Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of PBR Spent Fuel Criticality and Dose Rate Compliance for Storage and Transportation

Spent tri-structural isotropic (TRISO)–based fuels have a strong track record in storage and transportation without documented incidents. This work seeks to reduce uncertainty to aid in more informed spent fuel management of TRISO-based fuels by modeling both fresh and spent pebble bed reactor (PBR) fuel and comparing the results to the regulatory standards from 10 CFR 71. SCALE was used for all modeling due to it having fast and accurate methods for handling PBR fuel modeling, as well as having an efficient method for shielding calculations in monaco with automated variance reduction using importance calculations (MAVRIC), which utilizes the consistent adjoint-driven importance sampling (CADIS) and the forward-weighted consistent adjoint-driven importance sampling (FW-CADIS) methods. KENO-VI was used for all criticality calculations, TSUNAMI was used for uncertainty quantification on k-effective, TRITON and the Oak Ridge isotope generation code (ORIGEN) were both used for depletion of the fuel, and MAVRIC was used for shielding calculations. For criticality assessments, this study focused on the requirement that the value of the neutron multiplication factor, k-effective (k-eff), would not exceed a peak value of 0.95, including uncertainty, with 95% confidence. Criticality was initially examined by modeling fresh fuel from three different designs—HTR-10 fuel, PBMR-400 fuel, and demonstration fuel representative of a TRISO-fueled modern high-temperature gas reactor (HTGR) design, henceforth referred to as Demo HTGR—and placing them into various sized containers with conditions described in 10 CFR 71 to quantify the peak k-eff state. When the peak value of 0.95 k-eff was exceeded, mitigation methods were examined in those scenarios. Burnup credit, pebble displacement in areas of strong neutron multiplication, and random pebble replacement using pebbles of various compositions and replacement fractions were examined. In summary, the criticality of PBR fuels can be well accounted for by restricting container size, taking credit for burnup, or by displacing/replacing pebbles. Uncertainty of the k-eff due to nuclear data uncertainties was recorded at ~0.6644%Δk/k, or roughly 664% mil (pcm). The nuclear data–induced uncertainty was relatively small and should not require significant modification in the design to be accounted for. Revisions to the evaluated nuclear data file values have been shown to have a larger impact than nuclear data–induced uncertainty. For dose rate aspects, U.S. Nuclear Regulatory Commission regulations require a maximum dose rate of 10 millirem per hour (mrem/h) at 2 meters. In examining the dose rate behavior of spent PBR fuel, the representative Demo HTGR fuel was modeled exclusively due to it possessing the highest target burnup of the examined fuels. Equilibrium cycle modeling methods were used to produce a higher-fidelity discharge isotopic composition than simple assumptions, such as reflected pebbles. The discharge composition was used as a source term in the fixed-source transport shielding calculations, and dose rates were calculated at 2 m for the shortest possible cooling time. The low concentration of fuel material led to dose rates that were in line with regulatory limits, despite the high burnup when compared to traditional light water reactor fuels. In conclusion, the methods employed in this study would require more work to further verify and validate and are limited to the criticality and dose rate analyses performed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deciphering Time-Dependent DNA Damage Complexity, Repair, and Oxygen Tension: A Mechanistic Model for FLASH-Dose-Rate Radiation Therapy

Irradiation with ultrahigh dose rates (FLASH) has reemerged as a promising radiation therapy approach to effectively lower potential damage burden on normal tissue without sacrificing tumor control. However, the large number of recent FLASH studies have been conducted under vastly different experimental conditions and circumstances (ie, investigated biological endpoint, radiation quality, and environmental oxygen level), with unverified biological mechanisms of action and unexplored interplay effect of the main dependencies. To facilitate radiobiological investigation of FLASH phenomena and assessment of clinical applicability, we present an extension of the mechanistic radiobiological model “UNified and VERSatile bio response Engine” (UNIVERSE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

NASA Discipline Radiation Health↗

The Effects of ELDRS at Ultra-Low Dose Rates

We present results of ultra-low dose-rate irradiations on a variety of commercial and radiation hardened bipolar circuits. We observed enhanced degradations at dose rates lower than 10 mrad(Si)/s in some devices.

