testing. Temperature data profiles for an array of total flowrates (FT) and contactor rpm values for both single-phase and two-phase systems have been collected with selected profiles and comparisons reported. Total flowrates (FT) ranged from 0.5-1.4 L/min with rotor speeds from 3500-4000 rpm. Solution inlet temperatures ranging from ambient up to 50° C were tested. Ambient temperature testing shows that a small amount of heat is added to the processed solution by the mechanical energy of the contactors. The temperature profiles match the ambient temperature of the laboratory but are nearly 10° C higher toward the middle of the cascade. Heated input solution testing provides temperature profiles with smaller temperature gradients and are more influenced by the temperature of the inlet solutions than the ambient laboratory temperature. The temperature effects of solution mixing, even at 4000 rpm, were insignificant in any of the studies conducted on lamp oil and water.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Factors influencing dry season ozone distributions over the tropical South Atlantic

Airborne measurements of trace gas and aerosol species were obtained in the lower troposphere (less than 5 km) over the western Atlantic Ocean between 13 deg S and 40 deg N during the August/September 1990 NASA Chemical Instrument Test and Evaluation (CITE 3) experiment. The largest background O3 mixing ratios, averaging 35 and 70 ppbv within the mixed layer (ML) and free troposphere (FT; altitudes greater than 2.4 km), respectively, were found over the tropical South Atlantic. Several competing processes were observed to regulate O3 budgets in this region. Within the ML, rapid photochemical destruction produced a diurnal O3 variation of 8 ppbv and an O3/altitude gradient between the surface and 5 km of almost 10 ppbv (O3)/km. ML O3 concentrations were replenished by atmospheric downwelling which occurred at rates of up to and exceeding 1 cm/s. Ozone values within the subsiding FT air were enriched both by long-range transport of O3 produced photochemically within biomass combustion plumes and the downward propagation of dry, upper tropospheric air masses. Overall, the tropospheric O3 column below 3.3 km averaged 13.5 Dobson units (DU) over the South Atlantic region, which is 8-9 DU higher than observed during CITE 3 ferry flights over the northern tropical Atlantic Ocean or measured by ozonesondes over coastal Brazil during the wet season. An examination of simultaneous dew point and combustion tracer (e.g., CO) measurements suggests that the dry subsiding layers and biomass burning layers make approximately equal contributions to the observed O3 enhancement.

Anderson, B. E.↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Geothermal Resources in Three Texas Counties

This project updates the geothermal resources beneath our oil and gas fields, as part of the research for the Texas GEO project. This report "Analysis of Geothermal Resources in Three Texas Counties" (October 2020) improves on previous mapping of the Texas resources for the counties of Crockett (West Texas), Jackson (central Gulf Coast) and Webb (South Texas). Through additional bottom-hole temperatures (BHT), the number of well sites increased from 532 to 5,410 in total for these counties. The improved methodology to calculate formation temperatures from 3.5 km (11,500 ft) to 10 km (32,800 ft) includes thermal conductivity values more closely related to the actual county geological formations, incorporated radiogenic heat production of formations, and the related mapped depth to basement. The results show deep temperatures as hotter than previously calculated, with temperatures of 150 degrees Celcius possible for Webb County between depths of 2.6 - 5.1 km, Jackson County between depths 3.0 - 5.4 km, and Crockett County between depths of 2.7 - 8.0 km.

10 km↗

Performance Characteristics of an Axial-flow Transonic Compressor Operating up to Tip Relative Inlet Mach Number of 1.34

Performance data are presented for a transonic axial-flow compressor rotor designed to operate at a tip speed of 1300 ft/sec with maximum relative tip Mach number of 1.37. The compressor had an inlet diameter of 16 inches, a hub-tip diameter ratio of 0.5 and design specific weight flow of 31.1 (lb/sec/(sq ft frontal area). Experimental values of relative total-pressure-loss coefficient were considerably higher than the assumed values. This disparity, hub choking, and application of the simple radial-equilibrium concept are discussed. The data of this report are used to extend previously presented correlation plots of compressor design parameters to higher Mach numbers.

Creagh, John W R↗

Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values

Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.

60 APPLIED LIFE SCIENCES↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Isotopic effect in experiments on lower hybrid current drive in the FT-2 tokamak

To analyze factors influencing the limiting value of the plasma density at which lower hybrid (LH) current drive terminates, the isotopic factor (the difference in the LH resonance densities in hydrogen and deuterium plasmas) was used for the first time in experiments carried out at the FT-2 tokamak. It is experimentally found that the efficiency of LH current drive in deuterium plasma is appreciably higher than that in hydrogen plasma. The significant role of the parametric decay of the LH pumping wave, which hampers the use of the LH range of RF waves for current drive at high plasma densities, is confirmed. It is demonstrated that the parameters characterizing LH current drive agree well with the earlier results obtained at large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microanalysis of carbonate cement δ 18 O in a CO 2 -storage system seal: Insights into the diagenetic history of the Eau Claire Formation (Upper Cambrian), Illinois Basin

Oxygen isotope (δ 18 O) zonation in carbonate mineral cements is often employed as a proxy record (typically with millimeter-scale resolution) of changing temperature regimes during different stages of sediment diagenesis. Recent advances in secondary ion mass spectrometry allow for highly precise and accurate determinations of cement δ 18 O values to be made in situ on a micrometer scale, thus significantly increasing the spatial resolution available to studies of diagenesis in sandstone–shale and carbonate systems. Chemo-isotopically zoned dolomite–ankerite cements within shaly sandstone beds of the predominantly silty–shaly Eau Claire Formation (Cambrian, Illinois Basin) were investigated, revealing the following: with increasing depth of burial (from <0.5 to ~2 km [<1500 to 6500 ft]), cement δ 18 O values decrease from a high of approximately 24‰ down to approximately 14‰ (on the Vienna standard mean ocean water [VSMOW] scale, equivalent to -6.5‰ to -16.5‰ on the Vienna Peedee belemnite [VPDB] scale). The observed cross-basin trend is largely consistent with cements having formed in response to progressive sediment burial and heating. Within the context of independent burial and thermal history models for the Illinois Basin, cementation began soon after deposition and continued intermittently into the mid-Permian. Finally, however, temperatures in excess of burial model predictions are inferred at the time of latest ankerite cement precipitation, which we propose overlapped in time with conductive heating of the Eau Claire Formation (a closed system) from under- and overlying sandstone aquifers that channeled the flow of hot, Mississippi Valley–type mineralizing brines during the mid-Permian (ca. 270 Ma).

