Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Dogs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of posture on blood flow diversion by hypoxic pulmonary vasoconstriction in dogs

We used differential excretion of sulphur hexafluoride from the left and right lung to measure blood flow diversion by hypoxic pulmonary vasoconstriction (HPV) in the prone and supine positions in dogs (n = 9). Gas exchange was assessed using the multiple inert gas elimination technique. Blood flow diversion from the hypoxic (3% oxygen) left lung was mean 70.7 (SD 11.2)% in the supine compared with 57.0 (12.1)% in the prone position (P < 0.02). The supine position was associated with increased perfusion to low VA/Q regions (P < 0.05). The increased flow diversion with hypoxia in the supine position was associated with more ventilation to high VA/Q regions (P < 0.05). We conclude that flow diversion by hypoxic pulmonary vasoconstriction is greater in the supine position. This effect could contribute to the variable response in gas exchange with positioning in patients with ARDS.

Non-NASA Center

Redistribution of pulmonary blood flow during unilateral hypoxia in prone and supine dogs

We used fluorescent-labeled microspheres in pentobarbital-anesthetized dogs to study the effects of unilateral alveolar hypoxia on the pulmonary blood flow distribution. The left lung was ventilated with inspired O2 fraction of 1.0, 0.09, or 0.03 in random order; the right lung was ventilated with inspired O2 fraction of 1.0. The lungs were removed, cleared of blood, dried at total lung capacity, then cubed to obtain approximately 1,500 small pieces of lung ( approximately 1.7 cm3). The coefficient of variation of flow increased (P < 0.001) in the hypoxic lung but was unchanged in the hyperoxic lung. Most (70-80%) variance in flow in the hyperoxic lung was attributable to structure, in contrast to only 30-40% of the variance in flow in the hypoxic lung (P < 0.001). When adjusted for the change in total flow to each lung, 90-95% of the variance in the hyperoxic lung was attributable to structure compared with 70-80% in the hypoxic lung (P < 0.001). The hilar-to-peripheral gradient, adjusted for change in total flow, decreased in the hypoxic lung (P = 0.005) but did not change in the hyperoxic lung. We conclude that hypoxic vasoconstriction alters the regional distribution of flow in the hypoxic, but not in the hyperoxic, lung.

NASA Discipline Cardiopulmonary

Vasopressin, renin, and cortisol responses to hemorrhage during acute blockade of cardiac nerves in conscious dogs

The effect of acute cardiac nerve blockade (CNB) on the increases in plasma renin activity (PRA), arginine vasopressin (AVP), and cortisol in response to a 30 ml/kg hemorrhage was determined in conscious dogs (n = 9). Procaine was infused into the pericardial space to produce acute reversible CNB, or saline was infused in the control hemorrhage. Blood was removed from the inferior vena cava at a rate of 1 ml.kg-1.min-1. In the control hemorrhage, plasma AVP increased from 1.8 +/- 0.3 to 219 +/- 66 pg/ml, PRA increased from 0.63 +/- 0.20 to 3.08 +/- 0.91 ng angiotensin I (ANG I).ml-1.3 h-1, and cortisol increased from 1.4 +/- 0.2 to 4.0 +/- 0.7 micrograms/dl. When the hemorrhage was repeated during acute CNB, plasma AVP increased from 2.8 +/- 1.6 to 185 +/- 59 pg/ml, PRA increased from 0.44 +/- 0.14 to 2.24 +/- 0.27 ng ANG I.ml-1.3 h-1, and cortisol increased from 1.9 +/- 0.3 to 5.4 +/- 0.6 micrograms/dl, and none of the increases differed significantly from the responses during the control hemorrhage. Left atrial pressure fell significantly after removal of 6 ml/kg of blood, but mean arterial pressure was maintained at control levels until blood loss reached 20 ml/kg during pericardial infusion of either saline or procaine. The declines in MAP at the 30 ml/kg level of hemorrhage in both treatments were similar. These results demonstrate that acutely blocking input from cardiac receptors does not reduce the increases in plasma AVP, cortisol, and PRA in response to a 30 ml/kg hemorrhage. The results of this study do not support the hypothesis that input from cardiac receptors is required for a normal AVP response to hemorrhage and suggest that other receptors, presumably arterial baroreceptors, can stimulate AVP and cortisol secretion in the absence of signals from the heart.

