Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Multiphase Validation of Atlas-Based Automatic and Semiautomatic Segmentation Strategies for Prostate MRI

Purpose: To perform a rigorous technological assessment and statistical validation of a software technology for anatomic delineations of the prostate on MRI datasets. Methods and Materials: A 3-phase validation strategy was used. Phase I consisted of anatomic atlas building using 100 prostate cancer MRI data sets to provide training data sets for the segmentation algorithms. In phase II, 2 experts contoured 15 new MRI prostate cancer cases using 3 approaches (manual, N points, and region of interest). In phase III, 5 new physicians with variable MRI prostate contouring experience segmented the same 15 phase II datasets using 3 approaches: manual, N points with no editing, and full autosegmentation with user editing allowed. Statistical analyses for time and accuracy (using Dice similarity coefficient) endpoints used traditional descriptive statistics, analysis of variance, analysis of covariance, and pooled Student t test. Results: In phase I, average (SD) total and per slice contouring time for the 2 physicians was 228 (75), 17 (3.5), 209 (65), and 15 seconds (3.9), respectively. In phase II, statistically significant differences in physician contouring time were observed based on physician, type of contouring, and case sequence. The N points strategy resulted in superior segmentation accuracy when initial autosegmented contours were compared with final contours. In phase III, statistically significant differences in contouring time were observed based on physician, type of contouring, and case sequence again. The average relative timesaving for N points and autosegmentation were 49% and 27%, respectively, compared with manual contouring. The N points and autosegmentation strategies resulted in average Dice values of 0.89 and 0.88, respectively. Pre- and postedited autosegmented contours demonstrated a higher average Dice similarity coefficient of 0.94. Conclusion: The software provided robust contours with minimal editing required. Observed time savings were seen for all physicians irrespective of experience level and baseline manual contouring speed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp more effective than educational sessions at their own institutions. All of the residents (100%) would recommend this course to others. Conclusions: The ARC boot camp is an effective intervention for improving radiation oncology residents' knowledge and understanding of anatomy and radiology in addition to enhancing their confidence and accuracy in contouring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frustrated electron hopping from the orbital configuration in a two-dimensional lattice

Electron hopping on spatially periodic lattices gives rise to intriguing electronic behaviour. For example, hopping on the geometrically frustrated two-dimensional kagome, dice and Lieb lattices yields electronic band structures with both massless Dirac-like and perfectly dispersion-less, flat bands. As materials featuring the dice and Lieb lattice structures are scarce, an alternative approach proposes to leverage atomic orbitals to realize the characteristic electron hopping of geometrically frustrated lattices. This strategy promises to expand the list of candidate materials with frustrated electron hopping, but is yet to be shown in experiments. Here, in this study, we demonstrate frustrated hopping in the van der Waals intermetallic Pd 5 AlI 2 , emerging from the arrangement of atomic orbitals in a primitive square lattice. Using angle-resolved photoemission spectroscopy and quantum oscillation measurements, we reveal that the band structure of Pd 5 AlI 2 includes linear Dirac-like bands intersected at their crossing point by a locally flat band—an essential characteristic of frustrated hopping in Lieb and dice lattices. Moreover, this compound shows exceptional chemical stability, with its unusual bulk band structure and metallicity persisting in ambient conditions down to the monolayer limit. Hence, our results showcase a way to realize electronic structures characteristic of geometrically frustrated lattices in non-frustrated systems.

