Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

THE TEMPERATURE OF THE COSMIC MICROWAVE BACKGROUND

The Far InfraRed Absolute Spectrophotometer data are independently recalibrated using the Wilkinson Microwave Anisotropy Probe data to obtain a cosmic microwave background (CMB) temperature of 2.7260 +- 0.0013. Measurements of the temperature of the CMB are reviewed. The determination from the measurements from the literature is CMB temperature of 2.72548 +- 0.00057 K.

79 ASTRONOMY AND ASTROPHYSICS↗

Suppression of Deflecting Forces in Planar-Symmetric Dielectric Wakefield Accelerating Structures with Elliptical Bunches

Wakefield based accelerators capable of accelerating gradients two orders of magnitude higher than present accelerators offer a path to compact high energy physics instruments and light sources. However, for high gradient accelerators, beam instabilities driven by commensurately high transverse wakefields limit beam quality. It has been previously theoretically shown that transverse wakefields can be reduced by elliptically shaping the transverse sizes of beams in dielectric structures with planar symmetry. We report here experimental measurements that demonstrate reduced transverse wakefields for elliptical beams in planar symmetric structures which are consistent with theoretical models. Furthermore, these results may enable the design of gigavolt-per-meter gradient wakefield based accelerators that produce and stably accelerate high quality beams.

47 OTHER INSTRUMENTATION↗

Central Solenoid Insert Technical Specification

The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by the Company and ITER. The Fabrication Specifications may reflect some national requirements and regulations that are not fully provided here. This document presents the ITER CSI specifications.

36 MATERIALS SCIENCE↗

Ten Trials at Lower Slobbovia: Searching for Repetitive Electromagnetic and Seismoacoustic Signatures in Explosions

We performed a series of ten explosion tests, each test being a single 10-kg cylinder of Comp-B with a PBXN-9 booster. Eight of the tests were placed 2 m above ground level, one was at ground level, and one was 1 m below ground in a backfilled hole. The explosions were monitored by radio antennas to detect electromagnetic emissions and seismo-acoustic instrumentation. We found that certain aspects of the radiofrequency emission regimes repeated from test to test. Some features showed a systematic variation across tests, which we interpret as the effect of each detonation on the nearby ground. The radio emissions were probably from the high-temperature detonation shock, follow-on combustion, and frictional charging of dirt entrained by the blast. The below-ground test in particular generated an anomalously-high level of RF at both low and high frequencies, presumably due to the large amount of dirt and rock involved. The seismoacoustic observations clearly discriminate the buried shot from the table and surface shots, which appear as a single population. Seismoacoustic waveforms from repeating tests at local distances have highly self-similar waveforms but amplitudes are strongly dependent on atmospheric conditions. We show that we can correct for meteorological effects on amplitude for upward-refracting atmospheres, but that correction for downward-refracting atmospheric profiles requires a coupled correction for topography.

47 OTHER INSTRUMENTATION↗

Muon g-2 Experiment Shimming

The Muon g-2 experiment at Fermilab will use as its primary instrument a 52-foot-wide electromagnet that creates a precise magnetic field. In this video, Fermilab's Brendan Kiburg explains the lengthy process of finely "shimming" that magnetic field into shape.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Small-angle neutron polarimetry apparatus (SANPA): Development at the NIST Center for Neutron Research

Spherical neutron polarimetry directly measures the rotation of the neutron polarization after scattering from materials with magnetic structure. It is an under utilized measurement technique that is capable of measuring all nine elements of the polarization tensor of a material. In this article, we describe our new cryogen-free small-angle neutron polarimetry apparatus and infrastructure at the NIST Center for Neutron Research. The resulting apparatus is capable of continuous operation and is designed for measurements at low temperatures (4–8 K) using niobium Meissner shielding and mu-metal shielding to produce a zero-field (≤1 μT) cooling sample environment.

47 OTHER INSTRUMENTATION↗

Spun optical fibres: A helical structure of linear birefringence or circular birefringence?

