Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ECC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Importance of eccentric actions in performance adaptations to resistance training

The importance of eccentric (ecc) muscle actions in resistance training for the maintenance of muscle strength and mass in hypogravity was investigated in experiments in which human subjects, divided into three groups, were asked to perform four-five sets of 6 to 12 repetitions (rep) per set of three leg press and leg extension exercises, 2 days each weeks for 19 weeks. One group, labeled 'con', performed each rep with only concentric (con) actions, while group con/ecc with performed each rep with only ecc actions; the third group, con/con, performed twice as many sets with only con actions. Control subjects did not train. It was found that resistance training wih both con and ecc actions induced greater increases in muscle strength than did training with only con actions.

Dudley, Gary A.↗

Influence of eccentric actions on the metabolic cost of resistance exercise

The contributions of concentric (con) and eccentric (ecc) muscle actions are evaluated with respect to increasing the metabolic cost of resistance exercise. Male subjects perform leg exercise with either con and ecc actions or only con actions while the net energy cost of the exercise is measured by oxygen consumption data. In both groups, the con actions require 290 J/kg body weight of total work, with an energy cost of 0.003 cal/J. The energy costs for the con/ecc actions of the second group is increased by 14 percent. The metabolic cost of leg exercise is concluded to be primarily generated by the con leg actions, and ecc leg actions increase the resistance with only a slight increase in required energy. The findings are significant for practical applications that emphasize the conservation of energy expenditure during exercise in spacecraft environments.

Dudley, Gary A.↗

Magnetic resonance imaging and electromyography as indexes of muscle function

A hypothesis is tested that exercise-induced magnetic resonance (MR) contrast shifts would relate to electromyography (EMG) amplitude if both measures reflect muscle use during exercise. Both magnetic resonance images (MRI) and EMG data were obtained for separate eccentric (ECC) and cocentric (CON) exercise of increasing intensity for seven subjects 30-32 yr old. CON and ECC actions caused increased integrated EMG (IEMG) and T2 values which were strongly related with relative resistance. The rate of increase and absolute value of both T2 and IEMG were found to be greater for CON than for ECC actions. For both actions IEMG and T2 were correlated. Data obtained suggest that surface IEMG accurately reflects the contractile behavior of muscle and exercise-induced increases in MRI T2 values reflect certain processes that scale with muscle use.

Adams, Gregory R.↗

Links between N-modular redundancy and the theory of error-correcting codes

N-Modular Redundancy (NMR) is one of the best known fault tolerance techniques. Replication of a module to achieve fault tolerance is in some ways analogous to the use of a repetition code where an information symbol is replicated as parity symbols in a codeword. Linear Error-Correcting Codes (ECC) use linear combinations of information symbols as parity symbols which are used to generate syndromes for error patterns. These observations indicate links between the theory of ECC and the use of hardware redundancy for fault tolerance. In this paper, we explore some of these links and show examples of NMR systems where identification of good and failed elements is accomplished in a manner similar to error correction using linear ECC's.

Bobin, V.↗

Extended cooperative control synthesis

This paper reports on research for extending the Cooperative Control Synthesis methodology to include a more accurate modeling of the pilot's controller dynamics. Cooperative Control Synthesis (CCS) is a methodology that addresses the problem of how to design control laws for piloted, high-order, multivariate systems and/or non-conventional dynamic configurations in the absence of flying qualities specifications. This is accomplished by emphasizing the parallel structure inherent in any pilot-controlled, augmented vehicle. The original CCS methodology is extended to include the Modified Optimal Control Model (MOCM), which is based upon the optimal control model of the human operator developed by Kleinman, Baron, and Levison in 1970. This model provides a modeling of the pilot's compensation dynamics that is more accurate than the simplified pilot dynamic representation currently in the CCS methodology. Inclusion of the MOCM into the CCS also enables the modeling of pilot-observation perception thresholds and pilot-observation attention allocation affects. This Extended Cooperative Control Synthesis (ECCS) allows for the direct calculation of pilot and system open- and closed-loop transfer functions in pole/zero form and is readily implemented in current software capable of analysis and design for dynamic systems. Example results based upon synthesizing an augmentation control law for an acceleration command system in a compensatory tracking task using the ECCS are compared with a similar synthesis performed by using the original CCS methodology. The ECCS is shown to provide augmentation control laws that yield more favorable, predicted closed-loop flying qualities and tracking performance than those synthesized using the original CCS methodology.

