Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical resistivity tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Deep Learning At Depth: Estimating subsurface parameters from geophysical monitoring data

Geophysical imaging techniques are a non-invasive way to image the subsurface and understand both subsurface solid (rock/soil) and fluid property distributions and their evolution in time. Inversions of the geophysical data, such as Electrical Resistance Tomography (ERT) data, are solved to estimate the subsurface property distributions, such as conductivity, and many inversion techniques smooth out sharp gradients in rock or fluid property distributions. Sharp gradients in subsurface properties tend to be present in situations with complex subsurface structures, which are common in many subsurface applications. We have successfully demonstrated that it is possible to inform, or constrain, inversions with neural networks trained on synthetic data with complex subsurface structures. Initial results suggest this process may be optimizable to yield property distributions that better represent the true property distributions than the same inversion process without the neural network constraint. Future work would optimize the neural network performance for this application and then apply the synthetic-data trained neural network to real data to understand the utility and performance of this technique for real data sets.

47 OTHER INSTRUMENTATION↗

Using Geophysical Information to Investigate Subsurface Structure within the High-Hydraulic Conductivity Analysis Zone

Within the 200 East Area of the Central Plateau and southeastward toward the Columbia River, a high-hydraulic conductivity zone (HCZ) has been interpreted to extend through the 200-PO-1 and 200-BP-5 operable units on the Hanford Site. The HCZ is a controlling hydraulic feature that impacts groundwater flow out of the 200 East Area and the fate of eastwardly migrating plumes from the 200 West Area. The lateral extent of the HCZ is highly uncertain, and despite strong evidence for the existence of the HCZ based on water-level data and contaminant plume tracking, there is still a limited understanding of how to define its boundaries. To provide additional information on the nature and extent of the HCZ, three surface geophysical methods – electrical resistivity tomography (ERT), time-domain electromagnetics (TEM), and seismic methods – were used to collect data south of 200 East. In addition, existing data from 200 East, consisting of surface seismic data, a borehole check shot survey in 699-37-47A, and borehole stratigraphic interpretations, were used to aid interpretations of newly collected seismic data south of 200 East. This work presumed that the contrast in subsurface geophysical properties would be a first-order aid identifying a transmissive zone(s) within the HCZ analysis area by imaging contrasts and/or anomalies in geophysical properties. While seismic, ERT, and TEM methods have sensitivity to overlapping physical properties (porosity, moisture content, lithology), the resolution and physics used to acquire each of these datasets are different, and therefore the information can also be different. Figure S.1 shows the locations of the geophysical data considered in this report.

58 GEOSCIENCES↗

Blue Canyon Dome: Development of a Small-Scale Testbed for Monitoring Underground Explosions

This report documents the development of the Blue Canyon Dome (BCD) testbed, including test site selection, development, instrumentation, and logistical considerations. The BCD testbed was designed for small-scale explosive tests (~5 kg TNT equivalence maximum) for the purpose of comparing diagnostic signals from different types of explosives, the assumption being that different chemical explosives would generate different signatures on geophysical and other monitoring tools. The BCD testbed is located at the Energetic Materials Research and Testing Center near Socorro, New Mexico. Instrumentation includes an electrical resistivity tomography array, geophones, distributed acoustic sensing, gas samplers, distributed temperature sensing, pressure transducers, and high-speed cameras. This SAND report is a reference for BCD testbed development that can be cited in future publications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Estimating Vadose Zone Flow Properties at the 100 K-East Soil Flushing Site Using ERT Monitoring Data: 2023 Interim Report - 100 KE Soil Property Estimation