NASA Center ARC

Human IgE monoclonal antibodies define two unusual epitopes trapping dog allergen Can f 1 in different conformations

Abstract Molecular analysis of interactions between IgE antibody and allergen allows the structural basis of IgE recognition to be defined. Human IgE (hIgE) epitopes of respiratory lipocalin allergens, including Can f 1, remain elusive due to a lack of IgE‐allergen complexes. This study aims to map the structure of allergenic epitopes on Can f 1. The fragment antigen‐binding (Fab) regions of Can f 1 specific human IgE monoclonal antibodies (hIgE mAb) were used to determine the structures of IgE epitopes. Epitope mutants were designed to target Can f 1 epitopes. Immunoassays and a human FcεRIαtransgenic mouse model of passive anaphylaxis in vivo were used to assess the functional activity of epitope mutants. Crystal structures of natural or recombinant Can f 1 complexed with two hIgE mAb 1J11 and 12F3 Fabs, respectively, were determined. The hIgE mAb bound to two partially overlapping epitopes and recognized two different Can f 1 conformations. The hIgE mAb 12F3 showed an unusual mode of binding by protruding its heavy chain CDR3 inside the Can f 1 calyx. Epitope mutants generated based on the structural analyses displayed a 64%–89% reduction in IgE antibody binding and failed to induce passive anaphylaxis in a human FcεRIαtransgenic mouse model. In summary, the structures of Can f 1‐hIgE Fab complexes revealed two unique and partially overlapping epitopes on Can f 1. The modification of the identified IgE epitopes provides a pathway for the design of hypoallergens to treat dog allergies.

Biochemistry & Molecular Biology

An outbreak of renal failure in asian dogs due to s-triazine adulteration of pet food raw material: Analysis of unique, green kidney stones formed as a result

Renoliths were removed at necropsy from dogs that had died from acute kidney injury in Asia in 2004 and submitted to our laboratories for analysis including elemental composition, mass spectrometry, and microprobe analysis. The presence of a mixed s-triazine matrix comprising melamine, cyanuric acid, and ammelide, but no detectable ammeline, was found in the stone samples we analyzed. The unusual and unique green coloration of these stones was determined to be due to the presence of biliverdin. The occurrence of these green stones distinguished the 2004 incident from another incident in 2007 in the USA and other reported cases. The presence of crystals was reported in renal tubules and collecting ducts in both outbreaks, but no stones were reported in the 2007 incident. Here, this difference suggested a variation in the disease process caused by mixed s- triazine ingestion. Careful monitoring of food additives is warranted to prevent future problems in animals and humans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Deep learning models for interpretation of point of care ultrasound in military working dogs

Introduction: Military working dogs (MWDs) are essential for military operations in a wide range of missions. With this pivotal role, MWDs can become casualties requiring specialized veterinary care that may not always be available far forward on the battlefield. Some injuries such as pneumothorax, hemothorax, or abdominal hemorrhage can be diagnosed using point of care ultrasound (POCUS) such as the Global FAST® exam. This presents a unique opportunity for artificial intelligence (AI) to aid in the interpretation of ultrasound images. In this article, deep learning classification neural networks were developed for POCUS assessment in MWDs. Methods: Images were collected in five MWDs under general anesthesia or deep sedation for all scan points in the Global FAST® exam. For representative injuries, a cadaver model was used from which positive and negative injury images were captured. A total of 327 ultrasound clips were captured and split across scan points for training three different AI network architectures: MobileNetV2, DarkNet-19, and ShrapML. Gradient class activation mapping (GradCAM) overlays were generated for representative images to better explain AI predictions. Results: Performance of AI models reached over 82% accuracy for all scan points. The model with the highest performance was trained with the MobileNetV2 network for the cystocolic scan point achieving 99.8% accuracy. Across all trained networks the diaphragmatic hepatorenal scan point had the best overall performance. However, GradCAM overlays showed that the models with highest accuracy, like MobileNetV2, were not always identifying relevant features. Conversely, the GradCAM heatmaps for ShrapML show general agreement with regions most indicative of fluid accumulation. Discussion: Overall, the AI models developed can automate POCUS predictions in MWDs. Preliminarily, ShrapML had the strongest performance and prediction rate paired with accurately tracking fluid accumulation sites, making it the most suitable option for eventual real-time deployment with ultrasound systems. Further integration of this technology with imaging technologies will expand use of POCUS-based triage of MWDs.

59 BASIC BIOLOGICAL SCIENCES