Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DEFAULT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

MELCOR 1.8.5 modeling aspects of fission product release, transport and deposition an assessment with recommendations.

The Phebus and VERCORS data have played an important role in contemporary understanding and modeling of fission product release and transport from damaged light water reactor fuel. The data from these test programs have allowed improvement of MELCOR modeling of release and transport processes for both low enrichment uranium fuel as well as high burnup and mixed oxide (MOX) fuels. This paper discusses the synthesis of these findings in the MELCOR severe accident code. Based on recent assessments of MELCOR 1.8.5 fission product release modeling against the Phebus FPT-1 test and on observations from the ISP-46 exercise, modifications to the default MELCOR 1.8.5 release models are recommended. The assessments identified an alternative set of Booth diffusion parameters recommended by ORNL (ORNL-Booth), which produced significantly improved release predictions for cesium and other fission product groups. Some adjustments to the scaling factors in the ORNL-Booth model were made for selected fission product groups, including UO{sub 2}, Mo and Ru in order to obtain better comparisons with the FPT-1 data. The adjusted model, referred to as 'Modified ORNL-Booth,' was subsequently compared to original ORNL VI fission product release experiments and to more recently performed French VERCORS tests, and the comparisons was as favorable or better than the original CORSOR-M MELCOR default release model. These modified ORNL-Booth parameters, input to MELCOR 1.8.5 as 'sensitivity coefficients' (i.e. user input that over-rides the code defaults) are recommended for the interim period until improved release models can be implemented into MELCOR. For the case of ruthenium release in air-oxidizing conditions, some additional modifications to the Ru class vapor pressure are recommended based on estimates of the RuO{sub 2} vapor pressure over mildly hyperstoichiometric UO{sub 2}. The increased vapor pressure for this class significantly increases the net transport of Ru from the fuel to the gas stream. A formal model is needed. Deposition patterns in the Phebus FPT-1 circuit were also significantly improved by using the modified ORNL-Booth parameters, where retention of lower volatile Cs{sub 2}MoO{sub 4} is now predicted in the heated exit regions of the FPT-1 test, bringing down depositions in the FPT-1 steam generator tube to be in closer alignment with the experimental data. This improvement in 'RCS' deposition behavior preserves the overall correct release of cesium to the containment that was observed even with the default CORSOR-M model. Not correctly treated however is the release and transport of Ag to the FPT-1 containment. A model for Ag release from control rods is presently not available in MELCOR. Lack of this model is thought to be responsible for the underprediction by a factor of two of the total aerosol mass to the FPT-1 containment. It is suggested that this underprediction of airborne mass led to an underprediction of the aerosol agglomeration rate. Underprediction of the agglomeration rate leads to low predictions of the aerosol particle size in comparison to experimentally measured ones. Small particle size leads low predictions of the gravitational settling rate relative to the experimental data. This error, however, is a conservative one in that too-low settling rate would result in a larger source term to the environment. Implementation of an interim Ag release model is currently under study. In the course of this assessment, a review of MELCOR release models was performed and led to the identification of several areas for future improvements to MELCOR. These include upgrading the Booth release model to account for changes in local oxidizing/reducing conditions and including a fuel oxidation model to accommodate effects of fuel stoichiometry. Models such as implemented in the French ELSA code and described by Lewis are considered appropriate for MELCOR. A model for ruthenium release under air oxidizing conditions is also needed and should be included as part of a fuel oxidation model since fuel stoichiometry is a fundamental parameter in determining the vapor pressure of ruthenium oxides over the fuel. There is also a need to expand the MELCOR architecture for tracking fission product classes to allow for more speciation of fission products. An example is the formation of CsI and Cs{sub 2}MoO{sub 4} and potentially CsOH if all Mo is combined with Cs such that excess Cs exists in the fuel. Presently, MELCOR can track only one class combination (CsI) accurately, where excess Cs is assumed to be CsOH. Our recommended interim modifications map the CsOH (MELCOR Radionuclide Class 2) and Mo (Class 7) vapor pressure properties to Cs{sub 2}MoO{sub 4}, which approximates the desired formal class combination of Cs and Mo. Other extensions to handle properly iodine speciation from pool/gas chemistry are also needed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AWAKEN Site A1 - NREL Ceilometer (Vaisala CL51) / Derived Data