In situ soil flushing is being using at the Hanford 100 K-East (100 KE) area to transport mobile chromium contamination in the vadose zone to the water table, where it can be collected and treat through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. In practice, it is infeasible to comprehensively monitor which regions of the vadose zone are being infiltrated through direct sampling of pore water. Consequently, there can be significant uncertainty about which regions of the subsurface have been treated, especially if hydrogeologic conditions are favorable for the development of unstable flows and preferred flow pathways through the vadose zone (Jarvis, Koestel, and Larsbo 2016). Current approaches for quantitative monitoring of soil flushing performance rely on contaminant concentration measurements collected from extractions wells. There is no quantitative information on the volume of flush water delivered to targeted regions of the vadose zone at the Hanford Site, leading to significant uncertainty regarding source term removal and long-term impacts to groundwater. If the subsurface hydrogeologic properties at the 100 KE Area were adequately known, qualitative metrics of soil flushing performance could be simulated, thereby negating expenses required to obtain quantitative performance information through borehole drilling/sampling. However, estimating in situ hydrogeologic properties has long proven elusive, due primarily to a lack of sufficient information to constrain heterogeneous property estimates to a useful degree of certainty. Estimating vadose zone hydrogeologic properties is particularly challenging due the dependence of hydraulic conductivity on saturation. This report describes progress toward a first-of-its-kind demonstration using surface time-lapse 3D electrical resistivity tomography (ERT) monitoring data to estimate the hydrogeologic properties that control flush water transport at the 100 KE soil flushing site. The ultimate objective is (1) to verify sufficient information exists in the ERT monitoring data to adequately resolve vadose zone hydraulic properties, and (2) generate a “digital twin” (i.e., a numerical simulator) that can be used to simulate the amount of flush water that has been delivered to each targeted region of the vadose zone, and thereby assess the efficacy of flush water delivery. Resulting performance estimates can be used in leu of comprehensive borehole drilling and direct sampling (or wellbore logging) that would otherwise be required to obtain the same information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Brief communication: Decadal changes in topography, surface water and subsurface structure across an Arctic coastal tundra site

Abstract. In ice-rich polygonal tundra, spatiotemporal heterogeneity in ground-ice melt reshapes topography, impacting infrastructure, water and carbon cycles. This study evaluates changes in topography and subsurface structure at a coastal Arctic site by comparing data from two surveys conducted a decade apart. Each survey includes electrical resistivity tomography, active layer thickness, photogrammetry, and topographic data. Results reveal subsidence and decrease in permafrost table elevation with varying intensity and spatial distribution across polygons, alongside diverse thermal-hydrological responses, such as thermokarst pool formation in high-centered-polygons and more even subsidence in flat-centered-polygons. The study also underscores the value and limitations of sporadic surveys.

Bachman, Jonathan A↗

Complementary Subsurface Characterization Methods to Develop a Geologic Model for the EGS Collab Experiment, Sanford Underground Research Facility

The EGS (Enhanced Geothermal Systems) Collab project was performed within the Sanford Underground Research Facility (SURF) with a goal of understanding processes and evaluation of models related to hydraulic simulation of rock at depth. The present work deals with the development of Testbed 2 where experiments were conducted at a depth of 1.25 km and were located within a well-characterized testbed in a metamorphic, amphibolite host rock. A total of eleven boreholes varying in length between 10.6 m and 81.2 m were continuously cored to develop the testbed. In addition to the continuous coring of the amphibolite host rock, geophysical instrumentation supporing electrical resisivity tomography (ERT), microearthquake (MEQ) detection, and optical fiber providing distributed temperature sensing (DTS) and distributed acoustic sensing (DAS) were installed in the monitoring boreholes, all of which produced a comprehensive complementary suite of characterization and monitoring technologies.

15 GEOTHERMAL ENERGY↗

The Thermal Plumbing System of Stromboli Volcano, Aeolian Islands (Italy) Inferred From Electrical Conductivity and Induced Polarization Tomography

Abstract We performed the first 3D island‐scale tomography of the electrical conductivity of Stromboli volcano (Aeolian Islands, Italy) using 2D acquisition lines (37.2 km) and a total of 18,880 measurements and 2,402 unique electrode locations. This 3D data set was inverted using a Gauss‐Newton algorithm, parallel‐processing on an unstructured tetrahedral mesh containing 678,420 finite‐element nodes and 3,580,145 elements to account for the topography of the volcanic island. The tomogram exhibits a conductive body (10 −2 –1.0 S m −1 ) consistent with the location of CO 2 and temperature anomalies observed at the ground surface. It corresponds to the hydrothermal system with high electrical conductivity associated with alteration. In order to confirm this interpretation, a 2.5D large‐scale induced polarization tomography was performed crossing the volcano. The joint interpretation of the conductivity and normalized chargeability is done with a petrophysical model previously tested and verified at both shield‐ and strato‐volcanoes. This model implies that alteration (through the effect of the cation exchange capacity associated with clay minerals and zeolites) plays a strong role in both controlling the electrical conductivity and normalized chargeability at Stromboli volcano. A temperature tomogram, derived from the geoelectrical measurements, is consistent with surface temperature anomalies and the Very Long Period (VLP) seismicity related to the mild‐explosive activity. This survey displays at 600 m a.s.l. a lateral shift in the highest temperature location, also corresponding to the source of VLP seismicity. Structural boundaries have a major role in the hottest hydrothermal fluids rising below the active crater terrace of Stromboli volcano.

