Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DSC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison of [{sup 11}C]choline Positron Emission Tomography With T2- and Diffusion-Weighted Magnetic Resonance Imaging for Delineating Malignant Intraprostatic Lesions

Purpose: The purpose of this study was to compare the accuracy of [{sup 11}C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET. Methods and Materials: This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified on prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models. Results: The best automatic contouring method, 60% of the maximum SUV (SUV{sub 60}) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P<.001). The sensitivity and specificity values were 72% and 71% for SUV{sub 60}; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET. Conclusions: CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arm and shoulder muscle segmentation in axial MRI with UNet deep learning model

Quantifying individual upper-limb muscle volumes from MRI provides key insight into muscle-specific strength, deficits, and adaptations. Manual delineation is the gold standard but time‑intensive, and the performance of current deep learning approaches, particularly for small or anatomically complex muscles, remains incompletely characterized. We evaluated a state‑of‑the‑art deep learning framework across the entire upper limb and analyzed factors governing segmentation performance, with attention to the forearm. Three previously published MRI datasets (1.5 T, 3D GRE T1‑weighted; total n = 39) spanning young, middle‑aged, and older adults were curated and quality‑checked, including expert manual segmentations for 31 muscles. Following multiclass mask reconstruction, we trained three 3D nnU‑Net multiclass models matched to the muscle subsets present across datasets, using five‑fold cross‑validation and a composite Dice Similarity Coefficient (DSC) + cross entropy loss. Segmentation accuracy was assessed with DSC. Performance varied across muscles (mean DSC = 0.806 ± 0.098), ranging from 0.920 (Deltoid) to 0.461 (Extensor pollicis brevis). In uncertainty‑weighted regressions, muscle volume was positively associated with DSC (R2 = 0.36, p < 0.001), whereas training segmentation count and muscle orientation showed negligible associations (R2 ≤ 0.06). A weighted mixed‑effects model identified volume as the strongest evaluated predictor, explaining 23.9% of variance in DSC; orientation and training count each contributed <1%, leaving 61.5% unexplained. These results indicate that deep learning–based segmentation can accurately quantify muscle volume for many upper‑limb muscles but remains constrained for small, low‑contrast forearm muscles.

Gillespie, Samuel↗

Crystallization processes in Ge{sub 2}Sb{sub 2}Se{sub 4}Te glass

Highlights: • Crystallization kinetics of Ge{sub 2}Sb{sub 2}Se{sub 4}Te glass was studied in dependence on particle size by DSC. • All studied fractions were described in terms of the SB autocatalytic model. • Relatively high amount of Te enhances manifestation of bulk crystallization mechanisms. • XRD analysis of samples crystallized under different conditions showed correlation with DSC data. • XRD analysis revealed a new crystallization mechanism indistinguishable by DSC. - Abstract: Differential scanning calorimetry (DSC) and X-ray diffraction (XRD) analysis were used to study crystallization in Ge{sub 2}Sb{sub 2}Se{sub 4}Te glass under non-isothermal conditions as a function of the particle size. The crystallization kinetics was described in terms of the autocatalytic Šesták–Berggren model. An extensive discussion of all aspects of a full-scale kinetic study of a crystallization process was undertaken. Dominance of the crystallization process originating from mechanically induced strains and heterogeneities was confirmed. Substitution of Se by Te was found to enhance the manifestation of the bulk crystallization mechanisms (at the expense of surface crystallization). The XRD analysis showed significant dependence of the crystalline structural parameters on the crystallization conditions (initial particle size of the glassy grains and applied heating rate). Based on this information, a new microstructural crystallization mechanism, indistinguishable by DSC, was proposed.

36 MATERIALS SCIENCE↗

Thermodynamic analysis of a MEMS based differential scanning calorimeter model

Thin film based differential scanning calorimeter (DSC) was developed and utilized for the study of phase-transition kinetics in protein samples. In this paper, we proposed a MEMS based DSC model. The distance between the sample and reference cell was optimized based on the thermal analysis result. The influence of the response time to the shape of the DSC thermograms and the transition temperature was also studied systematically. Meanwhile, Lumry-Eyring model was used to investigate the relationship between the scanning rate and the transition temperature. The modeling result was verified by the lysozyme denaturation tests. This study provided a pathway for the optimization of MEMS based DSC array and the correction of the DSC thermograms.