36 MATERIALS SCIENCE↗

The NEON Daily Isotopic Composition of Environmental Exchanges Dataset

The National Ecological Observatory Network (NEON) provides open-access measurements of stable isotope ratios in atmospheric water vapor (δ 2 H, δ 18 O) and carbon dioxide (δ 13 C) at different tower heights, as well as aggregated biweekly precipitation samples (δ 2 H, δ 18 O) across the United States. These measurements were used to create the NEON Daily Isotopic Composition of Environmental Exchanges (NEON-DICEE) dataset estimating precipitation (P; δ 2 H, δ 18 O), evapotranspiration (ET; δ 2 H, δ 18 O), and net ecosystem exchange (NEE; δ 13 C) isotope ratios. Statistically downscaled precipitation datasets were generated to be consistent with the estimated covariance between isotope ratios and precipitation amounts at daily time scales. Isotope ratios in ET and NEE fluxes were estimated using a mixing-model approach with calibrated NEON tower measurements. NEON-DICEE is publicly available on HydroShare and can be reproduced or modified to fit user specific applications or include additional NEON data records as they become available. The NEON-DICEE dataset can facilitate understanding of terrestrial ecosystem processes through their incorporation into environmental investigations that require daily δ 2 H, δ 18 O, and δ 13 C flux data.

54 ENVIRONMENTAL SCIENCES↗

Novel fabrication technique for high-resolution spherical crystal analyzers using a microporous aluminium base

Modern inelastic X-ray spectrometers employ curved, bent and diced analyzers to capture sufficiently large solid angles of radially emitted scattered radiation emanating from the sample. Fabricating these intricate analyzers, especially when a high energy resolution of a few millielectronvolts is required, is very time-consuming, expensive and often a hit-or-miss affair. A novel fabrication technique is introduced, utilizing a concave-spherical, microporous aluminium base to hold an assembly of a thin glass substrate with a diced crystal wafer bonded to it. Under uniform vacuum forces, the glass substrate is drawn into the aluminium base, achieving the desired bending radius, while dicing of the diffracting crystal layer prevents bending strain from being imposed on the individual crystal pixels. This technique eliminates the need for permanently bonding the crystal assembly to the concave lens, offering the opportunity for correcting figure errors, avoiding long-term degradation of the permanent bond, and making both lens and crystal reusable. Process and material costs are thus substantially decreased. Two analyzers, Si(844) and Ge(337) with intrinsic resolutions of 14.6 meV and 36.5 meV, respectively, were produced in this fashion and characterized in resonant inelastic X-ray scattering (RIXS) measurements. The achieved overall energy resolutions for both analyzers were 29.4 meV for Si(844) and 56.6 meV for Ge(337). Although the RIXS technique is veru sensitive to analyzer imperfections, the analyzers were found to be equal, if not superior, in quality to their traditional, permanently bonded counterparts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiatlas whole heart segmentation of CT data using conditional entropy for atlas ranking and selection

Purpose: Cardiac computed tomography (CT) is widely used in clinical diagnosis of cardiovascular diseases. Whole heart segmentation (WHS) plays a vital role in developing new clinical applications of cardiac CT. However, the shape and appearance of the heart can vary greatly across different scans, making the automatic segmentation particularly challenging. The objective of this work is to develop and evaluate a multiatlas segmentation (MAS) scheme using a new atlas ranking and selection algorithm for automatic WHS of CT data. Research on different MAS strategies and their influence on WHS performance are limited. This work provides a detailed comparison study evaluating the impacts of label fusion, atlas ranking, and sizes of the atlas database on the segmentation performance. Methods: Atlases in a database were registered to the target image using a hierarchical registration scheme specifically designed for cardiac images. A subset of the atlases were selected for label fusion, according to the authors’ proposed atlas ranking criterion which evaluated the performance of each atlas by computing the conditional entropy of the target image given the propagated atlas labeling. Joint label fusion was used to combine multiple label estimates to obtain the final segmentation. The authors used 30 clinical cardiac CT angiography (CTA) images to evaluate the proposed MAS scheme and to investigate different segmentation strategies. Results: The mean WHS Dice score of the proposed MAS method was 0.918 ± 0.021, and the mean runtime for one case was 13.2 min on a workstation. This MAS scheme using joint label fusion generated significantly better Dice scores than the other label fusion strategies, including majority voting (0.901 ± 0.276, p < 0.01), locally weighted voting (0.905 ± 0.0247, p < 0.01), and probabilistic patch-based fusion (0.909 ± 0.0249, p < 0.01). In the atlas ranking study, the proposed criterion based on conditional entropy yielded a performance curve with higher WHS Dice scores compared to the conventional schemes (p < 0.03). In the atlas database study, the authors showed that the MAS using larger atlas databases generated better performance curves than the MAS using smaller ones, indicating larger atlas databases could produce more accurate segmentation. Conclusions: The authors have developed a new MAS framework for automatic WHS of CTA and investigated alternative implementations of MAS. With the proposed atlas ranking algorithm and joint label fusion, the MAS scheme is able to generate accurate segmentation within practically acceptable computation time. This method can be useful for the development of new clinical applications of cardiac CT.

