Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design of voice coil motor dynamic focusing unit for a laser scanner

Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden–Fletcher–Goldfarb–Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced focus steering abilities of multi-element therapeutic arrays operating in nonlinear regimes

Steering abilities of a typical HIFU therapeutic array operated in linear and nonlinear regimes were compared using numerical simulation with the 3D Westervelt equation. The array included 256 elements of 1.2 MHz frequency and 6.6 mm diameter distributed in a quasi-random pattern over a spherical shell with a 130 mm aperture and a focal length of 120 mm. In the case of linear focusing, thermal effects are proportional to the intensity level and the criterion for safe array operation is that the intensity in the grating lobes should be less than 10% of the intensity in the main focus. In the case of nonlinear focusing, the heating effect is no longer proportional to intensity; therefore the heat deposition rate was chosen as the relevant metric, using the same 10% threshold for the secondary lobe in comparison with the focal maximum. When steering the focus, the same linearly predicted intensity level at the main focus was maintained by increasing the array power. Numerical simulations of the acoustic field were performed for nonlinear propagation both in water and in tissue. It was shown that for shock-forming conditions in the main focus, the steering range of safe electronic focusing is larger than that for linear propagation conditions. Nonlinear sonication regimes therefore can be used to enlarge tissue volumes that can be sonicated using electronic steering of the focus of HIFU arrays.

42 ENGINEERING↗

Focus history of the Hubble Space Telescope: Launch to May 1993

Since the launch of the Hubble Space Telescope (HST) the secondary mirror of the telescope has been moved several times in order to collimate the telescope and also to define a position of best focus. In addition to these moves the focus position changes over time because of water desorption by the graphite epoxy in the metering truss. The authors report here the focus history of the telescope based on a knowledge of the mirror moves made and an analysis of desorption monitoring data obtained by the Faint Object Camera (FOC) in the F/96 mode and of the routine calibration data obtained by the Wide Field and Planetary Cameras. Focus values are extracted using two different methods. In the first method the distance between the center of the point spread function (PSF) and the shadows of the pads supporting the HST primary mirror are related to the focus error. In the second method an analytical formula for the PSF with variable aberration coefficients is fitted to the data. Focus positions derived from the two methods show good agreement. The data show that a desorption of about 83 microns has taken place since Aug. 16, 1990. The desorption has clearly not leveled off as expected from the trend of the earlier data. Long term variations of the secondary mirror position of approximately 3-15 microns from the 'best' focus position have been observed. Variations of the order of 2-5 microns over an orbital period have also been noted. Focus changes resulting from secondary mirror movements greater than approximately 5 microns changes the point spread function significantly and makes deconvolution and quantitative measurements difficult.

Hasan, H.↗

Enhanced relativistic self-focusing of Hermite-cosh-Gaussian laser beam in plasma under density transition

Enhanced and early relativistic self-focusing of Hermite-cosh-Gaussian (HChG) beam in the plasmas under density transition has been investigated theoretically using Wentzel-Kramers-Brillouin and paraxial ray approximation for mode indices m=0, 1, and 2. The variation of beam width parameter with normalized propagation distance for m=0, 1, and 2 is reported, and it is observed that strong self-focusing occurs as the HChG beam propagates deeper inside the nonlinear medium as spot size shrinks due to highly dense plasmas and the results are presented graphically. A comparative study between self-focusing of HChG beam in the presence and absence of plasmas density transition is reported. The dependency of beam width parameter on the normalized propagation distance for different values of decentered parameter “b” has also been presented graphically. For m=0 and 1, strong self-focusing is reported for b=1.8, and for m=2 and b=1.8, beam gets diffracted. The results obtained indicate the dependency of the self-focusing of the HChG beam on the selected values of decentered parameter. Moreover, proper selection of decentered parameter results strong self-focusing of HChG beam. Stronger self-focusing of laser beam is observed due to the presence of plasma density transition which might be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An estimate of the error caused by the elongation of the wavelength in a focused beam in free-space electromagnetic parameters measurement