47 OTHER INSTRUMENTATION↗

Water in Solutions of Chaotropic and Kosmotropic Salts: A Differential Scanning Calorimetry Investigation

We report the use of aqueous phase separations via aqueous biphasic systems (ABS) has been widely explored in the recent decades. For wider and more “intelligent” applications, it is important to look below the surface and study these systems thoroughly at a fundamental level. Two important questions still unsolved are how do polymers and ions of different types organize water (if they in fact they do so) and how does it affect the separation of phases? In the present work, differential scanning calorimetry (DSC) was used to relate ABS phase diagrams and the behavior of water in aqueous solutions containing kosmotropic salts (K 3 PO 4 or (NH 4 ) 2 SO 4 ), a chaotropic ionic liquid ([C 4 mim]Cl), or a polymer (PEG-2000), all of which are reported components of ABS, and their mixtures. Additional DSC transitions were observed for the two classes of salts which could be assigned based on the fundamental differences between their interactions with water, suggesting that it is the differences in the abilities of kosmotropic and chaotropic salts to interact with water which result in the phase separation phenomena observed. The DSC measurements of solutions of PEG-2000 and (NH 4 ) 2 SO 4 indicate that aqueous solutions of PEG-2000 supercool and potentially enter a glassy state that exhibits devitrification upon heating. The devitrified state exhibits a clear eutectic with water. Mixtures of the polymer and salt continue to exhibit all the features observed for the pure components. These results suggest that the mixtures are phase separated and consist of largely separate concentrated solutions of PEG-2000 and (NH 4 ) 2 SO 4 , indicating an entropy-driven phase separation. The DSC analysis of these systems further refines the understanding of kosmotropic and chaotropic solutes into more specific phenomena for each compound. Lastly, this work suggests that DSC can be used to understand the role of each salt/component in ABS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyte/Dye/TiO 2 Interfacial Structures of Dye-Sensitized Solar Cells Revealed by In Situ Neutron Reflectometry with Contrast Matching

The nature of an interfacial structure buried within a device assembly is often critical to its function. For example, the dye/TiO 2 interfacial structure that comprises the working electrode of a dye-sensitized solar cell (DSC) governs its photovoltaic output. These structures have been determined outside of the DSC device, using ex situ characterization methods; yet, they really should be probed while held within a DSC since they are modulated by the device environment. Dye/TiO 2 structures will be particularly influenced by a layer of electrolyte ions that lies above the dye self-assembly. We show that electrolyte/dye/TiO 2 interfacial structures can be resolved using in situ neutron reflectometry with contrast matching. Here, we find that electrolyte constituents ingress into the self-assembled monolayer of dye molecules that anchor onto TiO 2 . Some dye/TiO 2 anchoring configurations are modulated by the formation of electrolyte/dye intermolecular interactions. These electrolyte-influencing structural changes will affect dye-regeneration and electron-injection DSC operational processes. This underpins the importance of this in situ structural determination of electrolyte/dye/TiO 2 interfaces within representative DSC device environments.

14 SOLAR ENERGY↗

Effectiveness of dye sensitised solar cell under low light condition using wide band dye

