Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Double Beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Spallation Neutron Source Normal Conducting Linac RF System Design for the Proton Power Upgrade Project

The Proton Power Upgrade (PPU) project at the Spallation Neutron Source will double the available proton beam power from 1.4 to 2.8 MW by increasing the beam energy from 1.0 to 1.3 GeV and the beam current from 26 to 38 mA. The increase in beam current resulted in the need to redesign the existing normal conducting linac (NCL) RF Systems. High-power testing of the existing NCL RF Systems configured to accelerate PPU-level beam provided the data used to make the final design decisions. This paper describes the development and execution of those in-situ tests and the subsequent results.

Moss, John↗

Shielding Analyses for SNS Accelerator Power Upgrade

The Proton Power Upgrade (PPU) project [1] at Spallation Neutron Source (SNS) is aiming at increasing the neutron beam intensities at the First Target Station (FTS) and advancing accelerator capability to additionally power a future Second Target Station (STS) [2]. PPU will involve upgrading the SNS accelerator complex to double the currently available proton beam power from 1.4 to 2.8 MW, by increasing the proton beam energy from 1 GeV to 1.3 GeV and by increasing the proton beam current.PPU will enable new science capabilities enhancing the experiment throughput of the 19 existing FTS instruments, which are heavily oversubscribed. STS will include 22 additional neutron scattering instruments. Numerous neutronics analyses are performed to support PPU evaluating the FTS systems for higher beam power and for system upgrades. Part of the PPU scope is an extension of the Ring to Target Beam Transport (RTBT) line, a stub out of the accelerator tunnel for the future Ring to STS Transport (RTST) line[3]. As the RTST tunnel will not be built within the PPU project, the stub will be shielded by a plug, which is planned to be made from regular concrete.In order to provide radiation protection safety, analyses are required to design adequate plug thickness for the stub. The thickness of the stub is driven by the criterion that the area downstream of the plug is “unrestricted access area”, demanding the dose rate downstream the stub be below 0.25 mrem/h at 30 cm from the surface at normal operation and below 20 Rem/hr for accident cases. Additionally, analyses verifying the amount of soil for shielding the accelerator tunnel to the above stated requirements are performed.

Popova, Irina I.↗

Neutrino masses from low scale partial compositeness

We consider a class of models in which the neutrinos acquire Majorana masses through mixing with singlet neutrinos that emerge as composite states of a strongly coupled hidden sector. In this framework, the light neutrinos are partially composite particles that obtain their masses through the inverse seesaw mechanism. We focus on the scenario in which the strong dynamics is approximately conformal in the ultraviolet, and the compositeness scale lies at or below the weak scale. The small parameters in the Lagrangian necessary to realize the observed neutrino masses can naturally arise as a consequence of the scaling dimensions of operators in the conformal field theory. We show that this class of models has interesting implications for a wide variety of experiments, including colliders and beam dumps, searches for lepton flavor violation and neutrinoless double beta decay, and cosmological observations. At colliders and beam dumps, this scenario can give rise to striking signals involving multiple displaced vertices. The exchange of hidden sector states can lead to observable rates for flavor violating processes such as μ → eγ and μ → e conversion. If the compositeness scale lies at or below a hundred MeV, the rate for neutrinoless double beta decay is suppressed by form factors and may be reduced by an order of magnitude or more. The late decays of relic singlet neutrinos can give rise to spectral distortions in the cosmic microwave background that are large enough to be observed in future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heavy neutrino searches through double-bang events at Super-Kamiokande, DUNE, and Hyper-Kamiokande

A variety of new physics scenarios allows for neutrinos to up-scatter into a heavy neutral lepton state. For a range of couplings and neutrino energies, the heavy neutrino may travel some distance before decaying to visible final states. When both the up-scattering and decay occur within the detector volume, these “double bang” events produce distinctive phenomenology with very low background. In this work, we first consider the current sensitivity at Super-Kamiokande via the atmospheric neutrino flux, and find current data may already provide new constraints. We then examine projected future sensitivity at DUNE and Hyper-Kamiokande, including both atmospheric and beam flux contributions to double-bang signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Probe Campaign FY24 Omega EP Shot Request [Slides]

The ultimate goal of the Multi-Probe experimental campaign is to assess the feasibility of using multiple probe species (x-ray, proton, neutron, and electron) in future LANL radiographic facilities. To use Omega EP most efficiently, two different experiments are proposed for each of the two requested days in FY24. In this way, shots may be interleaved on the two short pulse beams and the shot rate doubled. In FY24, we propose to continue to develop the neutron source by first optimizing the “pitcher” source of deuterons/protons and then adding the “catcher” neutron converter on day 2. The second series of experiments continues examining the origin and nature of the x-ray background found in our last two experiments. This background is not well understood or characterized by the community. The first day will measure the electrons emanating from the proton and x-ray targets while also optimizing the background shielding first used in FY23. The second day will test a geometry that enables simultaneous radiographs using both short-pulse beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double grating shearing interferometry for X-ray free-electron laser beams

