Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dispensers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Systems and Methods for RFID-Enabled Dispenser

Methods, apparatuses and systems for radio frequency identification (RFID)-enabled information collection are disclosed, including an enclosure, a collector coupled to the enclosure, an interrogator, a processor, and one or more RFID field sensors, each having an individual identification, disposed within the enclosure. In operation, the interrogator transmits an incident signal to the collector, causing the collector to generate an electromagnetic field within the enclosure. The electromagnetic field is affected by one or more influences. RFID sensors respond to the electromagnetic field by transmitting reflected signals containing the individual identifications of the responding RFID sensors to the interrogator. The interrogator receives the reflected signals, measures one or more returned signal strength indications ("RSSI") of the reflected signals and sends the RSSI measurements and identification of the responding RFID sensors to the processor to determine one or more facts about the influences. Other embodiments are also described.

Fink, Patrick W.↗

Apparatus for Sampling Surface Contamination

An apparatus denoted a swab device has been developed as a convenient means of acquiring samples of contaminants from surfaces and suspending the samples in liquids. (Thereafter, the liquids can be dispensed, in controlled volumes, into scientific instruments for analysis of the contaminants.) The swab device is designed so as not to introduce additional contamination and to facilitate, simplify, and systematize the dispensing of controlled volumes of liquid into analytical instruments. The swab device is a single apparatus into which are combined all the equipment and materials needed for sampling surface contamination. The swab device contains disposable components stacked together on a nondisposable dispensing head. One of the disposable components is a supply cartridge holding a sufficient volume of liquid for one complete set of samples. (The liquid could be clean water or another suitable solvent, depending on the application.) This supply of liquid is sealed by Luer valves. At the beginning of a sampling process, the user tears open a sealed bag containing the supply cartridge. A tip on the nondisposable dispensing head is engaged with a Luer valve on one end of the supply cartridge and rotated, locking the supply cartridge on the dispensing head and opening the valve. The swab tip includes a fabric swab that is wiped across the surface of interest to acquire a sample. A sealed bag containing a disposable dispensing tip is then opened, and the swab tip is pushed into the dispensing tip until seated. The dispensing head contains a piston that passes through a spring-loaded lip seal. The air volume displaced by this piston forces the liquid out of the supply cartridge, over the swab, and into the dispensing tip. The piston is manually cycled to enforce oscillation of the air volume and thereby to cause water to flow to wash contaminants from the swab and cause the resulting liquid suspension of contaminants to flow into the dispensing tip. After several cycles to ensure adequate mixing, liquid containing the suspended contaminant sample is dispensed. The disposable components are then removed from the dispensing head, which may then be reused with a fresh set of disposable components.

Wells, Mark↗

Method for printing functional protein microarrays

Piezoelectric dispensing of proteins from borosilicate glass capillaries is a popular method of protein biochip fabrication that offers the advantages of sample recovery and noncontact with the printing substrate. However, little regard has been given to the quantitative aspects of dispensing minute volumes (1 nL or less) at the low protein concentrations (20 micrograms/mL or less) typically used in microprinting. Specifically, loss of protein sample due to nonspecific adsorption to the glass surface of the dispensing capillaries can limit the amount of protein delivered to the substrate. We demonstrate the benefits of a low ionic strength buffer containing the carrier protein BSA that effectively minimizes the ionic strength-dependent phenomenon of nonspecific protein adsorption to borosilicate glass. Over the concentration range of 20-2.5 micrograms/mL, the dispensing of a reference IgG in 10 mM PBS including 0.1% BSA resulted in the deposition of 3.6- to 44-fold more IgG compared to the deposition of IgG in standard 150 mM PBS in the absence of BSA. Furthermore, when the IgG was dispensed with carrier protein, the resulting spots exhibited a more uniform morphology. In a direct immunoassay for cholera toxin, capture antibody spots dispensed in 10 mM PBS containing 0.1% BSA produced fluorescent signals that were 2.8- to 4.3-fold more intense than antibody spots that were dispensed in 150 mM PBS without BSA. Interestingly, no differences were observed in the specific activities of the capture antibodies as a result of printing in the different buffers. The implications of these results on the future development of protein biochips are discussed.

