Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy savings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of Topology Optimization to Achieve Energy Savings at the Urban District Level: Preprint

Advanced district thermal energy systems have the potential to achieve significant energy savings and facilitate the integration of renewable thermal resources and waste heat, contributing to reductions in carbon emissions. Such systems, also known as fifth generation district heating and cooling (5GDHC) systems, circulate water at temperatures close to ambient, and leverage electrically-driven water-source heat pumps located at connected buildings to further temper the water. However, barriers exist to the adoption of 5GDHC systems, including the factorial growth in potential network configurations as a function of the number of considered buildings. Topology optimization, which seeks to answer the questions, “Which is the best subset of buildings, if any, to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?” can accelerate the adoption of 5GDHC systems. This study is part of an effort to develop a topology optimization framework for district thermal energy systems. In this study, a heuristic for one aspect of the topology optimization problem---the use of the minimal spanning tree network to connect a given set of buildings at the least life cycle cost---is validated.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Performance Characterization and Energy Savings Assessment of a Radial Flux Surface Permanent Magnet Motor Technology

This project is part of the National Renewable Energy Laboratory's (NREL's) "Commercialization Assistance Program" to provide technical expertise to help emerging companies overcome technical barriers to commercialization. In this study, NREL has evaluated the efficiency and energy saving potential of a novel motor technology designed by ZEUS Motor Inc. located in Wheat Ridge, Colorado. The motor expands on permanent magnet AC motor (PMAC) design to create a new "radial flux, surface PMAC", or RF-sPMAC motor that is expected to outperform other novel motor technologies on the market. Here, the motor showed considerable energy benefits over typical induction motors. The motor benefits from a tightly-packed magnetic steel and copper stator that allows the motor size to be reduced to a thin disc with an internal cavity 1/30th the size of a traditional induction motor. The housing is also aluminum which is magnetically benign. This eliminates the need for external cooling (up to 25 HP), in addition to reducing power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relaxed tarantula skeletal muscle has two ATP energy-saving mechanisms

Myosin molecules in the relaxed thick filaments of striated muscle have a helical arrangement in which the heads of each molecule interact with each other, forming the interacting-heads motif (IHM). In relaxed mammalian skeletal muscle, this helical ordering occurs only at temperatures >20°C and is disrupted when temperature is decreased. Recent x-ray diffraction studies of live tarantula skeletal muscle have suggested that the two myosin heads of the IHM (blocked heads [BHs] and free heads [FHs]) have very different roles and dynamics during contraction. Here, we explore temperature-induced changes in the BHs and FHs in relaxed tarantula skeletal muscle. We find a change with decreasing temperature that is similar to that in mammals, while increasing temperature induces a different behavior in the heads. At 22.5°C, the BHs and FHs containing ADP.Pi are fully helically organized, but they become progressively disordered as temperature is lowered or raised. Our interpretation suggests that at low temperature, while the BHs remain ordered the FHs become disordered due to transition of the heads to a straight conformation containing Mg.ATP. Above 27.5°C, the nucleotide remains as ADP.Pi, but while BHs remain ordered, half of the FHs become progressively disordered, released semipermanently at a midway distance to the thin filaments while the remaining FHs are docked as swaying heads. We propose a thermosensing mechanism for tarantula skeletal muscle to explain these changes. Our results suggest that tarantula skeletal muscle thick filaments, in addition to having a superrelaxation–based ATP energy-saving mechanism in the range of 8.5–40°C, also exhibit energy saving at lower temperatures (<22.5°C), similar to the proposed refractory state in mammals.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of the Unsteady Wakes of Heavy Trucks in Platoon Formation and Their Potential Influence on Energy Savings

The authors present transient wind velocity measurements from two successive, well-documented truck platooning track-test campaigns to assess the wake-shedding behavior experienced by trucks in various platoon formations. Utilizing advanced analytics of data from fast-response (100-200-Hz) multi-hole pressure probes, this analysis examines aerodynamic flow features and their relationship to energy savings during close-following platoon formations. Applying Spectral analysis to the wind velocity signals, we identify the frequency content and vortex-shedding behavior from a forward truck trailer, which dominates the flow field encountered by the downstream trucks. The changes in dominant wake-shedding frequencies correlate with changes to the lead and follower truck fuel savings at short separation distances. All followers experience a reduction in wake-shedding frequency at following distances less than 20 m—the same zone where lead trucks experience fuel savings/drag reductions and where followers experience a reduction in platooning benefits. The dominant vortex-shedding frequency decreased by upwards of 35% in this region. Additionally, the third truck in a platoon is shown to experience a lower wake-shedding frequency than the second vehicle in either a two- or three-truck platoon. The correlation of changes in the vortex-shedding frequency to trends in drag reduction, and the associated energy savings, suggest that these phenomena may be related and may provide an opportunity for improving the efficiency potential of truck platooning.

