Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAPHRAGM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring

Flexible pressure sensors have many potential applications in wearable electronics, robotics, health monitoring, and more. In particular, liquid-metal-based sensors are especially promising as they can undergo strains of over 200% without failure. However, current liquid-metal-based strain sensors are incapable of resolving small pressure changes in the few kPa range, making them unsuitable for applications such as heart-rate monitoring, which require a much lower pressure detection resolution. In this paper, a microfluidic tactile diaphragm pressure sensor based on embedded Galinstan microchannels (70 µm width × 70 µm height) capable of resolving sub-50 Pa changes in pressure with sub-100 Pa detection limits and a response time of 90 ms is demonstrated. An embedded equivalent Wheatstone bridge circuit makes the most of tangential and radial strain fields, leading to high sensitivities of a 0.0835 kPa -1 change in output voltage. The Wheatstone bridge also provides temperature self-compensation, allowing for operation in the range of 20–50 °C. Finally, as examples of potential applications, a polydimethylsiloxane (PDMS) wristband with an embedded microfluidic diaphragm pressure sensor capable of real-time pulse monitoring and a PDMS glove with multiple embedded sensors to provide comprehensive tactile feedback of a human hand when touching or holding objects are demonstrated.

47 OTHER INSTRUMENTATION↗

Acoustooptical visualisation of biological media using multislit diaphragms

The influence of special multislit diaphragms placed in front of the receiver cathode on the signal value and signal-to-noise ratio in acoustooptical visualisation of scattering biological media is studied. Using such diaphragms the visualisation of a bulk lightabsorbing and sound-transmitting object in the form of a rectangular parallelepiped with the size 5 Multiplication-Sign 5 mm in the plane, perpendicular to the laser beam axis, and with the size 2.5 parallel to this axis is carried out. The object was merged into scattering media of thickness L{sub c} = 62 mm along the direction of propagation of the optical radiation with the parameter {mu}L{sub c} varying from 0 to 46.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cerium oxide nanoparticle treatment ameliorates peritonitis-induced diaphragm dysfunction

The severe inflammation observed during sepsis is thought to cause diaphragm dysfunction, which is associated with poor patient prognosis. Cerium oxide (CeO 2 ) nanoparticles have been posited to exhibit anti-inflammatory and antioxidative activities suggesting that these particles may be of potential use for the treatment of inflammatory disorders. To investigate this possibility, Sprague Dawley rats were randomly assigned to the following groups: sham control, CeO 2 nanoparticle treatment only (0.5 mg/kg iv), sepsis, and sepsis+CeO2 nanoparticles. Sepsis was induced by the introduction of cecal material (600 mg/kg) directly into the peritoneal cavity. Nanoparticle treatment decreased sepsis-associated impairments in diaphragmatic contractile (P o ) function (sham: 25.6 ± 1.6 N/ cm 2 vs CeO 2 : 23.4 ± 0.8 N/ cm 2 , vs Sep: 15.9 ± 1.0 N/ cm 2 vs Sep+CeO 2 : 20.0 ± 1.0 N/ cm 2 , P<0.05). These improvements in diaphragm contractile function were accompanied by a normalization of protein translation signaling (Akt, FOXO-1, and 4EBP1), diminished proteolysis (caspase 8 and ubiquitin levels), and decreased inflammatory signaling (Stat3 and iNOS). Histological analysis suggested that nanoparticle treatment was associated with diminished sarcolemma damage and diminished inflammatory cell infiltration. These data indicate CeO 2 nanoparticles may improve diaphragmatic function in the septic laboratory rat.