58 GEOSCIENCES↗

Electrical Conductivity of Clayey Rocks and Soils: A Non-Linear Model

It is well-accepted that Archie's law is only applicable to “clean” rocks and soils but fails in “dirty” ones where clay minerals possess an additional component of surface conductivity. Although several models, for example, Waxman-Smits model, were presented to account for this phenomenon, surface conductivity is always inappropriately treated as constant, which actually only holds at high salinities. The essential non-linear characteristic differing over fluid salinities has not been physically or mathematically explained well in those models. Here, we scrutinize the conduction mechanism of clayey rocks and soils and ascribe this non-linear feature to (a) variation of the electrical double layer and (b) the intrinsic clay-and-water conduction pattern. With effective medium theory, we develop an easy-to-use non-linear model that both reflects electrochemical theories and explains the measurement data well. Our model can be used to produce more accurate results for laboratory- and field-scale petrophysical parameter evaluations than the previous models.

58 GEOSCIENCES↗

New developments in structure-property and amorphous materials research at the upgraded 16-BM-B Paris-Edinburgh press station at HPCAT

Beamline 16-BM-B of the High-Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source (APS) provides a Paris-Edinburgh press program to probe the structure and properties of crystalline and amorphous materials up to 12 GPa at room temperature or 7 GPa at 2000°C. During the recent APS upgrade, 16-BM-B undertook major improvements to its instrumentation and measurement techniques. The upgrade includes the addition of a 1.2 m horizontal “condenser” mirror and a new variable-sized collimation system, the combination of which decreases the acquisition time for energy dispersive X-ray diffraction measurements by a factor of 10 when compared to pre-upgrade measurements. The addition of a new Ge energy-sensitive detector and DANTE (XGLab) digital pulse processor allows for processing the increased diffraction counts with minimal deadtime. In addition to upgraded beamline components, new techniques are being developed for eventual release to the user community, including electrical resistivity and tomography measurements.

APS upgrade↗

Electrical Imaging for Hydrogeology

This book chapter will contribute to a volume on geophysics being developed for the Groundwater Project (https://gw-project.org). The Groundwater Project is committed to contribute to advancement in education by creating and making available online free high-quality groundwater educational material for all. The Groundwater Project is led by Dr. John Cherry, recipient of the 2020 Stockholm Water Prize, and managed by a 11-member international Steering Committee and a larger and globally diverse Advisory Committee. Details on the groundwater project and book volumes may be found at https://gw-project.org/gw-project-background-information.pdf .

groudnwater, electrical resistivity imaging, resis↗

Low-Temperature Annealing of Nanoscale Defects in Polycrystalline Graphite

Polycrystalline graphite contains multi-scale defects, which are difficult to anneal thermally because of the extremely high temperatures involved in the manufacturing process. In this study, we demonstrate annealing of nuclear graphite NBG-18 at temperatures below 28 °C, exploiting the electron wind force, a non-thermal stimulus. High current density pulses were passed through the specimens with a very low-duty cycle so that the electron momentum could mobilize the defects without heating the specimen. The effectiveness of this technique is presented with a significant decrease in electrical resistivity, defect counts from X-ray computed tomography, Raman spectroscopy, and nanoindentation-based mechanical characterization. Such multi-modal evidence highlights the feasibility of nanoscale defect control at temperatures about two orders of magnitude below the graphitization temperature.

Liu, Gongyuan↗

Microstructure, electrical resistivity, and tensile properties of neutron-irradiated Cu–Cr–Nb–Zr

High strength, high conductivity copper alloys that can resist creep at high temperatures are one of the primary candidates for efficient heat exchangers in fusion reactors. Cu–Cr–Nb–Zr (CCNZ) alloys, which were designed to improve the strength and creep life of ITER Cu–Cr–Zr (CCZ) reference alloys, have been found to have comparable electrical conductivity and tensile properties to CCZ alloys. The measured creep rupture times for these improved alloys is about ten times higher than the ITER reference alloys at 90–125 MPa at 500 °C. However, the effects of neutron irradiation on these alloys, and the ensuing material properties, have not been studied; thus, their utility in a fusion reactor environment is not well understood. This study characterizes the room temperature mechanical and electrical properties of a neutron-irradiated CCNZ alloy and compares them to a neutron-irradiated ITER reference heat sink CCZ alloy. Tensile specimens were neutron irradiated in the High Flux Isotope Reactor (HFIR) to 5 dpa between 250 °C and 325 °C. Post-irradiation characterization included electrical resistivity measurements, hardness, and tensile tests. Microstructural evaluation used scanning electron microscopy, energy dispersive x-ray spectroscopy, and atom probe tomography to characterize the irradiation-produced changes in the microstructure and investigate the mechanistic processes leading to post-irradiation properties. Transmutation calculations were validated with composition measurements from atom probe data and used to calculate contributions to the increased electrical resistivity measured after irradiation. Comparisons with CCZ alloys in the same irradiation heat found that the post-irradiated CCNZ and CCZ alloys had comparable electrical resistivity. Although CCNZ alloys suffered more irradiation hardening than CCZ, the overall tensile behavior deviated very little from non-irradiated values in the temperature range studied.