Site A1 netCDF L3 data files have level 3 (L3) data that have gone through the calculation service and contain all the data from the algorithms, including mixing layer height values and quality index data. L3 default files contain L3 data that use the default preset for a live plot. File naming schema: L3_DEFAULT_ _YYYYMMDDHHMM_ _ .nc Name Description L3 Identification of the data level DEFAULT Identification of the L3 file type CUSTOM OFFLINE STATION_NUMBER WMO station number, if defined YYYYMMDDHHMM UTC time ParameterKey Identification of the advanced algorithm settings. See the table below for an explanation. FREE_FORMAT File suffix, if defined

17 WIND ENERGY↗

WFIP3 - BARG site - NREL Ceilometer (Vaisala CL51) / Derived Data

Site A1 netCDF L3 data files have level 3 (L3) data that have gone through the calculation service and contain all the data from the algorithms, including mixing layer height values and quality index data. L3 default files contain L3 data that use the default preset for a live plot. File naming schema: L3_DEFAULT_ _YYYYMMDDHHMM_ _ .nc Name Description L3 Identification of the data level DEFAULT Identification of the L3 file type CUSTOM OFFLINE STATION_NUMBER WMO station number, if defined YYYYMMDDHHMM UTC time ParameterKey Identification of the advanced algorithm settings. See the table below for an explanation. FREE_FORMAT File suffix, if defined

17 WIND ENERGY↗

WFIP3 - BARG site - NREL Ceilometer (Vaisala CL51) / Derived Data

BARG ceilometer: netCDF L3 data files have level 3 (L3) data that have gone through the calculation service and contain all the data from the algorithms, including mixing layer height values, and quality index data. L3 default files contain L3 data that use the default preset for a live plot. File naming schema: L3_DEFAULT_ _YYYYMMDDHHMM_ _ .nc Name Description L3 Identification of the data level DEFAULT Identification of the L3 file type CUSTOM OFFLINE STATION_NUMBER WMO station number, if defined YYYYMMDDHHMM UTC time ParameterKey Identification of the advanced algorithm settings. See the table below for an explanation. FREE_FORMAT File suffix, if defined

17 WIND ENERGY↗

WFIP3 - NOAA SHIP site - NREL Ceilometer (Vaisala CL51) / Derived Data

NOAA SHIP ceilometer: netCDF L3 data files have level 3 (L3) data that have gone through the calculation service and contain all the data from the algorithms, including mixing layer height values, and quality index data. L3 default files contain L3 data that use the default preset for a live plot. File naming schema: L3_DEFAULT_ _YYYYMMDDHHMM_ _ .nc Name Description: L3 Identification of the data level DEFAULT Identification of the L3 file type CUSTOM OFFLINE STATION_NUMBER WMO station number, if defined YYYYMMDDHHMM UTC time ParameterKey Identification of the advanced algorithm settings. See the table below for an explanation. FREE_FORMAT File suffix, if defined

17 WIND ENERGY↗

WFIP3 - CACO site - NREL Ceilometer (Vaisala CL51) / Derived Data

CACO ceilometer: netCDF L3 data files have level 3 (L3) data that have gone through the calculation service and contain all the data from the algorithms, including mixing layer height values, and quality index data. L3 default files contain L3 data that use the default preset for a live plot. File naming schema: L3_DEFAULT_ _YYYYMMDDHHMM_ _ .nc Name Description: L3 Identification of the data level DEFAULT Identification of the L3 file type CUSTOM OFFLINE STATION_NUMBER WMO station number, if defined YYYYMMDDHHMM UTC time ParameterKey Identification of the advanced algorithm settings. See the table below for an explanation. FREE_FORMAT File suffix, if defined

