Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utah FORGE 4-2541: Optimization and Validation of a Plug-and-Perf Stimulation Treatment Design - Workshop Presentation

This is a presentation on the Optimization and Validation of a Plug-and-Perf Stimulation Treatment Design at Utah FORGE project by Fervo Energy, presented by Sireesh Dadi. The project's objective was to develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS system. These factors include: achieving sufficient injectivity to support high cross-well flow rates, distributing flow evenly across the wellbore and reservoir, and overcoming the effects of stress heterogeneity, stress shadowing, and variations in natural fracture properties during the stimulation treatment. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 7, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

Enhancing Even Gas Distribution in Porous Media with Radial Flow

Packed beds, such as those used in thermal energy storage (TES) systems, typically use flow from one end to the other. This axial flow configuration leads to inefficiencies due to dispersion effects and high pressure drop. Instead of axial flow, this work proposes radial flow in packed beds, where a central tube provides flow that transports fluid from the center to the bed’s wall. Radial flow could be a promising solution to increase the efficiency of charging/discharging processes in TES systems. For instance, studies have been conducted on the thermal behavior during the charging process using radial flow and axial flow, and it was found that radial flow is better than axial flow in terms of thermal performance, where more energy can be stored in the storage tank during the charging process. However, the design of the radial pipe should be optimized to improve even flow distribution. In this work, numerical investigations on different designs were analyzed to enhance even flow gas distribution in the porous media when using this radial technique. This work shows the impact of different parameters on the even flow distribution into the packed bed for two different designs: 1) one radial tube at the center to provide the radial flow along with an annular tube at the wall to receive the flow, and 2) one radial tube at the center and four radial tubes at the wall. Air was used as fluid and 6 mm alumina beads as packing materials. Computational fluid dynamics (CFD) models in COMSOL Multiphysics were used to simulate the behavior of air flow through the piping and packed bed. It was found that the flow into the bed from the radial tube can be affected by different parameters: space between the holes, size/diameter of the holes, number of segments/zones, number of the holes in each zone and the length of each zone.

Beck, David M.↗

Liquid flow and distribution in unsaturated porous media

Flow and transport in permeable or porous media and microchannels occurs in a variety of situations in micro- and reduced-gravity environments, many of them associated with environmental control and life support systems. While the role of gravity is limited, due to the typically small size scales associated permeable media, gravity, at the very least, affects the overall disposition of fluid in a macroscopic system. This presentation will discuss examples where the absence of gravity affects flow and phase distribution in selected examples of unsaturated flow and transport of heat and mass in porous media and microchannels that are pertinent to spacecraft systems.

Alexander, J. Iwan↗

Computer Program Predicts Turbine-Stage Performance

MTSBL updated version of flow-analysis programs MERIDL and TSONIC coupled to boundary-layer program BLAYER. Method uses quasi-three-dimensional, inviscid, stream-function flow analysis iteratively coupled to calculated losses so changes in losses result in changes in flow distribution. Manner effects both configuration on flow distribution and flow distribution on losses taken into account in prediction of performance of stage. Written in FORTRAN IV.

Boyle, Robert J.↗

Development of a Distribution Optimal Power Flow Federate for Open-Source OEDI-SI Platform

Increasing numbers of distributed generators in the electric power distribution networks require developing a control strategy to optimize solutions in real time. Linearized optimal distribution flow development has seen growth and acceptance in the distribution systems literature for efficiently modeling the \glspl{opf} for distribution systems. This paper examines the implementation and integration procedure for linearized optimal distribution flow federate to \gls{oedisi} platform. Specifically, we discuss i) the usage of the \gls{oedisi} platform, ii) obtaining a tractable solution using developed \gls{opf} federate, and iii) validation of solutions and bench-marking the \gls{oedisi} platform with developed \gls{opf} federate using OpenDSS. In brief, we demonstrate how a general linearized optimal distribution flow federate can be developed and integrated with a co-simulation environment to mimic real-world examples. The efficacy of the proposed method is demonstrated using the IEEE 123-bus test system under different scenarios to obtain a tractable solution and compare its results.

Sadnan, Rabayet↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

RSRM 10 percent Scale Model Drilled Hole Plate Tests

The RSRM 10% Scaled Model under design will make use of drilled hole liners to provide mass addition along the axial length of the model. The model will have two sets of liners in use at a time. The outer most liner is a flow distribution tube, the purpose of which is to help distribute the flow evenly over each model segment. The inner most liner will simulate the propellant burning surface at a burn time of 80 seconds. This liner will replicate as closely as possible the actual geometry of the full scale RSRM at the 80 second burn time. In order to obtain the correct mass flow rate for the burn time selected, it is necessary to determine the porosity of the holes drilled in each liner and the performance of those holes. The pressure drop across the liners directly effects the uniformity of the flow in the axial direction for a given model section. It is desired to have a pressure drop across the liners which is greater than the axial pressure drop in a given section. However, the pressure drop across the liner also has a bearing on the structural soundness of the model. The performance of the model was determined analytically, but there was some uncertainty as to the value of the discharge coefficient used. This uncertainty was the impetus for these drilled hole plate tests. Experimentally obtaining the discharge coefficients for sample plates of the porosity to be used in the model would increase the fidelity of the model design. These tests were developed in order to provide the required information with the least amount of testing time and hardware.