36 MATERIALS SCIENCE↗

Grain Boundary Phases in NbFeSb Half‐Heusler Alloys: A New Avenue to Tune Transport Properties of Thermoelectric Materials

Abstract Many thermoelectric materials benefit from complex microstructures. Grain boundaries (GBs) in nanocrystalline thermoelectrics cause desirable reduction in the thermal conductivity by scattering phonons, but often lead to unwanted loss in the electrical conductivity by scattering charge carriers. Therefore, modifying GBs to suppress their electrical resistivity plays a pivotal role in the enhancement of thermoelectric performance, zT . In this work, different characteristics of GB phases in Ti‐doped NbFeSb half‐Heusler compounds are revealed using a combination of scanning transmission electron microscopy and atom probe tomography. The GB phases adopt a hexagonal close‐packed lattice, which is structurally distinct from the half‐Heusler grains. Enrichment of Fe is found at GBs in Nb 0.95 Ti 0.05 FeSb, but accumulation of Ti dopants at GBs in Nb 0.80 Ti 0.20 FeSb, correlating to the bad and good electrical conductivity of the respective GBs. Such resistive to conductive GB phase transition opens up new design space to decouple the intertwined electronic and phononic transport in thermoelectric materials.

36 MATERIALS SCIENCE↗

High Performance Circuit Pastes for Solid Oxide Fuel Cell Applications: Final Technical Report

Using a combination of in-plane electrical conductivity measurements, electrical contact resistance measurements, tensile fracture tests, double shear lap fracture tests, rapid thermal cycling adhesion tests, in situ wetting angle measurements, 3D X-ray tomography, reduction-oxidation (RedOx) cycling, scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDAX), Density Functional Theory (DFT) modeling, Molecular Dynamics (MD) modeling, and Phase Field modeling, this project determined that a new brazing technique developed by the PIs (specifically the use of nickel particles to direct the wetting and spreading of molten silver) could be used to produce well-adhered, >97% dense, electrically-conductive circuits, current collectors, and/or electrical contacts on a variety of ceramic and ceramic-coated substrates (specifically lanthanum strontium manganite, yttria stabilized zirconia, sapphire, Cr2O3-passivated stainless steel, and Al2O3-passivated stainless steel). Compared to other silver-based alternatives, Ag:Ni led to less manufacturing defects and was more tolerant of the extreme environments (isothermal high-temperature aging) and occasional abuse (rapid thermal cycling and RedOx cycling) encountered during Solid Oxide Fuel Cell and/or Solid Oxide Electrolysis Cell operation. Further, in some situations (such as when to produce Ag:Ni electrical contacts to Al2O3-protected stainless steel) the Ni particles also improved operation by acting as chemical getters that removed electrically-insulating, surface-segregating substrate impurities (i.e. by lowering the contact resistance with the underlying substrate).

36 MATERIALS SCIENCE↗

Feasibility Assessment of Using Electrical Impedance Tomography for Damage Localization in Graphite Microreactor Components

Microreactors have great potential to decrease capital costs and construction timelines, reducing the barriers to implementing advanced nuclear reactor technologies. However, the lower power output of these microreactors introduces economic challenges if the operation and maintenance costs cannot be reduced sufficiently. Many microreactor concepts use graphite materials for in-core moderator and structural purposes, which will require periodic inspection or, ideally, in situ structural health monitoring. This work describes an initial evaluation of the feasibility of leveraging graphite’s semiconducting properties to perform electrical impedance tomography (EIT) for defect localization. First, a study was performed to identify the best methods for bonding electrical contacts to minimize the effects of contact resistance that interfere with impedance measurements of the graphite. After determining the best bonding approach, electrodes were attached to multiple graphite components with varying geometries (e.g., simple block and more representative microreactor hexagonal block). In parallel, finite element analysis approaches were developed and implemented to analyze the impact of defects and contact resistances and to inform an iterative inverse model for reconstructing the conductivity distribution. The results of this study show that defect localization in graphite components is possible using EIT if a sufficient number of electrodes (to improve spatial resolution) can be bonded using a technique with very low contact resistance and those contact resistances remain stable during reactor operation. If the reactor core and vessel design do not allow electrodes to be bonded during reactor operation, then it may be possible to detach/reattach electrodes between reactor operation and outages if a suitable mechanical connection that offers repeatable contact resistance can be identified. Alternatively, future work could focus on identifying contacts that can survive the harsh reactor operating environment so that contacts do not need to be removed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantitative phenotyping of crop roots with spectral electrical impedance tomography: a rhizotron study with optimized measurement design

