Special report: Occlusive cuff controller

A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.

Baker, J. T.

Influences of physical training on the heart of dogs

To investigate the effects of physical training on cardiac dimensions and function, eight dogs were exercised for 12 weeks by treadmill running 1 hour/day, 5 days/week. Five dogs were confined in cages as controls for an 8-week period. Heart rates were monitored by telemetry during rest and exercise. Maximum QRS spatial magnitudes were calculated from records of McFee lead electrocardiograms. Left ventricular end-diastolic dimensions were determined radiographically by the bead and clip technique. Training produced statistically significant decreases in heart rate at rest and at a standard work load of 6.1 mph on a level treadmill and statistically significant increases in work load at a standard heart rate of 194 beats/min. Improvements were rapid during the first 4 weeks of training but gradual during the remaining 8 weeks. Training caused small but statistically significant increases in left ventricular end-diastolic wall thickness, estimated left ventricular mass, and maximum QRS spatial magnitude.

Wyatt, H. L.

Animal exposure during burn tests

An animal exposure test system has been designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consists of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram and respiration. The ECG and respiration sensors are located in a belt placed around the torso of the subject, electrode wires forming an umbilical to a connector in the top of the compartment. A cable extends from the connector to the power supply and signal conditioning electronics. These are connected to a dual-beam oscilloscope for real time monitoring and a magnetic tape recorder having three or more channels. Endpoints observed are bradycardia, cardiac arrhythmias, changes in respiratory pattern, respiratory arrest and cardiac arrest. The ECG record also appears to be a good method of monitoring animal activity as indicated by an increase in EMG noise superimposed on the record during increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases.

Gaume, J. G.

Emergency-vehicle VHF antenna

Helical VHF antenna mounts on roof of moving vehicle to communicate with distant stations via earth satellites. Antenna requires no pointing and can provide two-way communication while vehicle moves at high speed. Device has proved extremely successful in electrocardiogram transmission tests between medical services vehicle and hospital emergency room.

Anderson, R. E.

Vectorcardiographic results from Skylab medical experiment M092: Lower body negative pressure

Electrocardiographic interval changes suggesting effects of increased vagal tone were observed early in some Gemini crewmembers. Preflight versus postflight amplitude differences appeared in electrocardiograms of several of the early Apollo crewmembers. In preflight and postflight crew evaluations of the last three Apollo flights, quantitative postflight vectorcardiographic changes were for the first time determined in American space crews. Changes not considered related to heart rate were mainly those of increased P and QRS vector magnitudes and orientation shifts. But since most of these postflight findings resembled those observed with the orthostatic stress of lower body negative pressure, it was inferred then that upon their return from space, these Apollo astronauts exhibited exaggerated responses to orthostasis in the vectorcardiogram as well as in measures of cardiovascular hemodynamics.

Hoffler, G. W.

Vectorcardiographic changes during extended space flight (M093): Observations at rest and during exercise

The objectives of Skylab Experiment M093 were to measure electrocardiographic signals during space flight, to elucidate the electrophysiological basis for the changes observed, and to assess the effect of the change on the human cardiovascular system. Vectorcardiographic methods were used to quantitate changes, standardize data collection, and to facilitate reduction and statistical analysis of data. Since the Skylab missions provided a unique opportunity to study the effects of prolonged weightlessness on human subjects, an effort was made to construct a data base that contained measurements taken with precision and in adequate number to enable conclusions to be made with a high degree of confidence. Standardized exercise loads were incorporated into the experiment protocol to increase the sensitivity of the electrocardiogram for effects of deconditioning and to detect susceptability for arrhythmias.

Smith, R. F.

Skylab hardware report operational bioinstrumentation system

The Skylab Operational Bioinstrumentation System is a personal, individually adjustable biomedical system designed to monitor the basic physiological functions of each suited crewman during specified periods of a manned space mission. The basic physiological functions of this system include electrocardiogram, respiration by impedance pneumogram, body temperature, cardiotachometer, and subject identification. The Operational Bioinstrumentation System was scheduled to monitor each crewman during launch, extravehicular activities, suited intravehicular experiments, and undocking and return.

Luczkowski, S.

Heart rate-left ventricular ejection time relations - Variations during postural change and cardiovascular challenges

Experiments were conducted on healthy human subjects to determine HR-LVET (Heart Rate-Left Ventricular Ejection Time) regression relations in different postures, including tilt, and during isometric exercise. The subjects were tested in the resting state in supine and sitting positions, during isometric handgrip in supine and sitting positions and during 70 deg headup tilt. The recordings included a bipolar electrocardiogram and a right external carotid pulse curve. Comparison of the HR-LVET relation for the conditions under analysis revealed differences among the respective regression equations, which can be explained by the well-established differences in stroke volume and ejection rate among these states. These differences appear to account for the fact that under conditions in which stroke volume variations should be the major determinant, slopes will be similar but intercepts will vary. Since substantial differences among intercepts are observed, caution should be exercised whenever the intercept factor is used to predict LVET for HR.

