Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ECF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Distribution of Infiltration in the 216-U-10 and 216-B-3 Pond Systems 1944-1997

A modeling system to simulate fate and transport of contaminant plumes in groundwater beneath the Central Plateau to support the Cumulative Impact Evaluation (CIE) and Composite Analysis (CA) is being developed. The CIE will evaluate the cumulative effect of multiple Central Plateau radiological and chemical sources on groundwater quality (DOE/RL-2018-69, Cumulative Impact Evaluation Technical Approach Document ). This will enable cleanup decisions to be evaluated in the context of all Central Plateau waste sites and existing groundwater conditions. The CA evaluates the cumulative effect of all sources of radioactive materials on radiological dose to future members of the public (DOE/RL-2018-60, Annual Status Report (FY 2018): Composite Analysis of Low Level Waste Disposal in the Central Plateau of the Hanford Site ). Fate and transport modeling will be used to forecast future groundwater concentrations for both the CIE and CA. The CIE/CA subsurface modeling system is divided into source (inventory), vadose zone, and saturated zone facets. Source inventory is a necessary input to the vadose zone facet, and releases from the vadose zone to groundwater are inputs to the saturated zone facet. The vadose zone facet simulates historical and future releases from the vadose zone to groundwater for both liquid waste and solid waste disposal sites. Effluent release volumes and radionuclide inventory estimates for liquid waste sites are contained in ECFHANFORD- 17-0079, Hanford Soil Inventory Model (SIM-v2) Calculated Radionuclide Inventory of Direct Liquid Discharges to Soil in the Hanford Site’s 200 Areas , herein referred to as SIM-v2. The liquid waste sites in SIM-v2 include the 216-B-3 Pond near 200 East Area and the 216-U-10 Pond in 200 West Area. The 216-B-3 Pond system consisted of a main pond and 3 expansion lobes that were operational during overlapping time periods. It also included influent ditches, but these are not listed as liquid waste sources in SIM-v2 and are not included in the CIE/CA modeling. The total effluent volume released to the pond system was measured, but the partitioning of this volume to the various expansion lobes was not determined and is not accounted for in SIM-v2. Regarding the 216-U-10 Pond, it received water from several influent ditches. The pond and the influent ditches are listed as liquid waste sites in SIM-v2 and are included as sources in the CIE/CA modeling. Because water in the ditches flowed into the pond, only a portion of the effluent volumes and contaminant inventories assigned to the ditches in SIM-v2 infiltrated from the ditches. Thus, partitioning of infiltration and contaminant inventories between the ditches and the pond is not fully accounted for in SIM-v2. Further, some of the water in the 216-U-10 Pond entered overflow ditches and the amount of this overflow was not recorded and is not accounted for in SIM-v2. Thus, the purpose of this Environmental Calculation File (ECF) is to partition the infiltration of wastewater and contaminant inventory between the main pond and each expansion lobe of the 216-B-3 Pond system, and to partition the infiltration of wastewater and contaminant inventory between the ditches and pond of the 216-U-10 Pond system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Base Case

In order to meet the requirements of U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, a composite analysis (CA) must be completed for the Central Plateau at the Hanford Site. The updated Hanford Site CA requires estimates of fate and transport of radionuclides in the groundwater from multiple sources within and downgradient of the Central Plateau. Numerical simulations using the MT3D-MST computer code were conducted to evaluate the fate and transport of existing distributions of 16 radionuclides as identified in CP-62184, Hanford Site Composite Analysis: Radionuclide Selection for Groundwater Pathway Evaluation: tritium (H-3), carbon-14 (C-14), chloride- 36 (Cl-36), strontium-90 (Sr-90), technetium-99 (Tc-99), rhenium-187 (Re-187), radium-226 (Ra-226), thorium-230 (Th-230), uranium-232 (U-232), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), neptunium-237 (Np-237), and uranium-238 (U- 238). This document details the application of the P2R Model version 8.3 to predict the fate and transport of contaminants in groundwater on the Central Plateau for the 10,052 year simulation to support the CA. The simulation of fate and transport of contaminants reported in this environmental calculation file (ECF) will support dose predictions as part of the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau to River Groundwater Model (P2R Model) is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by CH2M HILL Plateau Remediation Company at the Hanford Site in Washington State. Figure 1-1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the Composite Analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3, documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation is to describe the application of the hydraulic property fields and recharge parameters documented in ECF-HANFORD-20-0027, Null Space Monte Carlo Evaluation of the Plateau to River Model, to the CA flow and fate and transport simulation results to quantify the uncertainty in the simulated results due to input parameter selection. Use of numerical groundwater models is always accompanied with uncertainty in the results produced by a model because models are approximations of reality. Thus, by definition, models lack the detail to fully represent observed behavior. Use of numerical techniques, such as a NSMC analysis, can help in identifying and quantifying the potential uncertainties associated with a numerical model such as the P2R Model. The result of NSCM analysis is a set of F&T simulations that provide an estimate of the range of possible outcomes that are used to quantify the uncertainty in simulated concentrations produced using the base case simulations. The simulated concentrations from all simulations will support calculation of the uncertainty of the total dose calculated in a separate calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distribution of Infiltration in the 216-U-10, 216-B-3 Pond, and 216-T-4 Pond Systems 1944-1997

