Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Using Field-Metered Data to Quantify Annual Energy Use of Residential Portable Unit Dehumidifiers

The U.S. Energy Information Administration (EIA) reports that space heating and cooling no longer account for the majority of all residential energy consumption (they represented 47.7 percent in 2009). According to EIA, energy consumption for appliances, lighting, and electronics not only represents the majority of residential consumption, but continues to rise. Some of the decline in energy use for space heating and cooling may be attributable to better-insulated structures and population shifts to warmer climates. Those same factors may be contributing to an increased reliance on space-conditioning appliances, specifically dehumidifiers. Additionally, as the world’s climate changes, it is expected that absolute humidity will rise along with temperature. A recent study reports that continued climate warming will place significant limitations on human activity in typically hotter, more humid environments. Increased human discomfort may drive an even greater use of dehumidifiers and a resulting increase in residential energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Energy Use in Pulp & Paper with DOE’s Energy Intensive Industries Resources

The U.S. pulp and paper industry is the third-largest energy consumer in manufacturing, accounting for roughly 10% of sector energy use. Improving energy efficiency reduces operating costs and strengthens competitiveness. To support this effort, the U.S. Department of Energy (DOE), through Oak Ridge National Laboratory (ORNL), launched the Energy Intensive Industries (EII) Initiative. A two-year pilot across 45 industrial sites identified more than 4 trillion Btu/year in potential energy savings. This presentation outlines plans for a follow-up technical assistance program tailored to pulp and paper mills. Available resources include a cost-savings scoping tool, implementation planning guidance, and technical support for applying advanced methods such as Pinch Analysis for integrated process-utilities optimization. The session introduces key Pinch Analysis principles and highlights case studies demonstrating measurable improvements. ORNL also seeks industry feedback on barriers to efficiency improvements, including technology gaps and resource needs. DOE’s broader objective is to accelerate productivity and economic competitiveness across U.S. energy-intensive industries.

Kamath, Dipti [ORNL] (ORCID:0000000278739994)↗

Industrial Facility Combustion Energy Use

Facility-level industrial combustion energy use is calculated from greenhouse gas emissions data reported by large emitters (>25,000 metric tons CO2e per year) under the U.S. EPA's Greenhouse Gas Reporting Program (GHGRP, https://www.epa.gov/ghgreporting). The calculation applies EPA default emissions factors to reported fuel use by fuel type. Additional facility information is included with calculated combustion energy values, such as industry type (six-digit NAICS code), location (lat, long, zip code, county, and state), combustion unit type, and combustion unit name. Further identification of combustion energy use is provided by calculating energy end use (e.g., conventional boiler use, co-generation/CHP use, process heating, other facility support) by manufacturing NAICS code. Manufacturing facilities are matched by their NAICS code and reported fuel type with the proportion of combustion fuel energy for each end use category identified in the 2010 Energy Information Administration Manufacturing Energy Consumption Survey (MECS, http://www.eia.gov/consumption/manufacturing/data/2010/). MECS data are adjusted to account for data that were withheld or whose end use was unspecified following the procedure described in Fox, Don B., Daniel Sutter, and Jefferson W. Tester. 2011. The Thermal Spectrum of Low-Temperature Energy Use in the United States, NY: Cornell Energy Institute.

combustion↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

U.S. Manufacturing Energy Use and Greenhouse Gas Emissions Analysis

The United States (U.S.) manufacturing sector uses significant amounts of energy to convert raw materials into usable products. The U.S. manufacturing sector is estimated to consume over one quarter of all U.S. energy use. According to manufacturing energy use statistics from the U.S. Department of Energy’s Energy Information Administration (EIA), the U.S. manufacturing sector consumed 21.1 quadrillion Btu (quads) of fuel and feedstock energy [EIA 2009] in 2006. When the estimated electricity and steam losses outside the plant (offsite) are included in this total, the primary and feedstock energy consumed by U.S. manufacturing increases to 27.6 quads. Total U.S. energy consumption for all sectors in 2006 was 99.8 quads [EIA 2010a]. Of this total, the industrial sector consumed 32.5 quads, or 33%. Of this 33%, manufacturing consumed approximately 28%, while non-manufacturing sectors (including agriculture, mining, and construction) consumed the remaining 5% of industrial energy.

Brueske, Sabine↗

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrospective and Prospective Decomposition Analysis of Chinese Manufacturing Energy Use, 1995-2020

In 2010, China was responsible for nearly 20 percent of global energy use and 25 percent of energy-related carbon dioxide (CO 2 ) emissions. Unlike most countries, China’s energy consumption pattern is unique because the industrial sector dominates the country’s total energy consumption, accounting for about 70 percent of energy use and 72 percent of CO 2 emissions in 2010. For this reason, the development path of China’s industrial sector will greatly affect future energy demand and dynamics of not only China, but the entire world. A number of analyses of historical trends have been conducted, but careful projections of the key factors affecting China’s industry sector energy use over the next decade are scarce. This study analyzes industrial energy use and the economic structure of the Chinese manufacturing sector in detail. First, the study analyzes the energy use of and output from 18 industry sub-sectors. Then, retrospective (1995-2010) and prospective (2010-2020) decomposition analyses are conducted for these industrial sectors in order to show how different factors (production growth, structural change, and energy intensity change) influenced industrial energy use trends in China over the last 15 years and how they will do so over the next 10 years. The results of this study will allow policy makers to quantitatively compare the level of structural change in the past and in the years to come and adjust their policies if needed to move towards the target of less energy-intensive industries. The scenario analysis shows the structural change achieved through different paths and helps to understand the consequences of supporting or limiting the growth of certain manufacturing subsectors from the point of view of energy use and structural change. The results point out the industries that have the largest influence in such structural change