17 WIND ENERGY↗

IM3 SELECT Urbanization Data

IM3 SELECT Urbanization Data Urban fraction is provided in TIF files projected on the WGS84 datum at coarse (1/8 degree) and downscaled (1km) resolutions across the globe for each of three Shared Socioeconomic Pathway (SSP) scenarios corresponding to SSP2, SSP3, and SSP5; and each of two population scenarios corresponding to the default population scenario and an updated population scenario with more detailed projections for the United States. The population projections are provided as CSV files. Folder structure: default_population population urban_fraction coarse SSP2 SSP3 SSP5 downscaled SSP2 SSP3 SSP5united_states_updated_population population urban_fraction coarse SSP2 SSP3 SSP5 downscaled SSP2 SSP3 SSP5 Urban fraction data was produced using the SELECT model v1.0.0 (Gao, J. & O'Neill, B.C. 2019). Default population data derived from Gao, J. & O'Neill, B.C. 2020. Original model outputs produced using the default population data are available from Gao, J. 2020. Updated United States population data derived from Zoraghein, H. & O'Neill, B.C. 2020. Other SELECT input files available at Gao, J. & O'Neill, B.C. 2022.

McManamay, Ryan↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Use of Navier-Stokes methods for the calculation of high-speed nozzle flow fields

Flows through three reference nozzles have been calculated to determine the capabilities and limitations of the widely used Navier-Stokes solver, PARC. The nozzles examined have similar dominant flow characteristics as those considered for supersonic transport programs. Flows from an inverted velocity profile (IVP) nozzle, an under expanded nozzle, and an ejector nozzle were examined. PARC calculations were obtained with its standard algebraic turbulence model, Thomas, and the two-equation turbulence model, Chien k-epsilon. The Thomas model was run with the default coefficient of mixing set at both 0.09 and a larger value of 0.13 to improve the mixing prediction. Calculations using the default value substantially underpredicted the mixing for all three flows. The calculations obtained with the higher mixing coefficient better predicted mixing in the IVP and underexpanded nozzle flows but adversely affected PARC's convergence characteristics for the IVP nozzle case. The ejector nozzle case did not converge with the Thomas model and the higher mixing coefficient. The Chien k-epsilon results were in better agreement with the experimental data overall than were those of the Thomas run with the default mixing coefficient, but the default boundary conditions for k and epsilon underestimated the levels of mixing near the nozzle exits.

Georgiadis, Nicholas J.↗

AXAF Coordinate Transformation at XRCF

Coordinate transformation between focal plane and detector pixel systems must be handled carefully at the X-ray Calibration Facility (XRCF) as it will be during flight. The High Resolution Mirror Assembly (HRMA) X-ray Detection System (HXDS) stage dithers, and the five-axis mount (FAM) attachment points underwent various types of motion during testing. At the XRCF when the FAM moved, the Science Instrument Module (SIM) travel direction was not necessarily aligned with the mirror axis motion, and, in addition, an arbitrary position offset had to be calibrated. Misalignment from the mirror axis was assessed by measuring its displacement from the boresight configuration of the default FAM frame, and the HXDS stage was monitored for motion from the default FAM reference point. Mirror position, prescribed in a mirror modal coordinate system, was measured in HRMA pitch and yaw axes. Prior to corrections for dithering and FAM movement, the coordinate data at XRCF also had to be corrected for possible misalignments of the mirror mount relative to XRCF and the default FAM axes due to the movement of the FAM feet. Those misalignments were processed in terms of yaw-pitch-roll Euler angles in the mirror nodal coordinate, and in the default FAM frame, respectively. An AXAF Science Center (ASC) coordinate library, pixlib, has been built to support these coordinate transformations and was used during x-ray calibration at the George C. Marshall Space Flight Center, Huntsville, AL. The design and implementation of this library will be discussed.

