Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Research needs targeting direct air capture of carbon dioxide: Material & process performance characteristics under realistic environmental conditions

The extraction of CO 2 from ambient air, or direct air capture (DAC), is a crucial negative CO 2 emissions technology with great potential for contributing to the mitigation of global warming and climate change. Furthermore, nearly all published research on DAC has been conducted under indoor temperature conditions, i.e. 20 to 30 °C. In contrast, the future global implementation of DAC requires it to be operational across a wide expanse of geographical areas, of which the local temperatures can vary between -30 to 50 °C. Similarly, the absolute humidity can vary from ~0 to 84 g/m 3 in various locations. Due to the massive amount of air that would be processed, it may be impractical to preheat or dehumidify the air before the CO 2 separation. Therefore, it is important to develop DAC materials with good performance at realistic outdoor conditions, especially at sub-ambient conditions, i.e. -30 to 20 °C. In addition to material development, system-level studies at sub-ambient conditions are also needed for the DAC processes to reach optimal designs, which may be very different from those at ambient conditions. In this perspective article, we first assess the literature to identify the technical gaps that need to be filled for DAC to be applicable at realistic outdoor conditions. We then suggest additional research directions needed for DAC to be viable under varied conditions from the perspectives of materials and system designs. For materials, we discuss the expected physical and chemical property changes for the sorbents when the temperature or humidity reaches extremes within their range, and how that will impact performance. Similarly, for system design, we indicate how varied conditions will impact performance and how these changes will impact process optimization.

20 FOSSIL-FUELED POWER PLANTS↗

An effective air–liquid contactor for CO 2 direct air capture using aqueous solvents

Here, the development of a cost-effective, corrosion resistant, high-flux direct air capture (HiDAC) contactor for a solvent-based direct air capture (DAC) process is reported. Literature technoeconomic analyses suggest that the air–liquid contactor can cost over 20 % of the overall DAC plant’s annualized capital costs. To bring down the overall cost of DAC, it is imperative that an effective contactor is developed. A hybrid contactor consisting of a commercial polyvinylchloride structured packing enhanced with stainless-steel 410 random packing has been developed to provide a high surface area for air–liquid contact. The contactor geometry, wettability, corrosion resistance, pressure drop, along with its CO 2 uptake efficiency, CO 2 uptake rates, and extended loading potential using potassium sarcosinate solutions are investigated. Results show that the HiDAC contactor has a relatively high specific surface area (885 m 2 /m 3 ), which allows for CO 2 uptake efficiencies of up to 75 % and capture rates of up to 550 g of CO 2 per day for a 0.3 × 0.25 × 0.3 m contactor. The contactor also exhibits high levels of wettability and corrosion resistance with amino acid-based DAC solvents. A CO 2 uptake model was developed, and modeling results are compared to experimental data to simulate and predict the performance of the contactor in a DAC process using potassium sarcosinate solvent. The system’s overall mass transfer coefficient and theoretical pressure drop were also calculated, and these results were compared to DAC data found in literature. The results presented indicate that the HiDAC contactor is well suited for DAC due to its high specific surface area, resistance to corrosion, and high degree of wettability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemically Regenerated Solvent for Direct Air Capture with Co-generation of Hydrogen at Bench-scale

