Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRICAL FAULTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A study of fault injection in multichannel spacecraft power systems

NASA/Marshall Space Flight Center proposes to implement fault injection into an electrical power system breadboard to study the reactions of the various control elements of this breadboard. Among the elements to be studied are the remote power controllers, the algorithms in the control computers, and the artificially intelligent control programs resident in this breadboard. To this end, a study of electrical power is being performed to yield a list of the most common power system faults. The results of this study are being applied to a multichannel high-voltage DC spacecraft power system called the Large Autonomous Spacecraft Electrical Power System Breadboard. Some of the reactions of the breadboard to some of the faults which have been encountered are presented along with the results of this study.

Dugal-Whitehead, Norma R.↗

Flight elements subpanel introduction and overview

Major objectives, milestones, key contacts, technology issues, accomplishments, and candidate programs are outlined. Topics addressed include: advanced avionics systems architectures; advanced information processing; avionics concepts; integrated Global Positioning System/guidance, navigation, and command concepts; advanced communication and telemetry; display and control concepts; advanced sensors and instrumentation; fault detection and fault management; advanced electric power, distribution, and control; EMA/power systems; and in-flight crew training. This presentation is represented by viewgraphs only.

Sollock, Paul E.↗

Image-Based Localization of Ultraviolet Corona

Systems and methods for identifying a fault in an electrical distribution system may include capturing an image of a corona event associated with a component of the electrical distribution system and processing the image of the corona event to identify the center and boundary of the corona event. An overlay for display with the image of the corona event may be generated, where the overlay identifying at least a center of the corona event and may be displayed to a user via a user interface device. In some cases, an unmanned aerial vehicle may comprise one or more image sensors capable of capturing the image of the corona event and communicate the images to a remote device for processing and display to the user. The image captured by the image sensors may include an ultraviolet image, a visible spectrum image, an infrared image, or a combination of image types.

Moore, Andrew J.↗

Flight Simulator Demonstration and Certification Implications of Powertrain Failure Mitigation in a Partial Turboelectric Aircraft

The Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC ABL) is a concept aircraft with a partial turboelectric powertrain. The complexity and integrated nature of the partial turboelectric powertrain architecture presents failure modes and hazards not found in conventional aircraft propulsion designs. Previously, various electrical and mechanical faults and associated recovery modes were demonstrated in a dynamic model of the powertrain. It was shown that certain faults were catastrophic without recovery logic, due specifically to the interaction of the subsystems. However, in each case, the logic, known as a reversionary control mode, enabled continued operation with assumed sufficient thrust to maintain safe flight. The current work evaluates the powertrain faults and recovery strategies using a full aircraft model in a piloted flight simulator, and places it in the context of current regulatory practice. Faults initiated in flight were successfully mitigated, with the accommodated aircraft subsequently evaluated against certification requirements for three-engine aircraft, which were shown to be appropriate for the STARC-ABL configuration.

STARC-ABL↗

Flight Simulator Demonstration and Certification Implications of Powertrain Failure Mitigation in a Partial Turboelectric Aircraft

The Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC ABL) is a concept aircraft with a partial turboelectric powertrain. The complexity and integrated nature of the partial turboelectric powertrain architecture presents failure modes and hazards not found in conventional aircraft propulsion designs. Previously, various electrical and mechanical faults and associated recovery modes were demonstrated in a dynamic model of the powertrain. It was shown that certain faults were catastrophic without recovery logic, due specifically to the interaction of the subsystems. However, in each case, the logic, known as a reversionary control mode, enabled continued operation with assumed sufficient thrust to maintain safe flight. The current work evaluates the powertrain faults and recovery strategies using a full aircraft model in a piloted flight simulator, and places it in the context of current regulatory practice. Faults initiated in flight were successfully mitigated, with the accommodated aircraft subsequently evaluated against certification requirements for three-engine aircraft, which were shown to be appropriate for the STARC-ABL configuration.

STARC-ABL↗

Flight Simulator Demonstration and Certification Implications of Powertrain Failure Mitigation in a Partial Turboelectric Aircraft

The Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC ABL) is a concept aircraft with a partial turboelectric powertrain. The complexity and integrated nature of the partial turboelectric powertrain architecture presents failure modes and hazards not found in conventional aircraft propulsion designs. Previously, various electrical and mechanical faults and associated recovery modes were demonstrated in a dynamic model of the powertrain. It was shown that certain faults were catastrophic without recovery logic, due specifically to the interaction of the subsystems. However, in each case, the logic, known as a reversionary control mode, enabled continued operation with assumed sufficient thrust to maintain safe flight. The current work evaluates the powertrain faults and recovery strategies using a full aircraft model in a piloted flight simulator, and places it in the context of current regulatory practice. Faults initiated in flight were successfully mitigated, with the accommodated aircraft subsequently evaluated against certification requirements for three-engine aircraft, which were shown to be appropriate for the STARC-ABL configuration.

certification↗

Piloted Evaluation of a Fault Recovery System for an Aircraft with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple tightly coupled subsystems, making them much more complex than traditional aircraft propulsion systems, both in terms of integration and control. Electrification enables aircraft to have multiple distributed thrust-producing fans that the flight control system can utilize for enhanced maneuverability, further increasing the control complexity. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept aircraft that leverages this technology. SUSAN is a series/parallel partial hybrid electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed, tested, validated, and implemented. This paper describes a piloted evaluation of such an algorithm in scenarios with multiple fan failures, performed in a flight simulator, demonstrating failure recovery and continued safe operation up to the limits of the powertrain. These scenarios are subsequently related to certification requirements.