He, Helen↗

Dynamic Investment and Counterparty Risk

We introduce a dynamic optimization framework in which collateral is used to mitigate losses arising at counterparty’s default. The investor faces two sources of risk: the default risk of the entity referencing the traded credit swap security, and counterparty risk generated from the default event of the trading counterparty. We show that the value function of the control problem coincides with the classical solution of a nonlinear dynamic programming equation. We provide an explicit characterization of the optimal investment strategy, and show that the investor does not trade if counterparty risk is sufficiently high. These findings suggest that moving credit swap trades into well-designed clearinghouses may stimulate economic activities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automatic and rapid calibration of urban building energy models by learning from energy performance database

Urban building energy modeling (UBEM) is attracting increasing attention in the energy modeling filed. Unlike modeling a single building using detailed building systems information, UBEM generally uses limited high-level building stock data to infer default assumptions about building characteristics and operations. Additionally, this practice inherently brings uncertainty to UBEM. This study introduced a novel method of automatic and rapid calibration of UBEM based on the annual electricity and natural gas energy use data by learning the correlations between crucial model input parameters and the building energy use from the reference building models. A case study was presented to calibrate 72 large office buildings built before 1978 in San Francisco. Seventeen model parameters were selected and Monte Carlo sampling was used to create 1000 samples that reasonably represent the parameter space. Then 1000 simulations were performed for the reference building model to create an energy performance database. The results showed that by learning from the energy performance database, it took less than four simulation runs on average to calibrate a building model. After the calibration, the distributions of each parameter were obtained to replace their single predefined default values. For example, the default lighting power density of 21.39 W/m 2 was calibrated to be 7.50 W/m 2 on average. The case study successfully demonstrated the effectiveness of the novel calibration method for UBEM in the mild climate. The method will be further tested in future for other climate zones and other building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of distributed process-based hydrologic model performance using only a priori information to define model inputs

Fully distributed, integrated surface–subsurface hydrological models (ISSHMs) have seen renewed interest due to availability of better software, high performance computing facilities, and high-resolution, spatially extensive data products. ISSHMs are valuable as tools for advancing system understanding as they can resolve multiple processes defined on the plot scale including three-dimensional interaction of surface water and groundwater. Here, we evaluated the performance of an ISSHM, the Advanced Terrestrial Simulator (ATS), on seven diverse catchments across the continental US using widely available data products to define model inputs without calibration. We compare the ATS-simulated streamflow and evapotranspiration with gauge observations and MODIS-derived evapotranspiration, respectively. Using the Kling-Gupta Efficiency (KGE) as metric, ATS with default data products performed reasonably well at 6 of 7 catchments for streamflow. However, in one of those 6 catchments ATS had poor performance on baseflow and ATS’s overall performance was thus judged to be inadequate despite the acceptable KGE. ATS performance for evapotranspiration was good in all 7 catchments using default data products. In the two catchments where ATS streamflow performance using default data products was not acceptable, the performance was significantly improved by using local information on subsurface properties below the soil. We also compare the model-simulated streamflow and evapotranspiration with the Sacramento soil moisture accounting (SAC-SMA) model, a semi-distributed model that was calibrated on a catchment-by-catchment basis. Uncalibrated ATS performance is comparable to the calibrated SAC-SMA model in terms of streamflow while ATS performance is similar to or better (much better in certain catchments) in reproducing MODIS-derived evapotranspiration. Reasonably good performance of ATS without catchment-specific calibration provides new confidence in the ISSHM class of models and community data products as tools for advancing understanding of watershed function in a changing environment.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the interindividual human variation in bioactivation of methyleugenol using physiologically based kinetic modeling and Monte Carlo simulations