Background: Root systems are key contributors to plant health, resilience, and, ultimately, yield of agricultural crops. To optimize plant performance, phenotyping trials are conducted to breed plants with diverse root traits. However, traditional analysis methods are often labour-intensive and invasive to the root system, therefore limiting high-throughput phenotyping. Spectral electrical impedance tomography (sEIT) could help as a non-invasive and cost-efficient alternative to optical root analysis, potentially providing 2D or 3D spatio-temporal information on root development and activity. Although impedance measurements have been shown to be sensitive to root biomass, nutrient status, and diurnal activity, only few attempts have been made to employ tomographic algorithms to recover spatially resolved information on root systems. In this study, we aim to establish relationships between tomographic electrical polarization signatures and root traits of different fine root systems (maize, pinto bean, black bean, and soy bean) under hydroponic conditions. Results: Our results show that, with the use of an optimized data acquisition scheme, sEIT is capable of providing spatially resolved information on root biomass and root surface area for all investigated root systems. We found strong correlations between the total polarization strength and the root biomass (R 2 = 0.82) and root surface area (R 2 = 0.8). Our findings suggest that the captured polarization signature is dominated by cell-scale polarization processes. Additionally, we demonstrate that the resolution characteristics of the measurement scheme can have a significant impact on the tomographic reconstruction of root traits. Conclusion: Our findings showcase that sEIT is a promising tool for the tomographic reconstruction of root traits in high-throughput root phenotyping trials and should be evaluated as a substitute for traditional, often time-consuming, root characterization methods.

59 BASIC BIOLOGICAL SCIENCES↗

Unprecedented electrical performance of friction-extruded copper-graphene composites

Copper-graphene composites show remarkable electrical performance surpassing traditional copper conductors albeit at a micron scale; there are several challenges in demonstrating similar performance at the bulk scale. In this study, we used shear extrusion to synthesize macro-scale copper-graphene composites with a simultaneously lower temperature coefficient of resistance (TCR) and improved electrical conductivity over copper-only samples. We showed that the addition of 18 ppm of graphene decreased the TCR of C11000 alloy by nearly 11%. A suite of characterization tools involving scanning and transmission electron microscopy along with atom probe tomography were used to characterize the grain size, crystallographic orientation, structure, and composition of copper grains and graphene additives in the feedstock and processed samples. We posit that the shear extrusion process may have transformed some of the feedstock graphene additives into higher defect-density agglomerates while retaining the structure of others as mono-to-trilete flakes with lower defect density. The combination of these additives with heterogeneous structures may have been responsible for the simultaneous decrease in TCR and enhanced electrical conductivity of the copper-graphene ShAPE composites.

36 MATERIALS SCIENCE↗

High-Temperature Mechanical Tensile Testing of Unidirectional Sic/Sic Composites Using A Versatile Lamp Furnace

Silicon carbide (SiC) based ceramic matrix composites (CMCs) are of interest for high-temperature structural applications, including use in turbine engine components. To understand damage mechanisms and predict durability of these systems, in-depth knowledge of their behavior at ambient and high temperatures is necessary. A method for high temperature testing of SiC/SiC minicomposite specimens up to 1500oC in both tensile fast fracture and creep conditions to investigate their thermomechanical behavior will be presented. This method utilizes a novel radiation heat furnace, equipped with infrared lamps with ellipsoidal reflectors, to heat the specimen at the furnace center in user-defined atmospheres. The housing structure of the lamps allows for observation of the specimen during testing using optical methods and for conducting other experimental studies. The goal is to employ nondestructive health monitoring techniques in-situ, including acoustic emission (AE), electrical resistance (ER), and digital image correlation (DIC) to evaluate damage initiation and evolution in the minicomposite specimens during tensile testing. Results from mechanical testing and nondestructive techniques will be presented. Electron microscopy and X-ray micro-computed tomography were used to further characterize specimen damage after testing.

Aeronautics↗