A pair of spot-focusing horn lens antenna is the key component in a free-space measurement system. The electromagnetic constitutive parameters of a planar sample are determined using transmitted and reflected electromagnetic beams. These parameters are obtained from the measured scattering parameters by the microwave network analyzer, thickness of the sample, and wavelength of a focused beam on the sample. Free-space techniques introduced by most papers consider the focused wavelength as the free-space wavelength. But in fact, the incident wave projected by a lens into the sample approximates a Gaussian beam, thus, there has an elongation of the wavelength in the focused beam and this elongation should be taken into consideration in dielectric and magnetic measurement. In this paper, elongation of the wavelength has been analyzed and measured. Measurement results show that the focused wavelength in the vicinity of the focus has an elongation of 1%–5% relative to the free-space wavelength. Elongation's influence on the measurement result of the permittivity and permeability has been investigated. Numerical analyses show that the elongation of the focused wavelength can cause the increase of the measured value of the permeability relative to traditionally measured value, but for the permittivity, it is affected by several parameters and may increase or decrease relative to traditionally measured value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional spatiotemporal focusing of femtosecond pulses and its applications in microscopy

We demonstrate and theoretically analyze the two-dimensional spatiotemporal focusing of femtosecond pulses by utilizing a two-dimensional spectral disperser. Compared with spatiotemporal focusing with a diffraction grating, it can achieve widefield illumination with better sectioning ability for a multiphoton excitation process. By utilizing paraxial approximation, our analytical method improves the axial confinement ability and identifies that the free spectra range (FSR) of the two-dimensional spectral disperser affects the out-of-focus multiphoton excitation intensity due to the temporal self-imaging effect. Based on our numerical simulation, a FSR of 50 GHz is necessary to reduce the out-of-focus two-photon excitation by 2 orders of magnitude compared with that in a grating-based spatiotemporal focusing scheme for a 90-fs excitation laser pulse. We build a two-dimensional spatiotemporal focusing microscope using a virtually imaged phased array and achieve an axial resolution of 1.3 μm, which outperforms the resolution of conventional spatiotemporal focusing using a grating by a factor of 1.7, and demonstrate better image contrast inside a tissue-like phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wave-optical assessment of alignment tolerances in nano-focusing with ellipsoidal mirror

High-precision ellipsoidal mirrors, which can efficiently focus X-rays to the nanometer dimension with a mirror, have not been realized because of the difficulties in the fabrication process. The purpose of our study was to develop nano-focusing ellipsoidal mirrors in the hard X-ray region. We developed a wave-optical focusing simulator for investigating alignment tolerances in nano-focusing with a designed ellipsoidal mirror, which produce a diffraction-limited focus size of 30 × 35 nm{sup 2} in full width at half maximum at an X-ray energy of 7 keV. The simulator can calculate focusing intensity distributions around the focal point under conditions of misalignment. The wave-optical simulator enabled the calculation of interference intensity distributions, which cannot be predicted by the conventional ray-trace method. The alignment conditions with a focal length error of ≲ ±10 µm, incident angle error of ≲ ±0.5 µrad, and in-plane rotation angle error of ≲ ±0.25 µrad must be satisfied for nano-focusing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flying focus: Spatial and temporal control of intensity for laser-based applications

An advanced focusing scheme, called a "flying focus," uses a chromatic focusing system combined with a broadband laser pulse with its colors arranged in time to propagate a high intensity focus over a distance that can be much greater than its Rayleigh length, while decoupling the speed at which the peak intensity propagates from its group velocity. The flying focus generates a short effective pulse duration with a small diameter focal spot that co- or counter-propagates along the optical axis at any velocity. Experiments validating the concept measured subluminal (–0.09c) to superluminal (39c) focal spot velocities with a nearly constant peak intensity over 4.5 mm. Experiments that increased the peak intensity above the ionization threshold for gas demonstrated ionization waves propagating at the velocity of the flying focus. Here these ionization waves of any velocity overcome several laser-plasma propagation issues, including ionization-induced refraction. The flying focus presents opportunities to overcome current fundamental limitations in laser-plasma amplifilers, laser wakefield accelerators, photon accelerators, and high-order frequency conversion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intense gamma-ray source based on focused electron beams from a laser wakefield accelerator