Dye sensistised solar cell (DSC) based on nanocrystalline TiO{sub 2} has the potential to be used in indoor consumer power application. In realizing this, the DSC must be optimized to generate power under low lighting condition and under wider visible light range. The use of wide band dye N749 which has a wider spectrum sensitivity increases the photon conversion to electron between the visible light spectrums of 390nm to 700nm. This paper reports the study on the effectiveness of the dye solar cell with N749 dye under low light condition in generating usable power which can be used for indoor consumer application. The DSC was fabricated using fluorine doped tin oxide (FTO) glass with screen printing method and the deposited TiO{sub 2} film was sintered at 500°C. The TiO{sub 2} coated FTO glass was then soaked in the N749 dye, assembled into test cell, and tested under the standard test condition at irradiance of 1000 W/m{sup 2} with AM1.5 solar soaker. The use of the 43T mesh for the dual pass screen printing TiO{sub 2} paste gives a uniform TiO{sub 2} film layer of 16 µm. The low light condition was simulated using 1/3 filtered irradiance with the solar soaker. The fabricated DSC test cell with the N749 dye was found to have a higher efficiency of 6.491% under low light condition compared to the N719 dye. Under the standard test condition at 1 sun the N749 test cell efficiency is 4.55%. The increases in efficiency is attributed to the wider spectral capture of photon of the DSC with N749 dye. Furthermore, the use of N749 dye is more effective under low light condition as the V{sub OC} decrement is less significant compared to the latter.

14 SOLAR ENERGY↗

Structural basis of adhesive binding by desmocollins and desmogleins

Desmosomes are intercellular adhesive junctions that impart strength to vertebrate tissues. Their dense, ordered intercellular attachments are formed by desmogleins (Dsgs) and desmocollins (Dscs), but the nature of trans -cellular interactions between these specialized cadherins is unclear. Here, using solution biophysics and coated-bead aggregation experiments, we demonstrate family-wise heterophilic specificity: All Dsgs form adhesive dimers with all Dscs, with affinities characteristic of each Dsg:Dsc pair. Crystal structures of ectodomains from Dsg2 and Dsg3 and from Dsc1 and Dsc2 show binding through a strand-swap mechanism similar to that of homophilic classical cadherins. However, conserved charged amino acids inhibit Dsg:Dsg and Dsc:Dsc interactions by same-charge repulsion and promote heterophilic Dsg:Dsc interactions through opposite-charge attraction. Furthermore, these findings show that Dsg:Dsc heterodimers represent the fundamental adhesive unit of desmosomes and provide a structural framework for understanding desmosome assembly.

59 BASIC BIOLOGICAL SCIENCES↗

Toward accurate tooth segmentation from computed tomography images using a hybrid level set model

Purpose: A three-dimensional (3D) model of the teeth provides important information for orthodontic diagnosis and treatment planning. Tooth segmentation is an essential step in generating the 3D digital model from computed tomography (CT) images. The aim of this study is to develop an accurate and efficient tooth segmentation method from CT images. Methods: The 3D dental CT volumetric images are segmented slice by slice in a two-dimensional (2D) transverse plane. The 2D segmentation is composed of a manual initialization step and an automatic slice by slice segmentation step. In the manual initialization step, the user manually picks a starting slice and selects a seed point for each tooth in this slice. In the automatic slice segmentation step, a developed hybrid level set model is applied to segment tooth contours from each slice. Tooth contour propagation strategy is employed to initialize the level set function automatically. Cone beam CT (CBCT) images of two subjects were used to tune the parameters. Images of 16 additional subjects were used to validate the performance of the method. Volume overlap metrics and surface distance metrics were adopted to assess the segmentation accuracy quantitatively. The volume overlap metrics were volume difference (VD, mm{sup 3}) and Dice similarity coefficient (DSC, %). The surface distance metrics were average symmetric surface distance (ASSD, mm), RMS (root mean square) symmetric surface distance (RMSSSD, mm), and maximum symmetric surface distance (MSSD, mm). Computation time was recorded to assess the efficiency. The performance of the proposed method has been compared with two state-of-the-art methods. Results: For the tested CBCT images, the VD, DSC, ASSD, RMSSSD, and MSSD for the incisor were 38.16 ± 12.94 mm{sup 3}, 88.82 ± 2.14%, 0.29 ± 0.03 mm, 0.32 ± 0.08 mm, and 1.25 ± 0.58 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the canine were 49.12 ± 9.33 mm{sup 3}, 91.57 ± 0.82%, 0.27 ± 0.02 mm, 0.28 ± 0.03 mm, and 1.06 ± 0.40 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the premolar were 37.95 ± 10.13 mm{sup 3}, 92.45 ± 2.29%, 0.29 ± 0.06 mm, 0.33 ± 0.10 mm, and 1.28 ± 0.72 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the molar were 52.38 ± 17.27 mm{sup 3}, 94.12 ± 1.38%, 0.30 ± 0.08 mm, 0.35 ± 0.17 mm, and 1.52 ± 0.75 mm, respectively. The computation time of the proposed method for segmenting CBCT images of one subject was 7.25 ± 0.73 min. Compared with two other methods, the proposed method achieves significant improvement in terms of accuracy. Conclusions: The presented tooth segmentation method can be used to segment tooth contours from CT images accurately and efficiently.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRA-04: Evaluation of An Atlas-Based Segmentation Method for Prostate and Peripheral Zone Regions On MRI

