Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY SYNCHRONIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PWM Switching Frequency Effects on Eddy Current Sensors for Magnetically Suspended Flywheel Systems

A flywheel magnetic bearing (MB) pulse width modulated power amplifier (PWM) configuration is selected to minimize noise generated by the PWMs in the flywheel position sensor system. Two types of noise are addressed: beat frequency noise caused by variations in PWM switching frequencies, and demodulation noise caused by demodulation of high order harmonics of the switching voltage into the MB control band. Beat frequency noise is eliminated by synchronizing the PWM switch frequencies, and demodulation noise is minimized by selection of a switching frequency which does not have harmonics at the carrier frequency of the sensor. The recommended MB PWM system has five synchronized PWMs switching at a non-integer harmonic of the sensor carrier.

Jansen, Ralph↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation: Preprint

This paper develops a non-phase-locked loop (PLL) grid-connected inverter that can improve the microgrid’s transients during transition operation. By emulating the operation of a synchronous machine, the inverter generates its own voltage and frequency during startup, synchronizes and connects to the grid, then operates in reactive power mode (grid-feeding) with self-generated voltage and frequency, and switches to voltage-frequency mode to establish system voltage and frequency (grid-forming) when the microgrid disconnects from the main grid, and vice versa. To enable fast synchronization, active synchronization control is adopted both during inverter startup and microgrid reconnection operation. The simulation results show that the developed non-PLL grid-connected inverter works effectively to synchronize the inverter and microgrid to the grid and avoids a phase jump during microgrid transition operation. Thus, the microgrid’s transients are significantly improved with the proposed control technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical Event Location Estimation Algorithm for Power Transmission System Based on Triangulation and Oscillation Intensity

Event location in power systems is quite essential information for system operators to enhance control-room situational awareness capability. Therefore, it is of great importance to develop an event location estimation algorithm for transmission systems with high accuracy. With the development of wide-area measurement system (WAMS) such as FNET/GridEye, and the synchrophasor measurement devices (SMDs) such as frequency disturbance recorders (FDRs), the synchronous measurement data including frequency, voltage amplitude and phase angle can be collected and used for event location estimation. First, the phase angle and rate of change of frequency (RoCoF) trajectories are respectively used for determining two sets of wave arrival time associated with each FDR. Then, a convolutional neural network (CNN) is utilized to determine the wave arrival order to select the more suitable set of wave arrival times for a given case and to perform corresponding modifications. Next, the oscillation intensity associated with each FDR is determined based on phase angle trajectories in the center of inertia (COI) coordinate system. Finally, the multiple criteria for event location estimation are represented. In conclusion, case studies and comparisons between the proposed and previous algorithms using actual and confirmed cases in U.S. power systems are performed to demonstrate the effectiveness and improvement of the proposed algorithm in practical applications.

frequency disturbance recorder (FDR)↗

Interleaver design for trellis-coded differential 8-PSK modulation with non-coherent detection

The effect of finite interleaver size on bit error rate (BER) performance of coded 8-DPSK is determined by means of computer simulations. The losses evaluated in this way include the SNR degradation due to the timing and frequency errors of the symbol synchronizer and the automatic frequency control (AFC) of the receiver. BER measurements are presented using a conventional 2/3 rate convolutional 8-state trellis-code for typical Rayleigh and Rician fading channels. It is shown that for a Rician channel with a Rician parameter of 7 dB, a Doppler spread of 100 Hz and a data rate of 2400 bps, an interleaver with size 16 x 16 symbols performs nearly as well as a very large interleaver. It is also shown that for very fast Rayleigh channels, the BER-curves flatten out at large SNR.

Edbauer, Franz↗

Open loop digital frequency multiplier

An open loop digital frequency multiplier is described which has a multiplied output synchronized to low frequency clock pulse. The system includes a multistage digital counter which provides a pulse output as a function of an integer divisor. The integer divisor and the timing or counting cycle of the counter are interrelated to the frequency of a clock input. The counting cycle is controlled by a one shot multivibrator which, in turn, is driven by a reference frequency input.

Moore, R. C.↗

Pseudonoise (PN) synchronization of data system with derivation of clock frequency from received signal for clocking receiver PN generator

A digital communicating system for automatically synchronizing signals for data detection is described. The systems consists of biphase modulating a subcarrier frequency by the binary data and transmitting a carrier phase modulated by this signal to a receiver, where coherent phase detection is employed to recover the subcarrier. Data detection is achieved by providing, in the receiver, a demodulated reference which is in synchronism with the unmodulated subcarrier in transmitting system. The output of the detector is passed through a matched filter where the signal is integrated over a bit period. As a result, random noise components are averaged out, so that the probability of detecting the correct data transmitted is maximized.