Laser wakefield accelerators generate ultrashort electron bunches with the capability to produce γ-rays. Here, we produce focused laser wakefield acceleration electron beams using three quadrupole magnets. Electron beams are then focused into a 3 mm lead converter to generate intense, focused bremsstrahlung γ beams. Experimental results demonstrate the generation and propagation of focused γ beams to a best focus spot size of 2.3 ± 0.1 × 2.7 ± 0.2 mm 2 using a copper stack calorimeter. Monte Carlo simulations conducted using GEANT4 are in good agreement with experimental results and enable detailed examination of γ-ray generation. Simulations indicate that the focused γ beams contained 2.6 × 10 9 photons in the range of 100 keV to 33 MeV with an average energy of 6.4 MeV. A γ-ray intensity of 7 × 10 10 W/cm 2 was estimated from simulations. In conclusion, the generation of focused bremsstrahlung γ-ray sources can have important applications in medical imaging applications and laboratory astrophysics experiments.

43 PARTICLE ACCELERATORS↗

Radiation by a laser-driven flying-focus electron wave packet

An exact solution of the Dirac equation in the presence of an arbitrary electromagnetic plane wave is found, which corresponds to a focused electron wave packet, with the focus of the wave packet moving at the speed of light in the opposite direction of the average momentum of the electron wave packet (unless the plane wave is so intense to reflect the electron). The photon spectrum emitted by such an electron wave packet in the presence of a linearly polarized plane wave is studied both analytically and numerically. The spectrum is also compared with the one emitted by a single-momentum, plane-wave electron in the case of the electron being initially counterpropagating (on average for the flying-focus case) with the plane wave and within the locally constant field approximation. It is found that if the electron flying-focus wave packet is focused beyond a Compton wavelength, the angular distribution of the emitted radiation along the magnetic field of the electromagnetic plane wave is broader than for an electron with definite momentum. Corresponding the maximum value of the photon yield on the transverse plane is smaller in the flying-focus electron case. This could represent an experimental signature of a laser-driven flying-focus electron wave packet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-304-02: Magnetically Focused Proton Irradiation of Small Field Targets

Purpose: To investigate the use of magnetic focusing for small field proton irradiations. It is hypothesized that magnetic focusing will provide significant dose distribution benefits over standard collimated beams for fields less than 10 mm diameter. Methods: Magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into hollow cylinders were designed and manufactured. Two focusing magnets were placed on a positioning track on our Gantry 1 treatment table. Proton beams with energies of 127 and 157 MeV, 15 and 30 mm modulation, and 8 mm initial diameters were delivered to a water tank using single-stage scattering. Depth dose distributions were measured using a PTW PR60020 diode detector and transverse profiles were measured with Gafchromic EBT3 film. Monte Carlo simulations were also performed - both for comparison with experimental data and to further explore the potential of magnetic focusing in silica. For example, beam spot areas (based on the 90% dose contour) were matched at Bragg depth between simulated 100 MeV collimated beams and simulated beams focused by two 400 T/m gradient magnets. Results: Preliminary experimental results show 23% higher peak to entrance dose ratios and flatter spread out Bragg peak plateaus for 8 mm focused beams compared with uncollimated beams. Monte Carlo simulations showed 21% larger peak to entrance ratios and a ∼9 fold more efficient dose to target delivery compared to spot-sized matched collimated beams. Our latest results will be presented. Conclusion: Our results suggest that rare earth focusing magnet assemblies could reduce skin dose and beam number while delivering dose to nominally spherical radiosurgery targets over a much shorter time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however expanded treatment sites can be also envisaged.