Evaluation Studies↗

Method and system for aligning fibers during electrospinning

A method and system are provided for aligning fibers in an electrospinning process. A jet of a fiberizable material is directed towards an uncharged collector from a dispensing location that is spaced apart from the collector. While the fiberizable material is directed towards the collector, an elliptical electric field is generated via the electrically charged dispenser and an oppositely-charged control location. The field spans between the dispensing location and the control location that is within line-of-sight of the dispensing location, and impinges upon at least a portion of the collector. Various combinations of numbers and geometries of dispensers, collectors, and electrodes can be used.

Scott-Carnell, Lisa A.↗

DiskSat: Demonstration Mission for a Two-Dimensional Satellite Architecture

The DiskSat is a quasi-two-dimensional satellite bus architecture designed for applications requiring high power, large apertures, and/or high maneuverability in a low-mass satellite. A representative DiskSat structure is a composite flat panel, one meter in diameter and 2.5 cm thick. The volume is almost 20 liters, equivalent to a hypothetical 20U CubeSat, while the structural mass is less than 3 kg. The surface area is large enough to host over 200 W of solar cells without deployable solar panels. For launch, multiple DiskSats are stacked in a fully enclosed container/deployer using a simple mechanical interface and are released individually in orbit. The Aerospace Corporation, with the support of the NASA Space Technology Mission Directorate (STMD), is preparing a flight of four DiskSats for launch in 2024 to demonstrate the feasibility of both the dispenser and the DiskSat bus. In addition, the flight is expected to demonstrate several features of the DiskSat including the unprecedented high power-to-mass ratio, the maneuverability of the bus using low-thrust electric propulsion, and the ability to fly continuously in a low-drag orientation, enabling operations in very low Earth orbits (VLEO). The DiskSats will be launched in and deployed from a dispenser that provides a containerized rideshare environment; the dispenser fully encloses the DiskSats during launch and then opens to dispense the satellites one at a time once in orbit. The dispenser is modular in design and expandable from the capacity of four DiskSats for this flight to as many as 20 DiskSats for future flights. NASA STMD seeks disruptive and innovative technologies that could help lead to the next-generation systems for future science and exploration missions. DiskSat is a potentially disruptive technology leading to new, enabling architectures using ever-more capable small spacecraft. Data generated from this flight will inform the drafting of a DiskSat standard intended to encourage easy and frequent access to space, in the same manner as the CubeSat standard. DiskSat is expected to become a standard format for rideshare-compatible, high-power, maneuverable, low-mass satellites for Earth-orbit, cis-lunar, and deep space applications.

Richard Welle↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗

Drug providers’ perspectives on antibiotic misuse practices in eastern Ethiopia: a qualitative study

Objective Antibiotic misuse includes using them to treat colds and influenza, obtaining them without a prescription, not finishing the prescribed course and sharing them with others. Although drug providers are well positioned to advise clients on proper stewardship practices, antibiotic misuse continues to rise in Ethiopia. It necessitates an understanding of why drug providers failed to limit such risky behaviours. This study aimed to explore drug providers’ perspectives on antibiotic misuse practices in eastern Ethiopia. Setting The study was conducted in rural Haramaya district and Harar town, eastern Ethiopia. Design and participants An exploratory qualitative study was undertaken between March and June 2023, among the 15 drug providers. In-depth interviews were conducted using pilot-tested, semistructured questions. The interviews were transcribed verbatim, translated into English and analysed thematically. The analyses considered the entire dataset and field notes. Results The study identified self-medication pressures, non-prescribed dispensing motives, insufficient regulatory functions and a lack of specific antibiotic use policy as the key contributors to antibiotic misuse. We found previous usage experience, a desire to avoid extra costs and a lack of essential diagnostics and antibiotics in public institutions as the key drivers of non-prescribed antibiotic access from private drug suppliers. Non-prescribed antibiotic dispensing in pharmacies was driven by client satisfaction, financial gain, business survival and market competition from informal sellers. Antibiotic misuse in the setting has also been linked to traditional and ineffective dispensing audits, inadequate regulatory oversights and policy gaps. Conclusion This study highlights profits and oversimplified access to antibiotics as the main motivations for their misuse. It also identifies the traditional antibiotic dispensing audit as an inefficient regulatory operation. Hence, enforcing specific antibiotic usage policy guidance that entails an automated practice audit, a responsible office and insurance coverage for persons with financial limitations can help optimise antibiotic use while reducing resistance consequences.

