Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dynamic range considerations for EUV MAMA detectors

The multianode microchannel array (MAMA) has been chosen as the detector for two instruments on the ESA/NASA Solar Heliospheric Observatory. The response of the MAMA to the two extreme types of solar spectra, disk and corona, have been modeled with a view toward evaluating dynamic range effects present. The method of MAMA operation is discussed, with emphasis given to modeling the effect of electron cloud charge spreading to several detector anodes and amplifiers (n-fold events). Representative synthetic EUV spectra have been created. The detector response to these spectra is modeled by dissecting the input photon radiation field across the detector array into contributions to the various amplifier channels. The results of this dissection are shown for spectral regions across the entire wavelength region of interest. These results are used to identify regions in which total array photon counting rate or individual amplifier rate may exceed the design limits. This allows the design or operational modes to be tailored to eliminate the problem areas.

Illing, Rainer M. E.↗

Signal phase switches offer greater dynamic range

Circuit, placed in the signal path of a closed-loop receiver to modulate telemetered data in the 10-MHz spectrum, improves signal-to-noise ratio by 3 db in a communication receiver. The switch enables bandwidth reduction which reduces noise overload on the following stages, giving the system greater dynamic range.

Crow, R. B.↗

NucD-25 Nuclear Diagnostics Development: NIS capability, Maximizing gamma ray dynamic range, (n,γ) measurements for carbon ρR [Slides]

The LANL Neutron Imaging team is preparing for NIS upgrades and novel capabilities with the advent of consistently higher yields at NIF. Novel scintillators, solid-state detectors, multiplexed imaging detectors, upgraded data acquisition systems, and camera testing are all areas in need of experimental study to further develop imaging capabilities and dynamic range at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing the linearity of response of gated photomultipliers in wide dynamic range laser radar systems

Laser radar data acquisition systems have been utilized in conjunction with a light emitting diode to evaluate photomultipliers for laser radar use. Light pulses with an exponential decay rate of approximately one decade per sixty microseconds, as well as other pulse shapes, were used to drive the tubes. Properties studied in the analog mode include nonlinearity at high output currents, transient behavior upon gating, gate holdoff, dynamic range limitations because of light-induced noise, and the effect of dynode gating on tubes without a focus grid. Some of these properties were also studied in the photon counting mode, along with single photoelectron pulse shape and afterpulsing. A brief description of the laser radar technique of atmospheric measurements is included.

Hunt, W. H.↗

System and method for high dynamic range waveform digitization

Diverse applications from particle physics experiments to lidar are driving cost and current reduction in giga-hertz sampling rate high-resolution data conversion. Multiple imagers captures a single pixel of data and require processing at very high speed. High-bandwidth high-rate signal sampling, analog-to-digital conversion, and transfer of large amounts of data to a digital data acquisition block are required in such systems. Dynamic range, power consumption, and transfer of high-speed, high-bit width data are key implementation challenges. Data acquisition architectures optimized for specific requirements of such systems may facilitate system implementation and reduce overall system cost.

Mostafanezhad, Isar↗

An evaluation of an ICCD imager of dynamic range expansion technique and application of insitu procedures for life-time extension

Research toward practical implementation of the Intensified Charge Coupled Device (ICCD) as a photon-counting array detector for astronomy is reported. The first area of concentration was to determine the rate and extent of the lifetime limiting damage to the CCD caused by the impact of high energy electrons, and to find whether various methods of annealing the damage were productive. The second effort was to determine the performance of the ICCD in a photon-counting mode to produce extended dynamic range measurements. There are two main effects that appear as the practical results of the electron damage to the CCD. One is an increase in the leakage current, i.e., the normal thermal generation of charge carriers in the silicon that provides a background dark signal that adds to the light produced image. In an undamaged CCD, the leakage current is usually fairly uniform across the photosensitive area of the silicon chip, with the exception of various bright pixels which have an anomalous leakage current well above the overall level.

