Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Current multiplier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Digital control of highly augmented combat rotorcraft

Proposed concepts for the next generation of combat helicopters are to be embodied in a complex, highly maneuverable, multiroled vehicle with avionics systems. Single pilot and nap-of-the-Earth operations require handling qualities which minimize the involvement of the pilot in basic stabilization tasks. To meet these requirements will demand a full authority, high-gain, multimode, multiply-redundant, digital flight-control system. The gap between these requirements and current low-authority, low-bandwidth operational rotorcraft flight-control technology is considerable. This research aims at smoothing the transition between current technology and advanced concept requirements. The state of the art of high-bandwidth digital flight-control systems are reviewed; areas of specific concern for flight-control systems of modern combat are exposed; and the important concepts are illustrated in design and analysis of high-gain, digital systems with a detailed case study involving a current rotorcraft system. Approximate and exact methods are explained and illustrated for treating the important concerns which are unique to digital systems.

Tischler, Mark B.

Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS

A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.

Burton, William D., Jr.

Apparatus for simultaneous ion counting and current recording in mass spectrometry

Ion counting system is coupled to the last dynode of an Allen-type electron multiplier on the mass analyzer of a double focusing mass spectrometer. This leaves the anode available for an electrometer, making possible simultaneous measurements. Coupling is achieved by a ferrite core transformer and associated circuitry.

Kohl, F. J.

Topics in the optimization of millimeter-wave mixers

This report is in three parts: 1. In the first part a user-oriented computer program for the analysis of single-ended Schottky diode mixers is described. The program is used to compute the performance of a 140-220 GHz mixer and excellent agreement with measurements at 150 and 180 GHz is obtained. A sensitivity analysis indicates the importance of various diode and mount characteristics on the mixer performance. 2. The second part of this report describes a computer program for the analysis of varactor diode multipliers. The diode may operate in either the reverse biased varactor mode or with substantial forward current flow where the conversion mechanism is predominantly resistive. In addition, a design for a varactor diode doubler, tunable over an output frequency range of 150-220 GHz, is given. The doubler has 10-20% conversion efficiency with an instantaneous bandwidth of 3%. 3. The third section of this report contains a description and analysis of i new H-plane rectangular waveguide transformer. The transformer can be made luckily and easily in split-block waveguide using a standard slitting saw. It is particularly suited for use in the millimeter-wave band, replacing conventional electroformed stepped transformers. A theoretical analysis of the transformer is given, and good agreement is obtained with measurements made at X-band. Design curves are included for transitions which have a VSWR <1.2 over a full waveguide band when the impedance ratio is as high as 4 to 1.

Millimeter-wave

Effect of self-generated magnetic fields on x-ray emission in Kr-filled targets at the National Ignition Facility

We examine the effects of self-generated magnetic fields in a Kr gas pipe x-ray source platform. X-ray emission from Kr plasma is dependent on the plasma conditions, as the ionization state is largely a function of temperature. Magnetic fields are known to limit heat conduction, which increases temperature. We show that the emission in simulations of the gas pipe x-ray source is dependent on how self-generated magnetic fields are modeled. The inclusion of self-generated magnetic fields in simulations more accurately captures the emission of lower energy x-ray emission (L-shell), bringing results closer to experiments. The modeled x-ray emission and self-generated magnetic fields are shown to be particularly sensitive to the inclusion of the Nernst effect in simulations. Severely limiting the Nernst effect leads to a hotter Kr plasma, which can account for the discrepancy seen in earlier studies. By modifying the Nernst effect multiplier, we can achieve better experimental agreement in x-ray emission from gas pipes; the value of the multiplier that leads to the best agreement is dependent on the laser power of the drive. Currently, the suppression factor of the Nernst effect needed for high power drives (PL>200 TW) is more restrictive than what is currently put forward by non-local models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

A multiple access communication network based on adaptive arrays

A single frequency communication system is considered consisting of K possibly moving users distributed in space simultaneously communicating with a central station equipped with a computationally adapted array of n = or K antennas. Such a configuration could result if K spacecraft were to be simultaneously tracked by a single DSN complex consisting of an n antennas array. The array employs K sets of n weights to segregate the signals received from the K users. The weights are determined by direct computation based on known position information of the K users. Currently known techniques require (for n = K) about (4/3)K to the 4th power computer operations (multiply and add) to perform such computations. A technique that accomplishes this same goal in 8 K to the 3rd power operations, yielding a reduction by a factor K/6, was developed.