An experiment has been proposed, theoretically substantiated and accomplished which has provided conclusive evidence in favour of one of two models for the behaviour of polarised light in optical fibres fabricated by spinning preforms with a high built-in linear birefringence (spun fibres): a helical structure of the built-in linear birefringence axes and circular birefringence. The experiment, carried out with a reflective fibreoptic dual-polarisation interferometer, has shown that the behaviour of polarisation states in spun fibres can be understood in terms of a helical structure of the built-in linear birefringence axes. (optical fibres)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the Fast Scintillation Detector with Programmable High Voltage Adjustment Suitable for Moessbauer Spectroscopy

This work is focused on a development of a compact fast scintillation detector suitable for Moessbauer spectroscopy (low energy X-ray/{gamma}-ray detection) where high counting rates are inevitable. Optimization of this part was necessary for a reliable function, better time resolution and to avoid a detector pulses pile-up effect. The pile-up effect decreases the measurement performance, significantly depends on the source activity and also on the pulse duration. Our new detection unit includes a fast scintillation crystal YAP:Ce, an R6095 photomultiplier tube, a high voltage power supply socket C9028-01 assembly, an AD5252 digital potentiometer with an I2C interface and an AD8000 ultra fast operation preamplifier. The main advantages of this solution lie in a short pulse duration (less than 200 ns), stable operation for high activities, programmable gain of the high voltage supply and compact design in the aluminum housing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Negative Refraction in Time-Varying Strongly Coupled Plasmonic-Antenna–Epsilon-Near-Zero Systems

Time-varying metasurfaces are emerging as a powerful instrument for the dynamical control of the electromagnetic properties of a propagating wave. Here we demonstrate an efficient time-varying metasurface based on plasmonic nano-antennas strongly coupled to an epsilon-near-zero (ENZ) deeply subwavelength film. The plasmonic resonance of the metal resonators strongly interacts with the optical ENZ modes, providing a Rabi level spitting of ~30%. Optical pumping at frequency ω induces a nonlinear polarization oscillating at 2ω responsible for an efficient generation of a phase conjugate and a negative refracted beam with a conversion efficiency that is more than 4 orders of magnitude greater compared to the bare ENZ film. In this work, the introduction of a strongly coupled plasmonic system therefore provides a simple and effective route towards the implementation of ENZ physics at the nanoscale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Policy-Driven Sustainable Saline Drainage Disposal and Forage Production in the Western San Joaquin Valley of California

Environmental policies to address water quality impairments in the San Joaquin River of California have focused on the reduction of salinity and selenium-contaminated subsurface agricultural drainage loads from westside sources. On 31 December 2019, all of the agricultural drainage from a 44,000 ha subarea on the western side of the San Joaquin River basin was curtailed. This policy requires the on-site disposal of all of the agricultural drainage water in perpetuity, except during flooding events, when emergency drainage to the River is sanctioned. The reuse of this saline agricultural drainage water to irrigate forage crops, such as ‘Jose’ tall wheatgrass and alfalfa, in a 2428 ha reuse facility provides an economic return on this pollutant disposal option. Irrigation with brackish water requires careful management to prevent salt accumulation in the crop root zone, which can impact forage yields. The objective of this study was to optimize the sustainability of this reuse facility by maximizing the evaporation potential while achieving cost recovery. This was achieved by assessing the spatial and temporal distribution of the root zone salinity in selected fields of ‘Jose’ tall wheatgrass and alfalfa in the drainage reuse facility, some of which have been irrigated with brackish subsurface drainage water for over fifteen years. Electromagnetic soil surveys using an EM-38 instrument were used to measure the spatial variability of the salinity in the soil profile. The tall wheatgrass fields were irrigated with higher salinity water (1.2–9.3 dS m -1 ) compared to the fields of alfalfa (0.5–6.5 dS m -1 ). Correspondingly, the soil salinity in the tall wheatgrass fields was higher (12.5 dS m -1 –19.3 dS m -1 ) compared to the alfalfa fields (8.97 dS mm -1 –14.4 dS mm -1 ) for the years 2016 and 2017. Better leaching of salts was observed in the fields with a subsurface drainage system installed (13–1 and 13–2). The depth-averaged root zone salinity data sets are being used for the calibration of the transient hydro-salinity computer model CSUID-ID (a one-dimensional version of the Colorado State University Irrigation Drainage Model). This user-friendly decision support tool currently provides a useful framework for the data collection needed to make credible, field-scale salinity budgets. In time, it will provide guidance for appropriate leaching requirements and potential blending decisions for sustainable forage production. This paper shows the tie between environmental drainage policy and the role of local governance in the development of sustainable irrigation practices, and how well-directed collaborative field research can guide future resource management.