Purinton, David C.↗

Asymmetric configurable double-sided manifold micro-channel cold plates

A cold plate having a manifold includes a recess extending from a first side to a second side of the manifold, where the recess includes openings to the recess positioned lengthwise along the first side and a single opening to the recess on the second side, an inlet and an outlet fluidly coupled to the recess, a plurality of plates fastened to the first side enclosing the openings, a heat sink fastened to the second side enclosing the single opening on the second side, and a plurality of fluid cores one of each positioned between each of the plurality of plates and the heat sink. The plurality of fluid cores include a flow distribution insert, a first plate fin positioned between the flow distribution insert and the heat sink fastened to the second side, and a second plate fin positioned between the flow distribution insert and the heat sink.

Zhou, Feng↗

Method of Estimating the Incompressible-flow Pressure Distribution of Compressor Blade Sections at Design Angle of Attack

A method was devised for estimating the incompressible-flow pressure distribution over compressor blade sections at design angle of attack. The theoretical incremental velocities due to camber and thickness of the section as an isolated airfoil are assumed proportional to the average passage velocity and are modified by empirically determined interference factors. Comparisons were made between estimated and test pressure distributions of NACA 65-series sections for typical conditions. Good agreement was obtained.

COMPRESSOR FLOW THEORY AND EXPERIMENT↗

Nonintrusive Temperature and Velocity Measurements in a Hypersonic Nozzle Flow

Distributions of nitric oxide vibrational temperature, rotational temperature and velocity have been measured in the hypersonic freestream at the exit of a conical nozzle, using planar laser-induced fluorescence. Particular attention has been devoted to reducing the major sources of systematic error that can affect fluorescence tempera- ture measurements, including beam attenuation, transition saturation effects, laser mode fluctuations and transition choice. Visualization experiments have been performed to improve the uniformity of the nozzle flow. Comparisons of measured quantities with a simple one-dimensional computation are made, showing good agreement between measurements and theory given the uncertainty of the nozzle reservoir conditions and the vibrational relaxation rate.

OByrne, S.↗

Solving Optimal Power Flow for Distribution Networks with State Estimation Feedback

Conventional optimal power flow (OPF) solvers assume full observability of the involved system states. However in practice, there is a lack of reliable system monitoring devices in the distribution networks. To close the gap between the theoretic algorithm design and practical implementation, this work proposes to solve the OPF problems based on the state estimation (SE) feedback for the distribution networks where only a part of the involved system states are physically measured. The SE feedback increases the observability of the under-measured system and provides more accurate system states monitoring when the measurements are noisy. We analytically investigate the convergence of the proposed algorithm. The numerical results demonstrate that the proposed approach is more robust to large pseudo measurement variability and inherent sensor noise in comparison to the other frameworks without SE feedback.

distirbution systems↗

Flight Investigation of the Surface Pressure Distribution and Flow Field Around an Elliptical Spinner

A flight investigation has been made of the surface pressure distribution and the flow field around a dummy, nonrotating, elliptical spinner over a Mach number range from 0.65 to 0.95, which corresponds to a Reynolds number range from about 1.6 x 10(exp 6) per foot to about 3.9 x 10(exp 6) per foot. The results showed that free-stream conditions were approximated from about 15 to 90 percent of the spinner length, but the local Mach number in the propeller plane varied from about 5 percent less than free stream at a Mach number of 0.65 to about 10 percent less than free stream at a mach number of 0.95.

Thomas, Lovic P., III↗

Coolant-Flow Calibrations of Three Simulated Porous Gas-Turbine Blades

An investigation was conducted at the NACA Lewis laboratory to determine whether simulated porous gas-turbine blades fabricated by the Eaton Manufacturing Company of Cleveland, Ohio would be satisfactory with respect to coolant flow for application in gas-turbine engines. These blades simulated porous turbine blades by forcing the cooling air onto the blade surface through a large number of chordwise openings or slits between laminations of sheet metal or wire. This type of surface has a finite number of openings, whereas a porous surface has an almost infinite number of smaller openings for the coolant flow. The investigation showed that a blade made of sheet-metal laminations stacked on a support member that passed up through the coolant passage was completely unsatisfactory because of extremely poor coolant flow distribution over the blade surface. The flow distribution for two wire-wound blades was more uniform, but the pressure drop between the coolant supply pressure and the local pressure on the outside of the blades was too low by a factor ranging from 3 to 3.5 for the required coolant flow rates. The pressure drop could be increased by forcing the wires closer together during blade fabrication.

Esger, Jack B.↗