Deformation of fast neutron spectrum in concrete and water
Fast neutron spectra in concrete and water used as shielding
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fast neutron spectra in concrete and water used as shielding
Purpose: Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. Methods: A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al{sub 2}O{sub 3}:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7 cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0–150 cGy. Results: OSLD measurement uncertainties were lowered to within ±2%–3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer’s recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Conclusions: Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and minimizing transient fading effects.
The analysis of clinical use of neutron therapy with 6 MeV fast neutrons compared to conventional radiation therapy was carried out. The experience of using neutron and mixed neutron and photon therapy in patients with different radio-resistant malignant tumors shows the necessity of further studies and development of the novel approaches to densely-ionizing radiation. The results of dosimetry and radiobiological studies have been the basis for planning clinical programs for neutron therapy. Clinical trials over the past 30 years have shown that neutron therapy successfully destroys radio-resistant cancers, including salivary gland tumors, adenoidcystic carcinoma, inoperable sarcomas, locally advanced head and neck tumors, and locally advanced prostate cancer. Radiation therapy with 6.3 MeV fast neutrons used alone and in combination with photon therapy resulted in improved long-term treatment outcomes in patients with radio-resistant malignant tumors.
Reliable fast-neutron evaluation can be entirely encapsulated in the reaction model and related input. Ta181 is a particularly relevant case due to extraordinary coverage of various observables by differential experiments that offer much help and relatively little headache. Differences from the similar ENDF/B-VIII evaluation include: more advanced modeling (CC OMP, MSD, MSC, decay schemes), more careful selection of models and parameters, new experimental data, and isomers. Overall, improved agreement with differential data and hints of better performance in integral testing.
High doses of fast neutrons is detrimental to the performance of most common solid-state devices such as diodes and transistors. The ionizing effect is observed in particular for diodes used as simple integrated temperature sensors, or thermo-diodes, when their junction voltage is measured at constant current bias. In this work, we present a low-power and in situ mitigation technique based on Silicon-on-Insulator (SOI) micro-hot-plates to recover thermo-diodes. The basic operating principle consists in annealing the temperature-sensitive diodes integrated on the membrane during or after their irradiation in order to restore similar sensing characteristics over time. We measured thermo-diodes integrated to micro-hot-plates during their irradiation by fast neutrons (23 MeV peak) with total doses about 2.97±0.08 kGy. The membrane annealing is taking place at 450 deg. C using 40 mW of electrical power. Thanks to the annealing, the diode keeps a total measurement error below 0.5 deg. C. In this harsh radiation environment and beside the good tolerance of the thermo-diodes and the membrane materials to the total ionizing dose, the thermo-diode located on the heating membrane keeps a constant sensitivity. The demonstrated resistance of micro-hot-plates and the integrated thermo-diodes to fast neutron radiations can extend their use in nuclear plants and for radiation detectors. (authors)
Time-of-flight measurements were performed to determine the 4 He pressurized fast neutron scintillation detectors response function and the ability of the detectors to be applied as a spectrometer. An experimentally validated neutron energy response function was used in conjunction with an iterative least squares unfolding technique to unfold a 252 Cf spontaneous fission spectrum, a PuBe (α, n) spectrum, and a deuterium-deuterium (D-D) fusion reaction spectrum. In conclusion, the ability of the detectors to retain incident neutron energies makes them suitable for applications such as nuclear non-proliferation and spent nuclear fuel monitoring.