60 APPLIED LIFE SCIENCES↗

Changes in the dark focus of accommodation associated with simulator sickness

The relationship between the dark focus of accommodation and simulator sickness, a form of motion sickness, was examined in three experiments. In Experiment 1, dark focus was measured in 18 college students in a laboratory setting before and after they viewed a projected motion scene depicting low altitude helicopter flight. In Experiments 2 and 3, dark focus was measured in pilots (N = 16 and 23, respectively) before and after they 'flew' in moving-base helicopter flight simulators with optical infinity CRT visual systems. The results showed that individuals who experienced simulator sickness had either an inward (myopic) change in dark focus (Experiments 1 and 3) or attenuated outward shifts in dark focus (Experiment 2) relative to participants who did not get sick. These results are consonant with the hypothesis that parasympathetic activity, which may be associated with simulator sickness, should result in changes in dark focus that are in a myopic direction. Night vision goggles, virtual environments, extended periods in microgravity, and heads-up displays all produce related visual symptomatology. Changes in dark focus may occur in these conditions, as well, and should be measured.

Fowlkes, Jennifer E.↗

Reducing video frame rate increases remote optimal focus time

Twelve observers made best optical focus adjustments to a microscope whose high-resolution pattern was video monitored and displayed first on a National Television System Committee (NTSC) analog color monitor and second on a digitally compressed computer monitor screen at frame rates ranging (in six steps) from 1.5 to 30 frames per second (fps). This was done to determine whether reducing the frame rate affects the image focus. Reducing frame rate has been shown to be an effective and acceptable means of reducing transmission bandwidth of dynamic video imagery sent from Space Station Freedom (SSF) to ground scientists. Three responses were recorded per trial: time to complete the focus adjustment, number of changes of focus direction, and subjective rating of final image quality. It was found that: the average time to complete the focus setting increases from 4.5 sec at 30 fps to 7.9 sec at 1.5 fps (statistical probability = 1.2 x 10(exp -7)); there is no significant difference in the number of changes in the direction of focus adjustment across these frame rates; and there is no significant change in subjectively determined final image quality across these frame rates. These data can be used to help pre-plan future remote optical-focus operations on SSF.

Haines, Richard F.↗

Deep-Focusing Time-Distance Helioseismology

Much progress has been made by measuring the travel times of solar acoustic waves from a central surface location to points at equal arc distance away. Depth information is obtained from the range of arc distances examined, with the larger distances revealing the deeper layers. This method we will call surface-focusing, as the common point, or focus, is at the surface. To obtain a clearer picture of the subsurface region, it would, no doubt, be better to focus on points below the surface. Our first attempt to do this used the ray theory to pick surface location pairs that would focus on a particular subsurface point. This is not the ideal procedure, as Born approximation kernels suggest that this focus should have zero sensitivity to sound speed inhomogeneities. However, the sensitivity is concentrated below the surface in a much better way than the old surface-focusing method, and so we expect the deep-focusing method to be more sensitive. A large sunspot group was studied by both methods. Inversions based on both methods will be compared.

Duvall, T. L., Jr.↗

A Scanning Hartmann Focus Test for the EUVI Telescopes aboard STEREO

The Solar TErrestrial RElations Observatory (STEREO), the third mission in NASA's Solar Terrestrial Probes program, was launched in 2006 on a two year mission to study solar phenomena. STEREO consists of two nearly identical satellites, each carrying an Extreme Ultraviolet Imager (EUVI) telescope as part of the Sun Earth Connection Coronal and Heliospheric Investigation instrument suite. EUVI is a normal incidence, 98mm diameter, Ritchey-Chretien telescope designed to obtain wide field of view images of the Sun at short wavelengths (17.1-30.4nm) using a CCD detector. The telescope entrance aperture is divided into four quadrants by a mask near the secondary mirror spider veins. A mechanism that rotates another mask allows only one of these sub-apertures to accept light over an exposure. The EUVI contains no focus mechanism. Mechanical models predict a difference in telescope focus between ambient integration conditions and on-orbit operation. We describe an independent check of the ambient, ultraviolet, absolute focus setting of the EUVI telescopes after they were integrated with their respective spacecraft. A scanning Hartmann-like test design resulted from constraints implied by the EUVI aperture select mechanism. This inexpensive test was simultaneously coordinated with other NASA integration and test activities in a high-vibration, clean room environment. The total focus test error was required to be better than +/-0.05 mm. We describe the alignment and test procedure, sources of statistical and systematic error, and then the focus determination results using various algorithms. The results are consistent with other tests of focus alignment and indicate that the EUVI telescopes meet the ambient focus offset requirements. STEREO is functioning well on-orbit and the EUVI telescopes meet their on-orbit image quality requirements.