Purpose: Prostate MRI plays an important role in diagnosis, biopsy guidance, and therapy planning for prostate cancer. Prostate MRI contours can be used to aid in image fusion for ultrasound biopsy guidance and delivery of radiation. Our goal in this study is to evaluate an automatic atlas-based segmentation method for generating prostate and peripheral zone (PZ) contours on MRI. Methods: T2-weighted MRIs were acquired on 3T-Discovery MR750 System (GE, Milwaukee). The Volumes of Interest (VOIs): prostate and PZ were outlined by an expert radiation oncologist and used to create an atlas library for atlas-based segmentation. The atlas-segmentation accuracy was evaluated using a leave-one-out analysis. The method involved automatically finding the atlas subject that best matched the test subject followed by a normalized intensity-based free-form deformable registration of the atlas subject to the test subject. The prostate and PZ contours were transformed to the test subject using the same deformation. For each test subject the three best matches were used and the final contour was combined using Majority Vote. The atlas-segmentation process was fully automatic. Dice similarity coefficients (DSC) and mean Hausdorff values were used for comparison. Results: VOIs contours were available for 28 subjects. For the prostate, the atlas-based segmentation method resulted in an average DSC of 0.88+/−0.08 and a mean Hausdorff distance of 1.1+/−0.9mm. The number of patients (#) in DSC ranges are as follows: 0.60–0.69(1), 0.70–0.79(2), 0.80–0.89(13), >0.89(11). For the PZ, the average DSC was 0.72+/−0.17 and average Hausdorff of 0.9+/−0.9mm. The number of patients (#) in DSC ranges are as follows: <0.60(4), 0.60–0.69(6), 0.70–0.79(7), 0.80–0.89(9), >0.89(1). Conclusion: The MRI atlas-based segmentation method achieved good results for both the whole prostate and PZ compared to expert defined VOIs. The technique is fast, fully automatic, and has the potential to provide significant time savings for prostate VOI definition. AS Nelson and J Piper are partial owners of MIM Software, Inc. AS Nelson, J Piper, K Curry, and A Swallen are current employees at MIM Software, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-J-81: Evaluation of Automated Deformable Registration Between Planning Computed Tomography (CT) and Daily Cone Beam CT Images Over the Course of Prostate Cancer Radiotherapy

Purpose: To compute daily dose delivered during radiotherapy, deformable registration needs to be relatively fast, automated, and accurate. The aim of this study was to evaluate the performance of commercial deformable registration software for deforming between two modalities: planning computed tomography (pCT) images acquired for treatment planning and cone beam (CB) CT images acquired prior to each fraction of prostate cancer radiotherapy. Methods: A workflow was designed using MIM Software™ that aligned and deformed pCT into daily CBCT images in two steps: (1) rigid shifts applied after daily CBCT imaging to align patient anatomy to the pCT and (2) normalized intensity-based deformable registration to account for interfractional anatomical variations. The physician-approved CTV and organ and risk (OAR) contours were deformed from the pCT to daily CBCT over the course of treatment. The same structures were delineated on each daily CBCT by a radiation oncologist. Dice similarity coefficient (DSC) mean and standard deviations were calculated to quantify the deformable registration quality for prostate, bladder, rectum and femoral heads. Results: To date, contour comparisons have been analyzed for 31 daily fractions of 2 of 10 of the cohort. Interim analysis shows that right and left femoral head contours demonstrate the highest agreement (DSC: 0.96±0.02) with physician contours. Additionally, deformed bladder (DSC: 0.81±0.09) and prostate (DSC: 0.80±0.07) have good agreement with physician-defined daily contours. Rectum contours have the highest variations (DSC: 0.66±0.10) between the deformed and physician-defined contours on daily CBCT imaging. Conclusion: For structures with relatively high contrast boundaries on CBCT, the MIM automated deformable registration provided accurate representations of the daily contours during treatment delivery. These findings will permit subsequent investigations to automate daily dose computation from CBCT. However, improved methods need to be investigated to improve deformable results for rectum contours.