Electrified Aircraft Propulsion↗

Piloted Evaluation of a Fault Recovery System for an Aircraft with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple tightly coupled subsystems, making them much more complex than traditional aircraft propulsion systems, both in terms of integration and control. Electrification enables aircraft to have multiple distributed thrust-producing fans that the flight control system can utilize for enhanced maneuverability, further increasing the control complexity. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept aircraft that leverages this technology. SUSAN is a series/parallel partial hybrid electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed, tested, validated, and implemented. This paper describes a piloted evaluation of such an algorithm in scenarios with multiple fan failures, performed in a flight simulator, demonstrating failure recovery and continued safe operation up to the limits of the powertrain. These scenarios are subsequently related to certification requirements.

Electrified Aircraft Propulsion↗

Piloted Evaluation of a Fault Recovery System for an Aircraft with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple tightly coupled subsystems, making them much more complex than traditional aircraft propulsion systems, both in terms of integration and control. Electrification enables aircraft to have multiple distributed thrust-producing fans that the flight control system can utilize for enhanced maneuverability, further increasing the control complexity. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept aircraft that leverages this technology. SUSAN is a series/parallel partial hybrid electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed, tested, validated, and implemented. This paper describes a piloted evaluation of such an algorithm in scenarios with multiple fan failures, performed in a flight simulator, demonstrating failure recovery and continued safe operation up to the limits of the powertrain. These scenarios are subsequently related to certification requirements.

Electrified Aircraft Propulsion↗

Functional requirements for an intelligent RPC

An intelligent remote power controller (RPC) based on microcomputer technology can implement advanced functions for the accurate and secure detection of all types of faults on a spaceborne electrical distribution system. The intelligent RPC will implement conventional protection functions such as overcurrent, under-voltage, and ground fault protection. Advanced functions for the detection of soft faults, which cannot presently be detected, can also be implemented. Adaptive overcurrent protection changes overcurrent settings based on connected load. Incipient and high-impedance fault detection provides early detection of arcing conditions to prevent fires, and to clear and reconfigure circuits before soft faults progress to a hard-fault condition. Power electronics techniques can be used to implement fault current limiting to prevent voltage dips during hard faults. It is concluded that these techniques will enhance the overall safety and reliability of the distribution system.

Aucoin, B. M.↗

An autonomous fault detection, isolation, and recovery system for a 20-kHz electric power distribution test bed

Future space explorations will require long term human presence in space. Space environments that provide working and living quarters for manned missions are becoming increasingly larger and more sophisticated. Monitor and control of the space environment subsystems by expert system software, which emulate human reasoning processes, could maintain the health of the subsystems and help reduce the human workload. The autonomous power expert (APEX) system was developed to emulate a human expert's reasoning processes used to diagnose fault conditions in the domain of space power distribution. APEX is a fault detection, isolation, and recovery (FDIR) system, capable of autonomous monitoring and control of the power distribution system. APEX consists of a knowledge base, a data base, an inference engine, and various support and interface software. APEX provides the user with an easy-to-use interactive interface. When a fault is detected, APEX will inform the user of the detection. The user can direct APEX to isolate the probable cause of the fault. Once a fault has been isolated, the user can ask APEX to justify its fault isolation and to recommend actions to correct the fault. APEX implementation and capabilities are discussed.

Quinn, Todd M.↗

Electrical Engineering Medium Voltage Protection and Coordination

This presentation covers the basics of the medium voltage electrical system on the Kennedy Space Center. The material will include the process of selective coordination between protective devices and the analysis of a fault that occurred in the electrical system. I will discuss the most common causes of faults found and how the system reacts to the faults at different locations in the subsystem. Explain the importance of the sensitivity and coordination between the devices to protect the equipment it is supplying.

Wessner, Jason R.↗

The impact of defects on the photovoltaic potential of RTR silicon ribbon

Silicon ribbon grown at a high rate by the ribbon-to-ribbon (RTR) method contains a variety of defects and can exhibit an unusual dendritic morphology. This paper is a study of the effect of the defect structure and dendritic morphology on the photovoltaic potential of RTR ribbon. Defects found in RTR ribbon include grain boundaries, twin planes, stacking faults and dislocations. The electrical activity of these defects is investigated by measuring the diffusion length in the ribbon; by fabricating small area diodes on the ribbon and evaluating their photoresponse; and by using a scanning electron microscope in the electron beam induced current mode. It is concluded that although grain boundaries serve very effectively as recombination centers, they do not occur frequently enough in RTR ribbons to significantly affect the generation current. Dislocation densities up to 1,000,000/sq cm can be tolerated without strongly reducing the photoresponse. Similarly, linear boundaries such as twin planes or stacking faults do not affect the cell performance up to densities of 1000/sq cm.

