Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electrospray Ionization with High-Resolution Mass Spectrometry as a Tool for Lignomics: Lignin Mass Spectrum Deconvolution

The capability to characterize lignin, lignocellulose, and their degradation products is essential for the development of new renewable feedstocks. Electrospray ionization high-resolution time-of-flight mass spectrometry (ESI-HR TOF-MS) method was developed expanding the lignomics toolkit while targeting the simultaneous detection of low and high molecular weight (MW) lignin species. The effect of a broad range of electrolytes and various ionization conditions on ion formation and ionization effectiveness was studied using a suite of mono-, di-, and triarene lignin model compounds as well as kraft alkali lignin. Contrary to the previous studies, the positive ionization mode was found to be more effective for methoxy-substituted arenes and polyphenols, i.e., species of a broadly varied MW structurally similar to the native lignin. For the first time, we report an effective formation of multiply charged species of lignin with the subsequent mass spectrum deconvolution in the presence of 100 mmol L{sup −1} formic acid in the positive ESI mode. The developed method enabled the detection of lignin species with an MW between 150 and 9000 Da or higher, depending on the mass analyzer. The obtained M{sub n} and M{sub w} values of 1500 and 2500 Da, respectively, were in good agreement with those determined by gel permeation chromatography. Furthermore, the deconvoluted ESI mass spectrum was similar to that obtained with matrix-assisted laser desorption/ionization (MALDI)-HR TOF-MS, yet featuring a higher signal-to-noise ratio. The formation of multiply charged species was confirmed with ion mobility ESI-HR Q-TOF-MS. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolving the Discrepancies Between Empirical and Rayleigh Charge Limiting Models for Globular Proteins

Starting with the Rayleigh charge limiting model, a slightly different approach is used to account for the well-known discrepancy that exists between the said model and experimental ESI MS data for globular proteins. It is shown using published datasets that for globular proteins, the mass density ρ exhibits a weak second-order dependence on its mass M, according to ρ(M)∝M{sup -α}, α ~ 0.14. A direct equivalence established between ESI MS and x-ray techniques suggests a minimum but critical surface tension of 15.6 ± 5.2 mN/m for the droplet at the liquid-to-gas phase transition point. The packing density factor η for globular proteins is believed to lie between 1 (very tightly packed) and 4.6 (less tight, natively packed). While the Rayleigh charge limiting model has been linked historically to the CRM (J. Chem. Phys. 49:2240–2249, 1968; Anal. Chim. Acta 406:93–104, 2000), this paper does not expressly seek to justify the CRM, but rather uses empirical data and existing knowledge across subfields to help build a consistent picture of ESI MS phenomena that might be difficult to explain otherwise. These results would be useful in molecular dynamics (MD) simulations, understanding liquid-to-gas phase transitions and in opening up new routes for cross-calibration between ESI MS, IM MS, NMR and x-ray crystallography studies. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studying drought-induced forest mortality using high spatiotemporal resolution evapotranspiration data from thermal satellite imaging

Drought can have pervasive and wide-spread impacts to forest health, as evidenced in several severe events occurring over the recent decades. Extensive forest die-off due to drought can impair the ecological functioning of forests, impacting habitat, water yield and quality from forested lands, and altering forest fire dynamics and intensity. Satellite remote sensing provides an effective means for detecting and monitoring spatial patterns of forest mortality over large areas, exploiting free and open long-term image archives available at a range in spatial and temporal resolutions. While remotely sensed surface reflectances and vegetation indices have been widely used to study optical response of forest canopies to drought events, retrievals of evapotranspiration (ET) derived from thermal satellite imagery – particularly at resolutions approaching crown scale - can provide insights into cumulative tree stresses that can incite disease and trigger mortality. In this study, we applied a multi-sensor satellite data fusion approach to estimate daily 30-m resolution ET and an associated Evaporative Stress Index (ESI) to study drought-induced mortality in a temperate forest at the Missouri Ozark AmeriFlux (MOFLUX) site, located in the central United States. The study covered the period from 2010 to 2014, including an exceptional drought year of 2012. Modeled ET agreed well with eddy flux measurements from the MOFLUX tower, with average monthly relative errors of 15%. Plot-scale ESI, describing temporal anomalies in the ratio of actual-to-reference ET, was used as an index of relative forest health to investigate relationships between forest mortality and drought severity. ESI showed good agreement with observed predawn leaf water potential, especially during the drought year. Furthermore, plot-scale ESI was also correlated with the subsequent year's tree mortality, suggesting the importance of considering the forest health condition prior to drought when studying drought-induced forest impacts. This study demonstrates the utility of multi-year ET remote sensing data at the stand or plot scale as an indicator of forest health and as a predictor of future mortality due to drought.

