Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUE GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Catalytic Removal of Oxygen Impurities from Pressurized Oxy-Combustion Flue Gas for the Production of High-Purity Carbon Dioxide

Flue gas purification is important for pressurized oxy-combustion systems to produce pure carbon dioxide (CO 2 ) streams ready for storage or utilization. A catalytic approach to removing oxygen (O 2 ) impurities from pressurized oxy-combustion flue gas via reduction with methane (CH 4 ) was investigated in this work. Two types of catalysts were studied: palladium (Pd)-based catalysts supported on titania (TiO 2 ) prepared by incipient wetness impregnation and cobalt–manganese (CoMn) composite catalysts prepared by coprecipitation. The performance of the catalysts was evaluated in a high-pressure–high-temperature, fixed-bed reactor at a pressure of 15 bar and a gas hourly space velocity of 30 000 h –1 (standard conditions), with a simulated feeding gas composed of 3 vol % O 2 , 1.5 vol % CH 4 , and CO 2 as the balance gas. Among the Pd catalysts, 5% Pd/TiO 2 achieved the maximum 86% O 2 removal at ≥350 °C. The CoMn oxide catalysts displayed comparable or better activities for O 2 reduction compared with the Pd catalysts. Among them, the Co 40 Mn 1 catalyst exhibited the best performance, able to reduce 99.9% of O 2 impurities at ~370 °C with negligible carbon monoxide (CO) formation (<10 ppmv). Both trivalent and divalent Co and Mn were detected on the catalyst surface, and the superior activity of Co 40 Mn 1 might be associated with the resultant disordered structure. Furthermore, the activity of the catalyst was not affected by the presence of a trace amount of nitric oxide (NO) gas contaminant. Results of this study provide the basis for scale-up studies in both the synthesis and performance of non-noble metal catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of BOC'S Lotox Process for the Oxidation of Elemental Mercury in Flue Gas from a Coal-Fired Boiler

Linde's Low Temperature Oxidation (LoTOx{trademark}) process has been demonstrated successfully to remove more than 90% of the NOx emitted from coal-fired boilers. Preliminary findings have shown that the LoTOx{trademark} process can be as effective for mercury emissions control as well. In the LoTOx{trademark} system, ozone is injected into a reaction duct, where NO and NO{sub 2} in the flue gas are selectively oxidized at relatively low temperatures and converted to higher nitrogen oxides, which are highly water soluble. Elemental mercury in the flue gas also reacts with ozone to form oxidized mercury, which unlike elemental mercury is water-soluble. Nitrogen oxides and oxidized mercury in the reaction duct and residual ozone, if any, are effectively removed in a wet scrubber. Thus, LoTOx{trademark} appears to be a viable technology for multi-pollutant emission control. To prove the feasibility of mercury oxidation with ozone in support of marketing LoTOx{trademark} for multi-pollutant emission control, Linde has performed a series of bench-scale tests with simulated flue gas streams. However, in order to enable Linde to evaluate the performance of the process with a flue gas stream that is more representative of a coal-fired boiler; one of Linde's bench-scale LoTOx{trademark} units was installed at WRI's combustion test facility (CTF), where a slipstream of flue gas from the CTF was treated. The degree of mercury and NOx oxidation taking place in the LoTOx{trademark} unit was quantified as a function of ozone injection rates, reactor temperatures, residence time, and ranks of coals. The overall conclusions from these tests are: (1) over 80% reduction in elemental mercury and over 90% reduction of NOx can be achieved with an O{sub 3}/NO{sub X} molar ratio of less than two, (2) in most of the cases, a lower reactor temperature is preferred over a higher temperature due to ozone dissociation, however, the combination of both low residence time and high temperature proved to be effective in the oxidation of both NOx and elemental mercury, and (3) higher residence time, lower temperature, and higher molar ratio of O{sub 3}/NOx contributed to the highest elemental mercury and NOx reductions.