54 ENVIRONMENTAL SCIENCES↗

SOURCE DETECTION IN INTERFEROMETRIC VISIBILITY DATA. I. FUNDAMENTAL ESTIMATION LIMITS

Transient radio signals of astrophysical origin present an avenue for studying the dynamic universe. With the next generation of radio interferometers being planned and built, there is great potential for detecting and studying large samples of radio transients. Currently used image-based techniques for detecting radio sources have not been demonstrated to be optimal, and there is a need for development of more sophisticated algorithms and methodology for comparing different detection techniques. A visibility-space detector benefits from our good understanding of visibility-space noise properties and does not suffer from the image artifacts and need for deconvolution in image-space detectors. In this paper, we propose a method for designing optimal source detectors using visibility data, building on statistical decision theory. The approach is substantially different to conventional radio astronomy source detection. Optimal detection requires an accurate model for the data, and we present a realistic model for the likelihood function of radio interferometric data, including the effects of calibration, signal confusion, and atmospheric phase fluctuations. As part of this process, we derive fundamental limits on the calibration of an interferometric array, including the case where many relatively weak 'in-beam' calibrators are used. These limits are then applied, along with a model for atmospheric phase fluctuations, to determine the limits on measuring source position, flux density, and spectral index, in the general case. We then present an optimal visibility-space detector using realistic models for an interferometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-power microwave LDMOS transistors for wireless data transmission technologies (Review)

The fields of the application, structure, fabrication, and packaging technology of high-power microwave LDMOS transistors and the main advantages of these devices were analyzed. Basic physical parameters and some technology factors were matched for optimum device operation. Solid-state microwave electronics has been actively developed for the last 10-15 years. Simultaneously with improvement of old devices, new devices and structures are actively being adopted and developed and new semiconductor materials are being commercialized. Microwave LDMOS technology is in demand in such fields as avionics, civil and military radars, repeaters, base stations of cellular communication systems, television and broadcasting transmitters, and transceivers for high-speed wireless computer networks (promising Wi-Fi and Wi-Max standards).

36 MATERIALS SCIENCE↗

Level monitoring system with pulsating sensor—Application to online level monitoring of dashpots in a fast breeder reactor

An innovative continuous type liquid level monitoring system constructed by using a new class of sensor, viz., pulsating sensor, is presented. This device is of industrial grade and it is exclusively used for level monitoring of any non conducting liquid. This instrument of unique design is suitable for high resolution online monitoring of oil level in dashpots of a sodium-cooled fast breeder reactor. The sensing probe is of capacitance type robust probe consisting of a number of rectangular mirror polished stainless steel (SS-304) plates separated with uniform gaps. The performance of this novel instrument has been thoroughly investigated. The precision, sensitivity, response time, and the lowest detection limit in measurement using this device are <0.01 mm, ∼100 Hz/mm, ∼1 s, and ∼0.03 mm, respectively. The influence of temperature on liquid level is studied and the temperature compensation is provided in the instrument. The instrument qualified all recommended tests, such as environmental, electromagnetic interference and electromagnetic compatibility, and seismic tests prior to its deployment in nuclear reactor. With the evolution of this level measurement approach, it is possible to provide dashpot oil level sensors in fast breeder reactor for the first time for continuous measurement of oil level in dashpots of Control and Safety Rod Drive Mechanism during reactor operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strangeness Physics with CLAS at Jefferson Lab

