Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cyber Physical Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cyber-Physical System Security With Deceptive Virtual Hosts for Industrial Control Networks

A challenge facing industrial control network administrators is protecting the typically large number of connected assets for which they are responsible. These cyber devices may be tightly coupled with the physical processes they control and human induced failures risk dire real-world consequences. Dynamic virtual honeypots are effective tools for observing and attracting network intruder activity. This paper presents a design and implementation for self-configuring honeypots that passively examine control system network traffic and actively adapt to the observed environment. In contrast to prior work in the field, six tools were analyzed for suitability of network entity information gathering. Ettercap, an established network security tool not commonly used in this capacity, outperformed the other tools and was chosen for implementation. Utilizing Ettercap XML output, a novel four-step algorithm was developed for autonomous creation and update of a Honeyd configuration. This algorithm was tested on an existing small campus grid and sensor network by execution of a collaborative usage scenario. Automatically created virtual hosts were deployed in concert with an anomaly behavior (AB) system in an attack scenario. Virtual hosts were automatically configured with unique emulated network stack behaviors for 92% of the targeted devices. The AB system alerted on 100% of the monitored emulated devices.

97 MATHEMATICS AND COMPUTING↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Modeling and simulation for cyber-physical system security research, development and applications.

This paper describes a new hybrid modeling and simulation architecture developed at Sandia for understanding and developing protections against and mitigations for cyber threats upon control systems. It first outlines the challenges to PCS security that can be addressed using these technologies. The paper then describes Virtual Control System Environments (VCSE) that use this approach and briefly discusses security research that Sandia has performed using VCSE. It closes with recommendations to the control systems security community for applying this valuable technology.

99 GENERAL AND MISCELLANEOUS↗

Data-based and secure switched cyber–physical systems

In this work, we develop a completely model-free moving target defense framework for the detection and mitigation of sensor and/or actuator attacks in cyber–physical systems with dynamics that evolve in discrete-time. We incorporate an intrusion detection mechanism based on an approximate dynamic programming technique that learns the policies for optimal regulation and optimal tracking while simultaneously defending against actuator and sensor attacks in a model-free fashion. Switching rules are leveraged to force proactive and reactive defense mechanisms as well as, guarantee the stability of the equilibrium point. Finally, as a case study, we apply the proposed moving target defense framework to a DC–DC converter that is used in electric vehicles.

42 ENGINEERING↗

Cyber-Physical Power Systems Protection: The Byzantine Cybersecurity Framework

Cybersecurity of smart grids have been topic of much interest in recent years. As this critical infrastructure operation increases dependency on automated processes and controls, exposure to cyber-physical threats become inevitable. Considering cyber-physical security of the grid, much focus of attention has been made towards smart grids real-time monitoring solutions, including the state estimation process. Analyzing the relevant literature, one can note though that seldom research has been done on cyber-physical security of smart grids protection systems. Protection systems have intangible value towards grid reliability. This paper presents a cybersecurity framework for smart grids protection systems. A physics-based inspired machine learning solution is at the core process of the framework. Processed relay inputs and outputs are used by a deep predictive coding network. Formal models, a quasi-static state estimator, provides an oracle when low confidence decision is reached. Evolving knowledge is derived through reinforcement learning. Implementation aspects considering the Pacific Northwest National Laboratory Electricity Infrastructure Operations Center are presented. Built as an extra control layer to protection systems, without hard-to-derive parameters, highlights potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Overview of Security and Privacy in Cyber-Physical Systems

Cyber-physical systems (CPS) are used across domains to enable process optimization and previously unachievable functionality. The combination of networked digital systems and analog physical processes creates unique characteristics that change how security theory is applied. Neither cyber nor physical security concepts alone can protect CPS because the crossover effects can introduce unexpected vulnerabilities. Physical attacks may allow access to critical assets resulting in damage or compromise of information being processed by the device, while cyber attacks may cause physical malfunctions resulting in real-world consequences. Therefore, security and privacy are key concerns for CPS design, development, and operation. In this chapter, we discuss how CPS security and privacy differ from that of pure cyber or physical systems and what may be done to secure these systems. Our goal is to help designers of emerging CPS to build more secure, privacy-enhanced products in the future.