A modeling system to simulate fate and transport of contaminant plumes in groundwater beneath the Central Plateau to support the Cumulative Impact Evaluation (CIE) and Composite Analysis (CA) is being developed. The CIE will evaluate the cumulative effect of multiple Central Plateau radiological and chemical sources on groundwater quality. This will enable cleanup decisions to be evaluated in the context of all Central Plateau waste sites and existing groundwater conditions. The purpose of this Environmental Calculation File (ECF) is to partition the infiltration of wastewater and contaminant inventory between the main pond and each expansion lobe of the 216-B-3 Pond system, and to partition the infiltration of wastewater and contaminant inventory between the ditches and ponds of the 216-U-10 Pond and 216-T-4 Pond systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

200-IA-1 Operable Unit Ecological Risk Screen

The purpose of this environmental calculation file (ECF) is to document the assumptions, inputs, methodology, equations, and results of a screening level ecological risk assessment (SLERA) conducted for eight of 12 representative waste sites within the newly formed 200 IA-1 Operable Unit (OU); the remaining four waste sites lacked soil data within the shallow vadose zone and were not further evaluated. The SLERA was conducted to evaluate ecological receptor exposure and potential risk using soil data for radionuclides and nonradionuclides occurring within the shallow vadose zone (0 to 15 ft) soil of the OU. The representative Hanford ecological receptors evaluated are: plants, soil invertebrates, California quail (Callipepla californica), Meadowlark (Sturnella neglecta), Killdeer (Charadrius vociferus), Red-tailed hawk (Buteo jamaicensis), Great Basin pocket mouse (Perognathus parvus), Deer mouse (Peromyscus maniculatus), Grasshopper mouse (Onychomys leucogaster), and badger (Taxidea taxus). During the SLERA, detected soil sample results from the shallow vadose zone were used to calculate Hazard Quotients (HQs) for nonradionuclides and Sum of Fractions (SOF) for radionuclides. The results of this SLERA support the preparation of DOE/RL-2020-51, 200-IA-1 Operable Unit Focused Feasibility Study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of 200-IA-1 Operable Unit Soil Concentrations to Preliminary Remediation Goals Protective of Groundwater

This environmental calculation file (ECF) documents the methodology used to determine if current site conditions for the representative waste sites assigned to the 200-IA-1 Operable Unit (OU) based on available sample results are greater than the 200 East or 200 West unit-length preliminary remediation goals (PRGs) for the protection of groundwater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Inventory Sensitivity Case

The Plateau to River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation file (ECF) is to describe an inventory sensitivity case of the CA base case. The inventory sensitivity case implements a change in the activity contribution from the vadose zone in the A Trenches Area model (for tritium (H-3) and iodine-129 (I-129)), BC Cribs and Trenches model (for I-129 and technetium-99 (Tc-99)), and the PUREX Area model (for H-3 and I-129). All other simulated inventories are identical to the CA base case. The simulation of F&T of contaminants reported in this case will support dose predictions as part of the Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Recharge Sensitivity Case

The Plateau-to-River (P2R) model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company (CPCCo) at the Hanford Site in south-central Washington State. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation file (ECF) is to describe a recharge sensitivity case of the CA base case. The recharge sensitivity case implements a change in the activity contribution from the vadose zone in the A Trenches Area model (for tritium [H-3] and iodine-129 [I-129]), BC Cribs and Trenches model (for I-129 and technetium-99 [Tc-99]), or the Plutonium Uranium Extraction (PUREX) Area model (for H-3 and I-129). All other simulated inventories are identical to the CA base case. The simulation of fate and transport of contaminants reported in this case will support dose predictions as part of the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Null-Space Model Carlo Flow Model Set

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater pathway based on the null space Monte Carlo (NSMC) groundwater concentrations as a part an uncertainty analysis for the updated Hanford Site Composite Analysis (CA). The Plateau-to River (P2R) Groundwater Model (CP-57037, Model Package Report: Plateau to River Groundwater Model Version 8.3) is the CA base case that simulates the fate and transport of radiological contaminants within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. An NSMC analysis was performed to identify and quantify the potential uncertainties associated with the P2R Model. The result of the NSMC analysis is a set of flow and transport simulations that provide an estimated range of possible outcomes that are used to quantify the uncertainty associated with the simulated base case concentrations.

