Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

Understanding Artifacts in Impedance Spectroscopy

Four-terminal measurements of impedance spectra have long been troubled by the presence of high frequency artifacts that typically indicate unphysically large inductive behavior. In this paper, we follow up on the observation of Fleig et al., that voltage and current are necessarily measured in different locations of the potentiostat circuit, and that, typically, the electrometer input is a virtual ground. In this case, the capacitance of coaxial cables that connect sample electrodes to the potentiostat provides a high frequency conduction path to ground, so that some of the current that passes through the sample bypasses the electrometer. In four-electrode measurements, this mechanism produces the observed inductive artifacts. We examine a variety of simulated samples, with calculations compared to measurements of relevant circuits, to quantitatively investigate the nature of the artifacts. Model results agree with measurements when the leakage capacitances are properly included in the circuit analyses. With understanding of the origin of the inductive artifacts, the four-electrode method can be effectively utilized, enabling a combination of two-, three- and four-electrode measurements to be used to best advantage. Finally, using this combination of electrode configurations, temperature dependent measurements of SrTiO 3 , Y 2 O 3 -stabilized ZrO 2 , and In 2 O 3 films deposited on YSZ substrates are presented.

36 MATERIALS SCIENCE↗

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Development of the cosmic ray techniques

It has been found that most advances of cosmic-ray physics have been directly related to the development of observational techniques. The history of observational techniques is discussed, taking into account ionization chambers, refinements applied to ionization chambers to make them suitable for an effective use in the study of cosmic radiation, the Wulf-type electrometer, the electrometer designed by Millikan and Neher, the Geiger-Mueller counter, the experiment of Bothe and Kolhoerster, the coincidence circuit, and a cosmic-ray 'telescope'. Attention is given to a magnetic lens for cosmic rays, a triangular arrangement of Geiger-Mueller counters used to demonstrate the production of a secondary radiation, a stereoscopic cloud-chamber photograph of showers, the cloud-chamber picture which provided the first evidence of the positive electron, and arrangements for studying photon components, mu-mesons, and air showers.

Rossi, B.↗

The electrodynamometric balance of the small wind tunnel of the French Service of Aeronautical Research

This investigation shows the attempt to improve the electrodynamomoter designed by Mr. Villey. The force to be measured acts on a flexible steel plate which is placed in front of a fixed plate. The deformation varies the original thickness of the layer of air between the two plates, thus causing a more rapid variation in the coefficient of electrostatic attraction of the two plates than in the capacity of the condenser formed by the dynamometer. The measurements are made by a differential method. The capacity of the test dynamometer is compared with that of a similar instrument of constant capacity, this comparison being made by means of an electrometer. Diagrams are shown of the dynamometer, the electrometer, and the electrical connections.

Rebuffet, P↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Proposed Modifications to Engineering Design Guidelines Related to Resistivity Measurements and Spacecraft Charging

A key parameter in modeling differential spacecraft charging is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across the spacecraft, as well as the time scale for charge transport and dissipation. Existing spacecraft charging guidelines recommend use of tests and imported resistivity data from handbooks that are based principally upon ASTM methods that are more applicable to classical ground conditions and designed for problems associated with power loss through the dielectric, than for how long charge can be stored on an insulator. These data have been found to underestimate charging effects by one to four orders of magnitude for spacecraft charging applications. A review is presented of methods to measure the resistive of highly insulating materials, including the electrometer-resistance method, the electrometer-constant voltage method, the voltage rate-of-change method and the charge storage method. This is based on joint experimental studies conducted at NASA Jet Propulsion Laboratory and Utah State University to investigate the charge storage method and its relation to spacecraft charging. The different methods are found to be appropriate for different resistivity ranges and for different charging circumstances. A simple physics-based model of these methods allows separation of the polarization current and dark current components from long duration measurements of resistivity over day- to month-long time scales. Model parameters are directly related to the magnitude of charge transfer and storage and the rate of charge transport. The model largely explains the observed differences in resistivity found using the different methods and provides a framework for recommendations for the appropriate test method for spacecraft materials with different resistivities and applications. The proposed changes to the existing engineering guidelines are intended to provide design engineers more appropriate methods for consideration and measurements of resistivity for many typical spacecraft charging scenarios.

Dennison, J. R.↗

Charge-coupled-device parallel-to-serial converter

A CCD parallel-to-serial converter comprising two successions of charge transfer stages, recurrently side-loaded with respective ones of parallelly supplied charge packets, then serially unloaded by time-interleaved respective shift register operations. The charge packets converted to time-division-multiplexed serial form are supplied to a shared electrometer, and the electrometer response is de-multiplexed. Preferably, shift register operations are carried forward concurrently at the same rate, but with the final charge transfer stages clocked in phases staggered in time.

Tower, John R.↗

Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the voltage offsets were measured as a function of initial voltage, and these data were fitwith a linear function that was constrained to pass through the origin. The best fit solution had a correlation coefficient of R=0.85 and a slope of approximately -0.0228 volts/volt. The voltage offset when normalizedis demonstrated to be constant -2.28% for both positive and negative polarities over nearly 3 orders ofbaseline voltage magnitude. From this, the voltage-force coefficient is derived to be -0.34 ppm/N. Thiscorrelates well to a first-order parallel plate capacitor model that assumes constant area, and smalldeformation such that the polymer may be mechanically modeled by a spring that obeys Hookes law. Thissimple model predicts that the coefficient of proportionality is a function of Youngs modulus E= 0.8 GPaand surface area of the insulator, theoretically -1EA= -0.31 ppm/N. The outcome of this work is animproved insulator made from ultra-high molecular weight (UHMW) polyethylene and other approachestoward the minimization of and compensation for these experimental artifacts.