Zohar, S.

Spacecraft-borne long life cryogenic refrigeration: Status and trends

The status of cryogenic refrigerator development intended for, or possibly applicable to, long life spacecraft-borne application is reviewed. Based on these efforts, the general development trends are identified. Using currently projected technology needs, the various trends are compared and evaluated. The linear drive, non-contacting bearing Stirling cycle refrigerator concept appears to be the best current approach that will meet the technology projection requirements for spacecraft-borne cryogenic refrigerators. However, a multiply redundant set of lightweight, moderate life, moderate reliability Stirling cycle cryogenic refrigerators using high-speed linear drive and sliding contact bearings may possibly suffice.

Johnson, A. L.

Design of a Wideband 6-Anode Frequency Tripler at 300 GHz with Optimum Balance

We report on the design methodology of a fix-tuned split-block waveguide balanced frequency tripler working nominally at 300 GHz. It features six GaAs Schottky planar diodes in a balanced configuration. The circuit will be fabricated with JPL membrane technology in order to minimize dielectric loading and insure an accurate and uniform thickness of the substrate. The multiplier power handling is limited by the breakdown voltage of the diodes that depends on the doping level of the active layer. With six diodes, the current choice for the doping level leads to medium power handling capabilities of about 50 mW. Increasing the number of diodes to eight would be an option but would lead to increased difficulties in design and fabrication.

Schottky diode multipliers

Four-Quadrant Analog Multipliers Using G4-FETs

Theoretical analysis and some experiments have shown that the silicon-on-insulator (SOI) 4-gate transistors known as G4-FETs can be used as building blocks of four-quadrant analog voltage multiplier circuits. Whereas a typical prior analog voltage multiplier contains between six and 10 transistors, it is possible to construct a superior voltage multiplier using only four G4-FETs. A G4-FET is a combination of a junction field-effect transistor (JFET) and a metal oxide/semiconductor field-effect transistor (MOSFET). It can be regarded as a single transistor having four gates, which are parts of a structure that affords high functionality by enabling the utilization of independently biased multiple inputs. The structure of a G4-FET of the type of interest here (see Figure 1) is that of a partially-depleted SOI MOSFET with two independent body contacts, one on each side of the channel. The drain current comprises of majority charge carriers flowing from one body contact to the other that is, what would otherwise be the side body contacts of the SOI MOSFET are used here as the end contacts [the drain (D) and the source (S)] of the G4-FET. What would otherwise be the source and drain of the SOI MOSFET serve, in the G4-FET, as two junction-based extra gates (JG1 and JG2), which are used to squeeze the channel via reverse-biased junctions as in a JFET. The G4-FET also includes a polysilicon top gate (G1), which plays the same role as does the gate in an accumulation-mode MOSFET. The substrate emulates a fourth MOS gate (G2). By making proper choices of G4-FET device parameters in conjunction with bias voltages and currents, one can design a circuit in which two input gate voltages (Vin1,Vin2) control the conduction characteristics of G4-FETs such that the output voltage (Vout) closely approximates a value proportional to the product of the input voltages. Figure 2 depicts two such analog multiplier circuits. In each circuit, there is the following: The input and output voltages are differential, The multiplier core consists of four G4- FETs (M1 through M4) biased by a constant current sink (Ibias), and The G4-FETs in two pairs are loaded by two identical resistors (RL), which convert a differential output current to a differential output voltage. The difference between the two circuits stems from their input and bias configurations. In each case, provided that the input voltages remain within their design ranges as determined by considerations of bias, saturation, and cutoff, then the output voltage is nominally given by Vout = kVin1Vin2, where k is a constant gain factor that depends on the design parameters and is different for the two circuits. In experimental versions of these circuits constructed using discrete G4- FETs and resistors, multiplication of voltages in all four quadrants (that is, in all four combinations of input polarities) was demonstrated, and deviations of the output voltages from linear dependence on the input voltages were found to amount to no more than a few percent. It is anticipated that in fully integrated versions of these circuits, the deviations from linearity will be made considerably smaller through better matching of devices.

