Detecting sterile neutrinos with KATRIN like experiments

A sterile neutrino with mass in the eV range, mixing with ν-bar {sub e}, is allowed and possibly even preferred by cosmology and oscillation experiments. If such eV-mass neutrinos exist they provide a much better target for direct detection in beta decay experiments than the active neutrinos which are expected to have sub-eV masses. Their relatively high mass would allow for an easy separation from the primary decay signal in experiments such as KATRIN.

79 ASTRONOMY AND ASTROPHYSICS↗

Compressed shell conditions extracted from spectroscopic analysis of Ti K-shell absorption spectra with evaluation of line self-emission

Ti-doped tracer layers embedded in the shell at varying distances from the fuel-shell interface serve as a spectroscopic diagnostic for direct-drive experiments conducted at OMEGA. Detailed modeling of Ti K-shell absorption spectra produced in the tracer layer considers n = 1–2 transitions in F- through Li-like Ti ions in the 4400–4800 eV range, both including and excluding line self-emission. Testing the model on synthetic spectra generated from 1-D LILAC hydrodynamic simulations reveals that the model including self-emission best reproduces the simulation, while the model excluding self-emission overestimates electron temperature T{sub e} and density N{sub e} to a higher degree for layers closer to the core. The prediction of the simulation that the magnitude of T{sub e} and duration of Ti absorption will be strongly tied to the distance of the layer from the core is consistent with the idea that regions of the shell close to the core are more significantly heated by thermal transport out of the hot dense core, but more distant regions are less affected by it. The simulation predicts more time variation in the observed T{sub e}, N{sub e} conditions in the compressed shell than is observed in the experiment, analysis of which reveals conditions remain in the range T{sub e} = 400–600 eV and N{sub e} = 3.0–10.0 × 10{sup 24} cm{sup −3} for all but the most distant Ti-doped layer, with error bars ∼5% T{sub e} value and ∼10% N{sub e} on average. The T{sub e}, N{sub e} conditions of the simulation lead to a greater degree of ionization for zones close to the core than occurs experimentally, and less ionization for zones far from the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Green Bank and Effelsberg Radio Telescope Searches for Axion Dark Matter Conversion in Neutron Star Magnetospheres

Axion dark matter (DM) may convert to radio-frequency electromagnetic radiation in the strong magnetic fields around neutron stars. The radio signature of such a process would be an ultranarrow spectral peak at a frequency determined by the mass of the axion particle. In this work, we analyze data we collected from the Robert C. Byrd Green Bank Telescope in the L band and the Effelsberg 100-m Telescope in the $\textit{L}$ band and $\textit{S}$ band from a number of sources expected to produce bright signals of axion-photon conversion, including the Galactic center of the Milky Way and the nearby isolated neutron stars RX J0720.4-3125 and RX J0806.4-4123. We find no evidence for axion DM and are able to set constraints on the existence of axion DM in the highly motivated mass range between ~ 5 and 11 μ eV with the strongest constraints to date on axions in the ~10–11 μ eV range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Symmetry Breaking in the Lowest-Lying Excited-State of CCl4: Valence Shell Spectroscopy in the 5.0–10.8 eV Photon Energy Range

We report absolute high-resolution vacuum ultraviolet (VUV) photoabsorption cross-sections of carbon tetrachloride (CCl4) in the photon energy range 5.0–10.8 eV (248–115 nm). The molecular spectrum and electronic structure have been comprehensively investigated together with quantum chemical calculations, providing geometries, bond lengths, vertical excitation energies and oscillator strengths. The major electronic excitations have been assigned to valence and Rydberg transitions which are also accompanied by vibrational excitation assigned to degenerate stretching, v3′t2 and degenerate deformation v4′t2 modes. The rather complex nuclear dynamics along the degenerate deformation mode, v4′t2, have been thoroughly investigated by Time-Dependent Density Functional Theory (TD-DFT) method. The relevant Jahn–Teller distortion operative within the lowest-lying electronic excited-state is shown here for the first time in order to yield a weak absorption feature at 6.156 eV. Further calculations on the potential energy curves for the singlet excited-states along the C–Cl stretching coordinate show the relevance of efficient C–Cl bond excision.