Couvillon, L. A., Jr.↗

Frequency Shaping Control for Weakly-Coupled Grid-Forming IBRs

Here, we consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DynaShape: Dynamic Shaping of Grid Response with Inverters

We consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.

frequency-shaping control↗

Stability and control of power systems with high penetrations of inverter-based resources: An accessible review of current knowledge and open questions

As power system renewable energy penetrations increase, the ways in which key renewable technologies such as wind and solar photovoltaics (PV) differ from thermal generators become more apparent. Many studies have examined the variability and uncertainty of such generators and described how generation and load can be balanced for a wide variety of annual energy penetrations, at timescales from seconds to years. Another important characteristic of these resources is asynchronicity, the result of using inverters to interface the prime energy source with the power system as opposed to synchronous generators. Unlike synchronous generators, whose frequency of alternating current (AC) injection is physically coupled to the rotation of the machine itself, inverter based asynchronous generators do not share the same physical coupling with the generated frequency. These subtle differences impact the operations of power systems developed around the characteristics of synchronous generators. In this paper we review current knowledge and open research questions concerning the interplay between asynchronous inverter-based resources (IBRs) and cycle- to second-scale power system dynamics, with a focus on how stability and control may be impacted or need to be achieved differently when there are high instantaneous penetrations of IBRs across an interconnection. This work does not seek to provide a comprehensive review of the latest developments, but is instead intended to be accessible to any reader with an engineering background and an interest in power systems and renewable energy. As such, the paper includes basic material on power electronics, control schemes for IBRs, and power system stability; and uses this background material to describe potential impacts of IBRs on power system stability, operational challenges associated with large amounts of distributed IBR generation, and modern power system simulation trends driven by IBR characteristics.

14 SOLAR ENERGY↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved frequency divider employs transistor avalanche effect

New frequency divider circuit can be synchronized over a wider input control frequency range, has greater phase stability, and is less sensitive to temperature changes than conventional synchronized oscillators. The new circuit uses the avalanche breakdown mode of operation of transistors.

Johns, C. E.↗

Stability and noise spectra of relative Loran-C frequency comparisons

Relative comparisons of Loran-C frequency transmissions between the master station of Catanzaro (Simeri Crichi) and the X, Z slave stations of Estartit (Spain) and Lampedusa (Italy) are carrying out by the GG LORSTA monitor station of the Mediterranean Sea Loran-C chain. These comparisons are able to emphasize the relative and, under certain conditions, the absolute rate of the emitting standard frequencies of the slave stations and some relevant statistical properties of the Loran-C Method for frequency transmission and time synchronization. The stability of each Loran-C frequency standard transmission is subject to perturbations, more or less known, due to the propagation medium and other causes. Following the Allan (1966) method for data processing, the performance of the relative rate of frequency of the transmissions of the X, Z slave stations are described calculating the standard deviation of a set of N frequency measurements from its mean averaged during sampling times. This standard deviation is designated as the measure of the stability of the Loran-C frequency transmission.

Proverbio, E.↗

Synchronization of nonsolitonic Kerr combs

Synchronization is a ubiquitous phenomenon in nature that manifests as the spectral or temporal locking of coupled nonlinear oscillators. In the field of photonics, synchronization has been implemented in various laser and oscillator systems, enabling applications including coherent beam combining and high-precision pump-probe measurements. Recent experiments have also shown time-domain synchronization of Kerr frequency combs via coupling of two separate oscillators operating in the dissipative soliton [i.e., anomalous group velocity dispersion (GVD)] regime. Here, we demonstrate all-optical synchronization of Kerr combs in the nonsolitonic, normal GVD regime in which phase-locked combs with high pump-to-comb conversion efficiencies and relatively flat spectral profiles are generated. Our results reveal the universality of Kerr comb synchronization and extend its scope beyond the soliton regime, opening a promising path toward coherently combined normal GVD Kerr combs with spectrally flat profiles and high comb-line powers in an efficient microresonator platform.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The dominant mode of standing Alfven waves at synchronous orbit

Low-frequency oscillations of the earth's magnetic field recorded by the UCLA magnetometer on board ATS-1, have been examined for the six-month interval, January-June, 1968. The initial interpretation, that these oscillations represent the second harmonic of a standing Alfven wave, has been re-examined, and it is concluded that this hypothesis must be withdrawn. Using evidence from OGO-5 and ATS-5, as well as the data from ATS-1, it is argued that the dominant mode at the synchronous orbit must be the fundamental rather than the second harmonic. From 14 instances when the oscillations of distinctly different periods occurred during the same time interval at ATS-1 it is concluded that higher harmonics can exist. The period ratio in 7 of the 14 cases corresponds to the simultaneous occurrence of the second harmonic with the fundamental, and 4 other cases could be identified as the simultaneous occurrence of the fourth harmonic with the fundamental.

Cummings, W. D.↗

Efficient Distribution of Frequency-Standard Signals

Low power system distributes precise frequency standard signal to network of remote stations. Reference frequency at phase angle modulates transmitter at master transmitter/receiver circuit and recovers at remote circuit. Two circuits continuously transmit on microwave or optical signals 100 MHz apart to effect synchronization of reference frequency and phase.

Meyer, R. F.↗