54 ENVIRONMENTAL SCIENCES↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

Probing the early stages of salt nucleation—Experimental and theoretical investigations of sodium/potassium thiocyanate cluster anions

Due to the fast solvent evaporation in electrospray ionization (ESI), the concentration of initially dilute electrolyte solutions rapidly increases to afford the formation of supersaturated droplets and generation of various pristine anhydrous salt clusters in the gas phase. The size, composition, and charge distributions of these clusters, in principle, witness the nucleation evolution in solutions. Herein, we report a microscopic study on the initial stage of nucleation and crystallization of sodium/potassium thiocyanate salt solutions simulated in the ESI process. Singly charged M{sub x}(SCN){sub x+1}{sup −}, doubly charged M{sub y}(SCN){sub y+2}{sup 2−} (M = Na, K), and triply charged K{sub z}(SCN){sub z+3}{sup 3−} anion clusters (x, y, and z stand for the number of alkali atoms in the singly, doubly, and triply charged clusters, respectively) were produced via electrospray of the corresponding salt solutions and were characterized by negative ion photoelectron spectroscopy (NIPES). The vertical detachment energies (VDEs) of these sodium/potassium thiocyanate cluster anions were obtained, and theoretical calculations were carried out for the sodium thiocyanate clusters in assisting spectral identification. The measured VDEs of singly charged anions M{sub x}(SCN){sub x+1}{sup −} (M = Na and K) demonstrate that they are superhalogen anions. The existence of doubly charged anions M{sub y}(SCN){sub y+2}{sup 2−} (y = 2x, x ≥ 4 and 3 for M = Na and K, respectively) and triply charged anions K{sub z}(SCN){sub z+3}{sup 3−} (z = 3x, x ≥ 6) was initially discovered from the photoelectron spectra for those singly charged anions of M{sub x}(SCN){sub x+1}{sup −} with the same mass-to-charge ratio (m/z), and later independently confirmed by the observation of their distinct mass spectral distributions and by taking their NIPE spectra for those pure multiply charged anions with their m/z different from the singly charged species. For large clusters, multiply charged clusters were found to become preferred, but at higher temperatures, those multiply charged clusters were suppressed. The series of anion clusters investigated here range from molecular-like M{sub 1}(SCN){sub 2}{sup −} to nano-sized K{sub 22}(SCN){sub 25}{sup 3−}, providing a vivid molecular-level growth pattern reflecting the initial salt nucleation process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perspective: Electrospray photoelectron spectroscopy: From multiply-charged anions to ultracold anions