Chen, Dakai↗

Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

Long, Edward R., Jr.↗

Dose and dose rate effects of whole-body proton irradiation on leukocyte populations and lymphoid organs: part I

The goal of part I of this study was to evaluate the effects of whole-body proton irradiation on lymphoid organs and specific leukocyte populations. C57BL/6 mice were exposed to the entry region of the proton Bragg curve to total doses of 0.5 gray (Gy), 1.5 Gy, and 3.0 Gy, each delivered at a low dose rate (LDR) of 1 cGy/min and high dose rate (HDR) of 80 cGy/min. Non-irradiated and 3 Gy HDR gamma-irradiated groups were included as controls. At 4 days post-irradiation, highly significant radiation dose-dependent reductions were observed in the mass of both lymphoid organs and the numbers of leukocytes and T (CD3(+)), T helper (CD3(+)/CD4(+)), T cytotoxic (CD3(+)/CD8(+)), and B (CD19(+)) cells in both blood and spleen. A less pronounced dose effect was noted for natural killer (NK1.1(+) NK) cells in spleen. Monocyte, but not granulocyte, counts in blood were highly dose-dependent. The numbers for each population generally tended to be lower with HDR than with LDR radiation; a significant dose rate effect was found in the percentages of T and B cells, monocytes, and granulocytes and in CD4(+):CD8(+) ratios. These data indicate that mononuclear cell response to the entry region of the proton Bragg curve is highly dependent upon the total dose and that dose rate effects are evident with some cell types. Results from gamma- and proton-irradiated groups (both at 3 Gy HDR) were similar, although proton-irradiation gave consistently lower values in some measurements.

Non-NASA Center↗

Revealing low-temperature plasma efficacy through a dose-rate assessment by DNA damage detection combined with machine learning models

Low-temperature plasmas have quickly emerged as alternative and unconventional types of radiation that offer great promise for various clinical modalities. As with other types of radiation, the therapeutic efficacy and safety of low-temperature plasmas are ubiquitous concerns, and assessing their dose rates is crucial in clinical settings. Unfortunately, assessing the dose rates by standard dosimetric techniques has been challenging. To overcome this difficulty, we proposed a dose-rate assessment framework that combined the predictive modeling of plasma-induced damage in DNA by machine learning with existing radiation dose-DNA damage correlations. Our results indicated that low-temperature plasmas have a remarkably high dose rate that can be tuned by various process parameters. This attribute is beneficial for inducing radiobiological effects in a more controllable manner.

59 BASIC BIOLOGICAL SCIENCES↗

Critical target and dose and dose-rate responses for the induction of chromosomal instability by ionizing radiation

To investigate the critical target, dose response and dose-rate response for the induction of chromosomal instability by ionizing radiation, bromodeoxyuridine (BrdU)-substituted and unsubstituted GM10115 cells were exposed to a range of doses (0.1-10 Gy) and different dose rates (0.092-17.45 Gy min(-1)). The status of chromosomal stability was determined by fluorescence in situ hybridization approximately 20 generations after irradiation in clonal populations derived from single progenitor cells surviving acute exposure. Overall, nearly 700 individual clones representing over 140,000 metaphases were analyzed. In cells unsubstituted with BrdU, a dose response was found, where the probability of observing delayed chromosomal instability in any given clone was 3% per gray of X rays. For cells substituted with 25-66% BrdU, however, a dose response was observed only at low doses (<1.0 Gy); at higher doses (>1.0 Gy), the incidence of chromosomal instability leveled off. There was an increase in the frequency and complexity of chromosomal instability per unit dose compared to cells unsubstituted with BrdU. The frequency of chromosomal instability appeared to saturate around approximately 30%, an effect which occurred at much lower doses in the presence of BrdU. Changing the gamma-ray dose rate by a factor of 190 (0.092 to 17.45 Gy min(-1)) produced no significant differences in the frequency of chromosomal instability. The enhancement of chromosomal instability promoted by the presence of the BrdU argues that DNA comprises at least one of the critical targets important for the induction of this end point of genomic instability.

