Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Enclosures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

Lithium ion battery

A multi-core lithium ion battery includes a sealed enclosure and a support member disposed within the sealed enclosure. The sealed enclosure may be fabricated with a clamshell configuration. The sealed enclosure may further include at least two support members housed within individual compartments, separated by shared wall(s). The support member(s) includes a plurality of cavities and a plurality of lithium ion core members which are disposed within the plurality of cavities. The battery may further include a plurality of cavity liners, each of which is positioned between a corresponding one of the lithium ion core members and a surface of a corresponding one of the cavities. The hermetically sealed enclosure may be formed using a clamshell configuration. Structures may be included in proximity to or in contact with the lithium ion core members to control gas/fluid flow therefrom.

25 ENERGY STORAGE↗

Reference electrode for electrochemical measurements at high temperatures

A reference electrode which is stable over a wide range of temperatures, pressures and chemical conditions is provided. The subject reference electrode according to the present invention comprises a tubular enclosure composed of quartz having a distal, closed end and a proximal, open end. An insulating ceramic rod is seemingly connected to the opening in the closed distal end of the enclosure to form micro-cracks between the ceramic rod and the quartz enclosure (called a cracked junction, CJ). The CJ gives a very tortuous path for ion conduction from inside the reference electrode (RE) to a working electrode (WE). Inside the tubular enclosure is an electrical lead (e.g., a silver wire) disposed in an electrolyte comprising a mixture of alkaline metal salts (e.g., AgCl and KCl), extending from the electrolyte upward through a sealing means at the proximal end of the quartz enclosure.

Gervasio, Dominic Francis↗

Humidity-Dependent Electrostatic Charge Decay on Dielectric Surface in Enclosed Volumes

Electrostatic surface charge decay is investigated to determine loss mechanisms, the effect of humidity, enclosure size, and material. This work focuses on charging dielectric and metal surfaces close to the electrical breakdown threshold in atmospheric air under humid and dry conditions. After initial charging to a maximum potential of roughly 30 kV, the associated surface charge is allowed to decay because of recombining with ions from the natural background, resulting in decay times ranging from minutes to hours to days. Spheres with a radius of 50 mm consisting of varying materials (PTFE and metal as referenced later) are charged and tested at relative humidity levels, RH, of 10%, 35%, and 64%. It was found that the ion-ion pair production rate and the enclosure size affected the measured charge decay rate. The impact of air convection on charge decay in the open air (no enclosure) is discussed. The humidity increased the rate of charge decay on the metal and dielectric spheres. For example, in the first 25 minutes after charging, the total charge on the PTFE sphere decreased to 66%or 50% from its initial value in the 10% and 35% RH tests, respectively. An equivalent generation rate is found for the ions in the enclosure, with 10 and 24 ion pairs cm −3 s −1 being generated at a 5% and 49% relative humidity, respectively.

42 ENGINEERING↗

Residual Dose and Environmental Monitoring for the Fermilab Main Injector Tunnel Using the Data Acquisition Logging Engine (Dale)

The Recycler and the Main Injector are part of the Fermilab Accelerator complex used to deliver proton beam to the different experiments. It is very important to control and minimize losses in both machines during operation, to reduce personnel dose from residual activation and to preserve component lifetime. To minimize losses, we need to identify the loss points and adjust the components accordingly. The Data Acquisition Loss Engine (DALE) platform has been developed within the Main Injector department and upgraded throughout the years. DALE is used to survey the entire enclosure for residual dose rates and environmental readings when unrestricted access to the enclosure is possible. Currently DALE has two radiation meters, which are aligned along each machine, so loss points can be identified for both at the same time. DALE attaches to the enclosure carts and is continuously in motion monitoring dose rates and other environmental readings. In this paper we will describe how DALE is used to provide radiation maps of the residual dose rates in the enclosure. We will also compare the loss points with the Beam Loss monitor data.

43 PARTICLE ACCELERATORS↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

Ionizing-radiation beam monitoring system

Embodiments are directed generally to an ionizing-radiation beam monitoring system that includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam. Embodiments further include at least one scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and at least one ultraviolet illumination source within the enclosure structure and facing the scintillator. At least one pixelated imaging system within the enclosure structure is located out of an incident ionizing-radiation beam path and includes at least one pixelated photosensor device optically coupled to an imaging lens.

Friedman, Peter S.↗

Comparison of Thermal Management Approaches for Integrated Traction Drives in Electric Vehicles

The continuous push to increase power densities of electric vehicle (EV) traction drive systems necessitates combining electric motor and power electronics into one unit. A single, compact traction drive unit with fewer interconnecting components also facilitates fast, automated assembly of electric vehicles, driving production costs down and enabling wider adoption of EVs. There are a number of challenges associated with the integration of power electronics with the electric machine, including thermal management of the combined traction drive system. However, one important benefit of integration from the thermal management system perspective is the potential for using a single fluid loop instead of two separate cooling systems for the electric machine and the power electronics/inverter. This paper reviews several integration approaches and, employing finite element analysis (FEA), compares thermal management solutions for the combined electric machine and power electronics systems. Namely, three different scenarios are modeled: (1) independent component (motor and power electronics) cooling, which is compared to the combined cooling system approach for (2) radially and (3) axially integrated power electronics modules into the motor enclosure. Temperature distributions for selected thermal loads and thermal resistances from the key heat-generating components to the cooling fluid are compared for each scenario.