The goal of this final project report is to summarize the work conducted on project DE-FE0032125. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Institute for Decarbonization and Energy Advancement (UK IDEA) (Recipient) developed an intensified process to capture CO 2 from ambient conditions (415 ppm CO 2 ). The process combines low-temperature solvent-aided membrane capture with electrochemically-mediated solvent regeneration to simultaneously capture ambient CO 2 while regenerating the solvent. The technology employs only two primary units, a regenerator and an absorber/contactor, while generating high purity hydrogen as a co-product that can be sold, used for energy storage, or cost-saving depolarization of the direct air capture (DAC) system during the grid peak demand, allowing for flexible operation. Since the technology is powered directly by DC electricity, it can seamlessly tie in with power sources like solar cells without the need for AC/DC converters, therefore allowing for a remote operation to further mitigate greenhouse gas generation toward deploying a negative carbon emissions technology that is completely decoupled from the carbon emissions from the power source for the DAC unit. The completion of the project results in significant progress toward the Department of Energy’s (DOE’s) goal of advancing lab and bench-scale DAC systems to a sufficient maturity level that can justify their continued scale-up through the verification testing of the electrochemically regenerated solvent system for DAC with co-generation of hydrogen at bench-scale. The technology addressed the complexities of incumbent DAC systems by demonstrating at ambient conditions (1) low gas-side pressure-drop facile CO 2 capture via an intensified membrane absorber with in-situ regenerated hydroxide as capture solvent, (2) multi-functional electrochemical regenerator for hydroxide regeneration, CO 2 concentration and hydrogen production at less than 3 V, and (3) stable DAC performance including >90% capture with air influent at the CFM scale. The data from this project enables the completion of Techno-Economic Analysis (TEA) and Life Cycle Assessment (LCA). TEA and LCA demonstrate the potential of the proposed electrochemical solvent-based process to be a viable DAC option. The analysis did not identify any obvious concern for the bench-scale operation and no apparent barriers to implementing UK IDEA carbon capture and solvent regeneration system at a larger scale.

08 HYDROGEN↗

Bench-Scale Testing of Monolithic PPI Structured Contactors for Direct Air Capture of CO 2

The overall project objective was to develop, optimize and bench-scale test the integrated embodiment of a leading direct air capture (DAC) sorbent composition, linear-poly(propylenimine) (l-PPI), in a structured material system, specifically a monolithic contactor for achieving low pressure drop, to justify its further scale-up in a subsequent program. The project team was led by CORMETECH, a leading monolithic gas/solid contactor manufacturer for environmental applications, and included Global Thermostat, a well-known DAC start-up, and Georgia Tech, a prominent US academic institution in carbon capture and DAC. The monolithic contactor for l-PPI in this project employed an advanced, cost-effective fabrication technique from CORMETECH, namely a porous monolith substrate directly impregnated with the amine, an approach contrasting to the traditional wash-coating methods used for activating monoliths. The l-PPI monolithic contractor is targeted for use in DAC systems such as the Global Thermostat DAC process, which involves the cyclic operation of ambient air flow over a monolithic amine contactor followed by steam-mediated thermal desorption and CO 2 collection, maximizing volumetric productivity while reducing the auxiliary power required to capture CO 2 from air. The Global Thermostat DAC process currently utilizes poly(ethyleneimine) (PEI) materials as baseline sorbents, which are subject to oxidative degradation and slow capacity fade at the elevated temperature required for efficient CO 2 removal. Georgia Tech, with Global Thermostat, had discovered in lab-scale efforts that l-PPI had superior resistance to oxidative degradation compared to PEI, with similar CO 2 adsorption capacity. While the novel l-PPI sorbent offers significant advantages over PEI for DAC, including potential design simplification and increased process efficiency, it is not commercially available, and prior to this project, had not yet been evaluated on the bench-scale in a structured contactor.