60 APPLIED LIFE SCIENCES↗

SU-E-J-133: Autosegmentation of Linac CBCT: Improved Accuracy Via Penalized Likelihood Reconstruction

Purpose: To improve the quality of kV X-ray cone beam CT (CBCT) for use in radiotherapy delivery assessment and re-planning by using penalized likelihood (PL) iterative reconstruction and auto-segmentation accuracy of the resulting CBCTs as an image quality metric. Methods: Present filtered backprojection (FBP) CBCT reconstructions can be improved upon by PL reconstruction with image formation models and appropriate regularization constraints. We use two constraints: 1) image smoothing via an edge preserving filter, and 2) a constraint minimizing the differences between the reconstruction and a registered prior image. Reconstructions of prostate therapy CBCTs were computed with constraint 1 alone and with both constraints. The prior images were planning CTs(pCT) deformable-registered to the FBP reconstructions. Anatomy segmentations were done using atlas-based auto-segmentation (Elekta ADMIRE). Results: We observed small but consistent improvements in the Dice similarity coefficients of PL reconstructions over the FBP results, and additional small improvements with the added prior image constraint. For a CBCT with anatomy very similar in appearance to the pCT, we observed these changes in the Dice metric: +2.9% (prostate), +8.6% (rectum), −1.9% (bladder). For a second CBCT with a very different rectum configuration, we observed +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). For a third case with significant lateral truncation of the field of view, we observed: +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). Adding the prior image constraint raised Dice measures by about 1%. Conclusion: Efficient and practical adaptive radiotherapy requires accurate deformable registration and accurate anatomy delineation. We show here small and consistent patterns of improved contour accuracy using PL iterative reconstruction compared with FBP reconstruction. However, the modest extent of these results and the pattern of differences across CBCT cases suggest that significant further development will be required to make CBCT useful to adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images

Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were used in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-113: Multi-Atlas Based Automatic Organ Segmentation for Lung Radiotherapy Planning

Purpose: Normal organ segmentation is one time-consuming and labor-intensive step for lung radiotherapy treatment planning. The aim of this study is to evaluate the performance of a multi-atlas based segmentation approach for automatic organs at risk (OAR) delineation. Methods: Fifteen Lung stereotactic body radiation therapy patients were randomly selected. Planning CT images and OAR contours of the heart - HT, aorta - AO, vena cava - VC, pulmonary trunk - PT, and esophagus – ES were exported and used as reference and atlas sets. For automatic organ delineation for a given target CT, 1) all atlas sets were deformably warped to the target CT, 2) the deformed sets were accumulated and normalized to produce organ probability density (OPD) maps, and 3) the OPD maps were converted to contours via image thresholding. Optimal threshold for each organ was empirically determined by comparing the auto-segmented contours against their respective reference contours. The delineated results were evaluated by measuring contour similarity metrics: DICE, mean distance (MD), and true detection rate (TD), where DICE=(intersection volume/sum of two volumes) and TD = {1.0 - (false positive + false negative)/2.0}. Diffeomorphic Demons algorithm was employed for CT-CT deformable image registrations. Results: Optimal thresholds were determined to be 0.53 for HT, 0.38 for AO, 0.28 for PT, 0.43 for VC, and 0.31 for ES. The mean similarity metrics (DICE[%], MD[mm], TD[%]) were (88, 3.2, 89) for HT, (79, 3.2, 82) for AO, (75, 2.7, 77) for PT, (68, 3.4, 73) for VC, and (51,2.7, 60) for ES. Conclusion: The investigated multi-atlas based approach produced reliable segmentations for the organs with large and relatively clear boundaries (HT and AO). However, the detection of small and narrow organs with diffused boundaries (ES) were challenging. Sophisticated atlas selection and multi-atlas fusion algorithms may further improve the quality of segmentations.