Cyber-physical systems, security, privacy↗

Testbed-based Performance Evaluation of Attack Resilient Control for AGC

The modern electric power grid is a complex cyber-physical system whose reliable operation is enabled by a wide-area monitoring and control infrastructure. This infrastructure, supported by an extensive communication backbone, enables several control applications functioning at multiple time scales to ensure the grid is maintained within stable operating limits. Recent events have shown that vulnerabilities in this infrastructure may be exploited to manipulate the data being exchanged. Such a scenario could cause the associated control application to mis-operate, potentially causing system-wide instabilities. There is a growing emphasis on looking beyond traditional cybersecurity solutions to mitigate such threats. In this paper we perform a testbed-based validation of one such solution - Attack Resilient Control (ARC) - on Iowa State University's \textit{PowerCyber} testbed. ARC is a cyber-physical security solution that combines domain-specific anomaly detection and model-based mitigation to detect stealthy attacks on Automatic Generation Control (AGC). In this paper, we first describe the implementation architecture of the experiment on the testbed. Next, we demonstrate the capability of stealthy attack templates to cause forced under-frequency load shedding in a 3-area test system. We then validate the performance of ARC by measuring its ability to detect and mitigate these attacks. Our results reveal that ARC is efficient in detecting stealthy attacks and enables AGC to maintain system operating frequency close to its nominal value during an attack. Our studies also highlight the importance of testbed-based experimentation for evaluating the performance of cyber-physical security and control applications.

attack resilience↗

Testbed-based Evaluation of SIEM Tool for Cyber Kill Chain Model in Power Grid SCADA System

Development of a smarter electric grid necessitates addressing the associated cyber security challenges. Since the interdependence between the legacy grid infrastructure and advanced information technology is growing rapidly, there are numerous ways advanced, motivated, and persistent attackers can affect the SCADA based critical infrastructure. Hence, developing a security information and event management (SIEM) is crucial for securing the SCADA power system. This paper presents the application of Security Onion (SecOn) to develop the network security monitoring (NSM) and intrusion detection system (IDS) in the context of SCADA cyber physical security. Initially, we have applied a cyber kill-chain model to demonstrate the different stages of attacks and associated mechanisms. Later, the rule- based IDS (RIDS) is developed using Snort IDS, and tested in the cyber-physical SCADA environment. Furthermore, we have evaluated its performance in terms of accuracy and detection latency. Our experimental results reveal that the SecOn tool is efficient in monitoring and detecting attacks within an acceptable time frame with a high accuracy rate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Cyber and Physical Security Posture of the Electric Sector (Final Report)

Cooperative electric utilities represent an integral part of the larger electric grid and are part of the nation’s critical infrastructure. The National Rural Electric Cooperative Association (NRECA) has a unique relationship with approximately 900 cooperatively owned and operated electric utilities and engaged in a program with the Department of Energy (DOE) to promote a culture of cybersecurity and resiliency within the electric cooperative community. The Rural Cooperative Cybersecurity Capabilities (RC3) Program, funded under a Cooperative Agreement with DOE (Project DE-OE-0000807), focused on improving the cybersecurity and resiliency capabilities of small and mid-sized electric distribution cooperatives. This segment of electric utilities faces many challenges, but also embraces a culture of cooperation that presents opportunities. A customized approach is needed to reach these utilities – one that emphasizes collaboration, more focused and personalized training, use of trusted and familiar experts that can be deployed as needed, software security services that require limited in-house cybersecurity expertise, and shared resource models that enable access to more expensive cybersecurity options.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber and Physical Security Analysis of GSI and Noventum Application for IoT Communications

We present our findings of the red team exercise conducted on the device and application developed by Guardian Sensors, Inc. (GSI) and Noventum. The app is used for situational awareness and control of photovoltaics (PV) and microgrid energy systems. The assessments performed are practical case scenarios that assess the risks and vulnerabilities posed by the app through targeted activities that could be engaged by an adversary. The assessment team’s results and recommendations are provided to inform on and mitigate the identified weaknesses to improve secure user authentication, connections, and communications. The recommendations in this report are not intended to be a security panacea but will add the desired defense-in-depth layer to securing communication of such interconnected systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Automated Adversary-in-the-Loop Cyber-Physical Defense Planning

Security of cyber-physical systems (CPS) continues to pose new challenges due to the tight integration and operational complexity of the cyber and physical components. To address these challenges, this article presents a domain-aware, optimization-based approach to determine an effective defense strategy for CPS in an automated fashion—by emulating a strategic adversary in the loop that exploits system vulnerabilities, interconnection of the CPS, and the dynamics of the physical components. Our approach builds on an adversarial decision-making model based on a Markov Decision Process (MDP) that determines the optimal cyber (discrete) and physical (continuous) attack actions over a CPS attack graph. The defense planning problem is modeled as a non-zero-sum game between the adversary and defender. We use a model-free reinforcement learning method to solve the adversary’s problem as a function of the defense strategy. We then employ Bayesian optimization (BO) to find an approximate best-response for the defender to harden the network against the resulting adversary policy. This process is iterated multiple times to improve the strategy for both players. We demonstrate the effectiveness of our approach on a ransomware-inspired graph with a smart building system as the physical process. Numerical studies show that our method converges to a Nash equilibrium for various defender-specific costs of network hardening.

97 MATHEMATICS AND COMPUTING↗