Electromagnetic Studies of Rocks↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

High-Vacuum Triboelectric Charging of Space Materials

In the high-vacuum environment of space and the surface of the moon, static electricity on surfaces lacks the atmospheric dissipation mechanisms found on earth. As a result, the ubiquitous triboelectric charging mechanism can lead to high levels of charge on surfaces. This static charge can result in damage to sensitive devices, interfere with communications, and electrostatic levitation of lunar dust. At the NASA Electrostatics and Surface Physics Laboratory (ESPL), we use different apparatuses and techniques to tribo-charge materials in high-vacuum (10-5 torr), including a tribo-robot and a triboelectric regolith-material stage (TRMS). The tribo-robot is used to rub two materials together, and fieldmeters and electrometers can be used to determine how much charge is on the materials. The TRMS is used to drag different materials onto a bed of lunar simulant. This system is used to characterize how materials may interact with lunar dust using fieldmeters, electrometers, and laser scattering. Using these methods, we are building a database of how different space materials charge when contacting each other at high-vacuum, and how materials triboelectrically interact with the lunar surface.

Joseph Toth↗

Effect of confining wall potential on charged collimated dust beam in low-pressure plasma

The effect of confining wall potential on charged collimated dust beam in low-pressure plasma has been studied in a dusty plasma experimental setup by applying electrostatic field to each channel of a multicusp magnetic cage. Argon plasma is produced by hot cathode discharge method at a pressure of 5×10{sup −4} millibars and is confined by a full line cusped magnetic field confinement system. Silver dust grains are produced by gas-evaporation technique and move upward in the form of a collimated dust beam due to differential pressure maintained between the dust and plasma chambers. The charged grains in the beam after coming out from the plasma column enter into the diagnostic chamber and are deflected by a dc field applied across a pair of deflector plates at different confining potentials. Both from the amount of deflection and the floating potential, the number of charges collected by the dust grains is calculated. Furthermore, the collimated dust beam strikes the Faraday cup, which is placed above the deflector plates, and the current (∼pA) so produced is measured by an electrometer at different confining potentials. The experimental results demonstrate the significant effect of confining wall potential on charging of dust grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct detection of a transport-blocking trap in a nanoscaled silicon single-electron transistor by radio-frequency reflectometry

The continuous downscaling of transistors results in nanoscale devices which require fewer and fewer charged carriers for their operation. The ultimate charge controlled device, the single-electron transistor (SET), controls the transfer of individual electrons. It is also the most sensitive electrometer, and as a result the electron transport through it can be dramatically affected by nearby charges. Standard direct-current characterization techniques, however, are often unable to unambiguously detect and resolve the origin of the observed changes in SET behavior arising from changes in the charge state of a capacitively coupled trap. Using a radio-frequency (RF) reflectometry technique, we are able to unequivocally detect this process, in very close agreement with modeling of the trap's occupation probability.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Studies on hydrogen plasma and dust charging in low-pressure filament discharge

The effect of working gas pressure and dust charging on electron energy probability function has been studied for hydrogen plasma in a multi-dipole dusty plasma device. A cylindrical Langmuir probe is used to evaluate the plasma parameters and electron energy probability function (EEPF) for different working pressures. For lower energy range (below 10 eV), the EEPF follows a bi-Maxwellian shape at very low pressure (6 × 10{sup −5} mbar), while elevating the working pressure up to ∼2 × 10{sup −3} mbar, the shape of the EEPF transforms into a single Maxwellian. Some dip structures are observed at high energy range (ε > 10 eV) in the EEPF of hydrogen plasma at all the working conditions. In presence of dust particles, it is observed that the shape of the EEPF changes due to the redistribution of the high and low-energy electron populations. Finally, the effect of working pressure on charge accumulation on dust particles is studied with the help of a Faraday cup and electrometer. From the observations, a strong influence of working pressure on plasma parameters, EEPF and dust charging is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of 200 keV Ar{sup +} implantation on optical and electrical properties of polyethyleneterepthalate (PET)

In the present paper we have discussed the effect of 200 keV Ar{sup +} ions on the electrical and optical properties of PET samples. PET samples were implanted with 200 keV Ar{sup +} ions to various doses ranging from 1×10{sup 15} to 1×10{sup 17} Ar{sup +} cm{sup 2}. The changes in the electrical and optical properties of pristine and implanted PET specimens have been studied by using Keithley electrometer and UV-Visible absorption spectroscopy. The electrical conductivity has found to be increased with increasing ion dose. The optical studies have revealed the drastic alterations in optical band gap from 3.63 eV to 1.48 eV and also increase in number of carbon atoms per cluster from 215 to 537. Further, the change in the electrical conductivity and optical band gap has also been correlated with the formation of conductive islands in the implanted layers of PET.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