Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FELs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Key Laser Technologies for X-Ray FELs

In the final project period, we demonstrated sub femtosecond timing distribution over a 1.2 km polarization-maintaining (PM) fiber-optic link using balanced optical cross-correlators (BOCs) for link stabilization. By eliminating polarization mode dispersion, link operation for 16 days maintained 0.6 fs RMS timing drift and during a 3-day interval only 0.13 fs drift, which corresponds to a stability level of 10-21. To improve the overall system efficiency and robustness, we developed fiber-coupled, hybrid-integrated BOCs using waveguides in periodically-poled KTiOPO4 (PPKTP). The measured second-harmonic conversion efficiency in the waveguides is a factor of 50 higher than that of bulk-optic crystals. Characterization of 1st-generation devices shows performance comparable to free-space BOCs, with the potential for significant improvement in future devices. For optical-to-RF conversion, we developed two balanced optical-microwave phase detectors (BOM-PD) based on the Sagnac and Mach-Zehnder interferometers. RF extraction using BOM-PDs in phase-locked loops yielded sub-10-fs residual timing jitter for locking bandwidths on the order of several hundred kHz. Finally, we characterized the timing jitter of ultralow-noise Ti:Sapphire oscillators, demonstrating an unprecedented 13 as of jitter integrated over the entire Nyquist band. Our measurements agreed well with theory, confirming our models for quantum-limited laser noise. Measurements of commercially available solid-state lasers at 1550 nm showed that there are laser sources already available with sufficiently low noise to achieve sub-femtosecond performance as master oscillators within a timing distribution system.

42 ENGINEERING↗

Compact FEL-driven inverse compton scattering gamma-ray source

Many research and applications areas require photon sources capable of producing gamma-ray beams in the multi-MeV energy range with reasonably high fluxes and compact footprints. Besides industrial, nuclear physics and security applications, a considerable interest comes from the possibility to assess the state of conservation of cultural assets like statues, columns etc., via visualization and analysis techniques using high energy photon beams. Computed Tomography scans, widely adopted in medicine at lower photon energies, presently provide high quality three-dimensional imaging in industry and museums. We explore the feasibility of a compact source of quasi-monochromatic, multi-MeV gamma-rays based on Inverse Compton Scattering (ICS) from a high intensity ultra-violet (UV) beam generated in a free-electron laser by the electron beam itself. This scheme introduces a stronger relationship between the energy of the scattered photons and that of the electron beam, resulting in a device much more compact than a classic ICS for a given scattered energy. As a result, the same electron beam is used to produce gamma-rays in the 10–20 MeV range and UV radiation in the 10–15 eV range, in a ~4 × 22 m 2 footprint system.

43 PARTICLE ACCELERATORS↗

Resonant inelastic x-ray scattering in warm-dense Fe compounds beyond the SASE FEL resolution limit

Resonant inelastic x-ray scattering (RIXS) is a widely used spectroscopic technique, providing access to the electronic structure and dynamics of atoms, molecules, and solids. However, RIXS requires a narrow bandwidth x-ray probe to achieve high spectral resolution. The challenges in delivering an energetic monochromated beam from an x-ray free electron laser (XFEL) thus limit its use in few-shot experiments, including for the study of high energy density systems. Here we demonstrate that by correlating the measurements of the self-amplified spontaneous emission (SASE) spectrum of an XFEL with the RIXS signal, using a dynamic kernel deconvolution with a neural surrogate, we can achieve electronic structure resolutions substantially higher than those normally afforded by the bandwidth of the incoming x-ray beam. We further show how this technique allows us to discriminate between the valence structures of Fe and Fe2O3, and provides access to temperature measurements as well as M-shell binding energies estimates in warm-dense Fe compounds.