Biochemistry & Molecular Biology↗

Cleaning graphene: A first quantum/classical molecular dynamics approach

Graphene outstanding properties created a huge interest in the condensed matter community and unprecedented fundings at the international scale in the hope of application developments. Recently, there have been several reports of incomplete removal of the polymer resists used to transfer as-grown graphene from one substrate to another, resulting in altered graphene transport properties. Finding a large-scale solution to clean graphene from adsorbed residues is highly desirable and one promising possibility would be to use hydrogen plasmas. In this spirit, we couple here quantum and classical molecular dynamics simulations to explore the kinetic energy ranges required by atomic hydrogen to selectively etch a simple residue—a CH{sub 3} group—without irreversibly damaging the graphene. For incident energies in the 2–15 eV range, the CH{sub 3} radical can be etched by forming a volatile CH{sub 4} compound which leaves the surface, either in the CH{sub 4} form or breaking into CH{sub 3} + H fragments, without further defect formation. At this energy, adsorption of H atoms on graphene is possible and further annealing will be required to recover pristine graphene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron collisions with methyl-substituted ethylenes: Cross section measurements and calculations for 2-methyl–2-butene and 2,3-dimethyl–2-butene

We report electron-scattering cross sections determined for 2-methyl–2-butene [(H{sub 3}C)HC = C(CH{sub 3}){sub 2}] and 2,3-dimethyl–2-butene [(H{sub 3}C){sub 2}C = C(CH{sub 3}){sub 2}] molecules. Absolute grand-total cross sections (TCSs) were measured for incident electron energies in the 0.5–300 eV range, using a linear electron-transmission technique. The experimental TCS energy dependences for the both targets appear to be very similar with respect to the shape. In each TCS curve, three features are discernible: the resonant-like structure located around 2.6–2.7 eV, the broad distinct enhancement peaking near 8.5 eV, and a weak hump in the vicinity of 24 eV. Theoretical integral elastic (ECS) and ionization (ICS) cross sections were computed up to 3 keV by means of the additivity rule (AR) approximation and the binary-encounter-Bethe method, respectively. Their sums, (ECS+ICS), are in a reasonable agreement with the respective measured TCSs. To examine the effect of methylation of hydrogen sides in the ethylene [H{sub 2}C = CH{sub 2}] molecule on the TCS, we compared the TCS energy curves for the sequence of methylated ethylenes: propene [H{sub 2}C = CH(CH{sub 3})], 2-methylpropene [H{sub 2}C = C(CH{sub 3}){sub 2}], 2-methyl–2-butene [(H{sub 3}C)HC = C(CH{sub 3}){sub 2}], and 2,3-dimethyl–2-butene [(H{sub 3}C){sub 2}C = C(CH{sub 3}){sub 2}], measured in the same laboratory. Moreover, the isomeric effect is also discussed for the C{sub 5}H{sub 10} and C{sub 6}H{sub 12} compounds.

2-METHYLPROPENE↗

Si-Ge-Sn alloys with 1.0 eV gap for CPV multijunction solar cells

Si-Ge-Sn ternary group IV alloys offer an alternative to currently used 1.0 eV gap materials utilized in multijunction solar cells. The advantage of Si-Ge-Sn is the ability to vary both the bandgap and lattice parameter independently. We present current development in fabrication of Si-Ge-Sn alloys with gaps in the 1.0 eV range. Produced material exhibits excellent structural properties, which allow for integration with existing III-V photovoltaic cell concepts. Time dependent room temperature photoluminescence data demonstrate that these materials have long carrier lifetimes. Absorption tunable by compositional changes is observed. As a prototype device set utilizing the 1 eV Si-Ge-Sn junction, single junction Si-Ge-Sn device and triple junction device with Si-Ge-Sn subcell have been fabricated. The resulting I-V and external quantum efficiency data show that the Si-Ge-Sn junction is fully functional and the performance is comparable to other 1.0 eV gap materials currently used.

14 SOLAR ENERGY↗

The Goddard Space Flight Center Solid State Spectrometer for the HEAO-B Mission

A non-dispersive, cryogenically-cooled X-ray detector system, to be flown as one of the focal-plane experiments on the High Energy Astrophysical Observatory-B, is described. The instrument is designed to measure the X-ray flux in the 500 eV to 5000 eV range with an energy resolution of 150 eV (pulser) and a temporal resolution approaching 2 microsec.