54 ENVIRONMENTAL SCIENCES↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Base Case

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater exposure pathway as a part of the updated Hanford Site Composite Analysis (CA). The purpose of these radiological dose assessments is to provide an estimate of the cumulative radiological impacts from all screened sources of ionizing radiation and exposure routes that could potentially contribute to the projected dose to a hypothetical member of the public from both existing or future disposal facilities and other sources including past-practice discharge sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

Updates to Composite Analysis Base Case and Null Space Monte Carlo Sensitivity Based on New Unit Dose Factors

This environmental calculation file (ECF) presents the results of the exposure route-specific and total radiological dose assessments for the groundwater exposure pathway as a part of the updated Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2022), based on revised unit dose factors (UDFs) published in CA Special Studies: Updates to the Groundwater Pathway Radiological Dose. The reason for these radiological dose assessments is to estimate the cumulative radiological impacts from all screened sources of ionizing radiation and exposure routes that could potentially contribute to the projected dose to a hypothetical member of the public. Sources of ionizing radiation can include existing or future disposal facilities and other sources including past-practice discharge sites. Additionally, the results of the exposure route-specific and total radiological dose assessments have been revised for the groundwater pathway based on the null space Monte Carlo (NSMC) groundwater concentrations and the most recent updates to the UDFs as a part an uncertainty analysis for the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyses of the Constant Rate Discharge Test for 299-W15-225 (2009) and Ringold Formation Unit A Well Development Tests for 699-43-67B (2012) and 699-45-67B (2013)

This Environmental Calculation File (ECF) documents analyses of hydraulic tests performed in the Ringold Formation member of Wooded Island unit A (Rwia) and Ringold Formation member of Wooded Island unit E (Rwie) in the 200 West Area. Two small-scale tests in the Rwia performed in 2012 and 2013 and one large-scale hydraulic test in the Rwie performed in 2009 were analyzed. Heterogeneity in the Rwie was also examined.

54 ENVIRONMENTAL SCIENCES↗

Method Development and Implementation for Characterizing Uncertainties in Tank Leak Volumes for Composite Analysis.

The purpose of this environmental calculation file (ECF) is to provide a summary of methodology, inputs, assumptions, and results of a Special Analysis (SA) titled “Method Development and Implementation for Characterizing Uncertainties in Tank Leak Volumes for the Updated Composite Analysis.” This SA is one of the three SAs conducted in Fiscal Year (FY) 2024 for the Composite Analysis (CA) for the Hanford Site (DOE/RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020)), and it is performed following the Unreviewed Composite Analysis Question Evaluation procedure, UCAQ-24-01-E (UCAQ-24-01-E, Rev. 0).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations for Updating Liquid Discharged Inventory and Transport Modeling Parameters for Cumulative Impacts Evaluation of Hexavalent Chromium in the 200 West Area

The purpose of this environmental calculation file (ECF) is to document information regarding hexavalent chromium (Cr(VI)) inventory discharged in 200 West Area at the Hanford Site and provide data to support predictive transport through the vadose zone and saturated zone for modeling efforts. This document provides a focused evaluation of historical waste stream data and studies to develop estimates of Cr(VI) inventory, discharge fractions, and transport parameters for the 200 West Area waste sites and tank farms during discharge events and for long-term contaminant releases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plateau to River Model Predictive Simulations for All Ensemble Realizations to Support Modeling Work in Fiscal Year 2025

The purpose of this environmental calculation file (ECF) is to document predictions of flow and hydraulic head on the Central Plateau of the Hanford Site using the Plateau-to-River (P2R) Model (CP-57037, Model Package Report for the Plateau-to-River Model: Version 9.1). This calculation documents the simulation of the groundwater for the parent model domain of the P2R Model as a basis for use in other applications of the P2R Model. This application is unique from the standpoint that it will simulate all ensemble member models of the P2R Model whereas other applications may only utilize specific ensemble members. These simulations provide results that can be used in the process of selecting an appropriate subset of ensemble members for other applications.

54 ENVIRONMENTAL SCIENCES↗

Hanford Composite Analysis Special Studies FY2025 - Groundwater Flow Simulation for use in a Comparison of Simulated Concentrations in the Saturated Zone Estimated by the Plateau-to-River Model Versions 8.3 and 9.1

In order to meet the requirements of U.S. Department of Energy (DOE) in DOE O 435.1, Radioactive Waste Management, a composite analysis (CA) must be completed for the Central Plateau at the Hanford Site. The CA requires estimates of fate and transport of radionuclides in the groundwater from multiple sources within the modeling domain. This Environmental Calculation File (ECF) details the application of the Plateau-to-River (P2R) Model (CP-57037, Rev. 3, Model Package Report for the P2R Model: Version 9.1) to predict the flow of groundwater on the Central Plateau for the 10,000-year simulation to support a special analysis associated with the Hanford Site CA. The simulated flow field will support the simulation of fate and transport of contaminants for comparison to the results obtained as part of the CA to evaluate impact of the updated version of the P2R Model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updates to the Hanford Soil Inventory Model (SIM Version 2) for FY 2025

Update SIM to newest version (SIMv2.3). SIM is being updated to reflect the updates to the tank leak inventories performed in ECF-HANFORD-24-0061. This update is also being done to publish the site inventories in both 2001 decayed and back-decayed formats. This is particularly needed for modeling that requires inventory data from before 2001 that includes decay information for radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