Currie, D. G.↗

Maximizing dynamic range and performance of anatase TiO 2 ECRAM through structure and programming

Here, in this study, we investigate the structure-dependent modulation characteristics of all-solid-state three-terminal electrochemical random-access memory (ECRAM) based on an anatase Li x TiO 2 channel. By directly comparing “asymmetric” and “symmetric” ECRAM device architectures, we reveal significant insight into the impact of a non-zero gate-drain open-circuit voltage and its influence on voltage vs. current-controlled gating. We also explore the impact of potentiation/depression write parameters on the symmetry, linearity, and dynamic range of the device response. Together, initial results from optimizing structure and programming approaches yielded unprecedented G max /G min ratios of >1,000 for ECRAM and hundreds of tunable memory states with excellent linearity and symmetry. Simulations based on these ECRAM devices further illustrate the promise of this analog memory technology, achieving near 2% classification error in the MNIST digit recognition benchmark for a range of training parameters compared to a theoretical best of 1.66% and outperforming other device models extracted from the literature.

AIHWKit↗

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending the Dynamic Range of Galaxy Outflow Scaling Relations: Massive Compact Galaxies with Extreme Outflows

We investigate galactic winds in the HizEA galaxies, a collection of 46 late-stage galaxy mergers at z = 0.4–0.8, with stellar masses of $\mathrm{log}({M}_{* }/{M}_{\odot })=10.4\mbox{--}11.5$ , star formation rates (SFRs) of 20–500 M ⊙ yr -1 , and ultra-compact (a few 100 pc) central star-forming regions. We measure their gas kinematics using the Mg II λλ 2796,2803 absorption lines in optical spectra from MMT, Magellan, and Keck. We find evidence of outflows in 90% of targets, with maximum outflow velocities of 550–3200 km s -1 . We combine these data with ten samples from the literature to construct scaling relations for outflow velocity versus SFR, star formation surface density (Σ SFR ), M * , and SFR/M * . The HizEA galaxies extend the dynamic range of the scaling relations by a factor of ~2–4 in outflow velocity and an order of magnitude in SFR and Σ SFR . The ensemble scaling relations exhibit strong correlations between outflow velocity, SFR, SFR/R, and Σ SFR , and weaker correlations with M * and SFR/M * . The HizEA galaxies are mild outliers on the SFR and M* scaling relations, but they connect smoothly with more typical star-forming galaxies on plots of outflow velocity versus SFR/R and Σ SFR . These results provide further evidence that the HizEA galaxies' exceptional outflow velocities are a consequence of their extreme star formation conditions rather than hidden black hole activity, and they strengthen previous claims that Σ SFR is one of the most important properties governing the velocities of galactic winds.

79 ASTRONOMY AND ASTROPHYSICS↗

Silica Aerogels Doped with Ru(II) Tris 1,l0-Phenanthro1ine)-Electron Acceptor Dyads: Improving the Dynamic Range, Sensitivity and Response Time of Sol-Gel Based Oxygen Sensors

Complexes 1 and 2 were characterized in fluid and frozen solution and as dopants of silica aerogels. The intramolecular quenching efficiency of pendant 4-benzoyl-N-methylpyridinium group (4BzPy) is solvent dependent: emission is quenched completely in acetonitrile but not in alcohols. On the other hand, N-benzyl-N'-methylviologen (BzMeV) quenches the emission in all solvents completely. The differences are traced electrochemically to a stronger solvation effect by the alcohol in the case of 1. In fiozen matrices or absorbed on the surfaces of silica aerogel, both 1 and 2 are photoluminescent. The lack of quenching has been traced to the environmental rigidity. When doped aerogels are cooled to 77K, the emission shifts to the blue and its intensity increases in analogy to what is observed with Ru(II) complexes in media undergoing fluid-to-rigid transition. The photoluminescence of 1 and 2 from the aerogel is quenched by oxygen diffusing through the pores. In the presence of oxygen, aerogels doped with 1 can modulate their emission over a wider dynamic range than aerogels doped with 2, and both are more sensitive than aerogels doped with Ru(II) tris(1,l0- phenanthroline). In contrast to frozen solutions, the luminescent moieties in the bulk of aerogels kept at 77K are still accessible, leading to more sensitive platforms for oxygen sensors than other ambient temperature configurations.