A brief overview of strangeness physics with the CLAS detector at JLab is given, mainly covering the domain of nucleon resonances. Several excited states predicted by the symmetric constituent quark model may have signiffcant couplings to the K+ or K0 channels. I will discuss data that are relevant in the search for such states in the strangeness channel, and give an outlook on the future prospects of the N* program at JLab with electromagnetic probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interlaced linear array sampling technique for electromagnetic wave imaging

An arrangement of receivers and transmitters used in wideband holographic imaging using a reduced number of physical antenna elements compared to established techniques and systems. At least one of the receivers is configured to receive the reflected signal from three or more of transmitters, and at least one transmitter is configured to transmit a signal to an object, the reflection of which will be received by at least three receivers. The improved arrays are easily incorporated into existing microwave and millimeter wave holographic imaging equipment utilizing the existing mechanical features of this equipment, as well as the existing wideband holographic imaging algorithms and electronics for constructing images.

47 OTHER INSTRUMENTATION↗

MAINTAINING HIGH RESOLUTION MASS SPECTROMETRY CAPABILITIES FOR NATIONAL NUCLEAR SECURITY ADMINISTRATION APPLICATIONS

The Department of Energy (DOE) National Nuclear Security Administration (NNSA) has a specialized need for analyzing low mass gas species at very high resolutions. The currently preferred analytical method is electromagnetic sector mass spectrometry. This method allows the NNSA Nuclear Security Enterprise (NSE) to resolve species of similar masses down to acceptable minimum detection limits (MDLs). Some examples of these similar masses are helium-4/deuterium and carbon monoxide/nitrogen. Through the 1980s and 1990s, there were two vendors who supplied and supported these instruments. However, with declining procurements and down turns in the economy, the supply of instruments, service and spare parts from these vendors has become less available, and in some cases, nonexistent. The largest NSE user of this capability is the Savannah River Site (SRS), located near Aiken, South Carolina. The Research and Development Engineering (R&DE) Group in the Savannah River National Laboratory (SRNL) investigated the areas of instrument support that were needed to extend the life cycle of these aging instruments. Their conclusions, as to the focus areas of electromagnetic sector mass spectrometers to address, in order of priority, were electronics, software and hardware. Over the past 3-5 years, the R&DE Group has designed state of the art electronics and software that will allow high resolution legacy mass spectrometers, critical to the NNSA mission, to be operated for the foreseeable future. The funding support for this effort has been from several sources, including the SRS Defense Programs, NNSA Readiness Campaign, Pantex Plant and Sandia National Laboratory. To date, electronics systems have been upgraded on one development system at SRNL, two production systems at Pantex and one production system at Sandia National Laboratory. An NSE working group meets periodically to review strategies going forward. The R&DE Group has also applied their work to the electronics for a Thermal Ionization Mass Spectrometer (TIMS) instrument, which applies a similar mass spectrometric technology for resolving high mass isotopes, such as plutonium and uranium. Due to non-compete clauses for DOE, all work has been performed and applied to instruments which are obsolete and are no longer supported by the original vendor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARCADE 2 MEASUREMENT OF THE ABSOLUTE SKY BRIGHTNESS AT 3-90 GHz

The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming optics and the sky. An external blackbody calibrator provides an in situ reference. Systematic errors were greatly reduced by using differential radiometers and cooling all critical components to physical temperatures approximating the cosmic microwave background (CMB) temperature. A linear model is used to compare the output of each radiometer to a set of thermometers on the instrument. Small corrections are made for the residual emission from the flight train, balloon, atmosphere, and foreground Galactic emission. The ARCADE 2 data alone show an excess radio rise of 54 {+-} 6 mK at 3.3 GHz in addition to a CMB temperature of 2.731 {+-} 0.004 K. Combining the ARCADE 2 data with data from the literature shows an excess power-law spectrum of T = 24.1 {+-} 2.1 (K) ({nu}/{nu}{sub 0}){sup -2.599{+-}0.036} from 22 MHz to 10 GHz ({nu}{sub 0} = 310 MHz) in addition to a CMB temperature of 2.725 {+-} 0.001 K.

79 ASTRONOMY AND ASTROPHYSICS↗