47 OTHER INSTRUMENTATION↗

Optimization and Evaluation of Energy Savings for Connected and Autonomous Off-Road Vehicles

Off-road vehicles, such as wheel loaders, excavators, and harvesters, are extensively utilized across a wide range of industries, including construction, agriculture, and mining. These machines have become indispensable in supporting the day-to-day operational needs of a nation, playing a critical role in various sectors' infrastructure and productivity. However, despite their utility, off-road vehicles are significant consumers of fossil fuels, resulting in substantial emissions that contribute to environmental degradation. This highlights the pressing need for research and technological advancements aimed at improving their energy efficiency and reducing their carbon footprint. There are, however, two primary challenges that must be addressed to achieve these goals. First, off-road vehicles typically perform both driving and working tasks simultaneously, which introduces a high level of complexity into their overall dynamic systems. Analysis the interactions between these functions is challenging. Second, research into off-road vehicles is inherently interdisciplinary, demanding expertise across several domains such as fluid power systems, vehicle dynamics, control theory, optimization techniques, and real-world implementation. Recognizing these challenges, we proposed the project titled "Optimization and Evaluation of Energy Savings for Connected and Autonomous Off-Road Vehicles" as a comprehensive solution to enhance fuel efficiency while simultaneously improving productivity. This project specifically focuses on autonomous off-road vehicles, with particular attention to wheel loaders, and seeks to develop novel methods to optimize energy consumption without sacrificing operational performance. The project integrates real-time control algorithms, vehicle dynamics modeling, and co-optimization of powertrain system and vehicle system to achieve these goals. Our optimization strategy dynamically co-optimizes critical parameters at both the powertrain and vehicle levels, including vehicle speed, working tool movements, powertrain dynamics, and engine operations in real-time. To streamline this optimization process, we developed a vehicle model that captures the key dynamics while significantly enhancing computational efficiency. This allows the system to intelligently minimize fuel consumption, all while maintaining or even improving productivity through real-time calculations during various off-road operations. To validate the effectiveness of this energy optimization method, we introduced a state-of-the-art Hardware-in-the-Loop (HIL) testbed. This reconfigurable testbed seamlessly integrates the actual engine with virtual models of the wheel loader's subsystems, allowing for accurate emulation of real-world operational loads and environments. By simulating these conditions, the HIL testbed enables us to evaluate the wheel loader’s performance under diverse working scenarios, ensuring the developed solution is applicable in real-world operations. This testbed proved to be instrumental in validating the optimization algorithms and demonstrating the system's practical effectiveness. During the evaluation and testing phase, we employed the HIL testbed to rigorously assess the energy savings and productivity improvements generated by the optimized system. The results were highly encouraging, revealing that the automated wheel loader achieved over 30% fuel savings compared to traditional, human-operated cycles, with comparable or even enhanced levels of productivity. The insights gained from this HIL-based testing provided critical validation of our approach and highlighted the potential for deploying these optimized autonomous technologies in real-world off-road vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Study of Energy Saving Analysis for Different Industries

This study analyzes the energy consumption and saving performance in the industries in the U.S.A. All energy assessments implemented were for facilities whose annual energy consumptions were less than 9,000,000 kWh (small- and medium-sized industries) that belong to the manufacturing industries with Standard Industrial Classification (SIC) codes ranging from 2000 to 3999 in addition to SIC codes starting with 49. In this study, assessments are classified based on the SIC codes with recommendations analysis for each classification to get a better idea of what recommendations were suggested in each major industrial sector, knowing that 68 assessments were made, and their SIC ranged from 14 to 49. In addition, this study could be considered as a guide for energy engineers and other personnel involved in the energy assessment process. The information investigated can give a better prediction for composing better energy-demanding industries and minimizing energy consumption. More than 61 energy assessments were conducted for manufacturing facilities and analyzing the data gathered and processed. Through the research, the Fabricated Metal industry achieved the highest average kWh savings and cost savings within the industries studied in this study. According to the average gigajoule (GJ) savings, the fabricated metal industry ranked second within the studied industries. Conversely, Food and Kindred Products achieved the highest GJ energy savings within the studied industries. Overall, lighting, motors, compressors, and heating, ventilation, and air conditioning (HVAC) were the most contributing industries in a total of 547 recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Facility Energy Saving and Securing Technology Using Multi-Source Data (FEST) (Final Report)

Facility Energy Saving and Securing Technology (FEST) project focuses on developing algorithmic tools and techniques for analyzing cyber-physical security of DoD’s military site facilities, and optimal scheduling, operation and planning of their Distributed Energy Resources (DER). The project is led by LLNL with the team including University of Michigan-Dearborn and XENDEE. The military site partner providing the energy metering data is White Sands Missile Range (WSMR). This report summarizes the work performed during the project and future directions for follow-on research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wireless Sensors for Lighting Energy Savings

This document summarizes the energy and cost-savings benefits of wireless lighting sensors, provides an overview of where and how they can be used in buildings, and recommends best practices for different room types.

lighting, wireless, occupancy sensors, lighting co↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal Energy Savings Performance Contracts Frequently Asked Questions on the Scope of 42 U.S.C. § 8287 et. seq.

The U.S. Department of Energy's Federal Energy Management Program (FEMP) is issuing this document to provide clarifications and guidance on issues commonly raised regarding the scope of 42 U.S.C. § 8287 et seq. This document is intended to supplement FEMP's extensive collection of materials that are available to assist federal agencies execute successful energy savings performance contracting (ESPC) projects.