47 OTHER INSTRUMENTATION↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Efficient Process for Manufacturing of Thermoplastic Composites with Tailored Properties (CRADA 511)

This is a collaborative effort between Battelle Memorial Institute as manager and operator of Pacific Northwest National Laboratory (PNNL) and ESI North America Inc. (“ESI” or “Participant”) to apply computation and data analytics to the challenge of light weighting with a focus on the battery enclosures of electric vehicles (EVs). EVs use heavy batteries to increase range and power. A complex-shaped battery enclosure is required to meet a host of challenging performance requirements. The ability to virtually develop composite parts such as battery enclosure with tailored properties to meet required performance will be highly valuable to the automotive industry. However, efficient simulation of composite-manufacturing processes remains a challenging issue since simulation involves multiscale models in space and time, highly non-linear and anisotropic behavior, strongly coupled multi-physics, and complex geometries. This work will advance the state of the art by reducing the computational burden of composite optimization by using simulation data from a limited number of configurations off-line and then developing a reduced order model (ROM) using data analytics and machine learning (ML). Develop a data driven approach to link features of the material and manufacturing processes to the mechanical properties of thermoplastic composite parts.

42 ENGINEERING↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and system for compact efficient laser architecture

A laser amplifier module having an enclosure includes an input window, a mirror optically coupled to the input window and disposed in a first plane, and a first amplifier head disposed along an optical amplification path adjacent a first end of the enclosure. The laser amplifier module also includes a second amplifier head disposed along the optical amplification path adjacent a second end of the enclosure and a cavity mirror disposed along the optical amplification path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Housing apparatus for sensitive gas sensor

A sensor housing apparatus includes a housing having an enclosure and outer assembly, at least one flow path extending through the housing, a gas sensor disposed in the enclosure and a thermal mass. The thermal mass is mounted within the enclosure in thermal communication with the gas sensor, and is configured to transfer thermal energy from the gas sensor to an ambient environment surrounding the housing and minimize temperature gradients adjacent the gas sensor.

Martin, Yves C.↗

Adsorption system

An adsorption system can be used as part of a climate control system in a vehicle or in any other space requiring heating or cooling. The adsorbent system can include an enclosure, a plurality of layers arranged in a stack inside the enclosure, and a vapor channel inside the enclosure.

Wang, Evelyn N.↗

Resource loading system and method for use in atmosphere containment scenarios

The invention provides a system for preventing fluid exchange between the interior and exterior of containment enclosures such as process-, hazard-, and research-enclosure systems generally, gloveboxes, containment systems, isolation systems, confinement systems, cleanrooms, negative air systems, and positive air system areas while simultaneously providing material transfer into and out of the enclosures. The invention also provides a method for transporting material into or out of a containment structure.

Dilday, Jr., Daniel R.↗

Ecosystem device for determining plant-microbe interactions

This disclosure provides systems, methods, and devices related to the study of ecological processes. In one aspect, a device includes a base, a substrate, and an enclosure. The substrate is in contact with a first surface of the base. The substrate and the base define a root chamber. The enclosure is in contact with a second surface of the base. The base and the enclosure define a growth chamber. The base defines a stem port connecting the root chamber and the growth chamber. The base further defines a first port in fluid communication with the root chamber and a second port in fluid communication with the root chamber. The device is operable to contain a plant, roots of the plant being in the root chamber, a stem of the plant passing through the stem port, and leaves of the plant being in the growth chamber.

Andeer, Peter↗

Evaporator stacks and electronic assemblies

Provided is an evaporator stack. The evaporator stack may be used in power-dense electronic assemblies. The evaporator stack includes a lower floor including at least one mounded portion, and an enclosure surrounding the lower floor, wherein a height of the enclosure is greater than a height of the at least one mounded portion, the at least one mounded portion extending between two walls of the enclosure.

Roan, Thomas J.↗

Vertical high-pressure rinse machine

A high-pressured rinsing system comprises a base including a liquid reservoir, a rotation motor housing including a rotation motor adapted to rotate a spray wand attached, and extending vertically upward from, the rotation motor housing and base, a linear rail support frame attached the base and including a vertical motor and associated linear rail attached thereto, a cavity mounting plate attached to the linear rail, wherein vertical movement of the linear rail causes vertical movement of the cavity mounting plate over the base; and at least one door and a plurality of side panels mounting to an enclosure support frame, wherein the enclosure support frame is mounted and secured to the linear rail support frame and base to create an enclosure around the spray wand and linear rail.

Ring, Timothy J.↗