Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DECOUPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Moving-base visual simulation study of decoupled controls during approach and landing of a STOL transport aircraft

The simulation employed all six rigid-body degrees of freedom and incorporated aerodynamic characteristics based on wind-tunnel data. The flight instrumentation included a localizer and a flight director which was used to capture and to maintain a two-segment glide slope. A closed-circuit television display of a STOLport provided visual cues during simulations of the approach and landing. The decoupled longitudinal controls used constant prefilter and feedback gains to provide steady-state decoupling of flight-path angle, pitch angle, and forward velocity. The pilots were enthusiastic about the decoupled longitudinal controls and believed that the simulator motion was an aid in evaluating the decoupled controls, although a minimum turbulence level with root-mean-square gust intensity of 0.3 m/sec (1 ft/sec) was required to mask undesirable characteristics of the moving-base simulator.

Miller, G. K., Jr.↗

Decoupling control technology for medium STOL transports

The advanced control technology is considered that is necessary to cope with the medium STOL transport landing problem and, in particular, the necessity to decouple with active control techniques. It is shown that the need to decouple is independent of the powered lift concept but that the provisioning for decoupling is most greatly dependent on the preassumed piloting technique. The implications of decoupling and active control techniques with respect to pilot technique options, handling quality criteria, flight control mechanization, and the use of piloted simulation as a design tool, are also discussed.

Bird, D. K.↗

Perfect decoupling of linear systems with discrete parameter uncertainties

A design procedure based on Gilbert's decoupling parameters for determining a fixed state feedback control law which decouples a linear system with discrete parameter uncertainties is described. Perfect decoupling conditions are established which involve a test for the existence of a solution to a system of linear equations. An actual solution of the linear equations yields the decoupling control law.

Dorato, P.↗

Effects of errors on decoupled control systems

Various error sources in a decoupled control system are considered in connection with longitudinal control on a simulated externally blown jet-flap STOL aircraft. The system employed the throttle, horizontal tail, and flaps to decouple the forward velocity, pitch angle, and flight-path angle. The errors considered were: (1) imperfect knowledge of airplane aerodynamic and control characteristics; (2) imperfect measurements of airplane state variables; (3) change in flight conditions, and (4) lag in the airplane controls and in engine response. The effects of the various errors on the decoupling process were generally minor. Significant coupling in flight-path angle was caused by control lag during speed-command maneuvers. However, this coupling could be eliminated by including the control lag in the design of the decoupled system. Other error sources affected primarily the commanded response quantity.

Hamer, H. A.↗

Decoupled longitudinal controls for shear penetration in the terminal area environment

The use of decoupled longitudinal controls is simulated for the approach and landing of a twin engine jet transport in the presence of wind shear. Decoupled or independent control of pitch angle, flight-path angle and forward velocity using constant prefilter and feedback gains was compared to conventional control of a B-737 aircraft simulator. It is found that the mean flight-path angle, the mean glideslope error and the mean deviation in indicated airspeed generally improved when decoupled controls were used in the approach. An improvement in touchdown parameters was also observed, especially in strong shear, when 44% of conventionally-controlled flights impacted short of the runway. Simulator pilots reported improved approach performance and a reduced workload when decoupled controls were used.

Miller, G. K., Jr.↗

Residual fluctuations in the matter and radiation distribution after the decoupling epoch

The residual spectra of matter and radiation fluctuations in the early universe are investigated, and the evolution of primordial adiabatic and isothermal fluctuations through the decoupling epoch is studied. Amplification of adiabatic density fluctuations during decoupling, or velocity 'overshoot', is largely suppressed by Compton drag. Consequently, the amplitude of density fluctuations entering the horizon prior to decoupling is larger than hitherto assumed in the adiabatic theory. Damping of primordial adiabatic density fluctuations by an order of magnitude occurs on mass-scales of 3 x 10 to the 13th solar masses (Omega = 1) or 10 to the 14th solar masses (Omega = 0.2). Comparison of the residual radiation fluctuations with observational limits indicates that the adiabatic theory is only acceptable if re-ionization of the intergalactic medium results in additional scattering of the radiation after decoupling. Primordial isothermal fluctuations are found to yield radiation fluctuations which are insensitive to the assumed spectrum and lie a factor of about 5 below current limits

Silk, J.↗

Design of the annular suspension and pointing system /ASPS/ through decoupling and pole placement

A decoupling and pole-placement technique has been developed for the Annular Suspension and Pointing System (ASPS) of the Space Shuttle which uses bandwidths as performance criteria. The dynamics of the continuous-data ASPS allows the three degrees of freedom to be totally decoupled by state feedback through constant gains, so that the bandwidth of each degree of freedom can be independently specified without interaction. Although it is found that the digital ASPS cannot be completely decoupled, the bandwidth requirements are satisfied by pole placement and a trial-and-error method based on approximate decoupling.