General & Internal Medicine↗

Quantitative Risk Assessment for Fuel Cell Electric Bus Hydrogen Storage and Refueling Facility

It is necessary to understand the safety implications and risk mitigation options for fuel cell electric bus fleet deployment, especially for related facilities responsible for operations such as production, storage, compression, and dispensing of hydrogen for use by the buses. In this report, we present a quantitative risk assessment for a potential fuel cell electric bus fleet that was motivated by efforts to improve resilience at the Portland International Airport but can be applicable to a range of hydrogen case studies and use cases. We estimated risk for a facility that produces, stores, compresses, and dispenses hydrogen for the fleet of buses, with a focus on individual risk to people in terms of annual frequency of fatality. We considered the frequency of hydrogen leaks that could result in harmful physical outcomes like jet fires or explosions, and the consequences of those outcomes for people. We created customized fault trees to calculate the frequencies of different sizes of leaks and event sequence diagrams to calculate ignition probabilities for the various leak sizes. We also leveraged the HyRAM+ toolkit to use these inputs to calculate overall risk for the facility, which we separated into one section responsible for producing, storing, and compressing hydrogen, and one section responsible for dispensing the hydrogen to the buses. We found that the dispensing area seemed to have a higher risk than the production/storage/compression area of the facility, largely because of the inclusion of a component with a high leak frequency (the heat exchanger used to cool the hydrogen before entering the vehicle, to prevent overheating and expansion of hydrogen in the onboard tank). For the example production and refueling facility we evaluated and the data we used for the analysis, the leak frequency had a larger impact on the risk differences between the two sections on the facility, compared to the physical outcome consequence, which was slightly different due to the varying fuel conditions, but not substantially different. Actions can be taken to prevent these hazards (e.g., lowering leak frequencies in system components) or to mitigate the consequences if they do occur (e.g., installing barriers to protect people if ignition events occur). The choice of which actions to take depends not only on safety considerations but also on space, time, staffing, feasibility, and financial constraints. Therefore, the quantitative risk assessment approach can help understand relative risk contributions from different components, leak sizes, consequences, and human actions, to prioritize risk reduction strategies and balance these parameters. The outcomes of this report may be useful for a variety of stakeholders working in the hydrogen, transportation, vehicle, and aviation sector, including those responsible for aspects like facility design, operations, and regulations. There is not a single value of risk that determines whether a hypothetical system is “safe” or not. The insights about risk mitigations may be leveraged, and the quantitative risk assessment approach can be applied to other case studies to understand risk priorities and contributions specific to different FCEB and hydrogen facility uses.

08 HYDROGEN↗

Iodine generator for reclaimed water purification

The system disclosed is for controlling the iodine level in a water supply in a spacecraft. It includes an iodine accumulator which stores crystalline iodine, an electrochemical valve to control the input of iodine to the drinking water and an iodine dispenser. A pump dispenses fluid through the iodine dispenser and an iodine sensor to a potable water tank storage. The iodine sensor electronically detects the iodine level in the water, and through electronic means, produces a correction current control. The correction current control operates the electro-chemical iodine valve to release iodine from the iodine accumulator into the iodine dispenser.

Wynveen, R. A.↗

Space shuttle food system summary, 1981-1986

All food in the Space Shuttle food system was precooked and processed so it required no refrigeration and was either ready-to-eat or could be prepared for consumption by simply adding water and/or heating. A gun-type water dispenser and a portable, suitcase-type heater were used to support this food system during the first four missions. On STS-5, new rehydratable packages were introduced along with a needle-injection water dispenser that measured the water as it was dispensed into the packages. A modular galley was developed to facilitate the meal preparation process aboard the Space Shuttle. The galley initially flew on STS-9. A personal hygiene station, a hot or cold water dispenser, a convection oven, and meal assembly areas were included in the galley.