36 MATERIALS SCIENCE↗

Assessment of Amine-Based CO2BOLs for Direct Air Capture

Direct air capture (DAC) technologies extract CO 2 from the atmosphere for CO 2 storage, or utilization. Capturing CO 2 from the air is the most expensive application of carbon capture because CO 2 in the atmosphere is very dilute. There are limited number of CO 2 capture technologies for DAC application. This project aims at developing an energy efficient technology for DAC, leveraging two PNNL’s chemistries (solid and liquid CO 2 capture). Three CO 2 capture sorbents consisting of amine based CO 2 BOLs immobilized in mesoporous silica were designed, synthesized, and tested. These sorbents had ~ 19-23 wt.% amine loadings which is lower than typical amine-based silica sorbents. The surface area and pore volumes of these solid supported CO 2 BOLs are lower compared to those of the pristine silica support. The CO 2 capture performance of these materials was significantly lower than the typical silica supported amines due to low amine loading and higher molecular weight with low amine density. These results show that immobilize CO 2 BOLs in silica are not viable materials for removing CO 2 from ambient air. This project also designed, synthesized at tested liquid solvents for DAC application. Solvent properties that is vapor pressure, CO 2 uptake capacity, kinetics, and viscosity for three novel solvents were evaluated. The CO 2 uptake capacity for one of the most promising amine-based solvent BEPBEGDA was the highest at 13.2 wt% corresponding to 97 mol%. The vapor pressure of the BEPBEGDA solvents were very low at 80 °C compared to other solvents making them suitable for DAC application. The effect of humidity on the CO 2 capture performance of these solvents was evaluated which shows that presence of moisture doesn’t have a negative effect on the CO 2 uptake performance but makes it slightly better. The performances of these solvents were slightly below that of the 0.1M NaOH solution tested under similar conditions. Despite of the slightly lower CO 2 uptake, it is expected that these liquid solvents will have lower regeneration temperature and minimum evaporative losses due their low vapor pressure. Future work will focus on optimization of the liquid solvents for DAC application to improve both CO 2 capture efficiency and capacity without viscosity and vapor pressure increase. Testing of these solvents under DAC conditions using a gas liquid contactor that mimic industrial applications is needed. Solvent cost projection, techno-economic analysis and life cycle analysis are required to evaluate economic viability of this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scaleup and Site-Specific Engineering Design for Global Thermostat Direct Air Capture Technology

The overall goal of the project is completion of an initial design of a commercial-scale, Carbon Capture, Utilization, and Storage Direct Air Capture (CCUS-DAC) plant design at three different sites that captures a net of at least 100,000 tonnes per year (TPY) carbon dioxide (CO 2 ) from the atmosphere and considers compression and conditioning of the captured CO 2 for purpose of pipeline transportation to different geological formation sites for deep well injection and underground storage. In addition to the leading system consisting of a scaled-up Global Thermostat DAC unit, overall plant design includes a combined Heat and Power (CHP) unit integrated with a conventional liquid amine-based carbon capture system (90% capture) and compression facilities. These are considered balance of plant (BOP) systems and are required to provide low carbon-intensity steam and power to the DAC process. A second approach involving provision of DAC units modified to directly capture emissions from the CHP unit was initially assessed as an alternative and it was determined to be less mature than considered approach and not included in the scaled-up plant design efforts. Three geographically diverse continental United States locations were selected to better understand the effect of local/regional ambient conditions on scaled-up DAC system performance and project costs: Bucks, Alabama (hot wet climate), Odessa, Texas (dry hot climate), and Goose Creek, Illinois (mid continental climate). The team focused on initial engineering design activities, including the development of project design criteria, initiation of site-specific studies and investigations, completion of DAC system process and equipment design, and definition of balance of plant (BOP) engineering. The purpose of the activities were to develop Technoeconomic Analysis (TEA), Life-Cycle Analysis (LCA), and Environmental, Health, and Safety (EH&S) analysis, and Business Case Analysis (BCA) to validate that the project engineering and scale-up plans of the DAC systems, at each of the three distinct case studies considered, are technically, economically, and environmentally feasible for commercial-scale operation.

20 FOSSIL-FUELED POWER PLANTS↗

Sub-Ambient Performance of Potassium Sarcosinate for Direct Air Capture Applications: CO 2 Flux and Viscosity Measurements

Absorption based direct air capture (DAC) technologies have garnered significant interest in recent years due to their scalability, competitive regeneration energy requirements, and low susceptibility to degradation. One of the key advantages of DAC lies in its flexible siting options and the potential to utilize low-value land. However, most of the research in this field has been focused on ambient climate zones (T > 20 °C), overlooking sub-ambient (–30 °C < T < 20 °C) regions, which comprise approximately 70 % of the Earth’s surface. To fully realize the potential of DAC, it is essential to understand how DAC solvents perform in these sub-ambient conditions before any large-scale deployment can be considered. Among DAC solvents of interest, potassium sarcosinate (K-SAR) has emerged as a promising candidate due to its high CO 2 capacity, fast uptake kinetics, compatibility with contactor packing materials, low volatility, good thermal and oxidative stability, and competitive regeneration energy requirements compared to current industry standards. This paper characterizes the CO 2 flux and viscosity of K-SAR at sub-ambient conditions and explores the potential of using ethylene glycol and triethylene glycol as additives to prevent solvent freezing in DAC applications. For 1 M K-SAR, the CO 2 flux ranges between 1.3 × 10 -5 and 8.0 × 10 -5 mol m –2 s –1 across a temperature range of –5 °C to 45 °C. Ethylene glycol is shown to effectively suppress the freezing point of K-SAR below –30 °C with volumetric loadings of the additive as low as 0.1. Here, a reaction model was developed to predict the CO 2 flux for 1 M K-SAR at different temperatures, demonstrating good agreement between experimental and theoretical fluxes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The cost of direct air capture and storage can be reduced via strategic deployment but is unlikely to fall below stated cost targets