Ohl, Ray↗

Microwave and Millimeter Wave Imaging Using Synthetic Aperture Focusing and Holographical Techniques

Microwave and millimeter wave nondestructive testing and evaluation (NDT&E) methods have shown great potential for determining material composition in composite structures, determining material thickness or debond thickness between two layers, and determining the location and size of flaws, defects, and anomalies. The same testing methods have also shown great potential to produce relatively high-resolution images of voids inside Spray On Foam Insulation (SOFI) test panels using real focused methods employing lens antennas. An alternative to real focusing methods are synthetic focusing methods. The essence of synthetic focusing is to match the phase of the scattered signal to measured points spaced regularly on a plane. Many variations of synthetic focusing methods have already been developed for radars, ultrasonic testing applications, and microwave concealed weapon detection. Two synthetic focusing methods were investigated; namely, a) frequency-domain synthetic aperture focusing technique (FDSAFT), and b) wide-band microwave holography. These methods were applied towards materials whose defects were of low dielectric contrast like air void in SOFI. It is important to note that this investigation used relatively low frequencies from 8.2 GHz to 26.5 GHz that are not conducive for direct imaging of the SOFI. The ultimate goal of this work has been to demonstrate the capability of these methods before they are applied to much higher frequencies such as the millimeter wave frequency spectrum (e.g., 30-300 GHz).

Case, Joseph Tobias↗

Interaction of the high energy deuterons with the graphite target in the plasma focus devices based on Lee model

Numerical experiments are systematically carried out using the Lee model code extended to compute the ion beams on various plasma focus devices operated with Deuterium gas. The deuteron beam properties of the plasma focus are studied for low and high energy plasma focus device. The energy spectral distribution for deuteron ions ejected from the pinch plasma is calculated and the ion numbers with energy around 1 MeV is then determined. The deuteron–graphite target interaction is studied for different conditions. The yield of the reaction {sup 12}C(d,n){sup 13}N and the induced radioactivity for one and multi shots plasma focus devices in the graphite solid target is investigated. Our results present the optimized high energy repetitive plasma focus devices as an alternative to accelerators for the production of {sup 13}N short lived radioisotopes. However, technical challenges await solutions on two fronts: (a) operation of plasma focus machines at high rep rates for a sufficient period of time (b) design of durable targets that can take the thermal load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Acoustic focusing of microplastics in microfabricated and steel tube devices: An experimental study on the effects from particle size and medium density

The contamination of aquatic systems with microplastics is becoming a severe threat to living organisms. Microplastics found in the environment consist of a wide range of particle sizes thus give rise to several challenges to current purification methods. Acoustic focusing has been utilized as a particle concentrating method in biological and non-biological applications. In this study, we investigate the feasibility of using acoustic focusing technology to isolate microplastics in aqueous samples and find that a two-stage mechanism is essential to concentrate microplastics of wide size ranges of the same material. We demonstrate for the first time experimentally that when the particle size is comparable to the resonance wavelength, they deviate from typical pressure nodal focusing and show pressure antinodal focusing. Further, we have expanded microplastics isolation beyond microfluidic systems and demonstrate their extraction capabilities relatively at higher flow rates using microplastics of polystyrene, polyethylene, and polymethyl methacrylate ranging from 6 µm to 300 µm diameter and in devices fabricated with cylindrical steel tubes. We could extract 70% of microplastics smaller than 180 µm and 82% of microplastics greater than 180 µm in diameter from an aqueous sample at a flow rate of 12 mL/min. In conclusion, we demonstrate that small microplastics focus on acoustic pressure nodes regardless of the medium density. However, focusing of large microplastics of the same material depends on the medium density.

42 ENGINEERING↗