Stadler, Connie R.↗

Automation of Vapor-Diffusion Growth of Protein Crystals

Some improvements have been made in a system of laboratory equipment developed previously for studying the crystallization of proteins from solution by use of dynamically controlled flows of dry gas. The improvements involve mainly (1) automation of dispensing of liquids for starting experiments, (2) automatic control of drying of protein solutions during the experiments, and (3) provision for automated acquisition of video images for monitoring experiments in progress and for post-experiment analysis. The automation of dispensing of liquids was effected by adding an automated liquid-handling robot that can aspirate source solutions and dispense them in either a hanging-drop or a sitting-drop configuration, whichever is specified, in each of 48 experiment chambers. A video camera of approximately the size and shape of a lipstick dispenser was added to a mobile stage that is part of the robot, in order to enable automated acquisition of images in each experiment chamber. The experiment chambers were redesigned to enable the use of sitting drops, enable backlighting of each specimen, and facilitate automation.

Hamrick, David T.↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Identification of drug repurposing candidates for amyotrophic lateral sclerosis using electronic health records: a retrospective cohort study

Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease with a life expectancy of only 3–5 years and few approved treatments. To identify drug repurposing candidates for the treatment of ALS, we analysed the electronic health records (EHRs) of a large cohort of military veterans with ALS. We analysed the EHRs of individuals in the US Veterans Health Administration (VHA) database who were diagnosed with ALS between Jan 1, 2009 and Dec 31, 2019 to assess medication effects. Individuals without recorded prescriptions after the date of diagnosis were excluded. Two sets of criteria were applied to ascertain exposure. Exposure criteria A were met if the dispense date or the end date of the medication was within 12 months of ALS diagnosis and the end date was at least 6 months after the dispense date. Exposure criteria B were met if there were at least two dispenses within 6 months before diagnosis and 12 months after diagnosis. Propensity score-matched control groups were generated on the basis of confounders included in the EHR, with methodology of potential outcomes used to infer treatment effects. The primary outcome was death. A standard Cox proportional hazards analysis was done to assess association with survival. Survival was defined as the time from diagnosis date recorded in the EHR to death reported in the Department for Veterans Affairs Vital Status File. Follow-up survival time was censored on Dec 31, 2020, for those alive on this date. Downstream protein targets of drugs with clinically significant effects were analysed using the protein–protein interaction networks-based algorithm PathFX. The EHRs of 11 003 individuals with ALS in the VHA database were appropriate for analysis. 162 medications with treatment groups of 30 or more individuals were identified. Among these 162 medications, 27 were associated with statistically significant changes (≥0·1) in the hazard ratio (HR) for death. 18 of the medications were associated with a reduced HR for death (prolonged survival), and nine were associated with an increased HR for death (reduced survival). Drugs associated with reduced HR included HMG-CoA reductase inhibitors (simvastatin, pravastatin, lovastatin, and atorvastatin), PDE5 inhibitors (vardenafil and sildenafil), and α-adrenergic antagonists (tamsulosin and terazosin). The medications associated with an increased HR were drugs used either in the management of clinical features of ALS associated with poor outcomes or in end-of-life care. PathFx analysis identified a complex of proteins interacting with several of the identified drugs. To our knowledge, this analysis is the largest EHR-based study for identifying drug repurposing candidates for ALS. We identified several drugs that warrant further assessment as therapeutic options in ALS, as well as a protein network complex that might serve as a therapeutic target for ALS.