Carbon dioxide removal (CDR) is necessary to minimize the impact of climate change by tackling hard-toabate sectors and historical emissions. Direct air capture and storage (DACS) is an important CDR technology, but it remains unclear when and how DACS can be economically viable. Here, we use a bottom-up engineering-economic model together with top-down technological learning projections to calculate plant-level cost trajectories for four DACS technologies. Our analysis demonstrates that the costs of these technologies can plateau by 2050 at around $\$$100-600 t-CO 2 -1 mainly via capital cost reduction through aggressive deployment, but still exceed the optimistic targets defined by countries such as the US (i.e., $\$$100 t-CO 2 -1 ). A further analysis of existing policy mechanisms indicates that strong, project-catered policy support will be required to create market opportunities, accelerate DACS scale-up and lower the costs further. Our work suggests that strategic DACS deployment and operation must be coupled with strong policies to minimise the cost of DACS and maximise the opportunity to make a planet-scale climate impact.

54 ENVIRONMENTAL SCIENCES↗

Model-Based Energy and Cost Analysis of Direct Air Capture Using ePTFE-Based Laminate-Structured Gas–Solid Contactors

Carbon dioxide removal (CDR) technologies will play a significant role in limiting global warming if implemented on a large scale. Direct air capture (DAC) is a scalable approach for removing atmospheric carbon, yet the true scope of its scalability remains unclear due to the early stage of technology development and high first plant costs. This study provides groundwork for understanding the technoeconomic trade-offs in developing DAC systems using laminate-structured gas–solid contactors, encompassing the analysis of both contactor and process design spaces. The robust mass transfer and process models outlined in this study provide tools for evaluating DAC processes and designing DAC plants based on cost and energy analysis. First, the key contactor geometrical parameters are identified to understand the CO 2 productivity–energy demand trade-offs, where geometries yielding higher mass transfer rates can achieve higher CO 2 productivities at the expense of energy consumption by fans and steam use. Next, a detailed process parametric study is conducted for DAC systems coupled with steam-assisted temperature-vacuum swing adsorption (S-TVSA) to visualize the trade-offs in the multidimensional design space. The main cost driver dramatically changes over different process conditions, but the operating cost prevailed on the Pareto front, with potential to operate as low as 150 $/tonne-CO 2 (within the cost range of 148–504 $/tonne-CO 2 in this study where the DAC system is coupled with industrial facilities for steam production).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmental trade-offs of direct air capture technologies in climate change mitigation toward 2100

Abstract Direct air capture (DAC) is critical for achieving stringent climate targets, yet the environmental implications of its large-scale deployment have not been evaluated in this context. Performing a prospective life cycle assessment for two promising technologies in a series of climate change mitigation scenarios, we find that electricity sector decarbonization and DAC technology improvements are both indispensable to avoid environmental problem-shifting. Decarbonizing the electricity sector improves the sequestration efficiency, but also increases the terrestrial ecotoxicity and metal depletion levels per tonne of CO 2 sequestered via DAC. These increases can be reduced by improvements in DAC material and energy use efficiencies. DAC exhibits regional environmental impact variations, highlighting the importance of smart siting related to energy system planning and integration. DAC deployment aids the achievement of long-term climate targets, its environmental and climate performance however depend on sectoral mitigation actions, and thus should not suggest a relaxation of sectoral decarbonization targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Near-cryogenic direct air capture using adsorbents