Kevebtusm Bucgikas↗

Orthostatic stress is necessary to maintain the dynamic range of cardiovascular control in space

In the upright position, gravity fills the low-pressure systems of human circulation with blood and interstitial fluid in the sections below the diaphragm. Without gravity one pressure component in the vessels disappears and the relationship between hydrostatic pressure and oncotic pressure, which regulates fluid passage across the capillary endothelium in the terminal vascular bed, shifts constantly. The visible consequences of this are a puffy face and "bird" legs. The plasma volume shrinks in space and the range of cardiovascular control is reduced. When they stand up for the first time after landing, 30-50% of astronauts suffer from orthostatic intolerance. It remains unclear whether microgravity impairs cardiovascular reflexes, or whether it is the altered volume status that causes the cardiovascular instability following space flight. Lower body negative pressure was used in several space missions to stimulate the cardiovascular reflexes before, during and after a space flight. The results show that cardiovascular reflexes are maintained in microgravity. However, the astronauts' volume status changed in space, towards a volume-retracted state, as measurements of fluid-regulating hormones have shown. It can be hypothesized that the control of circulation and body fluid homeostasis in humans is adapted to their upright posture in the Earth's gravitational field. Autonomic control regulates fluid distribution to maintain the blood pressure in that posture, which most of us have to cope with for two-thirds of the day. A determined amount of interstitial volume is necessary to maintain the dynamic range of cardiovascular control in the upright posture; otherwise orthostatic intolerance may occur more often.

manned↗

Synthesis and Characterization of Ru(II) Tris(1,1O-phenanthroline)-Electron Acceptor Dyads Incorporating the 4-benzoyl-N-methylpyridinium Cation or N-Benzyl-N'-methyl-viologen. Improving the Dynamic Range, Sensitivity and Response Time of Sol-Gel Based Optical Oxygen Sensors

The title compounds (1 and 2, above) were synthesized by Sonogashira coupling reactions of appropriate Ru(1I) complexes with the electron a cceptors. Characterization was conducted in solution and in frozen ma trices. Finally, the title compounds were evaluated as dopants of sol-gel materials. It was found that the intramolecular quenching efficie ncy of 4-benzoyl-Nmethylpyridinium cation in solution depends on the solvent: photoluminescence is quenched completely in CH,CN, but not i n methanol or ethanol. On the other hand, intramolecular emission que nching by 4-benzyl-N-methyl viologen is complete in all solvents. The difference between the two quenchers is traced electrochemically to t he solvation of the 4-benzoyl-Nmethylpyridiniums by alcohol. In froze n matrices or adsorbed on the surfaces of silica aerogel, both Ru(I1) complex/electron acceptor dyads of this study are photoluminescent, and the absence of quenching has been traced to the environmental rigi dity. When doped aerogels are cooled at 77 K, the emission intensity increases by approximately 4x, and the spectra shift to the blue, analogous to what is observed with Ru(I1) complexes in solutions undergoi ng fluid-to-rigid transition. However, in contrast to frozen solution s, the luminescent moieties in the bulk of aerogels kept at low tempe ratures are still accessible to gas-phase quenchers diffusing through the mesopores, leading to more sensitive platforms for sensors than o ther room-temperature configurations. Thus the photoluminescence of o ur Ru(I1) complex dyads adsorbed on aerogel is quenchable by O2 both at room temperature and at 77 K. Furthermore, it was also found that O 2 modulates the photoluminescence of aerogels doped with 4-benzoyl -N -methylpyridinium-based dyads over a wider dynamic range compared wi th aerogels doped with either our vislogen-based dyads or with Ru(I1) tris(1,lO-phenanthroline) itself.

Leventis, Nicholas↗

He II Liquid/Vapor Phase Separator for Large Dynamic Range Operation

A phase separator, which separates helium vapor from liquid superfluid helium (He II), is an indispensable device for space cryogenics. The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which only the detector package is cold at launch, the remainder of the telescope being subsequently cooled to operating temperature on orbit. Therefore, a large dynamic operational range is required of the cryogen system. This is a report of initial laboratory test results with candidate porous plugs as phase separators. Mass flow rates and pressure and temperature differences across a porous plug were measured in this experiment. Relatively large mass flow rates were observed even at small pressure differences. In the high mass flow rate region, a hysteresis was observed with increases and decreases of the pressure difference. A linear theory is proposed and compared with experimental data to explain several phenomena observed in this system.

Phase Separator, Space Cryogenics↗