The present study aims at predicting the level of formation of the ultimate carcinogenic metabolite of methyleugenol, 1′-sulfooxymethyleugenol, in the human population by taking variability in key bioactivation and detoxification reactions into account using Monte Carlo simulations. Depending on the metabolic route, variation was simulated based on kinetic constants obtained from incubations with a range of individual human liver fractions or by combining kinetic constants obtained for specific isoenzymes with literature reported human variation in the activity of these enzymes. The results of the study indicate that formation of 1′-sulfooxymethyleugenol is predominantly affected by variation in i) P450 1A2-catalyzed bioactivation of methyleugenol to 1′-hydroxymethyleugenol, ii) P450 2B6-catalyzed epoxidation of methyleugenol, iii) the apparent kinetic constants for oxidation of 1′-hydroxymethyleugenol, and iv) the apparent kinetic constants for sulfation of 1′-hydroxymethyleugenol. Based on the Monte Carlo simulations a so-called chemical-specific adjustment factor (CSAF) for intraspecies variation could be derived by dividing different percentiles by the 50th percentile of the predicted population distribution for 1′-sulfooxymethyleugenol formation. The obtained CSAF value at the 90th percentile was 3.2, indicating that the default uncertainty factor of 3.16 for human variability in kinetics may adequately cover the variation within 90% of the population. Covering 99% of the population requires a larger uncertainty factor of 6.4. In conclusion, the results showed that adequate predictions on interindividual human variation can be made with Monte Carlo-based PBK modeling. For methyleugenol this variation was observed to be in line with the default variation generally assumed in risk assessment. - Highlights: • Interindividual human differences in methyleugenol bioactivation were simulated. • This was done using in vitro incubations, PBK modeling and Monte Carlo simulations. • Major enzymatic reactions causing interindividual differences were identified. • A chemical-specific adjustment factor (CASF) for intraspecies variation was derived. • The default uncertainty factor for kinetic human variability covers 90% of population.

60 APPLIED LIFE SCIENCES↗

The decay of wood in landfills in contrasting climates in Australia

Highlights: • We examine decay in wood from landfills in contrasting environments in Australia. • Analysis is based on changes in chemical composition and microscopy. • Climate did not influence levels of decay observed. • Microscopy of retrieved samples revealed most of the decay was aerobic in nature. • Current default factors for wood decay in landfills overestimate methane emissions. - Abstract: Wood products in landfill are commonly assumed to decay within several decades, returning the carbon contained therein to the atmosphere, with about half the carbon released as methane. However, the rate and extent of decay is not well known, as very few studies have examined the decay of wood products in landfills. This study reports on the findings from landfill excavations conducted in the Australian cities of Sydney and Cairns located in temperate and tropical environments, respectively. The objective of this study was to determine whether burial of the wood in warmer, more tropical conditions in Cairns would result in greater levels of decay than occurs in the temperate environment of Sydney. Wood samples recovered after 16–44 years in landfill were examined through physical, chemical and microscopic analyses, and compared with control samples to determine the carbon loss. There was typically little or no decay in the wood samples analysed from the landfill in Sydney. Although there was significant decay in rainforest wood species excavated from Cairns, decay levels for wood types that were common to both Cairns and Sydney landfills were similar. The current Intergovernmental Panel on Climate Change (IPCC, 2006) default decay factor for organic materials in landfills is 50%. In contrast, the carbon loss determined for Pinus radiata recovered from Sydney and Cairns landfills was 7.9% and 4.4%, respectively, and 0% for Agathis sp. This suggests that climate did not influence decay, and that the more extensive levels of decay observed for some wood samples from Cairns indicates that those wood types were more susceptible to biodegradation. Microscopic analyses revealed that most decay patterns observed in samples analysed from Sydney were consistent with aerobic fungal decay. Only a minor portion of the microbial decay was due to erosion bacteria active in anaerobic/near anaerobic environments. The findings of this study strongly suggest that models that adopt current accepted default factors for the decay of wood in landfills greatly overestimate methane emissions.

