At least 73 records · Page 4

Improved high-gradient performance for medium-velocity superconducting half-wave resonators: Surface preparation and trapped flux mitigation

A development effort to improve the performance of superconducting radio-frequency half-wave resonators (SRF HWRs) is underway at the Facility for Rare Isotope Beams (FRIB), where 220 such resonators are in operation. Our goal was to achieve an intrinsic quality factor (𝑄 0 ) of ≥ 2 × 10 10 at an accelerating gradient (𝐸 acc ) of 12 MV/m. FRIB production resonators were prepared with buffered chemical polishing. First trials of electropolishing (EP) and post-EP low-temperature baking of FRIB HWRs allowed us to reach higher gradient (15 MV/m, limited by quench) with a higher quality factor at high gradient, but 𝑄 0 was still below our goal. Trapped magnetic flux during the Dewar test was found to be a source of 𝑄 0 reduction. Three strategies were used to reduce the trapped flux: (i) adding a local magnetic shield (LMGS) to supplement the “global” magnetic shield around the Dewar for reduction of the ambient magnetic field; (ii) performing a “uniform cooldown” (UC) to reduce the thermoelectric currents; and (iii) using a compensation coil to further reduce the ambient field with active field cancellation (AFC). The LMGS improved the 𝑄 0 , but not enough to reach our goal. With UC and AFC, we exceeded our goal, reaching 𝑄 0 = 2.8 ×10 10 at 𝐸 acc = 12 MV/m.

Cryogenics & vacuum technology↗

Acceleration of uranium beam to record power of 10.4 kW and observation of new isotopes at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) is a major nuclear physics facility for research with fast, stopped, and reaccelerated beams that was successfully commissioned in May 2022. A key capability of FRIB is the production of an acceleration of the uranium beam, but this capability requires the facility to work at the design limits of the lowest charge-to-mass ratio and the highest power density on the beam intercepting devices. This paper presents techniques for overcoming the significant challenges in accelerating the uranium beam, culminating in the demonstration of 10.4 kW on target, and the discovery of three new isotopes. The high-power uranium beam enabled us to produce and identify G 88 a , A 93 s , and S 96 e , within the first 24 h of operation. The successful uranium operation at FRIB sets a new record for accelerated uranium beam power above 10 kW and opens a new avenue of research with rare isotopes. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Advancements in High-Q development for novel medium-velocity 644 MHz 5-cell elliptical superconducting RF cavities for continuous-wave operation in heavy-ion linacs

The Facility for Rare Isotope Beams is a world-leading center for experimental nuclear physics research, and relies on a first-in-kind superconducting RF driver linac to supply 400 kW beams of a uniquely large range of particles, from protons through the heaviest uranium ions. The FRIB400 project proposes to double the end energy of the current superconducting FRIB linac for the heaviest uranium ions from 200 MeV per nucleon (MeV/u) to 400 MeV/u, which equates to approximately 1 GeV for protons. The increased rare isotope production from higher-energy drive beams would deliver new and exciting capabilities to FRIB users, which include extending the facility's reach along the neutron drip-line, greatly increasing the facility's rare isotope yield, and significantly improving the precision of parameter measurements for the nuclear matter equation of state, which is a particularly timely complement to the recent advent of multi-messenger astronomy, and the study of neutron star mergers. The unique set of design parameters defined by the 400 MeV/u (uranium) energy goal, the physical size, continuous-wave operation, and cryogenic capacity of the extant facilities at FRIB, requires development of a first-in-kind beta = v/c = 0.65, 644 MHz 5-cell elliptical superconducting RF (SRF) cavity, with field-leading efficiency, measured by the cavity's intrinsic quality factor, Q_0. The field of SRF has recently experienced a very active period of development, which demonstrated the potential to raise the Q_0 of 1.3 GHz cavities by factors of two to three or more. In addition to uncovering fascinating new properties of the fundamental physics of superconducting RF phenomena, these improvements suggest substantial improvements could be made over the minimum Q_0 of the proposed FRIB400 upgrade SRF cavities, if these new techniques can be adapted to the beta = 0.65, 644 MHz regime. This work presents the first validation of the the novel beta = 0.65, 644 MHz 5-cell elliptical superconducting RF cavity design, and the first results of both conventional and advanced RF surface preparation techniques. In particular, this work focuses on two recently-developed high-Q_0 recipes: N-doping, and furnace baking, setting the current world-record Q_0 for this type of resonant cavity at 3.8 x 10^10 at the FRIB400 operating gradient of 17.5 MV/m. We also find evidence that these results may be further improved upon, and make the case for further RF surface preparation recipe optimization. We then pair these high-power RF investigations with techniques borrowed from material science to try to better understand the ways in which specific properties of the niobium material, such as grain structure and superconducting flux pinning force, can be related to its superconducting RF performance. These experiments better elucidate the effects of high-temperature annealing on niobium samples, which suggest methods of further optimizing cavity flux expulsion and thus SRF performance.Read