59 BASIC BIOLOGICAL SCIENCES↗

Networks that link cytoskeletal regulators and diaphragm proteins underpin filtration function in Drosophila nephrocytes

Highlights: • Drosophila nephrocytes have a unique cytoplasmic cluster of F-actin. • Microtubules, Rho-GTPases and endoplasmic reticulum position the actin cluster. • Nephrocyte diaphragm proteins localize to and regulate actin cluster organization. • Perturbation of any of these inter-dependent components impairs ultrafiltration. Insect nephrocytes provide a valuable model for kidney disease, as they are structurally and functionally homologous to mammalian kidney podocytes. They possess an exceptional macromolecular assembly, the nephrocyte diaphragm (ND), which serves as a filtration barrier and helps maintain tissue homeostasis by filtering out wastes and toxic products. However, the elements that maintain nephrocyte architecture and the ND are not understood. We show that Drosophila nephrocytes have a unique cytoplasmic cluster of F-actin, which is maintained by the microtubule cytoskeleton and Rho-GTPases. A balance of Rac1 and Cdc42 activity as well as proper microtubule organization and endoplasmic reticulum structure, are required to position the actin cluster. Further, ND proteins Sns and Duf also localize to this cluster and regulate organization of the actin and microtubule cytoskeleton. Perturbation of any of these inter-dependent components impairs nephrocyte ultrafiltration. Thus cytoskeletal components, Rho-GTPases and ND proteins work in concert to maintain the specialized nephrocyte architecture and function.

60 APPLIED LIFE SCIENCES↗

Structural insights into plasmalemma vesicle-associated protein (PLVAP): Implications for vascular endothelial diaphragms and fenestrae

In many organs, small openings across capillary endothelial cells (ECs) allow the diffusion of low–molecular weight compounds and small proteins between the blood and tissue spaces. These openings contain a diaphragm composed of radially arranged fibers, and current evidence suggests that a single-span type II transmembrane protein, plasmalemma vesicle-associated protein-1 (PLVAP), constitutes these fibers. Here, we present the three-dimensional crystal structure of an 89-amino acid segment of the PLVAP extracellular domain (ECD) and show that it adopts a parallel dimeric alpha-helical coiled-coil configuration with five interchain disulfide bonds. The structure was solved using single-wavelength anomalous diffraction from sulfur-containing residues (sulfur SAD) to generate phase information. Biochemical and circular dichroism (CD) experiments show that a second PLVAP ECD segment also has a parallel dimeric alpha-helical configuration—presumably a coiled coil—held together with interchain disulfide bonds. Overall, ~2/3 of the ~390 amino acids within the PLVAP ECD adopt a helical configuration, as determined by CD. We also determined the sequence and epitope of MECA-32, an anti-PLVAP antibody. Taken together, these data lend strong support to the model of capillary diaphragms formulated by Tse and Stan in which approximately ten PLVAP dimers are arranged within each 60- to 80-nm-diameter opening like the spokes of a bicycle wheel. Passage of molecules through the wedge-shaped pores is presumably determined both by the length of PLVAP—i.e., the long dimension of the pore—and by the chemical properties of amino acid side chains and N-linked glycans on the solvent-accessible faces of PLVAP.

59 BASIC BIOLOGICAL SCIENCES↗

Design Considerations of a Slit Diaphragm Flexure Used in a Precision Mirror Gimbal

Two precision mirror gimbals were designed using slit diaphragm flexures to provide two-axis precision mirror alignment in space-limited applications. Both gimbals are currently in use in diagnostics at the National Ignition Facility: one design in the Gamma Reaction History (GRH) diagnostic and the other in the Neutron Imaging System (NIS) diagnostic. The GRH gimbal has an adjustment sensitivity of 0.1 mrad about both axes and a total adjustment capability of ±6°; the NIS gimbal has an adjustment sensitivity of 0.8 μrad about both axes and a total adjustment range of ±3°. Both slit diaphragm flexures were electro-discharge machined out of high-strength titanium and utilize stainless steel stiffeners. The stiffener-flexure design results in adjustment axes with excellent orthogonality and centering with respect to the mirror in a single stage; a typical two-axis gimbal flexure requires two stages. Finite element analyses are presented for both flexure designs, and a design optimization of the GRH flexure is discussed.

42 ENGINEERING↗

Improved fluid control valve extends diaphragm life

Wear resistance of flexible diaphragms in fluid control valves is increased by incorporating a soft rubber washer at the bottom of the piston, a flexible buffer between the diaphragm and the valve seat, and a fluid feedback arrangement. The stress and wear of components at the valve seat are minimized.