Direct air capture (DAC) of CO 2 is a key component in the portfolio of negative emissions technologies for mitigating global warming. However, even with the most potent amine sorbents, large-scale DAC deployment remains limited by high energy and capital costs. Recently, adsorbents relying on weak interactions with CO 2 have emerged as a potential alternative, thanks to their rapid adsorption kinetics and superior long-term stability, particularly under sub-ambient conditions (∼253 K). Despite these advantages, their use is hindered by the need for a water-removal process, location-specific constraints, and insufficient working capacity even in cold climates. In this study, we hypothesized that further reducing the adsorption temperature to a near-cryogenic range (160–220 K) could enable cost-effective DAC by utilizing the full potential of physisorbents. We primarily consider integrating DAC with a relatively untapped source of cold energy—liquified natural gas (LNG) regasification—to perform near-cryogenic DAC. From large-scale molecular simulations, Zeolite 13X and CALF-20 were identified as promising candidates. These materials were subsequently examined through experiments, including breakthrough analyses at 195 K. Their high CO 2 sorption capacity (4.5–5.5 mmol g −1 ), combined with a low desorption enthalpy and robust long-term stability, led to a threefold reduction in the levelized cost of capture (down to 68.2 USD per tonne CO 2 ). Estimates of the global LNG regasification resource suggest that LNG–DAC coupling could potentially enable the capture of 103–142 megatonnes of CO 2 annually as of 2050.

Kim, Seo-Yul [Georgia Institute of Technology, Atl↗

Mining Air for Fuels and Fine Chemicals

The Intergovernmental Panel on Climate Change’s 2021 report underscores that Direct Air Capture (DAC) is an essential component to limiting global warming to 2 °C, yet separating CO 2 from air and its subsequent concentration for conversion into carbon neutral fuels/chemicals or permanent storage remains energy intensive and costly. Further, most DAC technologies rely on repetitive capture and release cycles that reduces the amount of time the DAC materials are able to collect CO 2 and increases wear and tear. Moisture swing (MS) sorption within anion exchange materials utilizes differences in relative humidity to capture and concentrate CO 2 up to 500-fold with negligible energy inputs and low-cost sorbents. Molecular modeling predicts that membranes with a dry and wet side would actively transport CO 2 from its dry side to its wet side against a counter flow of H 2 O evaporating on the dry side, however, existing MS materials are too brittle to be processed into membranes to test this hypothesis. This project brought together experts in DAC materials and design, techno-economic analysis and project management at Arizona State University (ASU), polymer processing at University of Texas at Austin (UTA) and modeling gas transport and exchange at Norther Arizona University (NAU) to develop hollow fiber membranes that use energy from water evaporation to continuously pump CO 2 from air against a concentration gradient to the membranes interior and requiring significantly less energy than current DAC technologies. While this project did not meet its ultimate objectives of demonstrating an active CO 2 pumping membrane, a number of key accomplishments were made in developing low-cost, flexible anion exchange membranes (AEM) at 3.5 m 2 scale, characterizing the ionic and molecular transport within MS materials, and developing several analytical and mathematical models of the MS and pumping process leading to new fundamental knowledge about key rate limiting steps of CO 2 flux in anion exchange membranes at low water activity. Technoeconomic models show that if CO 2 fluxes ≥ 25 µmol CO 2 m -2 s -1 (membrane surface area) are achieved that cost ≤ $\$$100/tonne CO 2 captured, purified and compressed to pipeline quality is possible. The knowledge gained in this research will guide future research in developing new materials toward overcoming these rate limiting steps that in turn could enable transformative and disruptive DAC technologies needed for capturing gigatons of CO 2 per year needed to limiting global warming to 2 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Advanced Solid Sorbents for Direct Air Capture (Final Report)