Kuo, B. C.↗

Design and fabrication of the NASA decoupler pylon for the F-16 aircraft, addendum 1

The results of the final analyses which were conducted using a revised structural simulation of the Decoupler Pylon are reported in this addendum. The simulation incorporates the previously published results of ground tests performed on the flight Decoupler Pylons mounted in a test fixture at General Dynamic's Fort Worth facility. The analyses show that the Decoupler Pylon will suppress wing-store flutter for the GBU-8 flight test stores configuration on an F-16 airplane. The feasibility of carrying a B-61 on the pylons is also investigated with the conclusion that the pylons would need to be modified in order to demonstrate flutter suppression. The results of a ground vibration test performed on the 1/4 scale F-16 flutter model and a wind tunnel test with this model and a model Decoupler Pylon are given.

Clayton, J. D.↗

An Investigation in the Ames 40- by 80-Foot Wind Tunnel of a YT-56A Turboprop Engine Incorporating a Decoupler and a Controlled-Feathering Device

An investigation of a decoupler and a controlled-feathering device incorporated with the YT-56A turboprop engine has been made to determine the effectiveness of these devices in reducing the high negative thrust (drag) which accompanies power failure of this type of engine. Power failures were simulated by fuel cut-off, both without either device free to operate, and with each device free to operate singly. The investigation was made through an airspeed range from 50 to 230 mph. It was found that with neither device free to operate, the drag levels realized after power failures at airspeeds above 170 mph would impose vertical tail loads higher than those allowable for the YC-130, the airplane for which the test power package was designed. These levels were reached in approximately one second. The maximum drag realized after power failure was not appreciably altered by the use of the decoupler although the decoupler did put a limit on the duration of the peak drag. The controlled-feathering device maintained a level of essentially zero drag after power failure. The use of the decoupler in the YT-56A engine complicates windmilling air-starting procedures and makes it necessary to place operating restrictions on the engine to assure safe flight at low-power conditions,

Rogallo, Vernon L.↗

An Inviscid Decoupled Method for the Roe FDS Scheme in the Reacting Gas Path of FUN3D

An approach is described to decouple the species continuity equations from the mixture continuity, momentum, and total energy equations for the Roe flux difference splitting scheme. This decoupling simplifies the implicit system, so that the flow solver can be made significantly more efficient, with very little penalty on overall scheme robustness. Most importantly, the computational cost of the point implicit relaxation is shown to scale linearly with the number of species for the decoupled system, whereas the fully coupled approach scales quadratically. Also, the decoupled method significantly reduces the cost in wall time and memory in comparison to the fully coupled approach. This work lays the foundation for development of an efficient adjoint solution procedure for high speed reacting flow.

Thompson, Kyle B.↗

Surface‐Atmosphere Decoupling Prolongs Cloud Lifetime Under Warm Advection Due To Reduced Entrainment Drying

Abstract An initially well‐mixed stratocumulus deck can remain overcast for several tens of hours under warm‐advection conditions, although moisture supply is cut off from the ocean due to surface‐atmosphere decoupling (stabilization of the surface‐atmosphere interface). In this study, a set of idealized large‐eddy simulations were performed to investigate the physical mechanism of how warm‐air advection impacts the evolution of a pre‐existing stratocumulus deck. To mimic warm‐air advection, we decrease the sea surface temperature linearly over time in a doubly periodic domain. Given the same initial conditions, the stratocumulus deck is more persistent when experiencing warm‐air advection than cold‐air advection. This persistence is caused by reduced cloud‐top entrainment drying due to decoupling, a process more influential than the decoupling‐induced cutoff of moisture supply. This mechanism is more notable when the free troposphere becomes more humid. The relevance of the mechanism to previous observations of less low‐level cloudiness under warm‐advection conditions is discussed.

54 ENVIRONMENTAL SCIENCES↗

Study of the choice of the decoupling layout for the ITER ICRH system

10 decouplers are used to neutralize the mutual coupling effects and to control the current amplitude of the 24 straps array of the ITER ICRH antenna in the case of current drive phasing. In the case of heating phasing only 4 decouplers are active and the array current control needs to act on the ratio between the power delivered by the 4 generators. This ratio is very sensitive to the precise adjustment of the antenna array phasing. The maximum total radiated power capability is then limited when the power of one generator reaches its maximum value. With the addition of four switches all 10 installed decouplers are made active and can act on all mutual coupling effects with equal source power from the 4 generators. With four more switches the current drive phasing could work with a reduced poloidal phasing resulting in a 35% increase of its coupling to the plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

PMU-Based Decoupled State Estimation for Unsymmetrical Power Systems

Modal decomposition of measurement equations has already been shown to simplify the formulation and resulting computational complexity of three-phase state estimation of systems where all the transmission lines are three-phase and fully transposed. When there are non-transposed and/or mixed-phase lines, modal decomposition can no longer fully decouple the threephase measurement equations. Here, this paper addresses the above shortcoming by proposing a simple yet practical solution based on the commonly used numerical compensation techniques. Thus, it enables application of the powerful decoupling approach to any type of three-phase networks which may contain non-transposed or mixed-phase lines and are fully observable by PMUs. The proposed procedure modifies the measurement set by deriving additive terms that compensate for the neglected unsymmetrical effects. It will be shown that unbalanced systems including nontransposed and mixed-phase elements, can still be transformed into three decoupled subsystems and solved in parallel by the proposed approach. Performance of the proposed algorithm is validated against several IEEE test cases.