42 U.S.C. § 8287 et. seq.↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Printable, emissivity-adaptive and albedo-optimized covering for year-round energy saving

Radiative cooling uses high-emissivity materials to passively cool the surface of outdoor objects, such as building roofs on hot days. The issue of overcooling with this technology on cold days can be addressed by structures with thermal emissivity that is adaptive to temperature. Despite recent advances in temperature-adaptive structures, great challenges remain in their fabrication feasibility and unoptimized solar heating that may override the radiative cooling benefit. Here, in this work, we develop a printable, emissivity-adaptive and albedo-optimized covering (PEAC) based on recyclable materials with roll-to-roll fabrication. A PEAC automatically switches its sky-window emissivity from 0.25 to 0.85 when the surface temperature exceeds a pre-set transition temperature, delivering an albedo optimized for maximal year-round energy saving or thermal comfort in a given climate.

36 MATERIALS SCIENCE↗

Corroborative Evaluation of the Real-World Energy Saving Potentials of InfoRich Eco-Autonomous Driving (iREAD) System

There has been an increasing interest in exploring the potential to reduce energy consumption of future connected and automated vehicles. People have extensively studied various eco-driving implementations that leverage preview information provided by on-board sensors and connectivity, as well as the control authority enabled by automation. Quantitative real-world evaluation of eco-driving benefits is a challenging task. The standard regulatory driving cycles used for measuring exhaust emissions and fuel economy are not truly representative of real-world driving, nor for capturing how connectivity and automation might influence driving trajectories. To adequately consider real-world driving behavior and potential “off-cycle” impacts, this paper presents four collaborative evaluation methods: large-scale simulation, in-depth simulation, vehicle-in-the-loop testing, and vehicle road testing. These four approaches, spanning simulation and testing aspects, evaluate real-world fuel economy benefits with different ranges and resolutions. The large-scale simulations leverage an extensive real-world driving database to assess overall eco-driving benefits across a range of road network and driving scenarios. The real-world driving data are further leveraged to generate representative driving routes for deeper evaluation. Based on the representative routes, in-depth simulation relying on high-fidelity models investigates how different traffic scenarios can impact the eco-driving performance. The vehicle-in-the-loop setup reinforces the in-depth simulations by conducting tests with an actual vehicle operated on a chassis dynamometer; the measured energy savings were indeed found to agree with the in-depth simulation savings estimates. Finally, limited but representative road testing with the fully integrated vehicle will be conducted to demonstrate the eco-driving capability and conclude the overall evaluation regimen.

ARPA-E↗

User Objectives and Design Approaches for Microgrids: Options for Delivering Reliability and Resilience, Clean Energy, Energy Savings, and Other Priorities

In fall 2019, the National Association of Regulatory Utility Commissioners (NARUC) and the National Association of State Energy Officials (NASEO) initiated a joint Microgrids State Working Group (MSWG), funded by the U.S. Department of Energy (DOE) Office of Electricity (OE). The MSWG aimed to bring together NARUC and NASEO members to explore the capabilities, costs, and benefits of microgrids; discuss barriers to microgrid development; and develop strategies to plan, finance, and deploy microgrids to improve resilience. Based on member input, the MSWG developed two companion briefing papers to answer key questions about microgrids: (1) User Objectives and Design Approaches for Microgrids: Options for Delivering Reliability and Resilience, Clean Energy, Energy Savings, and Other Priorities and (2) Private Sector, State, and Federal Funding and Financing Options to Enable Resilient, Affordable, and Clean Microgrids. Read together, these resources provide readers with an understanding of both why and how customers—whether an investor-owned, cooperative, or municipal utility; federal, state, or local government entity; individual or group of residential, commercial, and/or industrial customers; or other organization—select, design, and pay for microgrid projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Lateral Alignment on the Energy Savings of a Truck Platoon

A truck platooning system was tested using two heavy-duty tractor-trailer trucks on a closed test track to investigate the sensitivity of intentional lateral offsets over a range of intervehicle spacings. The fuel consumption for both trucks in the platoon was measured using the SAE J1321 gravimetric procedure while travelling at 65 mph and loaded to a gross weight of 65,000 lb. In addition, the SAE J1939 instantaneous fuel rate was calibrated against the gravimetric measurements and used as proxy for additional analyses. The testing campaign demonstrated the effects of intervehicle gaps, following-vehicle longitudinal control, and manual lateral control. The new results are compared to previous truck-platooning studies to reinforce the value of the new information and demonstrate similarity to past trends. Fuel savings for the following vehicle was observed to exceed 10% at closer following distances. The results showed that energy savings generally increased in a non-linear fashion as the gap was reduced. The impact of different following-truck lateral offsets had a measurable impact, with up to 4% reduction in total fuel-savings (relative to an isolated vehicle condition) observed for offsets up to 1.3 m. The fuel-consumption savings on the straight segments of the track exceeded those on the curved segments by upwards of 6% and highlight some potential differences expected between close-track testing and on-highway use.

adaptive cruise control↗