Davidson, John B.↗

Results of the NY-Alesund ozone measurements intercomparison NAOMI

Worldwide, about ten Differential Absorption Lidars are used for long-term monitoring of stratospheric ozone. These systems are an important component of the Network for the Detection of Stratospheric Change. Although DIALs are self-calibrating in principle, regular intercomparisons with other ozone-lidars, microwave radiometers or ozone-sondes are highly desirable to ensure high data quality at a well known level. The Network for the Detection of Stratospheric Change (NDSC) validation policy suggests that such intercomparisons be "blind", meaning all participants submit their data to an impartial referee, without seeing results from the other participants. Here we report on the "blind" intercomparison taking place from January 20th to February 10th 1998 at Ny-Alesund, Spitsbergen (78.92 deg N, 11.95 deg E). Participating groups were from the Alfred Wegener Institute, Potsdam, operating the NDSC DIAL system at Ny-Alesund, from the University of Bremen operating the NDSC microwave radiometer for ozone profiling at Ny-Alesund, and the NASA Goddard Space Flight Center group with the "NDSC travelling standard" STROZ-LITE. The first author acted as the impartial referee. Also used for the intercomparison were data from ECC-6A/Vaisala RS80 ozone sondes routinely launched at Ny-Alesund by the AWI group. A 1% KI solution (3 ml) and the 1986 ECC pump correction (1.092 at 5 hPa) are used. The ECC-data were available to all participants during the campaign and thus were not "blind". Table 1 summarizes the expected performance of the instruments participating in the ozone intercomparison reported in this paper.

Steinbrecht, W.↗

An Interoperability Consideration in Selecting Domain Parameters for Elliptic Curve Cryptography

Elliptic curve cryptography (ECC) will be an important technology for electronic privacy and authentication in the near future. There are many published specifications for elliptic curve cryptosystems, most of which contain detailed descriptions of the process for the selection of domain parameters. Selecting strong domain parameters ensures that the cryptosystem is robust to attacks. Due to a limitation in several published algorithms for doubling points on elliptic curves, some ECC implementations may produce incorrect, inconsistent, and incompatible results if domain parameters are not carefully chosen under a criterion that we describe. Few documents specify the addition or doubling of points in such a manner as to avoid this problematic situation. The safety criterion we present is not listed in any ECC specification we are aware of, although several other guidelines for domain selection are discussed in the literature. We provide a simple example of how a set of domain parameters not meeting this criterion can produce catastrophic results, and outline a simple means of testing curve parameters for interoperable safety over doubling.

Ivancic, Will↗

Profiling the SO2 Plume from Volcan Turrialba: Ticosonde Balloon Measurements Compared with OMI and OMPS Retrievals

The summit of Volcan Turrialba (elev. 3340 m) lies less than 50 km upstream in the prevailing easterlies from the Ticosonde balloon launch site at San Jose, Costa Rica, where ECC ozone sondes have been launched regularly since 2005. In 2006 we began to see telltale notches in the ozone profiles in the altitude range between 2 and 6 km. Given the proximity of Turrialba, it seemed likely that SO2 in the volcano's plume was interfering in the chemical reaction in the ECC ozone sonde used to detect ozone. In early 2010, fumarolic activity in the Turrialba crater increased strongly, and the profile notches in our soundings increased in frequency as well, consistent with this hypothesis. In February 2012 we tested a dual ECC sonde system, where an additional sonde is flown on the same payload using a selective SO2 filter. The difference of the measurements in the dual sonde is a direct measure of the amount of SO2 encountered. This first dual sonde passed through the plume, and the data indicated a tropospheric SO2 column of 1.4 DU, comparing favorably with a total column of 1.7 DU in the OMI 3-km linear fit (LF) product at the sonde profile location and at nearly the same time. We are now launching dual sondes on a regular basis with 18 launches in the first 12 months through July 2014; 11 of these have detectable SO2 signals. These soundings have great potential for validation of the Aura OMI and the Suomi-NPP OMPS retrievals of SO2. Here we present the sonde measurements and compare them with two satellite datasets: the Aura OMI Linear Fit (LF) product and the Suomi-NPP OMPS Principal Components Analysis (PCA) boundary layer product. The PCA algorithm reduces retrieval noise and artifacts by more accurately accounting for various interferences in SO2 retrievals such as O3 absorption and rotational Raman scattering. The comparisons with the in situ observations indicate a significant improvement of the PCA algorithm in capturing relatively weak volcanic SO2 signals.

sondes↗

Tropospheric Ozone Assessment Report: Tropospheric Ozone From 1877 to 2016, Observed Levels, Trends and Uncertainties