60 APPLIED LIFE SCIENCES↗

Applications of high pressure differential scanning calorimetry to aviation fuel thermal stability research

High pressure differential scanning calorimetry (DSC) was studied as an alternate method for performing high temperature fuel thermal stability research. The DSC was used to measure the heat of reaction versus temperature of a fuel sample heated at a programmed rate in an oxygen pressurized cell. Pure hydrocarbons and model fuels were studied using typical DSC operating conditions of 600 psig of oxygen and a temperature range from ambient to 500 C. The DSC oxidation onset temperature was determined and was used to rate the fuels on thermal stability. Kinetic rate constants were determined for the global initial oxidation reaction. Fuel deposit formation is measured, and the high temperature volatility of some tetralin deposits is studied by thermogravimetric analysis. Gas chromatography and mass spectrometry are used to study the chemical composition of some DSC stressed fuels.

Neveu, M. C.↗

The Application of Differential Scanning Calorimetry to Investigate Precipitation Behavior in Nickel-Base Superalloys Under Continuous Cooling and Heating Conditions

In this study, a suite of experimental tools and fast-acting, numerical-simulation techniques was used to quantify the precipitation behavior of three nickel-base superalloys: IN-100, LSHR, and 718. Experimental methods comprised differential scanning calorimetry (DSC) to establish the specific heat as a function of temperature and selected direct-resistance heating trials (using a Gleeble ® machine) to obtain samples for microstructural analysis. For the DSC experiments, each alloy was cooled at a prescribed constant rate (between 5 and 20 K/min) after an initial soak/equilibration in the high-temperature, single-phase (supersolvus) temperature regime. On-heating DSC trials beginning at ambient temperature were also performed on alloy 718 in three different starting conditions: super- δ -solvus solution treated and water quenched (denoted as ST), solution treated and aged (STA), and solution treated and overaged (STOA). DSC results, revealing the thermal signatures associated with the kinetics of precipitation of γ ' (IN-100, LSHR) or γ ' and γ " (718), were interpreted using a previously-developed fast-acting routine that treats concurrent nucleation, growth, coarsening, and dissolution. For these simulations, special attention was paid to various thermo-kinetic input parameters including equilibrium solvus-approach curves, bulk free energies of transformation, matrix-precipitate interface energies, and effective diffusivities. For the γ - γ ' superalloys (IN-100 and LSHR), estimates of precipitate volume fraction as a function of temperature from the specific-heat data revealed semi-quantitative agreement with simulation predictions. For the γ - γ '- γ " superalloy (718), simulation predictions of precipitate volume fractions were converted to specific heat as a function of temperature and showed semi-quantitative agreement with the direct measurements.

36 MATERIALS SCIENCE↗

Intra- and inter-observer variability in breast tumour bed contouring and the controversial role of surgical clips