Electrospray ionization (ESI) has become an essential tool in chemical physics and physical chemistry for the production of novel molecular ions from solution samples for a variety of spectroscopic experiments. ESI was used to produce free multiply-charged anions (MCAs) for photoelectron spectroscopy (PES) in the late 1990 s, allowing many interesting properties of this class of exotic species to be investigated. Free MCAs are characterized by strong intramolecular Coulomb repulsions, which create a repulsive Coulomb barrier (RCB) for electron emission. The RCB endows many fascinating properties to MCAs, giving rise to meta-stable anions with negative electron binding energies. Recent development in the PES of MCAs includes photoelectron imaging to examine the influence of the RCB on the electron emission dynamics, pump-probe experiments to examine electron tunneling through the RCB, and isomer-specific experiments by coupling PES with ion mobility for biological MCAs. The development of a cryogenically cooled Paul trap has led to much better resolved PE spectra for MCAs by creating vibrationally cold anions from the room temperature ESI source. Recent advances in coupling the cryogenic Paul trap with PE imaging have allowed high-resolution PE spectra to be obtained for singly charged anions produced by ESI. In particular, the observation of dipole-bound excited states has made it possible to conduct vibrational autodetachment spectroscopy and resonant PES, which yield much richer vibrational spectroscopic information for dipolar free radicals than traditional PES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Simulation-Based Structural Prediction of Protein Complexes in Mass Spectrometry: The Human Insulin Dimer

Protein electrospray ionization (ESI) mass spectrometry (MS)-based techniques are widely used to provide insight into structural proteomics under the assumption that non-covalent protein complexes being transferred into the gas phase preserve basically the same intermolecular interactions as in solution. Here we investigate the applicability of this assumption by extending our previous structural prediction protocol for single proteins in ESI-MS to protein complexes. We apply our protocol to the human insulin dimer (hIns2) as a test case. Our calculations reproduce the main charge and the collision cross section (CCS) measured in ESI-MS experiments. Molecular dynamics simulations for 0.075 ms show that the complex maximizes intermolecular non-bonded interactions relative to the structure in water, without affecting the cross section. The overall gas-phase structure of hIns2 does exhibit differences with the one in aqueous solution, not inferable from a comparison with calculated CCS. Hence, care should be exerted when interpreting ESI-MS proteomics data based solely on NMR and/or X-ray structural information.

59 BASIC BIOLOGICAL SCIENCES↗

Exploration Systems Development (ESD) Approach to Enterprise Risk Management

The National Aeronautics and Space Administration (NASA) Exploration Systems Development (ESD) Division has implemented an innovative approach to Enterprise Risk Management under a unique governance structure and streamlined integration model. ESD's mission is to design and build the capability to extend human existence to deep space. The Enterprise consists of three Programs: Space Launch System (SLS), Orion, and Ground Systems Development and Operations (GSDO). The SLS is a rocket and launch system that will be capable of powering humans, habitats, and support systems to deep space. Orion will be the first spacecraft in history capable of taking humans to multiple destinations within deep space. GSDO is modernizing Kennedy's spaceport to launch spacecraft built and designed by both NASA and private industry. ESD's approach to Enterprise Risk Management is commensurate with affordability and a streamlined management philosophy. ESD Enterprise Risk Management leverages off of the primary mechanisms for integration within the Enterprise. The Enterprise integration approach emphasizes delegation of authority to manage and execute the majority of cross-program activities and products to the individual Programs, while maintaining the overall responsibility for all cross-program activities at the Division. The intent of the ESD Enterprise Risk Management approach is to improve risk communication, to avoid replication and/or contradictory strategies, and to minimize overhead process burden. This is accomplished by the facilitation and integration of risk information within ESD. The ESD Division risks, Orion risks, SLS risks, and GSDO risks are owned and managed by the applicable Program. When the Programs have shared risks with multiple consequences, they are jointly owned and managed. When a risk is associated with the integrated system that involves more than one Program in condition, consequence, or mitigation plan, it is considered an Exploration Systems Integration (ESI) Risk. An ESI risk may require visibility and risk handling by multiple organizations. The Integrated Risk Working Group (IRWG) is a small team of Risk experts that are responsible for collaborating and communicating best practices. In addition, the forum facilitates proper integration of risks across the Enterprise. The IRWG uses a Continuous Risk Management approach for facilitating the identification, analysis, planning, tracking, and controlling of ESI Risks. The ESD Division, Programs, and Integrated Task Teams identify ESI Risks. The IRWG maintains a set of metrics for understanding Enterprise Risk process and the overall Risk Posture. The team is also actively involved in the modeling of risk for Enterprise Performance Management. With the Enterprise being constrained in Schedule and Budget, and with significant technical complexity, the appropriate use of Risk Management techniques is crucial to the success of the Enterprise. The IRWG achieves this through the modified approach, providing a forum for collaboration on risks that cross boundaries between the separate entities.