The advancements in bright and coherent X-ray free-electron lasers (XFEL) have in the last decade revolutionized diverse fields of study, leading to an ever-increasing demand in more intense X-ray pulses. The accurate knowledge of the wavefront and the focal profile of such pulses ultimately dictates much of the experimental outcome.Herewe present a singleshot shearing interferometry method to measure the wavefront of a focused hardXFELpulse.Twoidentical transmission gratings are placed near the focus, and the interference pattern of overlapping diffraction orders is analyzed, resulting in a two-dimensional reconstruction of the X-ray wavefront. The spatial resolution and wavefront sensitivity can be tuned insitu during the measurement. The method is non-invasive (i.e., the zeroth order or transmitted pulse is not modified in intensity or profile), allowing for either a simultaneous intensity measurement at high resolution or a fully characterized transmitted pulse for general experimental use.

47 OTHER INSTRUMENTATION↗

Second harmonic Bessel-Gauss beam shaping with elliptic axicon aberrations

The second harmonic (SH) of an axicon generated Bessel-Gauss beam is created through the nonlinear interaction of photons with a crystal, resulting in the energy doubling of the output photons. In this work, we show experimentally that in addition to frequency doubling, the SH of Bessel-Gauss beams under asymmetric aberrations from an elliptic axicon exhibit intriguing beam formation. Particularly, the central region of the SH beam profile is composed of two central spots of various geometries surrounded by nested ellipses; one of which is the configuration of two central gamma dots with similar radius knotted by nested ellipses for a zeroth-order Bessel-Gauss pump. These SH beams consistently maintain their spatial profile throughout propagation, reminiscing the behavior of screw dislocations in wave patterns. Our numerical simulations produce beam dynamics consistent with that of experiments and further implicate the remarkable interweaving of bright spots with dark vortices. This is especially noticeable when the beams dynamically oscillate along the optical axis, resulting in the genesis of spatially polarized beams with a knotted framework. The insights gained from our study establish a novel paradigm for exploring interactions of Bessel-like beams with vortex dynamics. This, in turn, has the potential to spark innovations in optical applications, fostering new methodologies to harness and manipulate complex light structures. Our experimental findings could spur new methods of generating logical states of light and new opportunities for material processing control. Published by the American Physical Society 2025

Wang, Tianhong (ORCID:0000000169104201)↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spallation Neutron Source Proton Power Upgrade (PPU) Project: Lessons Learned for CD-4

The SNS PPU project goals were to design, build, install and test the equipment necessary to double the accelerator power from 1.4 MW to 2.8 MW and to deliver a 2.0 MW qualified target. PPU also included the provision of a stub-out in the SNS accumulator-ring-to-target tunnel to facilitate a rapid connection to a new proton beamline for the Second Target Station (STS) project. The power capability was doubled by increasing the proton beam energy by 33% and the peak beam current by 50%, relative to pre-PPU accelerator performance. The project also included modifications to some buildings and services. The PPU project accomplished the energy upgrade by fabricating and installing new superconducting radiofrequency (RF) cryomodules, with supporting RF equipment, in the existing linac tunnel and klystron gallery, respectively. The High Voltage Converter Modulators (HVCM) and klystrons for some of the existing installed RF equipment were upgraded to handle the higher beam current. The increased beam power of 2 MW on the First Target Station (FTS) was enabled by the addition of a new high-volume gas injection system for pressure pulse and cavitation mitigation in the mercury target and a redesigned mercury target vessel.

43 PARTICLE ACCELERATORS↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Measurement of the Neutron Elastic Electromagnetic Form Factor Ratio at Large Momentum Transfer

Exploring nucleon structure is vital both for understanding its origin and existence as well as for the advancement of the sciences. It helps us answer key questions such as how quark and gluon dynamics create 99% of the nucleon mass. Electron- nucleon scattering has been widely used for precision studies of the nucleon and nuclear structure since the Nobel Prize winning investigations by Robert Hofstadter and collaborators in the 1950s. These studies provide information about the spatial charge and current densities of the nucleon in terms of the electromagnetic form factors. The form factors are functions of four momentum transfer squared (Q2). Extending the electromagnetic form factor measurements to higher Q2 plays a critical role in furthering the understanding of nucleon structure. This motivated the Super BigBite Spectrometer (SBS) program at Jefferson Lab. The open nature of the spectrometers and the direct line of sight from the target to the tracking detector locations in experimental setups such as SBS creates high levels of background at the detectors. This necessitates the use of tracking detectors with high rate capability and good position resolution. Gas Electron Multiplier (GEM) detectors are an excellent choice for tracking detectors in such experiments. Understanding the performance of the GEM detectors is important not just for SBS experiments but also for future high-luminosity experiments. This thesis reports the exploratory results from the measurement of the neutron elastic electromagnetic form factor ratio (Gn E/Gn M) at high momentum transfer. A longitudinally polarized electron beam was scattered off a polarized 3He target, used as an effective polarized neutron target. In this experiment, the polarized 3He target achieved a world record polarization weighted luminosity at a beam current of 45 µA. Double spin asymmetry of the scattered neutron events is used to extract the neutron form factor ratio. Measurements were taken at Q2 = 3.0, 6.8, 9.8 (GeV/c)2. The lowest Q2 measurement is in good agreement with the existing world data, and the higher-Q2 measurements extend the Q2 reach well beyond the existing world data and are expected to remain unmatched for a long time.