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An insight into actual energy use and its drivers in high-performance buildings

Using portfolio analysis and individual detailed case studies, we studied the energy performance and drivers of energy use in 51 high-performance office buildings in the U.S., Europe, China, and other parts of Asia. Portfolio analyses revealed that actual site energy use intensity (EUI) of the study buildings varied by a factor of as much as 11, indicating significant variation in real energy use in HPBs worldwide. Nearly half of the buildings did not meet the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) Standard 90.1-2004 energy target, raising questions about whether a building’s certification as high performing accurately indicates that a building is energy efficient and suggesting that improvement in the design and operation of HPBs is needed to realize their energy-saving potential. We studied the influence of climate, building size, and building technologies on building energy performance and found that although all are important, none are decisive factors in building energy use. EUIs were widely scattered in all climate zones. There was a trend toward low energy use in small buildings, but the correlation was not absolute; some small HPBs exhibited high energy use, and some large HPBs exhibited low energy use. We were unable to identify a set of efficient technologies that correlated directly to low EUIs. In two case studies, we investigated the influence of occupant behavior as well as operation and maintenance on energy performance and found that both play significant roles in realizing energy savings. We conclude that no single factor determines the actual energy performance of HPBs, and adding multiple efficient technologies does not necessarily improve building energy performance; therefore, an integrated design approach that takes account of climate, technology, occupant behavior, and operations and maintenance practices should be implemented to maximize energy savings in HPBs. As a result, these findings are intended to help architects, engineers, operators, and policy makers improve the design and operation of HPBs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global scenarios of urban density and its impacts on building energy use through 2050

Significance Urban density significantly impacts urban energy use and the quality of life of urban residents. Here, we provide a global-scale analysis of future urban densities and associated energy use in the built environment under different urbanization scenarios. The relative importance of urban density and energy-efficient technologies varies geographically. In developing regions, urban density tends to be the more critical factor in building energy use. Large-scale retrofitting of building stock later rather than sooner results in more energy savings by the middle of the century. Reducing building energy use, improving the local environment, and mitigating climate change can be achieved through systemic efforts that take potential co-benefits and trade-offs of both higher urban density and building energy efficiency into account.

42 ENGINEERING↗

Estimated United States Transportation Energy Use: 2005

A flow chart depicting energy flow in the transportation sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 31,000 trillion British Thermal Units (trBTUs) of energy were used throughout the United States in transportation activities. Vehicles used in these activities include automobiles, motorcycles, trucks, buses, airplanes, rail, and ships. The transportation sector is powered primarily by petroleum-derived fuels (gasoline, diesel and jet fuel). Biomass-derived fuels, electricity and natural gas-derived fuels are also used. The flow patterns represent a comprehensive systems view of energy used within the transportation sector.

02 PETROLEUM↗

Evaluation of Miscellaneous and Electronic Device Energy Use in Hospitals

Miscellaneous and electronic loads (MELs) consume about one-thirdof the primary energy used in US buildings, and their energy use is increasing faster than other end-uses. In healthcare facilities, 30percent of the annual electricity was used by MELs in 2008. This paper presents methods and challenges for estimating medical MELs energy consumption along with estimates of energy use in a hospital by combining device-level metered data with inventories and usage information. An important finding is that common, small devices consume large amounts of energy in aggregate and should not be ignored when trying to address hospital energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimates of the Global Indirect Energy-Use Emission Impacts of USA Biofuel Policy

This paper evaluates the indirect energy-use emission implications of increases in the use of biofuels in the USA between 2001 and 2010 as mandates within a dynamic global computable general equilibrium model. The study incorporates explicit markets for biofuels, petroleum and other fossil fuels, and accounts for interactions among all sectors of an 18-region global economy. It considers bilateral trade, as well as the dynamics of capital allocation and investment. Simulation results show that the biofuel mandates in the USA generate an overall reduction in global energy use and emissions over the simulation period from 2001 to 2030. Consequently, the indirect energy-use emission change or emission leakage under the mandate is negative. That is, global emission reductions are larger than the direct emission savings from replacing petroleum with biofuels under the USA RFS2 over the last decade. Under our principal scenario this enhanced the direct emission reduction from biofuels by about 66%. The global change in lifecycle energy-use emissions for this scenario was estimated to be about 93 million tons of CO2e in 2010, 45 million tons of CO2e in 2020, and an increase of 5 million tons of CO2e in 2030, relative to the baseline scenario. Sensitivity results of six alternative scenarios provided additional insights into the pattern of the regional and global effects of biofuel mandates on energy-use emissions.

02 PETROLEUM↗

IEA EBC annex 53: Total energy use in buildings—Analysis and evaluation methods

One of the most significant barriers to achieving deep building energy efficiency is a lack of knowledge about the factors determining energy use. In fact, there is often a significant discrepancy between designed and real energy use in buildings, which is poorly understood but are believed to have more to do with the role of human behavior than building design. Building energy use is mainly influenced by six factors: climate, building envelope, building services and energy systems, building operation and maintenance, occupants’ activities and behavior, and indoor environmental quality. In the past, much research focused on the first three factors. However, the next three human-related factors can have an influence as significant as the first three. Annex 53 employed an interdisciplinary approach, integrating building science, architectural engineering, computer modeling and simulation, and social and behavioral science to develop and apply methods to analyze and evaluate the real energy use in buildings considering the six influencing factors. Finally, outcomes from Annex 53 improved understanding and strengthen knowledge regarding the robust prediction of total energy use in buildings, enabling reliable quantitative assessment of energy-savings measures, policies, and techniques.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort

Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes’ space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

energy efficiency↗