01 COAL, LIGNITE, AND PEAT↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Evaluation of Concentrated Piperazine for CO 2 Capture from Coal-Fired Flue Gas (Final Report, REV0)

Concentrated piperazine (PZ) is a novel solvent being developed by the University of Texas at Austin (UT) for CO 2 capture from coal-fired power plants. The high thermal stability of PZ permits solvent regeneration at higher temperature (150 °C) and pressure, reducing compression capital and operating costs. The purpose of Cooperative Agreement DE-FE0005654, Evaluation of Concentrated Piperazine for CO 2 Capture from Coal-Fired Flue Gas , was to gain operational experience using PZ solvent to absorb CO 2 and explore novel, high-temperature processes for solvent regeneration. The pilot-scale test campaigns funded under this project have resulted in the continual improvement in the heat duty of the regeneration systems and solvent and equipment optimization. This document summarizes the results from the Phase 1 (2011, 2013 and 2015) and Phase 2 (2018) test campaigns. In Phase 1, the campaign was conducted on synthetic flue gas at the University of Texas’ Separations Research Program (SRP) facility to investigate CO 2 capture with 5 and 8 molal (5$m$ and 8$m$) PZ and two-stage flash (2SF) and advanced flash stripper (AFS) regeneration designs. Phase 1 testing also investigated techniques for measuring amine aerosol that can be generated during operation, and the effect of absorber operating conditions and sulfur containing compounds in the flue gas on aerosol generation. This testing showed that the AFS represents an optimized amine regeneration system with superior energy performance and simple operability over the 2SF or a simple stripper (SS), that 5$m$ PZ provides an economic and operability advantage over 8$m$ PZ, and that phase doppler interferometry (PDI) can provide useful particle size information on amine aerosol. In Phase 2, the campaign was conducted on coal-fired flue gas at the National Carbon Capture Center (NCCC) to investigate CO 2 capture with 5$m$ PZ and the AFS. The PZ solvent was also used with an existing SS at the NCCC to provide comparison with the AFS performance. Additionally, the campaign investigated the effect of flue gas SO 3 on amine aerosol from the CO 2 absorber. The NCCC pilot plant testing demonstrated the robustness of the PZ solvent and the high energy performance of the AFS provided significant improvements in energy performance over the conventional SS for PZ and other solvents, and approached the DOE’s economic targets for second generation carbon capture technologies. Extended testing allowed the project team to demonstrate reliable long-term operation of this novel regeneration technology and solvent combination. EPRI, Luminant, B&W, LG&E, Chevron, Southern Company, and UT are project co-funders. UT and Trimeric were project team members. URS Group was the prime contractor.

20 FOSSIL-FUELED POWER PLANTS↗

Simultaneous removal of SO{sub 2}, NOx, and Hg from coal flue gas using a NaClO{sub 2}-enhanced wet scrubber

A bench-scale study was conducted on the simultaneous removal Of SO{sub 2}, NOx, and mercury (both Hg{sup 0} and Hg{sup 2+}) from a simulated coal flue gas using a wet calcium carbonate scrubber. The multipollutant capacity of the scrubber was enhanced with the addition of the oxidizing salt, sodium chlorite. The results showed a maximum scrubbing of 100% for SO{sub 2} and Hg species and near complete NO oxidation with about 60% scrubbing of the resulting NOx species. The chlorite additive was less effective as an oxidant in the absence of SO{sub 2} and NO in the flue gas. Oxidation of NO and mercury were only about 50% and 80%, respectively, in the case of no SO{sub 2} in the simulated flue gas. The mercury oxidation was similarly affected by the absence of NO in the flue gas.

01 COAL, LIGNITE, AND PEAT↗

Carbon Mineralization by Aqueous Precipitation for Beneficial Use of CO2 from Flue Gas

The objective of this project is to demonstrate an innovative process to mineralize CO2 from flue gas directly to reactive carbonates and maximize the value and versatility of its beneficial use products. The program scope includes the design, construction, and testing of a CO2 Conversion to Material Products (CCMP) Pilot Demonstration Plant utilizing CO2 from the flue gas of a power production facility in Moss Landing, CA as well as flue gas from coal combustion. This topical report covers Phase 2b, which is the construction phase of pilot demonstration subsystems that make up the integrated plant. The subsystems included are the mineralization subsystem, the Alkalinity Based on Low Energy (ABLE) subsystem, the waste calcium oxide processing subsystem, and the fiber cement board production subsystem. The fully integrated plant is now capable of capturing CO2 from various sources (gas and coal) and mineralizing into a reactive calcium carbonate binder and subsequently producing commercial size (4ftx8ft) fiber cement boards. The topical report provides a description of the “as built” design of these subsystems and the results of the commissioning activities that have taken place to confirm operability. At the end of Phase 2b, the CCMP pilot demonstration is fully ready for testing.