Mojarradi, Mohammad

Progress on single barrier varactors for submillimeter wave power generation

Theoretical work on Single Barrier Varactor (SBV) diodes, indicate that the efficiency for a multiplier has a maximum for a considerably smaller capacitance variation than previously thought. The theoretical calculations are performed, both with a simple theoretical model and a complete computer simulation using the method of harmonic balance. Modeling of the SBV is carried out in two steps. First, the semiconductor transport equations are solved simultaneously using a finite difference scheme in one dimension. Secondly, the calculated I-V, and C-V characteristics are input to a multiplier simulator which calculates the optimum impedances, and output powers at the frequencies of interest. Multiple barrier varactors can also be modeled in this way. Several examples on how to design the semiconductor layers to obtain certain characteristics are given. The calculated conversion efficiencies of the modeled structures, in a multiplier circuit, are also presented. Computer simulations for a case study of a 750 GHz multiplier show that InAs diodes perform favorably compared to GaAs diodes. InAs and InGaAs SBV diodes have been fabricated and their current vs. voltage characteristics are presented. In the InAs diode, was the large bandgap semiconductor AlSb used as barrier. The InGaAs diode was grown lattice matched to an InP substrate with InAlAs as a barrier material. The current density is greatly reduced for these two material combinations, compared to that of GaAs/AlGaAs SBV diodes. GaAs based diodes can be biased to higher voltages than InAs diodes.

Nilsen, Svein M.

What We've Learned from Approximately 12 Years of MISR Aerosol Observations

The NASA Earth Observing System's Multi-angle Imaging SpectroRadiometer (MISR) has been imaging the planet about once per week for nearly 12 years. These data contain a wealth of information about the current state, as well as the variability of Earth's surface and atmosphere. For airborne particles specifically, horizontal distributions of aerosol optical depth, aerosol type, and near-source aerosol plume height are now routinely derived. The results are being applied to a wide range of problems, from constraining aerosol direct radiative forcing of climate and assessing its seasonal and secular trends, to material transports of smoke and dust, to mapping volcanic ash plumes and near-surface aerosol pollution. The value of these data is multiplied many times by combining it with data from other sources, and using the aggregate to constrain models. This talk will summarize the latest developments, and will also discuss current work aimed at making further advancements in these areas.

Kahn, Ralph

Analysis of magnetic fields using variational principles and CELAS2 elements

Prospective techniques for analyzing magnetic fields using NASTRAN are reviewed. A variational principle utilizing a vector potential function is presented which has as its Euler equations, the required field equations and boundary conditions for static magnetic fields including current sources. The need for an addition to this variational principle of a constraint condition is discussed. Some results using the Lagrange multiplier method to apply the constraint and CELAS2 elements to simulate the matrices are given. Practical considerations of using large numbers of CELAS2 elements are discussed.

Frye, J. W.

Measurement of the Neutron Magnetic Form Factor at Large Momentum Transfer Using the Super-Bigbite Apparatus in Jefferson Lab Hall-A

The nucleon elastic electromagnetic form factors help us study the electromagnetic structure of the nucleon, benchmark theoretical models, and improve our understanding of non-perturbative quantum chromodynamics and confinement. The Nobel Prize-winning electron-nucleon scattering experiments by Robert Hofstadter and collaborators in the 1950s at Stanford High Energy Physics Lab were the first nucleon form factor measurements performed using leptonic probes. The Super Bigbite Spectrometer (SBS) program at Hall-A of Jefferson Lab represents the latest efforts to measure nucleon form factors. This ambitious program aims to significantly extend the current data set in terms of square momentum transfer (Q2) with high precision. The advent of novel detector technologies, like Gas Electron Multipliers (GEM), which provide excellent position resolution (< 100 ?m) while withstanding high background particle rates (several hundred MHz/cm2) over a large active area, has paved the way for open-geometry, moderate solid angle spectrometers, which are central to all form factor experiments in the SBS program. The first experimental run group in SBS ran successfully between September 2021 and February 2022, collecting data for the measurement of the magnetic form factor of the neutron Gn M at five squared momentum-transfer values: 3.0, 4.5, 7.5, 9.8, and 13.5 (GeV /c)2. This extends the existing high-precision data for Gn M by about a factor of four. The ratio technique was used, which involved the simultaneous measurement of exclusive quasielastic scattering of D(e,e?n)p and D(e,e?p)n from a deuterium target. Pre-preliminary results for D(e,e?n)p and D(e,e?p)n quasi-elastic ratio, and the neutron magnetic form factor Gn M , for Q2 points 3.0, 9.8, and 13.5 (GeV /c)2 are presented.