Joyce, R. M.↗

The mass dependence of wave particle interactions as observed with the ISEE-1 energetic ion mass spectrometer

Simultaneous measurements of the O(+) and H(+) distributions from two transverse acceleration events in the high altitude auroral ionosphere are presented. The data were acquired from the energetic ion mass spectrometer on the ISEE-1 satellite, in the dusk sector, on auroral field lines (L = 8-9), at geocentric radial distances of about 3 earth radii. Temporal and/or spatial fluctuations during the measurement cycle resulted in some scatter of the data points, but the transverse velocity distributions are reasonably well represented by maxwellians at energies in the few hundred eV range. The transverse temperatures were about 60 eV in both cases and no significant differences were observed between the temperatures of the O(+) and H(+). The flux intensities of the two ion species were also generally comparable.

Sharp, R. D.↗

Characterization of x-ray photocathode in transmission mode for imaging application

The performance of an Al x-ray transmission photocathode was experimentally characterized by measuring the total electron yield from backsurface photocathodes of varying thickness. It was demonstrated that the backsurface electron yield is proportional to the x-ray photocurrent transmitted through the photocathode for thicknesses thicker than the optimum thickness. The optimum photocathode thickness with the highest conversion efficiency was found to be approximately 70 nm at 2.963 keV. An escape depth of the secondary electrons was determined to be approximately 13 nm from the yield-versus-thickness data fitted with a semiempirical equation. Using this parameter, the dependence of the optimum photocathode thickness on the x-ray energy was calculated for the 30-10000 eV range. As one example of imaging applications, different photoemission images in the transmission and reflection modes are also presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron spectrometer in adjustable triode configuration for photo-induced field emission measurements

We have constructed a new ultrahigh vacuum apparatus with a triode configuration for the systematic investigation of photo-induced field emission (PFE) from metallic or semiconducting cathodes. These are exposed to electric fields up to 400 MV/m and laser irradiation by means of hole or mesh gates. Cathodes and gates are in situ exchangeable and adjustable with high precision to ensure a homogeneous extraction of electrons which are partially transmitted to the fixed electron spectrometer. Its hemispherical sector analyzer provides an energy resolution limit of 8 meV. The commissioning of the measurement system has been performed with a tungsten needle. Its temperature showed up in the high-energy tail of the electron spectrum, while its work function was derived from the spectral low-energy part combined with the integral current-voltage curve. First PFE measurements on B-doped Si-tip arrays yielded a small field emission current increase under green laser illumination. A shift and splitting of the energy spectra was observed which revealed different emission regimes as well as the photosensitivity of the cathode due to carrier excitation into the conduction band. For the full exploitation of the PFE system, a tunable laser over a wide eV-range is required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved optogalvanic detection with voltage biased Langmuir probes

Optogalvanic detectors show great potential for infrared spectroscopy, especially in cavity enhanced techniques where they, in contrast to ordinary absorption detectors, can perform intracavity measurements. This enables them to utilize the signal-to-noise ratio improvement gained from the extended effective path length inside an optical cavity, without losing signal strength due to the limited amount of light exiting through the rear mirror. However, if optogalvanic detectors are to become truly competitive, their intrinsic sensitivity and stability has to be improved. This, in turn, requires a better understanding of the mechanisms behind the generation of the optogalvanic signal. The study presented here focuses on an optogalvanic detector based on a miniaturized stripline split-ring resonator plasma source equipped with Langmuir probes for detecting the optogalvanic signal. In particular, the effect of applying a constant bias voltage to one of the probes is investigated, both with respect to the sensitivity and stability, and to the mechanism behind the generation of the signal. Experiments with different bias voltages at different pressures and gas composition have been conducted. In particular, two different gas compositions (pure CO{sub 2} and 0.25% CO{sub 2} in 99.75% N{sub 2}) at six different pressures (100 Pa to 600 Pa) have been studied. It has been shown that probe biasing effectively improves the performance of the detector, by increasing the amplitude of the signal linearly over one order of magnitude, and the stability by about 40% compared with previous studies. Furthermore, it has been shown that relatively straightforward plasma theory can be applied to interpret the mechanism behind the generation of the signal, although additional mechanisms, such as rovibrational excitation from electron-molecule collisions, become apparent in CO{sub 2} plasmas with electron energies in the 1–6 eV range. With the achieved performance improvement and the more solid theoretical framework presented here, stripline split-ring resonator optogalvanic detectors can evolve into a compact, inexpensive, and easy-to-operate alternative for future infrared spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE JLAMP VUV/SOFT X-RAY USER FACILITY AT JEFFERSON LABORATORY

Jefferson Lab (JLab) is proposing JLAMP (JLab Amplifier), a 4th generation light source covering the 10-100 eV range in the fundamental mode with harmonics stretching towards the oxygen k-edge. The new photon science user facility will feature a two-pass superconducting LINAC to accelerate the electron beam to 600MeV at repetition rates of 4.68MHz continuous wave. The average brightness from a seeded amplifier free electron laser (FEL) will substantially exceed existing light sources in this device's wavelength range, extended by harmonics towards 2 nm. Multiple photon sources will be made available for pump-probe dynamical studies. The status of the machine design and technical challenges associated with the development of the JLAMP are presented here.