NASA Discipline Radiation Health↗

The Effect of Dose Rate on Composite Durability When Exposed to a Simulated Long-Term Lunar Radiation Environment

Human exploration of space beyond low Earth orbit (LEO) requires a safe living and working environment for crew. Composite materials are one type of material being investigated by NASA as a multi-functional structural approach to habitats for long-term use in space or on planetary surfaces with limited magnetic fields and atmosphere. These materials provide high strength with the potential for decreased weight and increased radiation protection of crew and electronics when compared with conventional aluminum structures. However, these materials have not been evaluated in a harsh radiation environment, as would be experienced outside of LEO or on a planetary surface. Thus, NASA has been investigating the durability of select composite materials in a long-term radiation environment. Previously, NASA exposed composite samples to a simulated, accelerated 30-year radiation treatment and tensile stresses similar to those of a habitat pressure vessel. The results showed evidence of potential surface oxidation and enhanced cross-linking of the matrix. As a follow-on study, we performed the same accelerated exposure alongside an exposure with a decreased dose rate. The slower dose ]rate is comparable to a realistic scenario, although still accelerated. Strain measurements were collected during exposure and showed that with a fastdose rate, the strain decreased with time, but with a slow ]dose rate, the strain increased with time. After the radiation exposures, samples were characterized via tensile tests, flexure tests, Fourier Transform Infrared Spectroscopy (FTIR), and Differential Scanning Calorimetry (DSC). The results of these tests will be discussed.

Rojdev, Kristina↗

M-BAND Analysis of Chromosome Aberration In Human Epithelial Cells exposed to Gamma-ray and Secondary Neutrons of Low Dose Rate

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's "30L" beam line is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams at an entrance dose rate of 2.5 cGy/hr or gamma-ray at 1.7cGy/hr, and assessed the induction of chromosome aberrations that were identified with mBAND. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results for gamma-rays and 600 MeV/nucleon Fe ions of high dose rate, the neutron data showed a higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. The low dose rate gamma-rays induced a lower frequency of chromosome aberrations than high dose rate gamma-rays, but the inversion spectrum was similar for the same cytotoxic effect. The distribution of damage sites on chromosome 3 for different radiation types will also be discussed.

Hada, M.↗

FLASH Dose Rate Helium Ion Beams: First In Vitro Investigations

To establish and investigate the effects of dose, linear energy transfer (LET), and O{sub 2} concentration on biologic response to ultrahigh dose rate (uHDR; FLASH) helium ion beams compared with standard dose rate (SDR) irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Dose and dose rate effects of whole-body proton-irradiation on lymphocyte blastogenesis and hematological variables: part II

The goal of part II of this study was to evaluate functional characteristics of leukocytes and circulating blood cell parameters after whole-body proton irradiation at varying doses and at low- and high-dose-rates (LDR and HDR, respectively). C57BL/6 mice (n=51) were irradiated and euthanized at 4 days post-exposure for assay. Significant radiation dose- (but not dose-rate-) dependent decreases were observed in splenocyte responses to T and B cell mitogens when compared to sham-irradiated controls (P<0.001). Spontaneous blastogenesis, also significantly dose-dependent, was increased in both blood and spleen (P<0.001). Red blood cell counts, hemoglobin concentration, and hematocrit were decreased in a dose-dependent manner (P<0.05), whereas thrombocyte numbers were only slightly affected. Comparison of proton- and gamma-irradiated groups (both receiving 3 Gy at HDR) showed a higher level of spontaneous blastogenesis in blood leukocytes and a lower splenocyte response to concanavalin A following proton irradiation (P<0.05). There were no dose rate effects. Collectively, the data demonstrate that the measurements in blood and spleen were largely dependent upon the total dose of proton radiation and that an 80-fold difference in the dose rate was not a significant factor. A difference, however, was found between protons and gamma-rays in the degree of change induced in some of the measurements.