McGee, Kellen E.↗

RF deflecting cavity for fast radioactive ion beams

Abstract The Facility for Rare Isotope Beams (FRIB) will be a new scientific user facility that produces rare-isotope beams for experiments from the fragmentation of heavy ions at energies of 100–200 MeV/u. During the projectile fragmentation, the rare isotope of interest is produced along with many contaminants that need to be removed before the beam reaches detectors. At FRIB, this is accomplished with a magnetic projectile fragment separator. However, to achieve higher beam purity, in particular for proton-rich rare isotopes, additional purification is necessary. RadiaBeam in collaboration with Michigan State University (MSU) has designed a 20.125 MHz radiofrequency (RF) fragment separator capable of producing a 4 MV kick with 18 cm aperture in order to remove contaminant isotopes based on their time of flight. In this paper, we will discuss the RF and engineering design considerations of this separator cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discovery of Nuclides Project

The Discovery of Nuclides project compiles detailed discovery information for all naturally occurring and artificially produced nuclides. The short abstracts for each nuclide include the authors, institution, country, year, method of discovery, and reference. The database contains over 3300 nuclides and is continuously updated as new nuclides are discovered. The work is performed at the Facility for Rare Isotope Beams (FRIB) and is supported by the U.S. Department of Energy, Office of Nuclear Physics under Grant No. DE-SC0016948 and Michigan State University. The FRIB Nuclear Data group is responsible for coordinating and updating the database.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid-phase isotope harvesting of 88 Zr from a radioactive ion beam facility

During routine operation of the Facility for Rare Isotope Beams (FRIB), radionuclides will accumulate in both the aqueous beam dump and along the beamline in the process of beam purification. These byproduct radionuclides, many of which are far from stability, can be collected and purified for use in other scientific applications in a process called isotope harvesting. In this work, the viability of 88 Zr harvesting from solid components was investigated at the National Superconducting Cyclotron Laboratory. A secondary 88 Zr beam was stopped in a series of collectors comprised of Al, Cu, W, and Au foils. Here, this work details irradiation of the collector foils and the subsequent radiochemical processing to isolate the deposited 88 Zr (and its daughter 88 Y) from them. Total average recovery from the Al, Cu, and Au collector foils was (91.3 ± 8.9) % for 88 Zr and (95.0 ± 5.8) % for 88 Y, respectively, which is over three times higher recovery than in a previous aqueous-phase harvesting experiment. The utility of solid-phase isotope harvesting to access elements such as Zr that readily hydrolyze in near-neutral pH aqueous conditions has been demonstrated for application to harvesting from solid components at FRIB.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

The FABLE silicon detector array for comprehensive studies of fusion and breakup dynamics

The Fusion and Breakup of Light Elements (FABLE) array, comprised of ΔE-E telescopes of neutron-transmutation doped (NTD) Double-Sided Silicon Strip Detectors (DSSDs), has been developed and commissioned for future experiments at the Facility for Rare Isotope Beams (FRIB). FABLE was designed to perform measurements of complete and incomplete fusion cross sections, to help address the interplay between breakup and clustering in outcomes of reactions with exotic nuclides. Here, the FABLE array has been commissioned in a comprehensive study at the ReAccelerator facility ReA6 of the Facility for Rare Isotope Beams (FRIB), investigating the dynamics in the weakly-bound proton rich 7 Be reaction on 208 Pb targets.