From the earliest observations of ozone in the lower atmosphere in the 19th century, both measurement methods and the portion of the globe observed have evolved and changed. These methods have different uncertainties and biases, and the data records differ with respect to coverage (space and time), information content, and representativeness. In this study, various ozone measurement methods and ozone datasets are reviewed and selected for inclusion in the historical record of background ozone levels, based on relationship of the measurement technique to the modern UV absorption standard, absence of interfering pollutants, representativeness of the well-mixed boundary layer and expert judgement of their credibility. There are significant uncertainties with the 19th and early 20th-century measurements related to interference of other gases. Spectroscopic methods applied before 1960 have likely underestimated ozone by as much as 11% at the surface and by about 24% in the free troposphere, due to the use of differing ozone absorption coefficients. There is no unambiguous evidence in the measurement record back to 1896 that typical mid-latitude background surface ozone values were below about 20 nmol mol–1, but there is robust evidence for increases in the temperate and polar regions of the northern hemisphere of 30–70%, with large uncertainty, between the period of historic observations, 1896–1975, and the modern period (1990–2014). Independent historical observations from balloons and aircraft indicate similar changes in the free troposphere. Changes in the southern hemisphere are much less. Regional representativeness of the available observations remains a potential source of large errors, which are difficult to quantify. The great majority of validation and intercomparison studies of free tropospheric ozone measurement methods use ECC ozonesondes as reference. Compared to UV-absorption measurements they show a modest (~1–5% ±5%) high bias in the troposphere, but no evidence of a change with time. Umkehr, lidar, and FTIR methods all show modest low biases relative to ECCs, and so, using ECC sondes as a transfer standard, all appear to agree to within one standard deviation with the modern UV-absorption standard. Other sonde types show an increase of 5–20% in sensitivity to tropospheric ozone from 1970–1995. Biases and standard deviations of satellite retrieval comparisons are often 2–3 times larger than those of other free tropospheric measurements. The lack of information on temporal changes of bias for satellite measurements of tropospheric ozone is an area of concern for long-term trend studies.

UV absorption standard↗

An Examination of the Recent Stability of Ozonesonde Global Network Data

The recent Assessment of Standard Operating Procedures for OzoneSondes (ASOPOS 2.0; WMO/GAW Report #268) addressed questions of homogeneity and long-term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura’s Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura’s Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004 in light of the sudden post-2013 TCO “dropoff” of ~3-4% that was reported previously at select stations (Stauffer et al., 2020). Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about ±2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within ±5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of dropoff stations in the tropics and subtropics. The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.

Ryan M. Stauffer↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Analysis of iron-chromium-aluminum samples exposed to accident conditions followed by quench in the QUENCH-19 experiment

The QUENCH-19 experiment was a first-of-its-kind full-bundle test simulating accident conditions followed by water quench on accident-tolerant fuel (ATF) cladding. Here, a type of FeCrAl(Y) alloy, B136Y3, was developed at Oak Ridge National Laboratory and tested at the Karlsruhe Institute of Technology using Kanthal APM corner rods, a shroud, and Kanthal AF spacer grids. Testing conditions were similar to those in QUENCH-15—which tested ZIRLO cladding behavior—so that B136Y3 and ZIRLO cladding could be compared. QUENCH-19 consisted of an initial pre-oxidation heating followed by a transient. Then, a maximum power hold, which was not present in QUENCH-15, was executed to extend the heating period for the FeCrAl(Y) rods. Finally, a rapid water quench was executed that was similar to emergency core coolant system (ECCS) actuation. Compared with the ZIRLO rods in QUENCH-15, the bundle in QUENCH-19 released significantly less H 2 (9.2 g vs. 47.6 g) and achieved a much lower maximum temperature (1455°C vs. 1880°C). Furthermore, no breakaway oxidation was observed in QUENCH-19. Metallographic mounts revealed that despite the symmetry of the setup, at elevations near the maximum temperature, cladding and thermocouples were heavily damaged, substantial melting and oxidation occurred, and the cladding underwent chemical interaction with the thermocouple sheaths. Additionally, the ZrO 2 spacers detrimentally interacted with the cladding, leading to mixed oxide debris and the full destruction of some rods. Additional failure was found in certain cooler rods that may have risen due to the high thermal expansion coefficient of FeCrAl alloys. This paper presents an analysis of this work, which suggests that FeCrAl cladding can chemically survive anticipated loss-of-coolant accident events followed by rapid ECCS quench if the correct geometry and core design are present.

36 MATERIALS SCIENCE↗

Simulation and Analysis on Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS) under SBLOCA scenario by using Cardinal to support the fracture mechanics analyses