Bauder, Stephen P.↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of natural organic matter in low-carbon sediments: Extraction and analytical approaches

Sediment-associated natural organic matter (NOM) is a complex assemblage of organic molecules with a wide range of sizes, functional groups, and structures, which is intricately associated with mineral particles. Organic carbon (OC) concentrations in subsurface sediments are typically 10 to 200 times lower than in surface soils, posing a distinct challenge for characterization. A range of chemical extractions were evaluated for extraction of NOM, and a NOM extraction scheme was developed using a combination of sequential extraction with water (MQ) and sodium pyrophosphate at pH 10 (PP), and purification by dialysis and solid phase extraction in order to isolate different fractions of sediment-associated NOM. Analysis of these different NOM fractions was then carried out by Fourier transform infrared spectroscopy (FTIR), ultraviolet-visible (UV-Vis) spectroscopy, and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS). The OC extraction efficiency of the tested extractions followed the order PP>NaOH>HCl=hydroxylamine hydrochloride>dithionite. Greater concentrations of OC in PP vs NaOH extracts suggest that metal complexation and/or ligand exchange plays an important role in OC stabilization. Characterization of different pools of extraction NOM by FITR shows that the water soluble fraction has a higher fraction of aliphatic and carboxylic groups, while the PP fractions have higher C=C groups. This trend from aliphatic to more aromatic is also supported by the UV-Vis and ESI-FTICR-MS data.

Environmental Molecular Sciences Laboratory↗

Synthesis and Characterization of a Masked Terminal Nickel-Oxide Complex

In exploring terminal nickel-oxo complexes, postulated to be the active oxidant in natural and non-natural oxidation reactions, we report the synthesis of the pseudo-trigonal bipyramidal Ni II complexes (K)[Ni II (L Ph )(DMF)] (1[DMF]) and (NMe 4 ) 2 [Ni II (L Ph )(OAc)] (1[OAc]) (L Ph =2,2’,2’’-nitrilo-tris-(N-phenylacetamide); DMF=N,N-dimethylformamide; - OAc=acetate). Both complexes were characterized using NMR, FTIR, ESI-MS, and X-ray crystallography, showing the L Ph ligand to bind in a tetradentate fashion, together with an ancillary donor. The reaction of 1[OAc] with peroxyphenyl acetic acid (PPAA) resulted in the formation of [(L Ph )Ni III -O-H∙∙∙OAc] 2- , 2, that displays many of the characteristics of a terminal Ni=O species. 2 was characterized by UV-Vis, EPR, and XAS spectroscopies and ESI-MS. 2 decayed to yield a Ni II -phenolate complex 3 (through aromatic electrophilic substitution) that was characterized by NMR, FTIR, ESI-MS, and X-ray crystallography. 2 was capable of hydroxylation of hydrocarbons and epoxidation of olefins, as well as oxygen atom transfer oxidation of phosphines at exceptional rates. While the oxo-wall remains standing, this complex represents an excellent example of a masked metal-oxide that displays all of the properties expected of the ever elusive terminal M=O beyond the oxo-wall.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unambiguous metabolite identification in high-throughput metabolomics by hybrid 1D 1 H NMR/ESI MS 1 approach: Hybrid 1D 1 H NMR/ESI MS 1 metabolomics method