Breakup↗

The evidence of N = 16 shell closure and β -delayed neutron emission from 25 F

We measured the β -delayed neutron emission from 25 F for the first time at the Facility for Rare Isotope Beams (FRIB). Using combined neutron and γ -ray detector systems of the FRIB Decay Station Initiator (FDSi), we observed β -decay transitions populating neutron unbound states between 4.2 and 8 MeV in 25 Ne. The experimental results led to the revision of the β -decay half-life and β -delayed neutron-emission probability of 25 F. The β -decay strength distribution of 25 F extracted from the data agrees with the shell-model predictions using the USDB and SDPF-M effective interactions. This result indicates that the spherical neutron shell gap persists in 25 F and 25 Ne.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adsorption Studies of Dilute Krypton and Xenon from Nitrogen on SBMOF-1 and Activated Charcoal for Applications in Isotope Harvesting

Adsorptive partitioning of dilute krypton (Kr) and xenon (Xe) onto Stony Brook Metal–Organic Framework (SBMOF-1) and activated charcoal (AC) from carrier nitrogen was experimentally measured at temperatures ranging from 195 to 293 K. For this purpose, a closed-loop system for gas adsorption experiments was developed. From the Kr adsorption measurements, the adsorption equilibrium constant for Kr on SBMOF-1 was calculated, yielding a value for the enthalpy of adsorption of −19 ± 1 kJ·mol –1 . The partition coefficients were utilized to estimate the extraction rates of 76 Kr, 77 Kr, and 122 Xe isotopes during isotope harvesting at the Facility for Rare Isotope Beams (FRIB). We conclude that both materials showed promising results for the extraction of noble gases from FRIB effluents using temperature swing adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical potentials for the rare-isotope beam era

Abstract We review recent progress and motivate the need for further developments in nuclear optical potentials that are widely used in the theoretical analysis of nucleon elastic scattering and reaction cross sections. In regions of the nuclear chart away from stability, which represent a frontier in nuclear science over the coming decade and which will be probed at new rare-isotope beam facilities worldwide, there is a targeted need to quantify and reduce theoretical reaction model uncertainties, especially with respect to nuclear optical potentials. We first describe the primary physics motivations for an improved description of nuclear reactions involving short-lived isotopes, focusing on its benefits for fundamental science discoveries and applications to medicine, energy, and security. We then outline the various methods in use today to build optical potentials starting from phenomenological, microscopic, and ab initio methods, highlighting in particular, the strengths and weaknesses of each approach. We then discuss publicly-available tools and resources facilitating the propagation of recent progresses in the field to practitioners. Finally, we provide a set of open challenges and recommendations for the field to advance the fundamental science goals of nuclear reaction studies in the rare-isotope beam era. This paper is the outcome of the Facility for Rare Isotope Beams Theory Alliance (FRIB-TA) topical program ‘Optical Potentials in Nuclear Physics’ held in March 2022 at FRIB. Its content is non-exhaustive, was chosen by the participants and reflects their efforts related to optical potentials.