Mac Glashan, W. F.↗

Diaphragm eliminates leakage in cryogenic fluid duct coupling

Duct coupling with nickel steel diaphragm of low thermal expansivity is leakproof when used with cryogenic fluids. The diaphragm, located between the two flanges of the coupling, reduces axial shrinkage at the coupling flanges to a minimum.

Source record↗

Vibrating diaphragm measures high electrostatic field strengths

Meter with flexible conductive diaphragm measures electrostatic charge density on a conducting surface in a vacuum. The diaphragm is supported from an insulated conductive support ring rigidly attached to the conductive surface whose electrostatic charge density is to be measured.

Source record↗

Electrically heated diaphragm eliminates use of pyrotechnics

Membrane-type diaphragm is used in systems where fluids are contained under pressure until a certain pressure threshold or point of time has been reached when the fluids are automatically released. The diaphragm is resistance heated until its strength is degraded to the point of rupture, thus releasing the contained fluids.

Mathewson, R. C.↗

Embossed metal diaphragm has two-way stretch

Diaphragm with embossed pattern has greater structural rigidity than one with smooth surfaces, but under severe stress, tensile loads will flatten embossing. This provides necessary additional panel stretch needed to prevent rupture of diaphragm material. Hexagonal embossing-configuration allows panel stretch in any direction or in all directions simultaneously.

Macglashan, W. F., Jr.↗

Slosh testing of a spherical mercury propellant tank with positive-expulsion diaphragm

A preliminary investigation was conducted to evaluate the lateral slosh characteristics of a 23-cm diameter mercury propellant tank with a positive-expulsion diaphragm and 17.5% ullage. Data are presented for tank sinusoidal acceleration levels between 0.05 and 0.5 g at frequencies ranging from 5 to 50 Hz. Results indicate that slosh characteristics are highly nonlinear at acceleration levels approaching those in flight, and depend heavily on the shape and stiffness of the diaphragm. Nyquist plots of driving force over acceleration are shown to be a useful tool for determining natural frequency, damping, and modal mass characteristics. A computerized nonlinear least squares method for extracting the modal parameters from the Nyquist plots is described and results of applying the method are presented.

Ross, R. G., Jr.↗

Miniature diaphragm valve for medical equipment

Valve assembly keeps nutrient out of moving parts of valve by physically isolating plunger from fluid. Poppet and diaphragm are molded together, and latter is shaped to act as static seal, which remains seated during the operation. As plunger moves, diaphragm also moves to form separate cavity for nutrient and thus isolates it from plunger cavity and latching mechanism.

Stadler, T. J.↗

Flexible Diaphragm Withstands Extreme Temperatures

Diaphragm seal retains flexibility throughout temperature range of -200 to +600 degree F (-129 to +316 degree C). Diaphragm durable, simple, versatile, and relatively inexpensive to manufacture. Suitable for refrigeration seals, autoclaves, storage lockers, and other sealing applications subjected to extreme temperature differentials.

Lerma, G.↗

Method of making a flexible diaphragm

A diaphragm suitable for extreme temperature usage, such as encountered in critical aerospace applications, is fabricated by a unique method, and of a unique combination of materials, which include multilayered lay-ups of diaphragm materials sandwiched between layers of bleeder fabrics which, after being formed in the desired shape on a mold, are vacuum sealed and then cured under pressure, in a heated autoclave, to produce a bond capable of withstanding extreme temperatures.

Lerma, Guillermo↗

A flow-transfer device with nonmetallic diaphragms for propulsion wind tunnel models

The Langley Research Center has developed a new flow-transfer device for powered wind tunnel models in which the traditional metal bellows have been replaced with nonmetallic diaphragms. Two complete flow transfer assemblies have been fabricated and installed within a twin-jet propulsion simulation system. Calibrations of the force balance have been performed over a range of nozzle mass flow rates up to 15 lbs/sec in order to validate the nonmetallic diaphragm design concept. Results from these calibrations are compared to those obtained with flow-transfer devices utilizing metal bellows.

Capone, Francis J.↗