We present a novel approach to improve accuracy of metabolite identification by combining direct infusion ESI MS1 with 1D 1H NMR spectroscopy. The new approach first applies standard 1D 1H NMR metabolite identification protocol by matching the chemical shift, J-coupling and intensity information of experimental NMR signals against the NMR signals of standard metabolites in metabolomics library. This generates a list of candidate metabolites. The list contains false positive and ambiguous identifications. Next, we constrained the list with the chemical formulas derived from high-resolution direct infusion ESI MS1 spectrum of the same sample. Detection of the signals of a metabolite both in NMR and MS significantly improves the confidence of identification and eliminates false positive identification. 1D 1H NMR and direct infusion ESI MS1 spectra of a sample can be acquired in parallel in several minutes. This is highly beneficial for rapid and accurate screening of hundreds of samples in high-throughput metabolomics studies. In order to make this approach practical, we developed a software tool, which is integrated to Chenomx NMR Suite. The approach is demonstrated on a model mixture, tomato and Arabidopsis thaliana metabolite extracts, and human urine.

Environmental Molecular Sciences Laboratory↗

Atmospheric Pressure Ionization Using a High Voltage Target Compared to Electrospray Ionization

A new atmospheric pressure ionization (API) source, viz. UniSpray, was evaluated for mass spectrometry (MS) analysis of pharmaceutical compounds by head-to-head comparison with electrospray ionization (ESI) on the same high-resolution MS system. The atmospheric pressure ionization source is composed of a grounded nebulizer spraying onto a high voltage, cylindrical stainless steel target. Molecules are ionized in a similar fashion to electrospray ionization, predominantly producing protonated or deprotonated species. Adduct formation (e.g., proton and sodium adducts) and in-source fragmentation is shown to be almost identical between the two sources. The performance of the new API source was compared with electrospray by infusion of a mix of 22 pharmaceutical compounds with a wide variety of functional groups and physico-chemical properties (molecular weight, logP, and pKa) in more than 100 different conditions (mobile phase strength, solvents, pH, and flow rate). The new API source shows an intensity gain of a factor 2.2 compared with ESI considering all conditions on all compounds tested. Finally, some hypotheses on the ionization mechanism, similarities, and differences with ESI, are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a New Aerodynamic Cylindrical FAIMS Device for Small Molecule Analysis

The implementation of an aerodynamic mechanism to improve ion sampling between nanoelectrospray (n-ESI) and FAIMS was recently reported for proteomic analyses. This investigation explores the new FAIMS interface for small molecule analysis at high liquid flow rates and includes an examination of key differences in ionization between heated-ESI (HESI) and n-ESI. The sheath gas, critical for desolvation with HESI, affects FAIMS operation as higher FAIMS gas flow rates are required to achieve sufficient desolvation. Gas flow rate experiments also uncovered m/z discrimination with the conventional design as larger (slower moving) m/z ions experienced larger signal intensity losses than smaller m/z ions due to the desolvation gas flow having a greater drag effect on slower moving ions. The modified inlet in new FAIMS dampens the gas drag, making the HESI source more amenable as less m/z bias and significantly lower %RSD values were observed. Furthermore, a larger radius inner electrode in new FAIMS enables significantly higher E/N (electric field/number gas density) to be achieved using the existing waveform generator. Thus, new FAIMS signal intensities using only nitrogen improved 1.25- to 2-fold compared with the conventional design and 50% helium. Adding helium to the new FAIMS gave no significant improvements. The larger inner electrode also decreased ion focusing capabilities, and the effect on peak separation and ion intensity was examined in detail. The peak capacity of new FAIMS was approximately double that of conventional FAIMS; separation of seven low m/z ions gave a peak capacity of 37.7 using the gas additive 2-propanol. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delivering Transmembrane Peptide Complexes to the Gas Phase Using Nanodiscs and Electrospray Ionization