42 ENGINEERING↗

Dynamical Decoupling of Crosstalk on Superconducting Qubit Devices

Current NISQ devices are prone to errors. In order to be used for practical applications or achieve fault-tolerant thresholds, strategies to suppress error rates will be needed to maximize the potential of noisy devices. Dynamical decoupling (DD) is one such strategy for suppressing — or at least alleviating — the effects of decoherence, in which sequences of pulses are applied to qubits to decouple their interaction with the environment. Through experimental runs performed on several Rigetti quantum computing units (QPUs), we first demonstrate that DD is capable of improving coherence times for isolated qubits, as well as suppressing errors caused by the ZZ coupling between pairs of qubits. Extending this framework to cycles containing2-qubit gates, we show that DD can be inserted to decouple qubits from crosstalk occurring during neighboring 2-qubit gates, and demonstrate the efficacy of this procedure on quantum approximate optimization algorithm (QAOA) circuits. We also explore the usage of tailored DD sequences for the suppression of characterized error channels. We are grateful for support from the NASA Ames Research Center and from the DARPA ONISQ program under interagency agreement IAA 8839,Annex 114. HYH is supported by the USRA Feynman QuantumAcademy funded by the NAMS R&D Student Program and a UCHellman Fellowship. JS, ZGI and ZW are supported by USRA NASAAcademic Mission Service (NNA16BD14C).

Dynamical decoupling↗

Quantitative Decoupling of Oxygen-Redox and Manganese-Redox Voltage Hysteresis in a Cation-Disordered Rock Salt Cathode

Pronounced voltage hysteresis in Li-excess cathode materials is commonly thought to be associated with oxygen redox. However, these materials often possess overlapping oxygen and transition-metal redox, whose contributions to hysteresis between charge and discharge are challenging to distinguish. In this work, a two-step aqueous redox titration is developed with the aid of mass spectrometry (MS) to quantify oxidized lattice oxygen and Mn 3+/4+ redox in a representative Li-excess cation-disordered rock salt—Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO). Two MS-countable gas molecules evolve from two separate titrant-analyte reactions, thereby allowing Mn and O redox capacities to be decoupled. The decoupled O and Mn redox coulombic efficiencies are close to 100% for the LMTO cathode, indicating high charge-compensation reversibility. As incremental Mn and O redox capacities are quantitatively decoupled, each redox voltage hysteresis is further evaluated. Overall, LMTO voltage hysteresis arises not only from an intrinsic charge-discharge voltage mismatch related to O redox, but also from asymmetric Mn-redox overvoltages. The results reveal that O and Mn redox both contribute substantially to voltage hysteresis. In conclusion, this work further shows the potential of designing new analytical workflows to experimentally quantify key properties, even in a disordered material having complex local coordination environments.

25 ENERGY STORAGE↗

Drought-induced decoupling between carbon uptake and tree growth impacts forest carbon turnover time

The ability of forests to withstand, and recover from, acute drought stress is a critical uncertainty regarding the impacts of climate change on the terrestrial carbon (C) cycle, but it is unclear how drought responses scale from individual trees to whole forests. Here, we assembled a dataset of tree-ring chronologies co-located within the footprint of eddy covariance towers across North America and Europe, with the aim of quantifying the sensitivity of tree radial growth versus gross primary productivity (GPP) during and following drought. We found that drought induced a large decoupling across C cycle processes, whereby GPP was relatively resistant to water stress despite large reductions in tree-ring widths. This decoupling also occurred in the year following drought (i.e., a ‘drought legacy effect’), and was similar in magnitude in response to both summer and winter droughts. By modeling whole-forest C turnover time, we show that a radial growth-GPP decoupling has important ramifications for the forest C cycle, especially if the C not used to support radial growth is instead allocated towards pools with short residence times. Furthermore, our results demonstrate that quantifications of drought impacts that rely solely on C uptake are missing this fundamental pathway through which drought alters the forest C cycle and the resulting feedbacks to the climate system.

54 ENVIRONMENTAL SCIENCES↗

Wide-Area Measurement-Based Modal Decoupling for Power System Oscillation Damping

Inter-area oscillation modes usually fall within the same frequency range of 0.1 to 1.0 Hz; thus, power oscillation damping (POD) control methods should avoid unnecessary excitation of weakly damped modes. This paper presents a decoupled control strategy to damp inter-area oscillations in the power grid. Pure oscillation mode signals are extracted from wide-area measurements and used as feedback input for POD actuators such as power system stabilizers or high-voltage direct current transmission. The decoupled control strategy is able to increase the damping of the concerned oscillation modes without deteriorating others. This proposed strategy could be implemented independently, or serve as a complement and work along with conventional POD controllers to damp concerned inter-area modes. The proposed method has been tested on a modied MinniWECC system. Extensive results indicate that inter-area oscillations can be successfully and precisely damped using the proposed decoupled strategy.

Fan, Rui↗