Mudiyanselage, Anuruddha Rathnayake

Reliability of Cascaded THz Frequency Chains with Planar GaAs Circuits

Planar GaAs Schottky diodes will be utilized for all of the LO chains on the HIPI instrument for the Herschel Space Observatory. A better understanding of device degradation mechanisms is desirable in order to specify environmental and operational conditions that do not reduce device life times. Failures and degradation associated with ESD (Electrostatic Discharge), high temperatures, DC currents and RF induced current and heating have been investigated. The goal is to establish a procedure to obtain the safe operating range for a given frequency multiplier.

reliability on Schottky diode multipliers

Strategies to Improve the Accuracy of Mars-GRAM Sensitivity Studies at Large Optical Depths

The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM s perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). It has been discovered during the Mars Science Laboratory (MSL) site selection process that Mars-GRAM when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3 is less than realistic. A comparison study between Mars atmospheric density estimates from Mars- GRAM and measurements by Mars Global Surveyor (MGS) has been undertaken for locations of varying latitudes, Ls, and LTST on Mars. The preliminary results from this study have validated the Thermal Emission Spectrometer (TES) limb data. From the surface to 80 km altitude, Mars- GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear=0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. Unrealistic energy absorption by uniform atmospheric dust leads to an unrealistic thermal energy balance on the polar caps. The outcome is an inaccurate cycle of condensation/sublimation of the polar caps and, as a consequence, an inaccurate cycle of total atmospheric mass and global-average surface pressure. Under an assumption of unchanged temperature profile and hydrostatic equilibrium, a given percentage change in surface pressure would produce a corresponding percentage change in density at all altitudes. Consequently, the final result of a change in surface pressure is an imprecise atmospheric density at all altitudes. To solve this pressure-density problem, a density factor value was determined for tau=.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear=0 with MapYears 1 and 2 MGCM output at comparable dust loading. Currently, these density factors are fixed values for all latitudes and Ls. Results will be presented of the work underway to derive better multipliers by including possible variation with latitude and/or Ls. This is achieved by comparison of Mars-GRAM MapYear=0 output with TES limb data. The addition of these density factors to Mars-GRAM will improve the results of the sensitivity studies done for large optical depths. Answers may also be provided to the issues raised in a recent study by Desai(2008). Desai has shown that the actual landing sites of Mars Pathfinder, the Mars Exploration Rovers and the Phoenix Mars Lander have been further downrange than predicted by models prior to landing. Desai s reconstruction of their entries into the Martian atmosphere showed that the models consistently predicted higher densities than those found upon EDL. The solution of this problem would be important to the Mars Program since future exploration of Mars by landers and rovers will require more accurate landing capabilities, especially for the proposed Mars Sample Return mission.

Justh, Hilary L.

Updating Mars-GRAM to Increase the Accuracy of Sensitivity Studies at Large Optical Depths

The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM s perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). During the Mars Science Laboratory (MSL) site selection process, it was discovered that Mars-GRAM, when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3, is less than realistic. From the surface to 80 km altitude, Mars-GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear set to 0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. This has resulted in an imprecise atmospheric density at all altitudes. As a preliminary fix to this pressure-density problem, density factor values were determined for tau=0.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear 0 with Thermal Emission Spectrometer (TES) observations for MapYears 1 and 2 at comparable dust loading. Currently, these density factors are fixed values for all latitudes and Ls. Results will be presented from work being done to derive better multipliers by including variation with latitude and/or Ls by comparison of MapYear 0 output directly against TES limb data. The addition of these more precise density factors to Mars-GRAM 2005 Release 1.4 will improve the results of the sensitivity studies done for large optical depths.

Justh, Hiliary L.

Effect of cooling on the efficiency of Schottky varactor frequency multipliers at millimeter waves

The efficiency of the Schottky diode multiplier can be increased by cooling the diode to 77 K. The main reason for better efficiency is the increased mobility of the free carriers. Because of that the series resistance decreases and a few dB higher efficiency can be expected at low input power levels. At high output frequencies and at high power levels, the current saturation decreases the efficiency of the multiplication. When the diode is cooled the maximum current of the diode increases and much more output power can be expected. There are also slight changes in the I-V characteristic and in the diode junction capacitance, but they have a negligible effect on the efficiency of the multiplier.

Louhi, Jyrki