60 APPLIED LIFE SCIENCES↗

A digitally implemented communications experiment utilizing the communications technology satellite, Hermes

Developments which will reduce the costs associated with the distribution of satellite services are considered with emphasis on digital communication link implementation. A digitally implemented communications experiment (DICE) which demonstrates the flexibility and efficiency of digital transmission of television video and audio, telephone voice, and high-bit-rate data is described. The utilization of the DICE system in a full duplex teleconferencing mode is addressed. Demonstration teleconferencing results obtained during the conduct of two sessions of the 7th AIAA Communication Satellite Systems Conference are discussed. Finally, the results of link characterization tests conducted to determine (1) relationships between the Hermes channel 1 EIRP and DICE model performance and (2) channel spacing criteria for acceptable multichannel operation, are presented.

Jackson, H. D.↗

Chip-on-Board Technology 1996 Year-end Report (Design, Manufacturing, and Reliability Study)

The major impetus for flight qualifying Chip-On-Board (COB) packaging technology is the shift in emphasis for space missions to smaller, better, and cheaper spacecraft and satellites resulting from the NASA New Millenium initiative and similar requirements in DoD-sponsored programs. The most important benefit that can potentially be derived from miniaturizing spacecraft and satellites is the significant cost saving realizable if a smaller launch vehicle may be employed. Besides the program cost saving, there are several other advantages to building COB-based space hardware. First, once a well-controlled process is established, COB can be low cost compared to standard Multi-Chip Module (MCM) technology. This cost competitiveness is regarded as a result of the generally greater availability and lower cost of Known Good Die (KGD). Coupled with the elimination of the first level of packaging (chip package), compact, high-density circuit boards can be realized with Printed Wiring Boards (PWB) that can now be made with ever-decreasing feature size in line width and via hole. Since the COB packaging technique in this study is based mainly on populating bare dice on a suitable multi-layer laminate substrate which is not hermetically sealed, die coating for protection from the environment is required. In recent years, significant improvements have been made in die coating materials which further enhance the appeal of COB. Hysol epoxies, silicone, parylene and silicon nitride are desirable because of their compatible Thermal Coefficient of Expansion (TCE) and good moisture resistant capability. These die coating materials have all been used in the space and other industries with varying degrees of success. COB technology, specifically siliconnitride coated hardware, has been flown by Lockheed on the Polar satellite. In addition, DARPA has invested a substantial amount of resources on MCM and COB-related activities recently. With COB on the verge of becoming a dominant player in DoD programs, DARPA is increasing its support of the availability of KGDs which will help decrease their cost. Aside from the various major developments and trends in the space and defense industries that are favorable to the acceptance and widespread use of'COB packaging technology, implementing COB can be appealing in other aspects. Since the interconnection interface is usually the weak link in a system, the overall circuit or system reliability may actually be improved because of the elimination of a level of interconnect/packaging at the chip. With COB, mixing packaging technologies is possible. Because some devices are only available in commercial plastic packages, populating a multi-layer laminate substrate with both bare dice and plastic-package parts is inevitable. Another attractive feature of COB is that re-workability is possible if die coating is applied only on the die top. This method allows local replacement of individual dice that were found to be defective instead of replacing an entire board. In terms of thermal management, unpackaged devices offer a shorter thermal resistance path than their packaged counterparts thereby improving thermal sinking and heat removal from the parts.

