Power density measurements Test report
Evaluation of power density test measurements on radio frequency emitter at Apollo Saturn assembly and launch complexes
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Evaluation of power density test measurements on radio frequency emitter at Apollo Saturn assembly and launch complexes
Prediction of flow-field properties in supersonic jets using computational fluid dynamics (CFD) code predictions has become routine; however, obtaining accurate solutions becomes more challenging when there is a significant temperature difference between the jet core and the ambient air and/or compressibility effects are significant. Benchmark sets of flow field property data are required in order to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of temperatures and turbulent heat flux is important. Particle Image Velocimetry (PIV), spontaneous rotational Raman scattering (SRS) spectroscopy and Background Oriented Schlieren (BOS) have been previously used to acquire measurements of the mean and root mean square (rms) velocities, the mean and rms gas temperatures and density gradients in subsonic jet flows and film cooling flows. In this work, the ability to measure density is added to the list of measurands available using the acquired Raman spectra. The suite of measurement techniques are now applied to supersonic jet flows. The computation of the local gas pressure in the potential core of an over-expanded jet is demonstrated using the Raman measured gas temperature and density. Additionally, a unique density feature in temperature matched, perfectly expanded jet flow shear layers identified using BOS was verified using the Raman measurement technique. These non-intrusive flow measurements are compared against RANS predictions of the supersonic jet flow properties as a means of assessing their prediction accuracy.
In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.
Midlatitude sunrise electron density profiles have been analyzed in order to determine nitric oxide concentrations in the range 100-160 km. In general, the determinations are restricted to heights for which the ionization of nitric oxide by direct solar Lyman-alpha radiation is the main contribution to the growth of the E region. The concentrations obtained are larger, by factors of approximately 3 to 4, than those obtained from the midlatitude airglow measurements of other workers. Concentrations have been obtained from one sunset measurement and these are significantly lower than the sunrise values. The results also give a clear indication of increasing nitric oxide concentrations above 120 km with increasing solar activity.
A method for making density measurements in a compressible flow by using off resonance laser induced fluorescence is studied. The seed molecule chosen for study is the iodine molecule which is excited with the 514.5 nm line of the argon ion laser whose output is frequency tuned, by as much as 3 GHz, relative to a strong iodine transition using an intracavity etalon. The theory which was developed to analyze the effect will be used in conjunction with two experiments being conducted to further study the method an acoustic resonance tube in which controlled perturbations about a uniform state are produced, and a small supersonic jet in which the conditions of the flow vary widely from point to point.
Lunar surface layer density measurement by Luna-13 using radiometric method of registering scattered gamma radiation
Oxygen surface densities measured by method based on characteristic X ray production by 100 kev protons
Wide argon plasma column by axial current density measurements, confirming existence of instability and determining critical magnetic field
Electromechanical densitometer continuously measures the densities of either single-phase or two-phase flowing cryogenic fluids. Measurement is made on actual flow. The instrument operates on the principle that the mass of any vibrating system is a primary factor in determining the dynamic characteristics of the system.
The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential nonuniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to 10% of the average current density in the discharge and 5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.
The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential non-uniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to +/-10% of the average current density in the discharge and +/-5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 - 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.
Measurement of plasma density generated by underwater explosions, noting modes of electrical discharge and shock front role
Open ion source mass spectrometer used with omegatron mass spectrometer to measure atmospheric gas density and composition in thermosphere probe experiment
Multichannel system employing a radioisotope radiation source, strontium-90, radiation detector, and a silicon surface barrier detector, measures the local density of liquid hydrogen at various levels in a storage tank. The instrument contains electronic equipment for collecting the density information, and a data handling system for processing this information.
The formulation of the crossed beam correlation technique is generalized to include strongly absorbing media. The first measurements of point density fluctuations at contact surfaces have been obtained. The presence of turbulent bursts is confirmed and a characteristic spectral frequency of approximately 400 Hz is estimated.
Report presents theoretical and experimental study of use of laser-induced fluorescence in oxygen to measure temperatures and densities in air flowing in hypersonic wind tunnel.
Rocket payload with gamma radiation source and scintillation detector flight tested for feasibility of gamma ray scattering as technique for air density measurement
A detailed study is described of the performance capabilities and the hardware requirements for a method in which ambient density is measured along the Space Shuttle flight path using on-board optical instrumentation. The technique relies on Rayleigh scattering of light from a pulsed, ultraviolet, ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing direct measurements of ambient density with an uncertainty of less than 1 percent and with a spatial resolution of 1 km, over an altitude range from 50 to 90 km. In addition, extensions of this concept are discussed that allow measurements of the shock wave location and the density profile within the shock layer. Two approaches are identified that appear to be feasible, in which the same laser system is used for the extended measurements as that required for the ambient density measurements.