Clean Coal Technology↗

Flue-gas carbon capture on carbonaceous sorbents: Toward a low-cost multifunctional Carbon Filter for 'Green' energy producers

A low-pressure Carbon Filter Process (patent pending) is proposed to capture carbon dioxide (CO{sub 2}) from flue gas. This filter is filled with a low-cost carbonaceous sorbent, such as activated carbon or charcoal, which has a high affinity (and, hence, high capacity) to CO{sub 2} but not to nitrogen (N{sub 2}). This, in turn, leads to a high CO{sub 2}/N{sub 2} selectivity, especially at low pressures. The Carbon Filter Process proposed in this work can recover at least 90% of flue-gas CO{sub 2} of 90%+ purity at a fraction of the cost normally associated with the conventional amine absorption process. The Carbon Filter Process requires neither expensive materials nor flue-gas compression or refrigeration, and it is easy to heat integrate with an existing or grassroots power plant without affecting the cost of the produced electricity too much. An abundant supply of low-cost CO{sub 2} from electricity producers is good news for enhanced oil recovery (EOR) and enhanced coal-bed methane recovery (ECBMR) operators, because it will lead to higher oil and gas recovery rates in an environmentally sensitive manner. A CO{sub 2}-rich mixture that contains some nitrogen is much less expensive to separate from flue-gas than pure CO{sub 2}; therefore, mixed CO{sub 2}/N{sub 2}-EOR and CO{sub 2}/N{sub 2}-ECBMR methods are proposed to maximize the overall carbon capture and utilization efficiency.

01 COAL, LIGNITE, AND PEAT↗

Integrated Flue Gas Purification and Latent Heat Recovery for Pressurized Oxy-Combustion (Final Scientific/Technical Report)

Pressurized oxy-combustion has been identified by DOE as a transformational technology for coal power with carbon capture due to the advantages that are realized when the combustion process is pressurized. The staged pressurized oxy-combustion (SPOC) process is particularly attractive as the efficiency of the process is almost 6 percentage points greater than that of first generation oxy-combustion. A critical component of the SPOC process, and potentially other pressurized combustion processes, is the Direct Contact Cooler (DCC) where the latent heat of the flue gas moisture is recovery to improve plant efficiency while simultaneously removing SO x and NO x from the flue gas, so that the FGD and de-NO x processes can be eliminated, and the cost of electricity minimized. The objective of this R&D effort was to advance the TRL of the DCC technology, which included performance testing at a 100 kW scale to validate the process and obtain key engineering data for scale-up. A collateral objective was to study the gas- and liquid-phase kinetics, and the development of a systematic chemical mechanism validated by experimental data. Experiments in a bench-scale stirred reactor provided an updated understanding of the liquid chemistry and the effects of temperature and pH. This information was used to develop a reduced reaction mechanism, which was subsequently incorporated in an ASPENbased process model, to allow for evaluation of the DCC at full scale. A small-pilot DCC column was designed, constructed and tested using simulated flue gas at the pressurized oxy-combustion test facility at Washington University in St. Louis. In the majority of tests, the SO 2 capture approached 100%, making the NO x capture the primary metric of capture efficiency. An NO x capture efficiency of 90% was achieved when the gas residence time was 95 seconds, demonstrating that high capture rates can be attained with reasonable reactor size. At higher temperatures (up to 200°C inlet gas temperature) the total NO x scrubbing efficiency was reduced by approximately 10% (compared to room temp.) and this was attributed to a reduced NO oxidation rate. A significant amount of SO 2 was present in the gas outlet (10%) only when the temperature was high and the N:S ratio was low (N/S < 1), which highlights the necessity of controlling the NOx concentration in the flue gas for complete sulfur scrubbing. After incorporated our optimized chemical mechanism into an ASPEN process model, various full-scale configurations of the DCC were evaluate, and the results indicate that the proposed DCC can accomplish its intended goals at full scale and at a modest size. Thus, the results of this project indicate that the DCC is a promising technology for recovery of the latent heat of the moisture in the flue gas while simultaneously scrubbing the nitrogen and sulfur oxides, thus enabling pressurized oxy-combustion, in general, and the SPOC process, in particular.