Le, Binh Q.↗

New Methods of Sample Preparation for Atom Probe Specimens

Magnetite is a common conductive mineral found on Earth and Mars. Disk-shaped precipitates approximately 40 nm in diameter have been shown to have manganese and aluminum concentrations. Atom-probe field-ion microscopy (APFIM) is the only technique that can potentially quantify the composition of these precipitates. APFIM will be used to characterize geological and planetary materials, analyze samples of interest for geomicrobiology; and, for the metrology of nanoscale instrumentation. Prior to APFIM sample preparation was conducted by electropolishing, the method of sharp shards (MSS), or Bosch process (deep reactive ion etching) with focused ion beam (FIB) milling as a final step. However, new methods are required for difficult samples. Many materials are not easily fabricated using electropolishing, MSS, or the Bosch process, FIB milling is slow and expensive, and wet chemistry and the reactive ion etching are typically limited to Si and other semiconductors. APFIM sample preparation using the dicing saw is commonly used to section semiconductor wafers into individual devices following manufacture. The dicing saw is a time-effective method for preparing high aspect ratio posts of poorly conducting materials. Femtosecond laser micromachining is also suitable for preparation of posts. FIB time required is reduced by about a factor of 10 and multi-tip specimens can easily be fabricated using the dicing saw.

rock varnish↗

Comparative Approach of MRI-Based Brain Tumor Segmentation and Classification Using Genetic Algorithm

The detection of a brain tumor and its classification from modern imaging modalities is a primary concern, but a time-consuming and tedious work was performed by radiologists or clinical supervisors. The accuracy of detection and classification of tumor stages performed by radiologists is depended on their experience only, so the computer-aided technology is very important to aid with the diagnosis accuracy. In this study, to improve the performance of tumor detection, we investigated comparative approach of different segmentation techniques and selected the best one by comparing their segmentation score. Further, to improve the classification accuracy, the genetic algorithm is employed for the automatic classification of tumor stage. The decision of classification stage is supported by extracting relevant features and area calculation. The experimental results of proposed technique are evaluated and validated for performance and quality analysis on magnetic resonance brain images, based on segmentation score, accuracy, sensitivity, specificity, and dice similarity index coefficient. The experimental results achieved 92.03% accuracy, 91.42% specificity, 92.36% sensitivity, and an average segmentation score between 0.82 and 0.93 demonstrating the effectiveness of the proposed technique for identifying normal and abnormal tissues from brain MR images. The experimental results also obtained an average of 93.79% dice similarity index coefficient, which indicates better overlap between the automated extracted tumor regions with manually extracted tumor region by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Organ Segmentation for CT Scans Based on Super-Pixel and Convolutional Neural Networks

Accurate segmentation of specific organ from computed tomography (CT) scans is a basic and crucial task for accurate diagnosis and treatment. To avoid time-consuming manual optimization and to help physicians distinguish diseases, an automatic organ segmentation framework is presented. The framework utilized convolution neural networks (CNN) to classify pixels. To reduce the redundant inputs, the simple linear iterative clustering (SLIC) of super-pixels and the support vector machine (SVM) classifier are introduced. To establish the perfect boundary of organs in one-pixel-level, the pixels need to be classified step-by-step. First, the SLIC is used to cut an image into grids and extract respective digital signatures. Next, the signature is classified by the SVM, and the rough edges are acquired. Finally, a precise boundary is obtained by the CNN, which is based on patches around each pixel-point. The framework is applied to abdominal CT scans of livers and high-resolution computed tomography (HRCT) scans of lungs. The experimental CT scans are derived from two public datasets (Sliver 07 and a Chinese local dataset). Experimental results show that the proposed method can precisely and efficiently detect the organs. This method consumes 38 s/slice for liver segmentation. The Dice coefficient of the liver segmentation results reaches to 97.43%. For lung segmentation, the Dice coefficient is 97.93%. This finding demonstrates that the proposed framework is a favorable method for lung segmentation of HRCT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Lung Contour with Closed Principal Curve and Machine Learning