74 ATOMIC AND MOLECULAR PHYSICS↗

In situ focus characterization by ablation technique to enable optics alignment at an XUV FEL source

In situ focus characterization is demonstrated by working at an extreme ultraviolet (XUV) free-electron laser source using ablation technique. Design of the instrument reported here allows reaching a few micrometres resolution along with keeping the ultrahigh vacuum conditions and ensures high-contrast visibility of ablative imprints on optically transparent samples, e.g., PMMA. This enables on-line monitoring of the beam profile changes and thus makes possible in situ alignment of the XUV focusing optics. A good agreement between focal characterizations retrieved from in situ inspection of ablative imprints contours and from well-established accurate ex situ analysis with Nomarski microscope has been observed for a typical micro-focus experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast broad-band photon detector based on quantum well devices and charge-integrating electronics for non-invasive FEL monitoring

The recent evolution of free-electron lasers has not been matched by the development of adequate beam-monitoring instrumentation. However, for both experimental and diagnostics purposes, it is crucial to keep such photon beams under control, avoiding at the same time the absorption of the beam and the possible destruction of the detector. These requirements can be fulfilled by utilizing fast and non-invasive photon detectors operated in situ, upstream from the experimental station. From this perspective, sensors based on Quantum Well (QW) devices can be the key to detecting ultra-short light pulses. In fact, owing to their high electron mobility, InGaAs/InAlAs QW devices operated at room temperature exhibit sub-nanosecond response times. Their direct, low-energy band gap renders them capable of detecting photons ranging from visible to X-ray. Furthermore, the 2D electron gas forming inside the QW is responsible for a charge amplification mechanism, which increases the charge collection efficiency of these devices. In order to acquire the signals produced by these QW sensors, a novel readout electronics has been developed. It is based on a high-speed charge integrator, which allows short, low-intensity current pulses to be read within a 50-ns window. The integrated signal is acquired through an ADC and the entire process can be performed at a 10-MHz repetition rate. This work provides a detailed description of the development of the QW detectors and the acquisition electronics, as well as reporting the main experimental results, which show how these tools are well suited for the realization of fast, broad-band beam monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photochemical pathways in nucleobases measured with an X-ray FEL

The conversion of light energy into other molecular energetic degrees of freedom is often dominated by ultrafast, non-adiabatic processes. Femtosecond spectroscopy with optical pulses has helped in shaping our understanding of crucial processes in molecular energy-conversion. The advent of new, ultrashort and bright X-ray free electron laser sources opens the possibility to use X-ray-typical element and site sensitivity for ultrafast molecular research. We introduce two types of spectroscopy, ultrafast Auger and ultrafast X-ray absorption spectroscopy, and discuss their sensitivity to molecular processes. While Auger spectroscopy is able to monitor bond distance changes in the vicinity of an X-ray created core hole, near-edge absorption spectroscopy can deliver high-fidelity information on non-adiabatic transitions involving lone-pair orbitals. We display these features on the example of the UV-excited nucleobase thymine, investigated at the oxygen K-edge. We find a C–O bond elongation in the Auger data in addition to ππ*/nπ* non-adiabatic transition in X-ray near-edge absorption. We compare the results from both methods and draw a conclusive scenario of non-adiabatic molecular relaxation after UV excitation. This article is part of the theme issue ‘Measurement of ultrafast electronic and structural dynamics with X-rays’.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Startup regime of high-efficiency tapering-enhanced FEL oscillator

In this paper, we present a design of a high-efficiency high-gain free-electron laser oscillator based on the use of a strongly tapered undulator for extracting energy from high-brightness electron beams. We provide an analytical model of the setup followed by numerical simulations for lasing at the wavelength of 13.5 nm. We discuss the optimization of the system in steady state and the conditions necessary for the pass-per-pass buildup of the power from shot noise level. We propose the use of fast phase shifters as a way to accelerate the buildup. Finally, we present time-dependent simulations of the oscillator and discuss the role of spectral filtering. The optimized working point yields a total energy conversion efficiency from the electron beam to output radiation above 1% at the wavelength of 13.5 nm.

Beam dynamics↗