01 COAL, LIGNITE, AND PEAT↗

Removal and recovery of compressed CO{sub 2} from flue gas by a novel thermal swing chemisorption process

A synopsis of the published literature on removal of CO{sub 2} from a flue gas is given. A novel thermal swing chemisorption (TSC) process concept is proposed for removal and recovery of compressed CO{sub 2} from a flue gas without precompression, predrying, or precooling. The process uses Na{sub 2}O promoted alumina as a reversible CO{sub 2} selective chemisorbent in conjunction with the principles of rapid thermal swing adsorption for direct production of compressed CO{sub 2} from a flue gas. Several complementary process steps are used in the design to compress the product CO{sub 2} and to achieve high CO{sub 2} recovery and sorbent capacity utilization. Judicious steam purge steps are used for highly efficient sot-bent regeneration and to minimize the steam requirement. The CO{sub 2} chemisorption characteristics of the sorbent are reviewed and a model simulation of the TSC process performance is reported.

01 COAL, LIGNITE, AND PEAT↗

Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Process analysis of CO{sub 2} capture from flue gas using carbonation/calcination cycles

Process analysis of CO{sub 2} capture from flue gas using Ca-based carbonation/calcination cycles is presented here. A carbonation/calcination system is composed essentially of two reactors (an absorber and a regenerator) with Ca-based sorbent circulating between the two reactors (assumed here as fluidized beds). CO{sub 2} is, therefore, transferred from the absorber to the regenerator. Because of the endothermicity of the calcination reaction, a certain amount of coal is burned with pure oxygen in the regenerator. Detailed mass balance, heat balance and cost of electricity and CO{sub 2} mitigation for the carbonation/calcination cycles with three Ca-based sorbents in dual fluidized beds were calculated and analyzed to study the effect of the Ca-based sorbent activity decay on CO{sub 2} capture from flue gas. The three sorbents considered were: limestone, dolomite and CaO/Ca{sub 12}Al{sub 14}O{sub 33} (75/25 wt %) sorbent. All results, including the amount of coal and oxygen required, are presented with respect to the difference in calcium oxide conversion between the absorber and the regenerator, which is an important design parameter. Finally, costs of electricity and CO{sub 2} mitigation costs using carbonation/calcination cycles for the three sorbents were estimated. The results indicate that the economics of the carbonation/calcination process compare favorably with competing technologies for capturing CO{sub 2}.

01 COAL, LIGNITE, AND PEAT↗

Novel Transformational Membranes and Process for CO 2 Capture from Flue Gas (FE0031731)

The objectives of this project are to develop a cost-effective design and fabrication process for a novel transformational membrane and its membrane modules that capture CO 2 from flue gas. Optimization of the novel transformational membrane, scale-up of the membrane to a prototype size of about 20" wide in continuous roll-to-roll fabrication, and construction and testing of a skid for the integrated membrane process will be performed. For the design of this membrane, we use a cost-effective polymer support and coat a thin top layer of the membrane. The simplicity of this membrane design offers a low cost for the membrane element in commercial spiral-wound (SW) configuration (<$2.00/ft 2 or $21.5/m 2 ). The prototype membrane will be used to fabricate 6 pilot-size membrane modules (each about 20" length, 3 modules each at the commercial-size diameter of 8 inches with 35 m 2 membrane area for Stage 1 and 3 modules each at 5-inch diameter with 12 m 2 membrane area for Stage 2) for testing with simulated flue gas at OSU and with actual flue gas at the National Carbon Capture Center, Wilsonville, AL using the skid to capture the CO 2 (at 60 – 90%) with at least 95% CO 2 purity. The prototype membrane modules will be in commercial SW configuration with a minimal pressure drop (<0.103 bar/meter (1.5 psi/meter)). These objectives have been achieved successfully.

20 FOSSIL-FUELED POWER PLANTS↗

Vanadium As a Potential Membrane Material for Carbon Capture: Effects of Minor Flue Gas Species

Vanadium and its surface oxides were studied as a potential nitrogen-selective membrane material for indirect carbon capture from coal or natural gas power plants. The effects of minor flue gas components (SO 2 , NO, NO 2 , H 2 O, and O 2 ) on vanadium at 500–600 °C were investigated by thermochemical exposure in combination with X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and in situ X-ray diffraction (XRD). The results showed that SO 2 , NO, and NO 2 are unlikely to have adsorbed on the surface vanadium oxides at 600 °C after exposure for up to 10 h, although NO and NO 2 may have exhibited oxidizing effects (e.g., exposure to 250 ppmv NO/N 2 resulted in an 2.4 times increase in surface V 2 O 5 compared to exposure to just N 2 ). We hypothesize that decomposition of surface vanadium oxides and diffusion of surface oxygen into the metal bulk are both important mechanisms affecting the composition and morphology of the vanadium membrane. Additionally, the results and hypothesis suggest that the carbon capture performance of the vanadium membrane can potentially be strengthened by material and process improvements such as alloying, operating temperature reduction, and flue gas treatment.