42 ENGINEERING↗

Paths to superheavy nuclei

This document summarizes the discussions and outcomes of the Facility for Rare Isotope Beams (FRIB) Theory Alliance topical program ‘The path to Superheavy Isotopes’ held in June 2024 at FRIB. Its content is non-exhaustive, reflecting topics chosen and discussed by the participants. The program aimed to assess the current status of theory in superheavy nuclei (SHN) research and identify necessary theoretical developments to guide experimental programs and determine fruitful production mechanisms. This report details the intersection of SHN research with other fields, provides an overview of production mechanisms and theoretical models, discusses future needs in theory and experiment, explores other potential avenues for SHN synthesis, and highlights the importance of building a strong theory community in this area.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Ground State Spin and Parity of 22 Al Disfavors Halo Formation

We report the decisive resolution of the ground state spin and parity of the proton–drip line nucleus 22 Al, a prime candidate for a proton halo. The resolution stems from the first 𝛽-delayed charged particle emission experiment in the gas stopping area at the Facility for Rare Isotope Beams (FRIB), leveraging high-intensity, low-energy beams extracted from the Advanced Cryogenic Gas Stopper (ACGS). The pristine beam quality from FRIB and the ACGS enabled a sensitive particle identification technique using thin silicon detectors, allowing for the suppression of the dominant proton background and the first observation of the weak 𝛽-delayed 𝛼 transition from the isobaric analog state in 22 Mg to the 18 Ne ground state. This observation uniquely fixes the 22 Al ground state as 4 + . The valence proton is confined by a dominant 𝑑-wave centrifugal barrier which, combined with the Coulomb repulsion, hinders the tunneling required for halo formation despite the exceptionally low proton separation energy of 22 Al.

20 ≤ A ≤ 38↗

Discovery of new isotopes in the fragmentation of 82 Se and insights into their production

The production cross sections of neutron-rich nuclei for elements just above 60 Ca were measured at the Facility for Rare Isotope Beams (FRIB). Four previously unobserved isotopes ( 63 Sc, 65,66 Ti, and 68 V) were produced, separated, and identified for the first time using the Advanced Rare Isotope Separator (ARIS). One event was found to be consistent with 61 Ca . The new isotopes were created through the interaction of an 82 Se beam with a carbon target at an energy of 228 MeV/𝑢 and a primary beam current of 1.07 p⁢µ⁢A. The event-by-event particle identification of the mass number (𝐴), atomic number (𝑍), and ionic charge state (𝑞) for the reaction products was achieved by combining measurements of energy loss, time of flight, magnetic rigidity, and total kinetic energy. This successful search for new isotopes, conducted at the beginning of FRIB's third year of operation, highlights the facility's discovery potential, which will continue to grow as the beam current increases. The production cross sections were analyzed in the context of the newly developed Δ⁢𝐵⁢𝐸 systematics that provides trends in neutron-rich regions and increased sensitivity to nuclear binding, an important nuclear structure observable. Furthermore, the new systematics addresses gaps in 𝑄 𝑔 -based methods commonly used to interpret the production cross sections of light neutron-rich elements, and provides an efficient empirical approach to describe cross-section trends across isotopic chains. Good agreement with the measured data was obtained when the Δ⁢𝐵⁢𝐸 systematics and abrasion-ablation calculations were performed using the Hartree-Fock-Bogoliubov (HFB-22) mass table.

59 ≤ A ≤ 89↗

Beta-Decay Half-Lives beyond 54 Ca: A Systematic Survey of Decay Properties Approaching the Neutron Dripline

In an experiment performed at the Facility for Rare Isotope Beams (FRIB) using the FRIB Decay Station initiator, 15 new half-lives of isotopes near 54 Ca were measured. A new method of extracting lifetimes from experimental data, taking into account the unknown 𝛽-delayed neutron emission branches of very neutron-rich nuclei, was developed to enable systematic uncertainty analysis. The experiment observed a dramatic change in the half-life systematics for the isotopes with neutron number 𝑁 = 34. Beyond 𝑁 = 34, the decline of nuclear lifetime is much slower, leading to longer than anticipated lifetimes for near-dripline nuclei. State-of-the-art shell-model calculations can explain the experimental results, revealing the imprint of shell effects and the need for modification of single-particle neutron states. In conclusion, the results from a newly developed quasiparticle random phase approximation model with potential for making global predictions were also tested against the experimental results and good agreement was found.

Physics - Nuclear physics and radiation physics↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