43 PARTICLE ACCELERATORS↗

Sterile neutrinos with eV masses in cosmology — How disfavoured exactly?

We study cosmological models that contain sterile neutrinos with eV-range masses as suggested by reactor and short-baseline oscillation data. We confront these models with both precision cosmological data (probing the CMB decoupling epoch) and light-element abundances (probing the BBN epoch). In the minimal ΛCDM model, such sterile neutrinos are strongly disfavoured by current data because they contribute too much hot dark matter. However, if the cosmological framework is extended to include also additional relativistic degrees of freedom beyond the three standard neutrinos and the putative sterile neutrinos, then the hot dark matter constraint on the sterile states is considerably relaxed. A further improvement is achieved by allowing a dark energy equation of state parameter w < −1. While BBN strongly disfavours extra radiation beyond the assumed eV-mass sterile neutrino, this constraint can be circumvented by a small ν{sub e} degeneracy. Any model containing eV-mass sterile neutrinos implies also strong modifications of other cosmological parameters. Notably, the inferred cold dark matter density can shift up by 20–75% relative to the standard ΛCDM value.

79 ASTRONOMY AND ASTROPHYSICS↗

Thomson scattering at general fusion

This paper provides an overview of the Thomson scattering diagnostic in use at General Fusion, including recent upgrades and upcoming plans. The plasma experiment under examination produces temperatures in the 50-500 eV range with density on the order of 10{sup 20} m{sup −3}. A four spatial point collection optics scheme has been implemented, with plans to expand to six spatial points. Recent changes to the optics of the laser beamline have reduced stray light. The system employs a frequency doubled Nd:YAG laser (532 nm), a grating spectrometer, and a photomultiplier array based detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Compression in Heavy-Ion Induction Linacs

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the Warm Dense Matter regime, using space-charge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has been demonstrated in the LBNL Neutralized Drift Compression Experiment (NDCX) experiment with controlled ramps and forced neutralization. The achieved peak beam current and energy can be used in experiments to heat targets and create warm dense matter. Using an injected 30 mA K{sup +} ion beam with initial kinetic energy 0.3 MeV, axial compression leading to {approx}50x current amplification and simultaneous radial focusing to beam radii of a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss experiments that are under development to reach the necessary higher beam intensities and the associated beam diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extraction characteristics of a low-energy ion beam system with a remote plasma chamber

Low-energy argon beams were extracted from a dual-chamber ion source system. The first chamber is a quartz cylinder where dense inductively coupled plasmas were produced using 13.56 MHz radio frequency (rf) power. The discharge was driven into an adjacent chamber which acts as a reservoir for ion beam extraction using a dual-electrode extractor configuration. Extraction of ions from the second chamber with energies in the 100 eV range was achieved while minimizing fluctuations induced by the rf signal. A custom-built retarding potential analyzer was used to analyze the effectiveness of ion beam transport using the remote plasma chamber. Well-defined beams were extracted between 60 and 100 V extraction potentials at 50–100 W rf powers. An increase in rf power resulted in an increase in average ion energy, increase in ion current density while the energy spread remains constant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in Beam Focusing and Compression for Target Heating and Warm Dense Matter Experiments

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the warm dense matter regime, using space-charge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has been demonstrated in the Neutralized Drift Compression Experiment (NDCX) with controlled ramps and forced neutralization. Using an injected 30 mA K{sup +} ion beam with initial kinetic energy 0.3 MeV, axial compression leading to {approx}50X current amplification and simultaneous radial focusing to a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss the status of several improvements to NDCX to reach the necessary higher beam intensities, including: beam diagnostics, greater axial compression via a longer velocity ramp; and plasma injection improvements to establish a plasma density always greater than the beam density, expected to be > 10{sup 13} cm{sup -3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