54 ENVIRONMENTAL SCIENCES↗

Large Ensemble Diagnostic Evaluation of Hydrologic Parameter Uncertainty in the Community Land Model Version 5 (CLM5)

Abstract Land surface models such as the Community Land Model version 5 (CLM5) seek to enhance understanding of terrestrial hydrology and aid in the evaluation of anthropogenic and climate change impacts. However, the effects of parametric uncertainty on CLM5 hydrologic predictions across regions, timescales, and flow regimes have yet to be explored in detail. The common use of the default hydrologic model parameters in CLM5 risks generating streamflow predictions that may lead to incorrect inferences for important dynamics and/or extremes. In this study, we benchmark CLM5 streamflow predictions relative to the commonly employed default hydrologic parameters for 464 headwater basins over the conterminous United States (CONUS). We evaluate baseline CLM5 default parameter performance relative to a large (1,307) Latin Hypercube Sampling‐based diagnostic comparison of streamflow prediction skill using over 20 error measures. We provide a global sensitivity analysis that clarifies the significant spatial variations in parametric controls for CLM5 streamflow predictions across regions, temporal scales, and error metrics of interest. The baseline CLM5 shows relatively moderate to poor streamflow prediction skill in several CONUS regions, especially the arid Southwest and Central U.S. Hydrologic parameter uncertainty strongly affects CLM5 streamflow predictions, but its impacts vary in complex ways across U.S. regions, timescales, and flow regimes. Overall, CLM5's surface runoff and soil water parameters have the largest effects on simulated high flows, while canopy water and evaporation parameters have the most significant effects on the water balance.

54 ENVIRONMENTAL SCIENCES↗

The impact of new Geant4-DNA cross section models on electron track structure simulations in liquid water

The most recent release of the open source and general purpose Geant4 Monte Carlo simulation toolkit (Geant4 10.2 release) contains a new set of physics models in the Geant4-DNA extension for improving the modelling of low-energy electron transport in liquid water (<10 keV). This includes updated electron cross sections for excitation, ionization, and elastic scattering. In the present work, the impact of these developments to track-structure calculations is examined for providing the first comprehensive comparison against the default physics models of Geant4-DNA. Significant differences with the default models are found for the average path length and penetration distance, as well as for dose-point-kernels for electron energies below a few hundred eV. On the other hand, self-irradiation absorbed fractions for tissue-like volumes and low-energy electron sources (including some Auger emitters) reveal rather small differences (up to 15%) between these new and default Geant4-DNA models. The above findings indicate that the impact of the new developments will mainly affect those applications where the spatial pattern of interactions and energy deposition of very-low energy electrons play an important role such as, for example, the modelling of the chemical and biophysical stage of radiation damage to cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigating high-energy proton-induced reactions on spherical nuclei: Implications for the preequilibrium exciton model

A number of accelerator-based isotope production facilities utilize $100-200$ MeV proton beams due to the high production rates enabled by high-intensity beam capabilities and the greater diversity of isotope production brought on by the long range of high-energy protons. However, nuclear reaction modeling at these energies can be challenging because of the interplay between different reaction modes and a lack of existing guiding cross section data. A Tri-lab collaboration has been formed between the Lawrence Berkeley, Los Alamos, and Brookhaven National Laboratories to address these complexities by characterizing charged-particle nuclear reactions relevant to the production of established and novel radioisotopes. In the inaugural collaboration experiments, stacked-targets of niobium foils were irradiated at the Brookhaven Linac Isotope Producer ($E_p=200$ MeV) and the Los Alamos Isotope Production Facility ($E_p=100$ MeV) to measure $^{93}$Nb(p,x) cross sections between $50-200$ MeV. The results were compared with literature data as well as the default calculations of the nuclear model codes TALYS, CoH, EMPIRE, and ALICE. The default code predictions largely failed to reproduce the measurements. Therefore, we developed a standardized procedure, which determines the reaction model parameters that best reproduce the most prominent reaction channels in a physically justifiable manner. Overall, the primary focus of the procedure was to determine the best parameterization for the pre-equilibrium two-component exciton model. This modeling study revealed a trend towards a relative decrease for internal transition rates at intermediate proton energies ($E_p=20-60$ MeV) in the current exciton model as compared to the default values. The results of this work are instrumental for the planning, execution, and analysis essential to isotope production.

43 PARTICLE ACCELERATORS↗