Radiation therapy plays an essential role in the treatment of cancer. In radiation therapy, the ideal radiation doses are delivered to the observed tumor while not affecting neighboring normal tissues. In three-dimensional computed tomography (3D-CT) scans, the contours of tumors and organs-at-risk (OARs) are often manually delineated by radiologists. The task is complicated and time-consuming, and the manually delineated results will be variable from different radiologists. We propose a semi-supervised contour detection algorithm, which firstly uses a few points of region of interest (ROI) as an approximate initialization. Then the data sequences are achieved by the closed polygonal line (CPL) algorithm, where the data sequences consist of the ordered projection indexes and the corresponding initial points. Finally, the smooth lung contour can be obtained, when the data sequences are trained by the backpropagation neural network model (BNNM). We use the private clinical dataset and the public Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset to measure the accuracy of the presented method, respectively. To the private dataset, experimental results on the initial points which are as low as 15% of the manually delineated points show that the Dice coefficient reaches up to 0.95 and the global error is as low as 1.47 × 10{sup −2}. The performance of the proposed algorithm is also better than the cubic spline interpolation (CSI) algorithm. While on the public LIDC-IDRI dataset, our method achieves superior segmentation performance with average Dice of 0.83.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing Interfraction Variations and Their Dosimetric Effects in Prostate Cancer Radiotherapy

Purpose: To quantitatively characterize the interfraction variations and their dosimetric effects in radiotherapy for prostate cancer. Methods and Materials: A total of 486 daily computed tomography (CT) sets acquired for 20 prostate cancer patients treated with daily CT-guided repositioning using a linear accelerator and CT-on-rail combination were analyzed. The prostate, rectum, and bladder, delineated on each daily CT data set, were compared with those from the planning CT scan. Several quantities, including Dice's coefficient and the maximal overlapping rate, were used to characterize the interfraction variations. The delivered dose was reconstructed by applying the original plan to the daily CT scan with consideration of proper repositioning. Results: The mean prostate Dice's coefficient and maximal overlapping rate after bony registration was 69.7% {+-} 13.8% (standard deviation) and 85.6% {+-} 7.8% (standard deviation), respectively. The daily delivered dose distributions were generally inferior to the planned dose distribution for target coverage and/or normal structure sparing. For example, for approximately 5% of the treatment fractions, the prostate volume receiving 100% of the prescription dose decreased dramatically (15-20%) compared with its planned value. The magnitudes of the interfraction variations and their dosimetric effects indicated that, statistically, current standard repositioning using prostate alignment might be adequate for two-thirds of the fractions, but for the rest of the fractions, better on-line correction strategies, such as on-line replanning, are needed. Conclusion: Different adaptive correction schemes for prostatic interfraction changes can be used according to the anatomic changes, as quantified by the organ displacement and deformation parameters. On-line replanning is needed for approximately one-third of the treatment fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Internal Target Volume From a Single Positron Emission Tomography/Computed Tomography Scan in Lung Cancer

Purpose: The use of four-dimensional computed tomography (4D-CT) to determine the tumor internal target volume (ITV) is usually characterized by high patient radiation exposure. The objective of this study was to propose and evaluate an approach that relies on a single static positron emission tomography (PET)/CT scan to determine the ITV, thereby eliminating the need for 4D-CT and thus reduce patient radiation dose. Methods and Materials: The proposed approach is based on the concept that the observed PET image is the result of a joint convolution of an ideal PET image (free from motion and partial volume effect) with a motion-blurring kernel (MBK) and partial volume effect. In this regard, the MBK and tumor ITV are then estimated from the deconvolution of this joint model. To test this technique, phantom and patient studies were performed using different sphere/tumor sizes and motion trajectories. In all studies, a 4D-CT and a PET/CT image of the sphere/tumor were acquired. The ITV from the proposed technique was then compared to the maximum intensity projection (MIP) volume of the 4D-CT images. A Dice coefficient of the two volumes was calculated to represent the similarity between the two ITVs. Results: The average ITVs of the proposed technique were 97.2% {+-} 0.3% and 81.0% {+-} 16.7% similar to the MIP volume in the phantom and patient studies, respectively. The average dice coefficients were 0.87 {+-} 0.05 and 0.73 {+-} 0.16, respectively, for the two studies. Conclusion: Using the proposed approach, a single static PET/CT scan has the potential to replace a 4D-CT to determine the tumor ITV. This approach has the added advantage of reducing patient radiation exposure and determining the tumor MBK compared to 4D-CT/MIP-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