The purpose of this study was to evaluate whether the visualization of surgical clips (SCs) on the same set of planning computed tomography (CT) of breast cancer (BC) patients influences agreement on tumour bed (TB) delineation. Planning CT (CT{sub orig}) of 47 BC patients with SCs to visualize the TB was processed in order to blur SCs and create a virtual CT (CT{sub mod}). Four radiation oncologists (ROs, 2 juniors and 2 seniors) contoured TB on both the CT sets. Centre of mass distance (CMD), percentage overlap as Dice similarity coefficient (DSC), surface distance as average Hausdorff distance (AHD) and TB volume size were analysed. The intra-observer variability when contouring TB with and without SCs was statistically significant (p-values = 0.016, 0.0002 and ≪ 0.001 for CMD, AHD and DSC, respectively). Junior ROs showed worse reproducibility compared to seniors. The median DSC was < 0.7. The inter-observer variability with and without SCs was statistically significant (p < 0.001) for all metrics, with an increase of 48.7% in DSC and decrease of 50.7% and 57.1% in CMD and AHD, respectively, as relative median values, when SCs were visible. Regarding TB volumes, when SCs were visible, the intra-observer analysis revealed that 3/4 ROs delineated larger volumes, especially juniors. The inter-observer analysis showed that, in presence of visible SCs, the difference in TB volume among all the ROs fell from statistically significant to borderline significance (p = 0.052). TB contouring is confirmed to be an observer-dependent task. SCs decreased the intra and inter-observer variability but the overall agreement between ROs remained low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evidence of a transition to reorientational disorder in the cubic alkali-metal dodecahydro-closo-dodecaborates

A neutron powder diffraction and differential scanning calorimetry (DSC) study indicates that Cs{sub 2}B{sub 12}H{sub 12} undergoes a second-order phase transition near 529 K that can be described as a reorientational disordering of the B{sub 12}H{sub 12}{sup 2-} icosahedral anions between two lowest-energy configurations within the cubic structure. Such a disordering requires the addition of another mirror plane to the low-temperature Fm3-bar structural symmetry to become Fm3-bar m. Differential scanning calorimetry measurements suggest the possible persistence of some short-range anion order at and above the transition. Additional DSC measurements of the lighter alkali-metal cubic isomorphs, Rb{sub 2}B{sub 12}H{sub 12} and K{sub 2}B{sub 12}H{sub 12}, also indicate second-order transitions for these compounds near 742 K and 811 K, respectively. These results are suggestive of similar order-disorder phase changes as for Cs{sub 2}B{sub 12}H{sub 12}, although confirmation of their existence requires analogous diffraction measurements. - Graphical Abstract: Cs{sub 2}B{sub 12}H{sub 12} undergoes an order-disorder phase transition near 529 K. Similar transitions are observed for K{sub 2}B{sub 12}H{sub 12} and Rb{sub 2}B{sub 12}H{sub 12}. Highlights: > Diffraction and DSC reveal that Cs{sub 2}B{sub 12}H{sub 12} undergoes a 2nd-order phase transition near 529 K. > This phase transition is from the low-temperature Fm3-bar symmetry to Fm3-bar m at high temperatures. > DSC of Rb{sub 2}B{sub 12}H{sub 12} and K{sub 2}B{sub 12}H{sub 12} indicate 2nd-order transitions near 742 K and 811 K, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Milling induces disorder in crystalline griseofulvin and order in its amorphous counterpart

This study investigates two apparently similar thermal signatures, shaped as bimodal exotherms, observed when either the crystalline or the amorphous from of the drug are subjected to milling. Crystalline griseofulvin was cryomilled and the (quenched-melt) amorphous form was subjected to either cryomilling or grinding. The thermal and surface properties of the resulting samples were analyzed using differential scanning calorimetry (DSC) and surface energy analysis. After milling, both the crystalline and the amorphous material revealed visually similar bimodal exothermic events when the heating rate was 20 C min{sup -1}. Under different heating rates, the pair of DSC peaks for the bimodal exotherm of each material behaved entirely different from each other. The two peaks of the bimodal event, as well as the glass transition, can be kinetically resolved for the ground amorphous form using standard mode DSC. In contrast, similar analysis was unable to resolve the bimodal exotherm or a glass transition in the case of the cryomilled crystals. Furthermore, cryomilled crystals do not exhibit a glass transition even when analyzed using modulated DSC. Synchrotron sourced X-ray analysis revealed that grinding the amorphous material results in the nucleation and growth of the crystalline form. Milling thus induces disorder in the crystals of griseofulvin but induces order in the amorphous form of the drug. The surface of the two milled systems consistently exhibited different energetics under a wide range of relative humidity conditions. These findings suggest that cryomilling induces both bulk and surface disorder, specifically, a certain level of dislocations on the crystal. In contrast, grinding the amorphous material lowers the activation energy for crystal formation, inducing nuclei formation and growth throughout the amorphous matrix.