Baghdadi, A.↗

Detectors Ensure Function, Safety of Aircraft Wiring

Pedro Medelius waited patiently in his lab at Kennedy Space Center. He had just received word that a colleague was bringing over a cable from a Space Shuttle solid rocket booster to test Medelius new invention. Medelius was calm until his colleague arrived, with about 30 other people. "Talk about testing under pressure," says Medelius. "There were people there from the Navy, the Air Force, and the Federal Aviation Administration." After the group s arrival, Medelius took a deep breath and connected his Standing Wave Reflectometer (SWR) to the cable. He wiggled the cable around, and the display showed a fault (a short or open circuit in wire) about an inch and a half inside the connector on the cable. His colleague questioned the results, because he had already checked that area on the cable. Medelius used the SWR to check again but got the same result. "That is when we took the cable apart and looked inside," Medelius says. "Lo and behold, that was exactly where the fault was." The impetus for Medelius new wire inspection technology came about in 1999 when one of the space shuttles lost power due to a fault somewhere in its more than 200 miles of electrical wiring. "The backup circuit was activated and prevented a major dysfunction, but nevertheless, there was a problem with the wiring," Medelius describes. Even though technicians used a device called a multimeter to measure the electrical current to find which wire had a fault, it could not pinpoint exactly where on the wire the fault was located. For that, technicians had to visually inspect the wire. "Sometimes they would have to remove the whole wire assembly and visually inspect every single wire. It was a very tedious operation because the wires are behind cabinets. They go all over the place in the shuttle," says Medelius. "NASA needed an instrument capable of telling them exactly where the faults were occurring." To meet NASA s needs for a highly precise device to inspect electrical power bundles, wires, and connectors, Medelius devised the SWR. "It came down to what was affected when a wire is short circuited or opened," he says. "We worked out a few equations based on physical principles." The SWR proved very sensitive, and the technology was patented.

Source record↗

Atmosphere revitalization in the space station prototype.

The atmosphere revitalization group (ARG) for the space station prototype (SSP) environmental/thermal control and life support system (ETC/LSS) has been designed to meet a comprehensive set of requirements and constraints for a flight type mission. Design definition is for a modular vehicle temperature and humidity control subsystem, contaminant control equipment, a hydrogen depolarized cell CO2 concentrator, a water electrolysis oxygen generation subsystem, CO2 reduction equipment, and a pressure and composition control subsystem. Performance requirements are for support of a crew of six. Realistic leakage rates and metabolic activity cycles, cabin temperature selectability, and controlled cabin relative humidities are specified for the design. Operational aspects of the subsystem are discussed with emphasis given to the influence of a 180-day, maintainable requirement on system design. Consideration of flight vehicle type packaging, in flight maintenance, data management systems interface and fault detection capability, and electrical supply constraints is covered.

Trusch, R. B.↗

Electrical safety requirements: Implications for the module designer

Commercial photovoltaic array installations, which include residential and intermediate applications, are subject to building and electrical codes and to product safety standards. The National Electrical Code (NEC) Article 690, titled Solar Photovoltaic Systems, contains provisions defining acceptable levels of system safety and emphasizes the system design and its installation. The Underwriters Laboratories, Inc. (UL), document titled: Proposed First Edition of the Standard for Flat Plate Photovoltaic Modules and Panels, UL-1703, identifies module and panel construction requirements that ensure product safety. Together these documents describe requirements intended to minimize hazards such as shock and fire. Although initial focus of these requirements is on single crystal silicon modules, they are generic in nature, and are equally applicable to high voltage ( 30 Vdc), multikilowatt, thin film systems. A major safety concern is insulation breakdown within the module or array wiring system, or discontinuities within the electrical conductors. These failures can result in ground faults, in circuit arcs, or exposure to hazardous electrical parts. Safeguards are discussed.

Sugimura, R. S.↗

Sensor-based fault diagnosis in a flight expert system

A prototype of a knowledge-based flight expert system (FLES) has been developed to assist airplane pilots in monitoring, analyzing, and diagnosing faults and to provide support in reducing the pilot's own mistakes. A sensor simulation model has been developed to provide FLES with the airplane status information during the diagnostic process. The simulator is based partly on the Advanced Concept System (ACS), a future-generation airplane, and partly on the Boeing 737, an existing airplane. The architecture of FLES contains several subsystems. One of the major subsystems performs fault diagnosis in the electrical system of the ACS. This paper describes the mechanism and functionality of the automatic diagnosis performed in this expert system.

Ali, M.↗