Here this paper presents an enabling technology for high-efficiency fast-neutron detection for the Transient Reactor Test (TREAT) Facility hodoscope. The hodoscope is currently outfitted with 25.4-mm long Hornyak buttons for fast-neutron detection. However, they require improvements, as they suffer from low detection efficiency, Ĉerenkov radiation contaminating the signal, and non-linearity of detector response at large transients. To address these issues, a layered ZnS:Ag device has been constructed. The layered design provides various advantages: it incorporates greater scintillation volume, Ĉerenkov background is significantly reduced by eliminating the need for additional light guides, and the detection process is simplified by achieving gamma-ray rejection using only pulse-height discrimination. The result is a greater number of fast neutron counts with reduced background noise contaminating the signal. On being irradiated with a 252Cf source (whose neutron energy spectrum closely mimics a reactor fission spectrum), a 25.4-mm long layered device was found to exhibit an intrinsic fast-neutron detection efficiency of 8.1% for neutrons with an average energy of 2 MeV, while a 43-mm long device allows for a greater number of fast neutron to be detected, increasing the efficiency to 9.1%. Further lengthening of the device up to 20 cm has been numerically predicted to exhibit even higher efficiencies. The detectors can be mass-produced easily and inexpensively.
This is the final report of an experimental investigation of actinide glass scintillators for fast-neutron detection. It covers work performed during FY2012. This supplements a previous report, PNNL-20854 “Initial Characterization of Thorium-loaded Glasses for Fast Neutron Detection” (October 2011). The work in FY2012 was done with funding remaining from FY2011. As noted in PNNL-20854, the glasses tested prior to July 2011 were erroneously identified as scintillators. The decision was then made to start from “scratch” with a literature survey and some test melts with a non-radioactive glass composition that could later be fabricated with select actinides, most likely thorium. The normal stand-in for thorium in radioactive waste glasses is cerium in the same oxidation state. Since cerium in the 3+ state is used as the light emitter in many scintillating glasses, the next most common substitute was used: hafnium. Three hafnium glasses were melted. Two melts were colored amber and a third was clear. It barely scintillated when exposed to alpha particles. The uses and applications for a scintillating fast neutron detector are important enough that the search for such a material should not be totally abandoned. This current effort focused on actinides that have very high neutron capture energy releases but low neutron capture cross sections. This results in very long counting times and poor signal to noise when working with sealed sources. These materials are best for high flux applications and access to neutron generators or reactors would enable better test scenarios. The total energy of the neutron capture reaction is not the only factor to focus on in isotope selection. Many neutron capture reactions result in energetic gamma rays that require large volumes or high densities to detect. If the scintillator is to separate neutrons from gamma rays, the capture reactions should produce heavy particles and few gamma rays. This would improve the detection of a signal for fast neutron capture.
A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a fast-neutron tomographic imaging system developed at Oak Ridge National Laboratory. The system uses an associated particle DT (deuterium-tritium) neutron generator as the source and 25 mm × 25 mm × 100 mm plastic scintillators as the neutron detectors. Two image quality indicators were examined: 1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder and 2) a variety of short steels pins embedded radially in the surface of a shielded polyethylene cylinder. Measurements demonstrated detectability down to approximately 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution and small feature detection limit. The current DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor in the current system configuration.
Recently, a compact solid-state neutron detector capable of simultaneously detecting thermal and fast neutrons was proposed [M. Marinelli et al., Appl. Phys. Lett. 89, 143509 (2006)]. Its design is based on a p-type/intrinsic/metal layered structure obtained by Microwave Plasma Chemical Vapor Deposition (CVD) of homoepitaxial diamond followed by thermal evaporation of an Al contact and a {sup 6}LiF converting layer. Fast neutrons are directly detected in the CVD diamond bulk, since they have enough energy to produce the {sup 12}C(n,{alpha}){sup 9}Be reaction in diamond. Thermal neutrons are instead converted into charged particles in the {sup 6}LiF layer through the {sup 6}Li(n,{alpha})T nuclear reaction. These charged particles are then detected in the diamond layer. The thickness of the {sup 6}LiF converting layer and the CVD diamond sensing layer affect the counting efficiency and energy resolution of the detector both for low- (thermal) and high-energy neutrons. An analysis is carried out on the dynamics of the {sup 6}Li(n,{alpha})T and the {sup 12}C(n,{alpha}){sup 9}Be reactions products, and the distribution of the energy released inside the sensitive layer is calculated. The detector counting efficiency and energy resolution were accordingly derived as a function of the thickness of the {sup 6}LiF and CVD diamond layers, both for thermal and fast neutrons, thus allowing us to choose the optimum detector design for any particular application. Comparison with experimental results is also reported.
Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.
A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a version of the Oak Ridge National Laboratory fast neutron tomographic imaging system. Two image quality indicators were examined: (1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder, and (2) a variety of short steels pins embedded radially in the surface of a polyethylene cylinder. Measurements demonstrated detectability of about 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution. Our current simulation code takes only partial consideration of the DT generator neutron production spot size, with neutron production effectively originating at a single point. Simulations showed that features less than 2 mm should be detectable with an improved generator. Our current ING-27 DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor at present. Generators with spot sizes as small as 1 mm are commercially available. Higher-power, small–spot size associated particle generators are at the prototype stage and are expected to be commercially available soon.
We describe a method for simultaneously determining the {alpha}-ratio and k{sub eff} for fissile materials using fast neutrons. Our method is a generalization of the Hage-Cifarrelli method for determining k{sub eff} for fissile assemblies which utilizes the shape of the fast neutron spectrum. In this talk we illustrate the method using Monte Carlo simulations of the fast neutrons generated in PuO{sub 2} to calculate the fast neutron spectrum and Feynman correlations.
The construction of the fast neutron detector KNK-2-7M is briefly described. The results of the study of the detector in the pulse-counting mode are given for the fissions of {sup 237}Np nuclei in the radiator of the neutron-sensitive section and in the current mode with the separation of sectional currents of functional sections. The possibilities of determining the effective number of {sup 237}Np nuclei in the radiator of the neutronsensitive section are considered. The diagnostic possibilities of the detector in the counting mode are shown by example of the analysis of the reference data from the neutron-field characteristics in the working hall of the BR-K1 reactor. The diagnostic possibilities of the detector in the current operating mode are shown by example of the results of measuring the {sup 237}Np-fission intensity in the BR-K1 reactor power start-ups implemented in the mode of fission-pulse generation on delayed neutrons at the detector arrangement inside the reactor core cavity under conditions of a wide variation of the reactor radiation field.
The design of the fast neutron detector KNK-2-8M is outlined. The results of he detector study in the pulse counting mode with pulses from {sup 238}U nuclei fission in the radiator of the neutron-sensitive section and in the current mode with separation of functional section currents are presented. The possibilities of determination of the effective number of {sup 238}U nuclei in the radiator of the neutron-sensitive section are considered. The diagnostic capabilities of the detector in the counting mode are demonstrated, as exemplified by the analysis of reference data on characteristics of neutron fields in the BR-1 reactor hall. The diagnostic capabilities of the detector in the current mode are demonstrated, as exemplified by the results of measurements of {sup 238}U fission intensity in the power startup of the BR-K1 reactor in the fission pulse generation mode with delayed neutrons and the detector placed in the reactor cavity in conditions of large-scale variation of the reactor radiation fields.
This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.
The thermal decomposition kinetics have been determined for ammonium perchlorate crystals subjected to a fast neutron irradiation or to a fast neutron irradiation followed by a gamma-ray irradiation. Qualitatively, the radiation induced changes are similar to those obtained in this and in previous studies, with samples exposed only to gamma rays. The induction period is shortened and the rate constants, obtained from an Avrami-Erofeyev kinetic analysis, are modified. The acceleratory period constant increases and the decay period constant decreases. When compared on an equal deposited energy basis, the fast neutron induced changes are appreciably larger than the gamma-ray induced changes. Some, or all, of the fast neutron induced effects might be attributable to the introduction of localized regions of concentrated radiation damage ('spikes') by lattice atom recoils which become thermal decomposition sites when the crystals are heated.
III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.