58 GEOSCIENCES↗

Rationalizing the suitability of rhodamines as chromophores in dye-sensitized solar cells: A systematic molecular design study

Here, rhodamines are chromophores that are employed in many dye applications. Their strong optical absorption in the visible region of the electromagnetic spectrum renders them attractive dye candidates for dye-sensitized solar cells (DSCs). However, they have not yet been systematically tested in DSCs as single- or co-sensitizers. Recent advances in concerted experimental and computational workflows involving molecular design protocols can afford a better understanding of the molecular origins of the optoelectronic properties in these sensitizers. Herein, we examine the suitability of rhodamines R560 (1), R575 (2), R590 (3), R610 (4), R620 (5), R640 (6), and R3B (7) as chromophores in co-sensitized DSCs. Our study follows a stepwise approach. Initially, structural and optical properties of the dyes are investigated by experimental and computational methods to reveal structure-property relationships and other useful features for DSC applications. Subsequently, 1-7 are investigated at the dye···TiO 2 interface, both by calculations of dye-adsorption onto the surface of a modeled (TiO 2 ) 9 cluster, and by experimental studies of dye-adsorption on TiO 2 . For that purpose, a selection of rhodamine dyes are paired together (1 and 5) and (1 and 7) for co-sensitization, among which 5 is also co-adsorbed with a fluorescein dye in order to explore chemical compatibility factors. The best dye candidates are identified from the findings of these adsorption studies in terms of dye aggregation, anchoring modes, and panchromatic response. Despite their promising dye…TiO 2 adsorption and optical prospects, our results show that rhodamines lack a suitable intramolecular charge transfer pathway for dye-to-TiO 2 electron injection to occur, thus precluding their photovoltaic function as DSC dyes. Our results are then assessed against ostensibly disparate reports of rhodamines performing successfully in DSC devices; this comparison necessitated the internal reproduction of previously reported co-sensitization experiments on 2 with the industrial standard reference dye, N3. We achieve reconciliation between our results and those in the literature by reasoning that while rhodamines cannot deliver photovoltaic function in DSCs in their own right, they can either act to facilitate or deplete the photovoltaic output of a DSC indirectly by affecting the TiO 2 adsorption prospects of a photovoltaic-active dye with which a rhodamine is co-sensitized.

14 SOLAR ENERGY↗

Probing Martensitic Transition in Nitinol Wire: A Comparison of X-ray Diffraction and Other Techniques

Martensitic to austenite transformation in Nitinol wire can be measured by a number of techniques such as XRD (X-Ray Diffraction), DSC (Differential Scanning Calorimetry), BFR (Bend and Free Recovery) and Vickers indentation recovery. A comparison of results from these varied characterisation techniques is reported here to obtain a greater understanding of the thermal-elastic-structural changes associated with martensitic transformation. The transformation temperatures measured by DSC were found to correspond well with the structural and mechanical information obtained from XRD, BFR and Vickers indent recovery methods. Indent recovery is a relatively new and accurate method of monitoring stress induced martensitic transformations in NiTi and is one of only a few methods of stress inducing martensitic transformation in large scale samples. It is especially useful for NiTi in the as-cast billet form, where tensile testing is impossible. BFR is uniquely popular in the NiTi wire manufacturing sector and is recognised as the most accurate method of measuring the transformation temperature. Here the material is stressed to a representative in-service stress level during the test. No other test uses the shape memory effect for measuring the transformation temperature of NiTi. The results show that the DSC thermogram and XRD diffractogram have a peak overlap which is a common occurrence in NiTi that has been extensively processed. The XRD method further explains the observations in the DSC thermogram and in combination they confirm the transformation temperature.

36 MATERIALS SCIENCE↗