36 MATERIALS SCIENCE↗

Role of SO{sub 2} for elemental mercury removal from coal combustion flue gas by activated carbon

In order to clarify the role of SO{sub 2} in the removal of mercury from coal combustion flue gas by activated carbon, the removal of Hg{sup 0} vapor from simulated coal combustion flue gas containing SO{sub 2} by a commercial activated carbon (AC) was studied. The Hg{sup 0} removal experiments were carried out in a conventional flow type packed bed reactor system with simulated flue gases having a composition of Hg{sup 0} (4.9 ppb), SO{sub 2} (0 or 500 ppm), CO{sub 2} (10%), H{sub 2}O (0 or 15%), O{sub 2} (0 or 5%), and N{sub 2} (balance gas) at a space velocity (SV) of 6.0 x 104 h{sup -1} in a temperature rang 60-100 {sup o}C. It was found that, for SO{sub 2} containing flue gas, the presence of both O{sub 2} and H{sub 2}O was necessary for the removal of Hg{sup 0} and the Hg{sup 0} removal was favored by lowering the reaction temperature in the order of 60 > 80 > 100{sup o}C. The presence of SO{sub 2} in the flue was essential for the removal of Hg{sup 0} by untreated activated carbon. The activated carbons pretreated with SO{sub 2} or H{sub 2}SO{sub 4} prior to the Hg{sup 0} removal also showed Hg{sup 0} removal activities even in the absence of SO{sub 2}; however, the presence of SO{sub 2} also suppressed the Hg{sup 0} removal of the SO{sub 2}-pretreated AC or H{sub 2}SO{sub 4} preadded AC. 19 refs., 11 figs.

01 COAL, LIGNITE, AND PEAT↗

High Performance Solvent for NGCC Flue Gas CO 2 Capture (Final Technical Report)

Amine-based solvent absorption is the most mature and reliable technology for large scale CO 2 capture, dating back to the 1930s when monoethanolamine (MEA) was used to treat acid gases from oil refineries. However, while strategic advancements have optimized the CO2 capture process, the cost of capture remains high, where current estimates suggest that CO 2 capture costs are around $\$$72/tonne of CO 2 . To address this, solvent development and optimization have become a focus of current research. This project sought to develop a high-performance solvent to reduce the overall cost of CO 2 capture from NGCC flue gas. Here, solvent optimization focused on: (1) reducing the energy required for CO 2 desorption in a reboiler, (2) improving CO 2 absorption and desorption reaction kinetics, (3) improving solvent stability, and (4) reducing environmental impacts. Susteon has developed and evaluated a promoted solvent, Sustenol™, for NGCC flue gas CO 2 capture. The optimized Sustenol™ also shows a higher dynamic CO 2 absorption capacity of ~0.5 mol CO2 /mol amine compared to 0.25 mol CO2 /mol amine for 30 wt% MEA. Additionally, the solvent is oxidatively, thermally and hydrothermally stable, which leads to lower solvent loss and emissions. These advancements have resulted in a solvent regeneration energy of 2.16 GJ/tonne of CO 2 which is >30% lower than current state-of-the-art commercial and emerging solvents. Combined with empirical data from the bench and pilot scale testing, this preliminary TEA study indicated the cost of CO 2 capture by Sustenol™ for 97% CO 2 removal at $\$$54/tonne and for 90% removal at $\$$49/tonne, with a pathway to achieve $\$$45/tonne of CO 2 with continued process and solvent advancements. Susteon has developed a technology roadmap to reduce the cost of CO 2 capture to <$\$$45/tonne for NGCC flue gas. Susteon plans to derisk this technology for commercial deployment through comprehensive solvent degradation testing, long-term testing in a pilot plant at 5 tonne CO2 /day and demonstration scale testing at 100 tonne CO2 /day with NGCC flue gas and engineering design studies to qualify Sustenol™ as a drop-in replacement solvent.