Lance, V. Q.

Hybrid ECG signal conditioner

Circuit with high common-mode rejection has ability to filter and amplify accepted analog electrocardiogram (ECG) signals of varying amplitude, shape, and polarity. In addition, low power circuit develops standardized pulses that can be counted and averaged by heart/breath rate processor.

Rinard, G. A.

Basic results of the medical research conducted during the flight of two crews on the Salyut-5 orbital station

The study of the effect of space factors, especially weightlessness, on man, taking into account prophylactic measures and devices to counteract that effect was part of the program for two flights on the Salyut 5 orbital station. Information from the equipment on board was transmitted telemetrically including: an electrocardiogram; a sphygmogram of carotid and femoral arteries; a kinetocardiogram; a tacho-oscillogram of the humeral artery, perimetric oscillations of the femur, venous pulse and pressure in the jugular veins, vital capacity of the lungs, respiration rate and lung ventilation. Stress factors, metabolism, biological and bacteriological and other tests were included. A comparison was made between these data and pre- and postflight test result.

Source record

Design and performance of heart assist or artificial heart control systems

The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.

Webb, J. A., Jr.

Animal Exposure During Burn Tests

An animal exposure test system (AETS) was designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consisted of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram (ECG) and respiration. Cage temperature is measured by a thermistor located in the upper portion of the rat compartment. Animal activity is monitored by the ECG and the records indicate an increase in EMG (electromyograph) noise super-imposed by the increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases and specific events occurring during the test. The AETS was shown to be a useful tool in screening materials for the relative toxicity of their outgassing products during pyrolysis and combustion.

Gaume, J. G.

A sequential method for spline approximation with variable knots

In this paper we describe a method for approximating a waveform by a spline. The method is quite efficient, as the data are processed sequentially. The basis of the approach is to view the approximation problem as a question of estimation of a polynomial in noise, with the possibility of abrupt changes in the highest derivative. This allows us to bring several powerful statistical signal processing tools into play. We also present some initial results on the application of our technique to the processing of electrocardiograms, where the knot locations themselves may be some of the most important pieces of diagnostic information.

Mier Muth, A. M.

Microprocessor-based cardiotachometer

Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.

Crosier, W. G.

Pocket ECG electrode

A low noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free ranging subject is described. The electrode comprises a pocket shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member, remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

Lund, G. F.

Subcutaneous electrode structure

A subcutaneous electrode structure suitable for a chronic implant and for taking a low noise electrocardiogram of an active animal, comprises a thin inflexible, smooth disc of stainless steel having a diameter as of 5 to 30 mm, which is sutured in place to the animal being monitored. The disc electrode includes a radially directed slot extending in from the periphery of the disc for approximately 1/3 of the diameter. Electrical connection is made to the disc by means of a flexible lead wire that extends longitudinally of the slot and is woven through apertures in the disc and held at the terminal end by means of a spot welded tab. Within the slot, an electrically insulative sleeve, such as silicone rubber, is placed over the wire. The wire with the sleeve mounted thereon is captured in the plane of the disc and within the slot by means of crimping tabs extending laterally of the slot and over the insulative wire. The marginal lip of the slot area is apertured and an electrically insulative potting material such as silicone rubber, is potted in place overlaying the wire slot region and through the apertures.

Lund, G. F.

Cabin fire simulator lavatory tests

All tests were conducted in the Douglas Cabin Fire Simulator under in-flight ventilation conditions. All tests were allowed to continue for a period of one hour. Data obtained during these tests included: heat flux and temperatures of the lavatory; cabin temperature variations; gas analyses for O2, CO2, CO, HF, HC1, and HCN; respiration and electrocardiogram data on instrumented animal subjects (rats) exposed in the cabin; and color motion pictures. All tests resulted in a survivable cabin condition; however, occupants of the cabin would have been subjected to noxious fumes.

Schutter, K. J.

Low-Noise Implantable Electrode

New implantable electrocardiogram electrode much less sensitive than previous designs to spurious biological potentials. Designed in novel "pocket" configuration, new electrode is intended as sensor for radiotelemetry of biological parameters in experiments on unrestrained subjects. Electrode is esentially squashed cylinder that admits body fluid into interior. Cylinder and electrical lead are made of stainless steel. Spot welding and crimping are used for assembly, rather than soldering.

Lund, G. F.