Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAGNOSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

COVID-19 Biomarkers and Advanced Sensing Technologies for Point-of-Care (POC) Diagnosis

COVID-19, also known as SARS-CoV-2 is a novel, respiratory virus currently plaguing humanity. Genetically, at its core, it is a single-strand positive-sense RNA virus. It is a beta-type Coronavirus and is distinct in its structure and binding mechanism compared to other types of coronaviruses. Testing for the virus remains a challenge due to the small market available for at-home detection. Currently, there are three main types of tests for biomarker detection: viral, antigen and antibody. Reverse Transcription-Polymerase Chain Reaction (RT-PCR) remains the gold standard for viral testing. However, the lack of quantitative detection and turnaround time for results are drawbacks. This manuscript focuses on recent advances in COVID-19 detection that have lower limits of detection and faster response times than RT-PCR testing. The advancements in sensing platforms have amplified the detection levels and provided real-time results for SARS-CoV-2 spike protein detection with limits as low as 1 fg/mL in the Graphene Field Effect Transistor (FET) sensor. Additionally, using multiple biomarkers, detection levels can achieve a specificity and sensitivity level comparable to that of PCR testing. Proper biomarker selection coupled with nano sensing detection platforms are key in the widespread use of Point of Care (POC) diagnosis in COVID-19 detection.

60 APPLIED LIFE SCIENCES↗

Early Diagnosis of Fibromyalgia Using Surface-Enhanced Raman Spectroscopy Combined with Chemometrics

Fibromyalgia (FM) is a chronic muscle pain disorder that shares several clinical features with other related rheumatologic disorders. This study investigates the feasibility of using surface-enhanced Raman spectroscopy (SERS) with gold nanoparticles (AuNPs) as a fingerprinting approach to diagnose FM and other rheumatic diseases such as rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), osteoarthritis (OA), and chronic low back pain (CLBP). Blood samples were obtained on protein saver cards from FM (n = 83), non-FM (n = 54), and healthy (NC, n = 9) subjects. A semi-permeable membrane filtration method was used to obtain low-molecular-weight fraction (LMF) serum of the blood samples. SERS measurement conditions were standardized to enhance the LMF signal. An OPLS-DA algorithm created using the spectral region 750 to 1720 cm -1 enabled the classification of the spectra into their corresponding FM and non-FM classes (Rcv > 0.99) with 100% accuracy, sensitivity, and specificity. The OPLS-DA regression plot indicated that spectral regions associated with amino acids were responsible for discrimination patterns and can be potentially used as spectral biomarkers to differentiate FM and other rheumatic diseases. This exploratory work suggests that the AuNP SERS method in combination with OPLS-DA analysis has great potential for the label-free diagnosis of FM.

60 APPLIED LIFE SCIENCES↗

Abiotic and Biotic Damage of Microalgae Generate Different Volatile Organic Compounds (VOCs) for Early Diagnosis of Algal Cultures for Biofuel Production

Open microalgal ponds used in industrial biomass production are susceptible to a number of biotic and abiotic environmental stressors (e.g., grazers, pathogens, pH, temperature, etc.) resulting in pond crashes with high economic costs. Identification of signature chemicals to aid in rapid, non-invasive, and accurate identification of the stressors would facilitate targeted and effective treatment to save the algal crop from a catastrophic crash. Specifically, we were interested in identifying volatile organic compounds (VOCs) that can be used to as an early diagnostic for algal crop damage. Cultures of Microchloropsis gaditana were subjected to two forms of algal crop damage: (1) active grazing by the marine rotifer, Brachionus plicatilis, or (2) repeated freeze–thaw cycles. VOCs emitted above the headspace of these algal cultures were collected using fieldable solid phase microextraction (SPME) fibers. An untargeted analysis and identification of VOCs was conducted using gas chromatography-mass spectrometry (GC-MS). Diagnostic VOCs unique to each algal crop damage mechanism were identified. Active rotifer grazing of M. gaditana was characterized by the appearance of carotenoid degradation products, including β-cyclocitral and various alkenes. Freeze–thaw algae produced a different set of VOCs, including palmitoleic acid. Both rotifer grazing and freeze–thawed algae produced β-ionone as a VOC, possibly suggesting a common stress-induced cellular mechanism. Importantly, these identified VOCs were all absent from healthy algal cultures of M. gaditana. Early detection of biotic or abiotic environmental stressors will facilitate early diagnosis and application of targeted treatments to prevent algal pond crashes. Thus, our work further supports the use of VOCs for monitoring the health of algal ponds to ultimately enhance algal crop yields for production of biofuel.