RTI International is partnering with Creare, and Mohammed VI Polytechnic University (UM6P) successfully met all major technical objectives as outlined below: Identified one MOF adsorbent for DAC; Identified one amine-P-dendrimer adsorbent for DAC; Performed Computational fluid dynamics simulations of the MOF and amine-P-dendrimer adsorbents and validate them with experimental data; Selected one adsorbent for DAC; Demonstrated the scale-up of selected candidate and perform cost review; Performed a preliminary process design; Performed technology maturation plan and environmental health and safety risk assessment. After a thorough comparison between both adsorbents (MOFs and P-dendrimers) and based on their technical merits, the amine-based P-dendrimers sorbent was selected as the best performing adsorbent for DAC. In fact, the amine-based P-dendrimers have demonstrated superior performance over the MOF sorbents under relevant DAC conditions. The selected sorbent has been used in subsequent projects (DE-FE0032099 and DE-AR0001412) and has demonstrated similar superior performance with no loss of activity after long-term sorption-desorption testing (e.g., 100 cycles). This sorbent has demonstrated a very high and stable sorption performance, excellent kinetics, and fast regeneration at 80 °C, specifically at 75% relative humidity (RH). The incorporation of RTI’s high-performance, high-durability amine-based P-dendrimers sorbent and Creare’s hybrid additive manufacturing (H-AM) technology that will produce high performance, compact heat and mass exchange structures at low cost using methods, will lead to a contactor that is optimized for wind-driven operation. This contactor technology provides a technically viable pathway for reducing the cost of DAC to <$100/tonne of CO 2 .

36 MATERIALS SCIENCE↗

Initial Systems-Level Assessment of a Distributed Direct Air Capture System Concept at the Urban-scale (UrbanDAC)

Direct Air Capture (DAC) systems offer a promising solution for mitigating global carbon emissions by directly removing ambient carbon dioxide (CO 2 ) from the atmosphere. While future DAC facilities are typically envisioned as being large and centralized, small-scale systems present an alternative approach with advantages such as adaptability and lower uptake costs. By harnessing waste heat from the built environment, such small-scale systems become distributed DAC at the urban scale (UrbanDAC) that benefit from existing urban infrastructure, while presenting challenges such as identifying eligible buildings and sustainable transportation and storage of captured CO 2 . Collaborating with engineering experts and developers of a DAC unit that can be co-located with cooling towers of existing commercial buildings, this study explores the systems-level implications of UrbanDAC using a geographically explicit multi-decision criteria analysis (MCDA) framework. By considering various infrastructure and environmental factors, network analysis and geospatial techniques are applied to identify optimal building candidates for distributed DAC units within Knoxville, Tennessee, USA, as a representative mid-size city. The selected outputs of the MCDA are used to explore a scenario that assumes a CO 2 collection and transport route for 20 high-ranking candidate buildings; total carbon emissions, EV energy consumption, and net carbon dioxide removal (CDR) are then calculated. Results suggest that the spatial variation of optimal candidates between thriving commercial areas is an important planning consideration. Examining the feasibility of UrbanDAC at an urban planning level provides valuable insights into the barriers and enabling conditions for CDR in cities, where the vast majority of CO 2 emissions are produced, and supports decision-making processes for the implementation of decarbonization initiatives. Through this initial assessment, this research acts as a pilot study for an emerging technology that highlights the importance of distributed DAC technologies in addressing climate change and emphasizes the need for further research and exploration in this domain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable Aviation Fuels from 30,000 feet – Scoping Report

A literature review, first principles analysis, and mapping of the airline-fuel infrastructure were performed to reassess the potential for various means of realizing a sustainable aviation sector. The literature review found a plethora of technical methods to make the airline industry net-zero CO 2 but limited work on the emergent barriers to sustainable aviation implementation such as land use, repurposing of fuel refining assets, and airline cost structures. First principles analyses of the energy, land, and costs of three broad net-zero strategies were performed to determine if sustainable aviation is feasible even in the most optimistic scenarios. Those methods were biomass-derived sustainable aviation fuel (SAF), fuel produced from CO 2 captured from the air and H 2 produced from water electrolysis (air-to-fuel: ATF), and offsetting fossil-derived Jet Fuel with carbon dioxide removal from the atmosphere (direct air capture and storage: DACS). Offsetting CO 2 emissions from using fossil Jet Fuel with DACS was found to consume the least energy, require the smallest quantity of land, and be the cheapest option. Replacing Jet Fuel with SAF was found to be only slightly more expensive than DACS but require substantially more land. ATF was found to be the most expensive and energy intensive option, though it did spare land relative to SAF. We found that calls to utilize waste biomass are well-founded, but wastes alone cannot cover the needs of the global airline industry. This means additional land will need to be allocated for biomass cultivation if SAF becomes the primary pathway to sustainable aviation. While differences were found in the performance of different types of biomass, those differences were small relative to differences with ATF and DACS. An analysis of the pricing structure of the airline industry suggests that some of the cost advantage of DACS may be erased by consumer sentiment which could explain why, to-date, the airline industry is focused primarily on SAF and to a lesser extent ATF. Further work is required to estimate the transportation, capital cost, and financing cost implications of greenfield and brownfield sites for SAF, DACS, and ATF. In the final report, we will analyze the potential to retrofit corn ethanol facilities to operate the ethanol-to-jet fuel process in response to decreasing gasoline demand as the electrification of road transport progresses. We will also construct a prioritization of land use to determine whether each net-zero CO 2 aviation pathway can make claim to the land required by their technology.