Reimer, Richard J. [Stanford Univ., CA (United Sta↗

Identifying spatiotemporal patterns in opioid vulnerability: investigating the links between disability, prescription opioids and opioid-related mortality

Background: The opioid crisis remains one of the most daunting and complex public health problems in the United States. This study investigates the national epidemic by analyzing vulnerability profiles of three key factors: opioid-related mortality rates, opioid prescription dispensing rates, and disability rank ordered rates. Methods: This study utilizes county level data, spanning the years 2014 through 2020, on the rates of opioid-related mortality, opioid prescription dispensing, and disability. To successfully estimate and predict trends in these opioid-related factors, we augment the Kalman Filter with a novel spatial component. To define opioid vulnerability profiles, we create heat maps of our filter’s predicted rates across the nation’s counties and identify the hotspots. In this context, hotspots are defined on a year-by-year basis as counties with rates in the top 5% nationally. Results: Our spatial Kalman filter demonstrates strong predictive performance. From 2014 to 2018, these predictions highlight consistent spatiotemporal patterns across all three factors, with Appalachia distinguished as the nation’s most vulnerable region. Starting in 2019 however, the dispensing rate profiles undergo a dramatic and chaotic shift. Conclusions: The initial primary drivers of opioid abuse in the Appalachian region were likely prescription opioids; however, it now appears that abuse is sustained by illegal drugs. Additionally, we find that the disabled subpopulation may be more at risk of opioid-related mortality than the general population. Public health initiatives must extend beyond controlling prescription practices to address the transition to and impact of illicit drug use.

60 APPLIED LIFE SCIENCES↗

MC Formula Protocol for H35HF Fueling (CRADA Final Report)

The National Renewable Energy Lab (NREL), Frontier Energy, and the industry partners worked together to help SAE J2601-5 develop an H35 high-flow (HF) medium-duty (MD) and heavy-duty (HD) fueling protocol. The team upgraded NREL's hydrogen filling simulations (H2FillS) model to accommodate an MC Formula fueling (t-final) table generation capability by leveraging NREL's high-performance computing system. Based on protocol boundary conditions (e.g., allowable maximum flow rate, range of storage system size) set by SAE J2601-5, the team generated the fueling tables and then validated the reliability of those tables by installing them on NREL's HD dispenser and ZBT's H35HF dispenser and then performing H35HF fueling experiments. Through the validation process, this team certified that the fueling tables generated were reliable to install in commercial H35HF dispensers and then performed H35HF fueling of commercial MD/HD vehicles.

08 HYDROGEN↗

Autonomous Hydrogen Fueling Station

This project “Autonomous Hydrogen Fueling Station” covered the autonomous refueling with both gaseous hydrogen and liquid hydrogen. The part on gaseous hydrogen focused on the development of an autonomous robotic fueling arm that would couple to a fuel cell engine for hydrogen refueling without guidance from the forklift operator and budget period. Research was also covered for the robotic fueling with a commercial vehicle. The second phase of the project created the baseline for an autonomous liquid hydrogen transfer system that would minimize boil off losses by operating at thermodynamically efficient state points. For the development of the robotic fueling arm, testing was conducted to establish a baseline measurement of the accuracy and repeatability of a human operator positioning a lift truck in front of a dispenser. The goal was to establish the range of motion required for an autonomous fueling mechanism to mate a hydrogen nozzle with a receptacle on a fuel cell system installed in a forklift. The final design comprised a selective compliance articulated robot arm (SCARA)-type mechanism with two arms for horizontal motion and a ball screw for vertical movement and color and LIDAR cameras were used for marker identification and proximity awareness to guide the robotic arm to its target receptacle. Initial tests resulted in 199 out of 200 successful attempts at autonomous coupling of the dispensing coupler and a fuel cell engine, without hydrogen. The dispenser prototype was modified to include tubing for both hydrogen fuel and air purge lines, but subsequent tests were confounded by the shoulder motor over current errors which limited the robot from getting to the fully inserted position to achieve a positive latch. Robotic hydrogen refueling was successfully demonstrated over 1.5 hours of testing, Plug completed 29 successful latches with an average number of 4 sequential latches before failure. However, a robot capable of placing the nozzle with more force is required for higher reliability. For budget period two, a small scale (10 kg / transfer) automated control system was designed that would operate valves to control pressure and flow of liquid nitrogen between a source and receiving tank with an aim to minimize boil off losses by operating at the most thermodynamically efficient state points. Control system logic flow and a P&ID were developed prior to system safety characterization via HAZOP. A control narrative and system state points were defined. Delays in approval for a change of project objective and procurement issues precluded the construction and test of the final prototype system.

08 HYDROGEN↗