58 GEOSCIENCES↗

High Performance Window Retrofit

The US Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and Traco partnered to develop high-performance windows for commercial building that are cost-effective. The main performance requirement for these windows was that they needed to have an R-value of at least 5 ft 2 ∙ F∙h/Btu. This project seeks to quantify the potential energy savings from installing these windows in commercial buildings that are at least 20 years old. To this end, we are conducting evaluations at a two-story test facility that is representative of a commercial building from the 1980s, and are gathering measurements on the performance of its windows before and after double-pane, clear-glazed units are upgraded with R5 windows. Additionally, we will use these data to calibrate EnergyPlus models that we will allow us to extrapolate results to other climates. Findings from this project will provide empirical data on the benefits from high-performance windows, which will help promote their adoption in new and existing commercial buildings. This report describes the experimental setup, and includes some of the field and simulation results.

EnergyPlus↗

Noise characteristics of the O-1 airplane and some approaches to noise reduction

A brief study of the O-1A airplane to determine possible means for reducing the aircraft aural detection distance was conducted. This effort involved measuring the noise signature of the basic airplane, devising methods to attenuate the noise, and then estimating the effect of several selected modifications on the aural detection distance of the aircraft. A relatively simple modification utilizing a 6.5 ft diameter, six-blade propeller and including a muffler having a volume of 0.725 cu ft is indicated to reduce the aural detection distance of the O-1 aircraft from about 6 miles at an altitude of 1,000 ft and 2 to 3 miles at an altitude of 300 ft to approximately half these values. The flyover noise data suggest that routing the exhaust stacks up and over the wing would provide immediate noise reduction of about 5 dB with an attendant reduction in detection distance. Furthermore, all these studies confirm the work of other investigators that the 1/3 octave band (center frequency=125 cps) is the most critical in reducing aural detection distance.

Connor, A. B.↗

High thermal-transport capacity heat pipes for space radiators

This paper presents the results of performance tests of several dual-slot heat pipe test articles. The dual-slot configuration has a very high thermal transport capability and has been identified as a very promising candidate for the radiator system for the NASA Space Station solar dynamic power modules. Two six-foot long aluminum heat pipes were built and tested with ammonia and acetone. A 20-ft long heat pipe was also built and tested with ammonia. The test results have been compared with performance predictions. A thermal transport capacity of 2000 W at an adverse tilt of 1 in. and a 1000 W capacity at an adverse tilt of 2 in. were achieved on the 20-ft long heat pipe. These values are in close agreement with the predicted performance limits.

Carlson, Albert W.↗

Overall contact conductance of a prototype Parallel Fin Thermal Interface

The Parallel Fin Thermal Interface has been developed and tested as an orbital replaceable interface. The interface consists of two identical plates with pairs of opposing parallel straight fins. Each pair of fins is sandwiched between two insert plates pressed against the fins with enough force for good heat transfer through the interface. Two prototype parallel fin interfaces were built (Model 140 and 380) with different fin and insert plate dimensions. Samples of the interfacing surfaces were found to have roughness values ranging from 22 to 35 microinches. Overall interface conductance (Hc) values of 46.7 to 74.2 Btu/hr sq ft-F were obtained for the 140 model in vacuum with an interface pressure from 18.8 to 37.5 psi, respectively. The Model 380 exhibited Hc values from 31.2 to 46.8 Btu/hr sq ft-F in vacuum, with respective interface pressures of 14.2 and 22.0 psi. Several correlations were found to agree with test data to within 20 percent.

Stobb, C. A.↗

Measurement of the thermal conductivity of composites using heat flow sensors

A thermal conductivity measuring apparatus that uses heat flow sensors to measure the heat flux through samples was constructed of inexpensive materials. This device was used to measure the thermal conductivity (k) of two composites used in the space program that consist of fibrous or granular components embedded in a resin matrix. The k-values that were determined ranged from 0.035 to 0.059 Btu/h sq ft-F/ft (-163 to 553 F) and 0.029 to 0.035 Btu/h-sq ft-F/ft (77 to 212 F). Thermal conductivity values of the composites conformed to the rule of mixture. The accuracy of the system was found to be comparable to the guarded hotplate and it requires neither a skilled operator nor extensive maintenance.

Penn, B. G.↗

Measurements of tropospheric nitric acid over the western United States and northeastern Pacific Ocean

HNO3 measurements obtained in the free troposphere (FT) and boundary layer (BL) over the western U.S. and the NE Pacific during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986 are reported. The CITE 2 HNO3 instruments and flight protocols are described, and the results are presented in tables and graphs. Over the ocean, the average HNO3 mixing ratios were found to be 108 parts per trillion by volume (pptv) in the FT and 62 pptv in the BL, suggesting removal of HNO3 from the BL by dry deposition. The corresponding values over land were 61 pptv for the FT and 767 pptv for the BL, and the horizontal distribution of BL HNO3 indicated an anthropogenic origin.

Lebel, P. J.↗