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended durations or under accident condition. As one of the most significant components of a Reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Ageing degradation mechanisms (e.g. thermos-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary. The multi-physics simulations are performed using Cardinal, a wrapping of the GPU-oriented spectral element Computational Fluid Dynamics (CFD) code NekRS and other multi-physics sub-modules within the MOOSE framework. Cardinal now fully supports MOOSE stochastic perturbations of NekRS models with varying boundary conditions, initial conditions, material properties, and any other quantity which is defined by a kernel (such as coefficients in a momentum source model). The implementation is designed in a flexible manner so that scalar values are sent from MOOSE into a user scratch space in NekRS, which can then be applied for any purpose within the NekRS case files (both on the host and device). When modeling PTS, several factors can impact the results significantly. In this report, the impacts of the geometry of the model, Reynolds number and buoyancy effect are investigated. Two geometry, i.e., a simplified model and a realistic RPV model, with both laminar and turbulent flow condition are adopted for the PTS simulation with and without buoyancy effect. The purpose of the investigation is to understand the impact of these factors on the prediction of temperature history of RPV. The accurate prediction on the temperature evolution, which will be exported to Grizzly code for further analyses on the progression of aging mechanisms and their effects on the integrity of RPV structures, is very crucial. Based on the understanding of these factors, a more sophisticated model is built to analysis the PTS under SBLOCA scenario. A literature survey is conducted to pick the SBLOCA scenario for the multi-physics simulation. The analysis helps to explain the form and the transformation of the cold plum when the ECC is activated under SBLOCA. This model can be can be applied to study the PTS effect for different RPV configurations. The results can help to assess structural component degradation for advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emerald Connections Weatherization Plus Health Pilot Program

The Emerald Connections Weatherization Plus Health Pilot Program (Healthy Homes Pilot or the pilot), delivered 97 comprehensive energy retrofits to low-income households in two underserved communities: Lynn, Massachusetts (57) and the Beacon Hill neighborhood in Seattle, Washington (40). Designed by Emerald Cities Collaborative (ECC) and funded via a U.S. Department of Energy (DOE) Weatherization Assistance Program (WAP) Enhancement and Innovation (E&I) grant, ECC created the pilot to expand the reach and range of services typically available to participating WAP households.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrochemical concentration cell ozonesonde performance evaluation

A large number of electrochemical concentration cell (EDD) ozonesondes were calibrated relative to ultraviolet photometric absorption (254 nm) to determine their precision and accuracy. The average agreement with UV photometry was found to be good, but with considerable variation from one ECC ozonesonde to another. Applying individual calibrations to vertical ozone profiles reduced the systematic differences between ECC ozonesonde total ozone values and Dobson spectrophotometric determinations of the same quantity, but did not improve random differences.

Torres, A. L.↗

Performance characteristics of the electrochemical concentration cell ozonesonde

A large number of electrochemical concentration cell (ECC) ozonesondes were calibrated in relation to a UV photometric absorption ozone instrument prior to using the ozonesondes in atmospheric soundings. The two methods of measuring ozone were in reasonable agreement on the average, but there was considerable variation from one ozonesonde to another. Averaging the individual linear regressions gives an ECC ozone concentration equal to 0 + or - 8 nbar plus (0.96 + or - 0.10) times the concentration determined with the UV instrument, where uncertainties represent 90% confidence limits. Applying individual calibration corrections to atmospheric sounding data reduced the mean difference between Dobson spectrophotometric measurements of total ozone overburdens and corresponding values obtained from ozonesonde data from -8.5 + or - 8.2 to -1.4 + or - 7.3% for a series of measurements carried out in 1977. Corresponding uncorrected and corrected differences averaged 3.2 + or - 9.7 and 1.9 + or - 10.6%, respectively, for soundings carried out in 1976.

Torres, A. L.↗

An evaluation of electrochemical concentration cell sonde measurements of atmospheric ozone

Using Dobson spectrophotometer measurements of total ozone as a comparison, an analysis of the Electrochemical Concentration Cell (ECC) ozonesonde's measurement accuracy is presented. Days of conjunctive ECC-Dobson observations (from 1970 to 1976 at Wallops Flight Center) provide a set of 123 pairs of total ozone values. Sample set statistics are generated with means and standard deviations of total ozone values and differences being noted. An in-depth study of factors such as time differences between associated observations, integration techniques used, assumptions used in calculating residual ozone and other possible sources of errors are examined. Short-period changes in total ozone using Dobson data during the observational period are also described.

Geraci, M. J.↗

Correlative Measurements Program

The GSFC Correlative Measurements Program at the Wallops Flight Facility was represented on the Satellite/Satellite Intercomparisons Working Group. The Correlative Measurements Program uses the Rocket Ozonesonde (ROCOZ-A) and the Electrochemical Concentration Cell (ECC) balloon borne ozonesonde to measure the vertical profile of ozone amount in the atmosphere. The balloon work is described in a separate report. The ROCOZ-A instrument was used for many years to provide in situ truth data for various satellite ozone measuring systems, such as SBUV on Nimbus-7, SAGE-II, SBUV-II on the NOAA series of polar orbiting satellites, SME, LIMS, etc. The particular data sets of interest to the Ozone Trends Panel Working Group were collected at Natal, Brazil. The major results produced for and used by the Ozone Trends Panel are shown. The ROCOZ-A average ozone density profile is plotted versus altitude on the left. ECC ozonesondes were used for the portion of the profile below 20 km, the lower limit for ROCOZ-A. The difference between SAGE-II and ROCOZ-A average density profiles is shown.

Parsons, C. L.↗