09 BIOMASS FUELS↗

Abstract for CRADA between NETL and the AZ Board of Regents on behalf of Arizona State University

Arizona State University (ASU) and the National Energy Technology Laboratory (NETL) will collaborate on the development and scale up of sorbent composites that efficiently capture carbon dioxide (CO 2 ) directly from air under an awarded project from the Department of Energy’s Direct Air Capture (DAC) Pre-Commercialization Technology Prize. For DAC to be considered a viable technology for decarbonization, the cost of carbon removal needs to decrease below the proposed carbon tax incentive outlined in the recent Inflation Reduction Act (IRA) (Section 45 Q), which is set at $\$$180 per ton of CO 2 . Achieving this goal requires the development of a cost-effective, environmentally friendly sorbent with high CO 2 sorption capacity and efficient kinetics under DAC conditions as the overall cost of CO 2 captured is highly sensitive to factors such as sorbent cost and sorbent lifetime. ASU has developed a sorbent technology that can potentially reduce CO 2 removal costs by DAC. NETL has expertise in DAC TEA and LCA development and DAC sorbent testing. The collaboration between ASU and NETL aims to accelerate development and deployment of ASU’s technology by quantifying the performance, cost and lifecycle impacts of ASU’s technology and validating sorbent performance.

54 ENVIRONMENTAL SCIENCES↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

NETL Direct Air Capture Center

In 2022 Congress authorized the $25M National Energy Technology Laboratory Direct Air Capture Center. The facility will be specifically targeted at accelerating the commercialization of technologies beyond the conceptual stage which have not yet reached full pilot-scale (TRL 3 to 6). The ability to operate over a wide range of conditions will help the developers to understand how their technologies respond in different climates, from summer to winter and arid to tropical. NETL recognizes that DAC technology is still early in its evolution, and a wide variety of highly varied technologies are being explored. The Center will be designed with substantial flexibility to accommodate the rapidly evolving technological landscape. Testing systems at three scales will be included: lab-scale systems designed to examine the long-term stability of DAC materials, bench-scale module testing systems capable of probing flow dynamics, and small pilot-scale skid rooms able to test prototype DAC units under a wide variety of climate conditions. The NETL DAC Center will feature dedicated engineering, technician, scientific and logistical support for experimental system design, installation, operation of experiments, and interpretation of results for projects including but not limited to kinetics of absorption/desorption, thermal duty, and post-mortem elemental characterization to understand degradation. The NETL DAC Center projects will also have access to dedicated process modeling and analysis to evaluate the technoeconomic aspects of new technologies. NETL’s Systems Engineering and Analysis (SEA) team, the Carbon Capture Simulation Initiative (CCSI), and the Institute for the Design of Advanced Energy Systems (IDAES) are all potential collaborators with NETL’s testing partners from industry, academia, and other research institutions. NETL also has world class capabilities in device scale modeling (i.e., MFIX) that will be available to help design more efficient contactors and optimize unique internal configurations that can be realized by advanced manufacturing. The talk will cover the design and capabilities of the center, the planned availability, and feedback will be solicited from the audience on DAC testing needs.

Luebke, David↗