Non-NASA Center↗

Estimation of General Area Dose Rates During Closure Weld Operations on the DOE Standard Canister Pacific Basin Nuclear Conference 2024

The Department of Energy (DOE) Spent Nuclear Fuel (SNF) Road Ready Demonstration Project is an effort to package DOE-managed SNF for road-ready dry storage. A key operation in this demonstration is performing the closure weld on the DOE Standard Canister after it has been loaded with the SNF. Planning the closure weld operations is ongoing and must consider what parts of the operations (if any) can be done manually and what parts must be done remotely. A key parameter to inform the evolving planning of these operations is the dose rate in the vicinity of the canister and the dose hazard posed to the closure weld operators and collocated workers. This study developed a Monte Carlo N-Particle (MCNP) model of the closure weld operation, which was used to estimate general area dose rates as well as dose rates to the welding location, weld operators, and collocated workers. These estimates provide some insight into the potential radiation exposure hazard for workers during the operations and are a factor to be considered in the ongoing development of designs, technology, processes, and administrative controls for packaging DOE-managed SNF for road-ready dry storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of dose rate on the phase stability of a CrFeNiMn alloy

We report CrFeNi-based multi-principal element alloys (MPEAs) are being considered for nuclear applications because of their potentially superior mechanical properties and irradiation resistance. While the alloys appear stable against phase decomposition during ion irradiation performed at high dose rate, previous electron irradiation and thermal annealing studies suggested that some of them may be susceptible to phase decomposition. Therefore, to clarify the role of dose rate during ion irradiation on phase decomposition, a CrFeNiMn alloy was irradiated using Fe ions at 500 °C with an intermediate dose rate of 10 -4 dpa/s. Transmission electron microscopy and atom probe tomography observations revealed a high number density of NiMn precipitates, cavities, and dislocation loops, which had not previously been observed after ion irradiation at higher dose rates.

36 MATERIALS SCIENCE↗

Measured vs. Calculated Dose Rates During Ring Injection Dump Replacement

One of the most irradiated Spallation Neutron Source (SNS) accelerator components is the ring injection dump (RID), which is located downstream of the accumulator ring injection section. The unstripped and only partially stripped H - beam, about 5% of the full SNS beam current, is discarded in the injection into the accumulator ring and is redirected to the RID. According to the accelerator operation plan, the beam stop and the window assemblies of the existing RID are removed and replaced when they have reached their end-of-life owing to radiation exposure. This procedure, which includes multiple steps, took place during a facility maintenance period in March 2023. To support work planning and meet as low as reasonably achievable (ALARA) requirements during removal and exchange of the components, dose rates were calculated for each stage of the exchange operation. During each stage, dose rates were measured before and after work. This comparison shows that measured dose rates are within a factor of 2 of the predicted (calculated) dose rates.

43 PARTICLE ACCELERATORS↗

Comparison of residual dose rates from MARS and DORIAN simulations with experimental data from the SINBAD database

This benchmarking study aims to compare residual dose rate predictions from the MARS and DORIAN codes with experimental measurements taken from samples irradiated at CERN's CERF facility. The research evaluates the residual dose rates of these samples over varied cooling intervals. Additionally, it delves into the influence of parameter choices, such as specific physics processes and energy thresholds, on the production and transport of particles and their effects on simulation outcomes. While both MARS and DORIAN largely align with experimental findings, discrepancies were observed in the copper sample. This prompted an in-depth examination of the elevated dose rates from MARS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