09 BIOMASS FUELS↗

Non-invasive, in situ diagnosis and monitoring of corrosion in high temperature systems

Techniques for non-invasive diagnosis and/or monitoring of corrosion in high temperature systems using specialized sensors that produce multi-mode acoustic signals in situ for accurate determination of wall loss and/or physical property changes for a vessel in contact with a high temperature, highly corrosive substance are disclosed. Sensitivity of a few microns (or about 0.1%) of wall loss, detection of changes in physical properties of vessel contents (e.g., approximately 1%), or both, at temperatures of 500° C., 600° C., or higher may be realized. Corrosion may be identified and/or monitored using time domain, frequency domain, or mixed time domain and frequency domain analysis of signal characteristics, signal delay, or both, for relatively short circumferential acoustic wave propagation (e.g., a few inches), as well as relatively long axial acoustic wave propagation (e.g., tens of feet).

Findikoglu, Alp Tugrul↗

Machine-Learning for Battery Health Diagnosis

Battery health diagnosis often requires time-consuming measurements in laboratory conditions, but these types of measurements are unsuitable for use in real-world application such as electric vehicles. Instead, rapid measurements that can be conducted at varying environmental conditions need to be used to monitor battery health. Machine-learning techniques can then be utilized to connect these rapid measurements to health diagnostic information recorded in the lab. This presentation is a part of a tutorial on using machine-learning methods to analyze and predict battery state.

battery↗

Direct Bayesian inference for fault severity assessment in Digital-Twin-Based fault diagnosis

For applications in condition-based maintenance of nuclear systems, the assessment of fault severity is crucial. In this work, we developed a framework that allows for direct inference of the probability distributions of possible faults in a system. Here, we employed a model-based approach with model residuals generated from analytical redundancy relations provided by physics-based models of the system components. From real-time sensor readings, the values of the model residuals can be calculated, and the posterior probability distributions of the faults can be computed directly using the methods of Bayesian networks. From the posterior distribution of each fault, one can estimate the fault probability based on a chosen threshold and assess the severity of the fault. By eliminating the discretization and simplifications in middle steps, this approach allows us to leverage the available computational resources to provide more accurate fault probability estimates and severity assessments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamic model-based feature extraction for fault detection and diagnosis of a supermarket refrigeration system

With the increasing concerns over climate change and carbon emissions, fault detection and diagnostics (FDD) of low–global warming potential (GWP) refrigerant supermarket refrigeration systems has gained great attention from academic and industrial sectors. Various FDD approaches have been developed to detect, identify, and diagnose faults to save energy, improve food quality, and protect the environment. Here, to mitigate the difficulty of collecting high-quality steady-state operational data in field operations faced by most model-based FDD methods, this study developed dynamic models of a low–GWP refrigerant (CO 2 ) supermarket refrigeration system. The model accuracy was validated using manufacturer data and experimental data. Simulations were conducted to predict the system dynamic response under two common operational faults—evaporator air path blockage fault and the display case door open fault—to identify fault patterns and define key dynamic behavior indexes for supporting FDD algorithm development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-diagnosis of model suitability for continuous measurements of stream-dissolved organic carbon derived from in situ UV–visible spectroscopy

Application of high-frequency monitoring of dissolved organic carbon (DOC) is difficult in instances where training datasets are challenging to develop (e.g., remote locations) and the relationship between optical features and DOC concentration changes due to environmental or landscape shifts (e.g., climate or land-use change). We developed and compared three partial least squares (PLS) models using in situ water level measurements, conductivity, and UV–Vis spectral attenuation to predict DOC. Two site-specific models were developed using data from a hillslope-dominated forest or a low-relief wetland-pond-dominated stream catchment. The third model, using data from both sites, exhibited the best performance (DOC range = 4–15.5 mg C L −1 , mean = 8.38 mg C L −1 , training RMSE = 0.34 mg C L −1 , internal validation RMSE = 0.50 mg C L −1 , external validation RMSE = 2.43 mg C L −1 ). We further demonstrate using PLS model statistics to monitor performance and elucidate when and how models should be updated. These statistics, Hotelling's T 2 and squared prediction errors, are useful consistency checks for the predictions made and detect underlying inconsistencies that, if undetected, can reduce the robustness of DOC prediction. For example, via the T 2 statistic, we identified the summer–autumn transition as a period when DOC composition differed from what was represented in the training dataset. We also determined that elevated SUVA 254 values contributed to the overall bias observed in predictions made during the subsequent year as part of the external validation. This enabled the application of a bias correction that reduced the RMSE from 2.43 to 0.89 mg C L −1 . The method presented here could be applied to future monitoring programs enabling model updates to monitor DOC fluxes accurately from optical datasets (e.g., attenuance or fluorescence) in the face of developing datasets in remote locations or environmental change. In conclusion, implementation of this approach may also identify possible regime shifts or landscape and hydrologic change associated with climate and other environmental changes relevant to terrestrial to aquatic fluxes.

UV-VIS spectroscopy↗