The gas-phase conformations of dimers of the channel-forming membrane peptide gramicidin A (GA), produced from isobutanol or aqueous solutions of GA-containing nanodiscs (NDs), are investigated using electrospray ionization-ion mobility separation-mass spectrometry (ESI-IMS-MS) and molecular dynamics (MD) simulations. The IMS arrival times measured for (2GA + 2Na){sup 2+} ions from isobutanol reveal three different conformations, with collision cross-sections (Ω) of 683 Å{sup 2} (conformation 1, C1), 708 Å{sup 2} (C2), and 737 Å{sup 2} (C3). The addition of NH{sub 4}CH{sub 3}CO{sub 2} produced (2GA + 2Na){sup 2+} and (2GA + H + Na){sup 2+} ions, with Ω similar to those of C1, C2, and C3, as well as (2GA + 2H){sup 2+}, (2GA + 2NH{sub 4}){sup 2+}, and (2GA + H + NH{sub 4}){sup 2+} ions, which adopt a single conformation with a Ω similar to that of C2. These results suggest that the nature of the charging agents, imparted by the ESI process, can influence dimer conformation in the gas phase. Notably, the POPC NDs produced exclusively (2GA + 2NH{sub 4}){sup 2+} dimer ions; the DMPC NDs produced both (2GA + 2H){sup 2+} and (2GA + 2NH{sub 4}){sup 2+} dimer ions. While the Ω of (2GA + 2H){sup 2+} is similar to that of C2, the (2GA + 2NH{sub 4}){sup 2+} ions from NDs adopt a more compact structure, with a Ω of 656 Å{sup 2}. It is proposed that this compact structure corresponds to the ion conducting single stranded head-to-head helical GA dimer. These findings highlight the potential of NDs, combined with ESI, for transferring transmembrane peptide complexes directly from lipid bilayers to the gas phase. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles

A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transferring Ions from Solution to the Gas Phase: The Two Basic Principles

The efficient formation of gaseous ions is the crucial step in all successful mass spectrometric experiments. The invention of electrospray ionization (ESI) has strongly facilitated this step by transferring preformed ions directly from solution to the gas phase – thereby circumventing the need to first convert analytes to the gas phase and then ionize them – and therefore ESI has become an extremely useful and widely applied MS technique. The invention of sonic spray ionization (SSI) has also allowed for the transfer of ions from solution into the gas phase, but without the assistance of a voltage or heating. Numerous ionization techniques, using similar principles to those applied in either ESI or SSI, have subsequently been developed. Although experimental conditions used in such techniques vary markedly, herein we argue that they are all based on either one of two basic principles by which ions can be transferred from solution to the gas phase, that is: via (1) neutralizing the counter ion, or (2) separating the ions. We have selected 35 such techniques and categorized them accordingly. This article thereby aims to establish the basic principles by which gaseous ions can be obtained from solvated ions. We further propose that any new ionization technique used to transfer solvated ions to the gas phase will similarly fall into one of these two mechanistic categories. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Top-Down Analysis of Proteins in Low Charge States

The impact of charging methods on the dissociation behavior of intact proteins in low charge states is investigated using HCD and 193 nm UVPD. Low charge states are produced for seven different proteins using the following four different methods: (1) proton transfer reactions of ions in high charge states generated from conventional denaturing solutions; (2) ESI of proteins in solutions of high ionic strength to enhance retention of folded native-like conformations; (3) ESI of proteins in high pH solutions to limit protonation; and (4) ESI of carbamylated proteins. Comparison of sequence coverages, degree of preferential cleavages, and types and distribution of fragment ions reveals a number of differences in the fragmentation patterns depending on the method used to generate the ions. More notable differences in these metrics are observed upon HCD than upon UVPD. The fragmentation caused by HCD is influenced more significantly by the presence/absence of mobile protons, a factor that modulates the degree of preferential cleavages and net sequence coverages. Carbamylation of the lysines and the N-terminus of the proteins alters the proton mobility by reducing the number of proton-sequestering, highly basic sites as evidenced by decreased preferential fragmentation C-terminal to Asp or N-terminal to Pro upon HCD. UVPD is less dependent on the method used to generate the low charge states and favors non-specific fragmentation, an outcome which is important for obtaining high sequence coverage of intact proteins. .

74 ATOMIC AND MOLECULAR PHYSICS↗