03 NATURAL GAS↗

TEM study the corrosion behavior of the low alloy steels developed for flue gas desulfurization system

Highlights: • Corrosion mechanism of low alloy steels for flue gas desulfurization was studied. • An amorphous corrosion layer enriched with Fe, O, S formed on the blank specimen. • Added Cu concentrated, crystallized and grown to particles in corrosion layer. • Corrosion resistance of the steels depended on the form of Cu in corrosion layer. • Sb addition slows the crystallization and growth of Cu particles in corrosion layer. - Abstract: This study investigated the corrosion behavior and underline mechanisms of low alloy steels with a minor addition of 0.4 wt% Cu, 0.2 wt% Ni, 0.1 wt% Sb and 0.05 wt% Co developed for a flue gas desulfurization (FGD) system. Corrosion tests were carried out in an aggressive solution of 16.9 vol% H{sub 2}SO{sub 4} + 0.35 vol% HCl + Bal. H{sub 2}O at 60 °C for up to 48 h. The experimental results revealed enrichment of the additional elements (Cu, Sb and Ni) in the corrosion layer, whose concentration increased with test time. As the concentrations of Cu increased, the crystallization and growth of the Cu particles (from several nm to 320 nm)) within the corrosion layer was accelerated. At the initial stage of the test, a continuous amorphous layer rich with the additional elements formed and covered the surface of the steel, which then gradually developed defects, pores and cracks, as the crystallization and growth of Cu particles with the elapse of time. The results indicated that the corrosion resistance of the low alloy steel depends on the existence form of Cu in the corrosion layer, i.e., as solute atoms or as nanoparticles strengthened the corrosion layer and increased corrosion resistance. As the coarsening of Cu particles weakened the corrosion layer and deteriorated the corrosion resistance.

36 MATERIALS SCIENCE↗

Numerical simulation of multiphase flow and collision humidification in the multifluid alkaline spray generator for a novel semidry flue gas desulfurization system

A hybrid Eulerian-Lagrangian model was developed to simulate gas-droplet-particle multiphase flow and the collision humidification between sorbent particles and spray droplets in the confined multifluid alkaline spray generator for a novel semidry flue gas desulfurization system. In this model, the motions of discrete phases were tracked simultaneously by using a stochastic trajectory approach, and a probability model of droplets catching particles was presented to judge whether sorbent particles were caught with direct simulation Monte Carlo method. Numerical humidification efficiency of sorbent particles is validated by the experimental one deduced from the measured desulfurization efficiency. The effects of flue gas flow rate, spray droplet diameter, sorbent particle diameter, and particle injection location on the humidification efficiency were optimized. Numerical results show that the collision humidification efficiency of sorbent particles increases significantly at the axial distance of 1.67 times the generator diameter from the nozzle tip and reaches 78.5% without recirculation flow in the alkaline spray generator when the ratio of flue gas mass flow rate to spray water mass flow rate is 6.7. Moreover, there is an optimal droplet diameter ranging from 125 to 150 {mu} m and an optimal particle injection location corresponding to the maximum humidification efficiency in this paper.

01 COAL, LIGNITE, AND PEAT↗

JV Task 124 - Understanding Multi-Interactions of SO3, Mercury, Selenium, and Arsenic in Illinois Coal Flue Gas

This project consisted of pilot-scale combustion testing with a representative Illinois basin coal to explore the multi-interactions of SO{sub 3}, mercury, selenium and arsenic. The parameters investigated for SO{sub 3} and mercury interactions included different flue gas conditions, i.e., temperature, moisture content, and particulate alkali content, both with and without activated carbon injection for mercury control. Measurements were also made to track the transformation of selenium and arsenic partitioning as a function of flue gas temperature through the system. The results from the mercury-SO{sub 3} testing support the concept that SO{sub 3} vapor is the predominant factor that impedes efficient mercury removal with activated carbon in an Illinois coal flue gas, while H{sub 2}SO{sub 4} aerosol has less impact on activated carbon injection performance. Injection of a suitably mobile and reactive additives such as sodium- or calcium-based sorbents was the most effective strategy tested to mitigate the effect of SO{sub 3}. Transformation measurements indicate a significant fraction of selenium was associated with the vapor phase at the electrostatic precipitator inlet temperature. Arsenic was primarily particulate-bound and should be captured effectively with existing particulate control technology.

01 COAL, LIGNITE, AND PEAT↗