Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical breakdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Time Delay from Corona to Breakdown

This report describes measurements of the time delay between the onset of corona and complete electrical breakdown between a point and a plane in dry air near atmospheric pressure as a function of the distance between the point and the plane. The large variation in these time delays is representative of the stochastic nature of electrical breakdown and the many possible phenomena that occur between the initiation and completion of electrical breakdown, including initiation without complete electrical breakdown. The purpose of this work is to provide data which will be accurately modeled when a model contains the appropriate mechanisms with the proper priorities to describe this fundamental electrical breakdown configuration. The acquisition of these measurements completes a level three milestone for the WSEAT program which sponsors this research. Also included in this report is a description of our plans to “automate” the experimental procedure, protect the high sensitivity fast-gated camera, and add diagnostics and new experimental techniques to the test facility. This will provide measurements of the time delay distributions with improved statistics and additional experimental information about the processes that occur during electrical breakdown.

42 ENGINEERING↗

Nonequilibrium dynamics of laser-generated plasma channels

A time-dependent nonequilibrium kinetics model based upon the time-dependent electron Boltzmann equation coupled with an extensive air chemistry model accounting for gas heating and vibrational kinetics is developed. The model is applied to the temporal evolution of femtosecond laser-generated air plasma channels at atmospheric pressure in an external electric field. The plasma channel dynamics depend upon the initial free electron density, the initial electron energy of the plasma, and upon the externally applied electric field strength. The model predicts an electric breakdown field strength of 5-10 kV/cm with a delay time of hundreds of nanoseconds when the electron density drops to the optimum value of {approx}10{sup 12}-10{sup 13} cm{sup -3}. The experimentally observed breakdown field is {approx}5.7 kV/cm with a statistical breakdown delay time of {approx}200 ns. The reduction in the breakdown field strength in natural air from {approx}30 to 5 kV/cm is attributed to a combination of processes such as enhanced ionization due to relaxation of the initial electron energy distribution function toward a Maxwellian distribution, strong electron detachment, and gas heating. The calculated electron density decay of the laser-generated plasma channel in both pure nitrogen and dry air is in good agreement with the NRL experiments. The derived rate constant for recombination in dry air is b{sub B}{sup air}=3.9x10{sup -8} cm{sup 3} s{sup -1} and in pure nitrogen it is b{sub B}{sup N{sub 2}}=4.4x10{sup -8} cm{sup 3} s{sup -1}. The attachment rate coefficient in dry air is {eta}{sub B}{sup air}=7.5x10{sup 6} s{sup -1}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VERY LOW FREQUENCY BREAKDOWN PROPERTIES OF ELECTRICAL INSULATION MATERIALS AT CRYOGENIC TEMPERATURES

For long cables or equipment with large capacitance it is not always possible to conduct high voltage withstand at tests at 60 Hz due to limitations in charging currents of the power supply. Very low frequency (typically at a frequency of 0.1 Hz) has been used for conventional cables as a way of getting around the charging current limitation. For superconducting grid applications the same issues apply. However there is very little data at cryogenic temperatures on how materials perform at low frequency compared to 60 Hz and whether higher voltages should be applied when performing a high voltage acceptability test. Various materials including G10 (fiberglass reinforced plastic or FRP), Cryoflex™ (a tape insulation used in some high temperature superconducting cables), kapton (commonly used polyimide), polycarbonate, and polyetherimide, and in liquid nitrogen alone have been tested using a step method for frequencies of 60 Hz, 0.1 Hz, and dc. The dwell time at each step was chosen so that the aging factor would be the same in both the 60 Hz and 0.1 Hz tests. The data indicated that, while there is a small frequency dependence for liquid nitrogen, there are significant differences for the solid materials studied. Breakdown data for these materials and for model cables will be shown and discussed.

cryogenic dielectric↗

Electron generation and multiplication at the initial stage of nanosecond breakdown in water

Electrical breakdown of liquid dielectrics under nanosecond pulsed high voltage has been investigated extensively in the last decade. Prior studies have focused on either experimental characterization of the breakdown process and discharge plasma or formulation/verification of the electrostrictive cavitation mechanism of the breakdown initiation. There remain knowledge gaps toward a clear physical picture of how the first plasma is generated in a region saturated by nanoscale cavities created by electrostrictive forces in inhomogeneous fields at the nanosecond timescale. Initial plasma results from the multiplication of primary electrons that gain energy collisionlessly in the cavities to cause collisional ionization of water molecules on the cavity walls. This paper quantitatively discusses the possible sources of primary electrons that seed the plasma discharge. Electron detachment from hydroxide is shown to be the most probable and sustainable electron source. Using numerical modeling, this study demonstrates the plausibility of an electron multiplication mechanism involving two neighboring cavities. The drift of hydrated electrons from one cavity to the next is the rate-limiting step and sets the minimum electric field requirement. Furthermore, this work will inform subsequent experimental studies and have implications in various applications such as plasma sources in biomedical applications, cavitation study, and insulation of pulsed power equipment.

42 ENGINEERING↗

Evaluation of Magnetic Insulation in SF6 Filled Regions

The use of magnetic fields perpendicular to quasistatic electric fields to deter electrical breakdown in vacuum, referred to as magnetic insulation, is well understood and used in numerous applications. Here we define quasi-static as applied high-voltage pulse widths much longer than the transit time of light across the electrode gap. For this report we extend the concept of magnetic insulation to include the inhibition of electrical breakdown in gases. Ionization and electrical breakdown of gases in crossed electric and magnetic fields is only a moderately explored research area. For sufficiently large magnetic fields an electron does not gain sufficient energy over a single cycloidal path to ionize the gas molecules. However, it may be possible for the electron to gain sufficient energy for ionization over a number of collisions. To study breakdown in a gas, the collective behavior of an avalanche of electrons in the formation of a streamer in the gas is required. Effective reduced electric field (EREF) theory, which considers the bulk properties of an electron avalanche, has been successful at describing the influence of a crossed magnetic field on the electric field required for breakdown in gases; however, available data to verify the theory has been limited to low gas pressures and weak electronegative gases. High power devices, for example explosively driven magnetic flux compressors, operate at electrical field stresses, magnetic fields, and insulating gas pressures nearly two orders of magnitude greater than published research for crossed fields in gases. The primary limitation of conducting experiments at higher pressures, e.g. atmospheric, is generating the large magnetic fields, 10's Tesla, and electric fields, >100 kV/cm, required to see a significant effect. In this paper we describe measurements made with a coaxial geometry diode, form factor of 1.2, operating at peak electrical field stress of 220 kV/cm, maximum magnetic field of 20 Tesla, and SF{sub 6} pressure of 760 torr.

42 ENGINEERING↗

Electric Gradient Breakdown Results for the Orthogonal Box Cavity in a 3 T Magnetic Field

The Muon Collaboration (Palmer and D. Stratakis) has developed a theory for A method to suppress high electric field breakdown in vacuum cavities in high magnetic fields that are needed for a muon collider or neutrino factory. It has been shown in our studies and by others that high gradient electric field emitted electrons (dark current) are the primary cause of breakdown. A DC magnetic field orthogonal to the RF electric accelerating field prevents dark current high field emitted electrons from traveling across the accelerating gap and therefore will prevent breakdown. We have built a test cavity ( TM‐2473‐APC) in the shape of a box to test this theory . The results of the first study are presented.

43 PARTICLE ACCELERATORS↗