Gamage, Vimukthi Haththotuwa [Univ. of Virginia, C↗

A simple method for mitigating error in the fixed-offset of a double-crystal monochromator

In order to maintain a constant monochromatic synchrotron X-ray beam height for all energies, the separation between the crystals of a double-crystal monochromator is typically adjusted, via translation of the second crystal, while X-ray energy is varied, via rotation of the crystal pair. The ability to accurately translate the second crystal requires precise knowledge of the separation between the two crystals and, when present, crystal miscuts. Here, a simple method for calibrating the crystal gap from measured variation in the X-ray beam height that eliminates error in the fixed beam offset is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Online Optimization of NSLS-II Dynamic Aperture and Injection Transient (Facility Improvement Project)

The Facility Improvement Project (FIP) “Methods of online optimization of NSLS-II storage ring concurrent with user operations” proposed and approved in 2018 is now complete. The first goal is the online optimization of nonlinear beam dynamics to increase the beam lifetime and injection efficiency. We have developed a model-independent optimization technique using advanced algorithms. Using this technique, we increased the NSLS-II dynamic aperture by 20% and reduced the amplitude-dependent tune shift by a factor of two. We applied sextupole optimization to the new high-chromaticity lattice, which has been developed to improve the beam stability and to increase the single-bunch beam intensity. We were able to double the injection efficiency and exceed 90%. The second goal of this project is to provide the top-off injection with minimized perturbations of the beamline user operations. To achieve the transparent injection, we optimize the matching of four storage ring injection kickers reducing the perturbation of the stored beam orbit. The first application of the online optimization resulted in a reduction of the amplitude of residual beam oscillation by a factor of six, from 1300 μm down to 200 μm. Further improvement was limited by the timing jitter of the trigger boards. Then, we replaced all trigger boards with a new design and reduced the timing jitter by a factor of five, from 5 ns down to 1 ns. This upgrade resulted in the injection transient reduction from 200 μm to 120 μm. To optimize the full set of kicker parameters, including the trigger timing, amplitude, and pulse width, we upgraded all kicker power supplies with the capability of tunable waveform width. As a result, we have reduced the injection transient to the limit of 60 μm.

43 PARTICLE ACCELERATORS↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Design progress for the 22 GeV CEBAF energy upgrade

In this work we examine the progress made in the design of the proposed FFA upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF). This proposed upgrade will double the number of passes through the two linacs by replacing the two highest energy arcs with new Fixed Field Alternating Gradient (FFA) arcs, roughly doubling the energy. These FFA arcs will use permanent magnets in a Halbach configuration to shape their fields. The design involves new optics for the linacs and remaining electromagnetic arcs, as well as new electromagnetic separators. These feed into the permanent magnet FFA arcs. We also report on ongoing studies of the dynamics of the beams, and an experiment to measure the effects of radiation on the permanent magnets.

Accelerator Physics↗

A renewable double plasma mirror for Petawatt-class lasers

Exceptional pulse contrast can be critical for ultraintense laser experiments, particularly when using solid density targets, and their use is becoming widespread. However, current plasma mirror technology is becoming inadequate for the new generation of high repetition rate, high power lasers now available. We describe a novel double plasma mirror configuration based on renewable, free standing, ultrathin liquid crystal films tested at the BELLA Petawatt Laser Center. Although operating at a repetition rate of several shots per minute, this system can be scaled to a high repetition rate exceeding 1 Hz and represents an important step towards enabling sustained, continuous operation of plasma mirrors. We demonstrate an improvement of two to three orders of magnitude in contrast and a total throughput of 80%. We present the first measurements of a beam reflected from a single or double plasma mirror system using a wavefront sensor, showing a well preserved wavefront and spatial mode. Finally, we introduce a model that predicts the total throughput through this double plasma mirror. This is the first model that accurately predicts the peak reflectivity of a plasma mirror when given the laser temporal profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incident beamline design for a modern cold triple axis spectrometer at the High Flux Isotope Reactor

A modern cold triple axis spectrometer is being planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the design of an incident beamline that will put a flux of ~ 10 8 $\frac {n}{cm^{2}s}$ on a sample with an area of 2 cm X 2 cm. It takes current physical constraints at HFIR into account and it can accommodate both single and multiplexed analyzer-detector secondary spectrometers and large superconducting magnets. The proposed incident beamline includes a multi-channel guide with horizontal focusing, a neutron velocity selector, components to facilitate an incident beam polarization option, and a double-focusing pyrolytic graphite monochromator. Here, this work describes the process of optimizing the guide system and monochromator and summarizes the expected performance of the incident beamline for non-polarized operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