Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Materials Data on CsY(WO4)2 by Materials Project

CsY(WO4)2 crystallizes in the monoclinic C2/c space group. The structure is three-dimensional. Cs1+ is bonded in a 12-coordinate geometry to ten O2- atoms. There are a spread of Cs–O bond distances ranging from 2.97–3.09 Å. Y3+ is bonded in a 6-coordinate geometry to six O2- atoms. There are a spread of Y–O bond distances ranging from 2.30–2.36 Å. W6+ is bonded to six O2- atoms to form a mixture of edge and corner-sharing WO6 octahedra. The corner-sharing octahedral tilt angles are 40°. There are a spread of W–O bond distances ranging from 1.84–2.16 Å. There are four inequivalent O2- sites. In the first O2- site, O2- is bonded in a 4-coordinate geometry to two equivalent Cs1+ and two equivalent W6+ atoms. In the second O2- site, O2- is bonded in a 2-coordinate geometry to one Cs1+, one Y3+, and one W6+ atom. In the third O2- site, O2- is bonded in a 3-coordinate geometry to one Cs1+, one Y3+, and two equivalent W6+ atoms. In the fourth O2- site, O2- is bonded in a 2-coordinate geometry to one Cs1+, one Y3+, and one W6+ atom.

36 MATERIALS SCIENCE↗

Materials Data on CsY(BH4)4 by Materials Project

CsY(BH4)4 crystallizes in the tetragonal I4_1/a space group. The structure is three-dimensional. Cs1+ is bonded in a 8-coordinate geometry to eight equivalent H+0.50+ atoms. There are four shorter (3.19 Å) and four longer (3.36 Å) Cs–H bond lengths. Y3+ is bonded in a 12-coordinate geometry to twelve H+0.50+ atoms. There are eight shorter (2.35 Å) and four longer (2.36 Å) Y–H bond lengths. B3- is bonded in a tetrahedral geometry to four H+0.50+ atoms. There is one shorter (1.20 Å) and three longer (1.24 Å) B–H bond length. There are four inequivalent H+0.50+ sites. In the first H+0.50+ site, H+0.50+ is bonded in a distorted single-bond geometry to one Y3+ and one B3- atom. In the second H+0.50+ site, H+0.50+ is bonded in a single-bond geometry to one Y3+ and one B3- atom. In the third H+0.50+ site, H+0.50+ is bonded in a single-bond geometry to two equivalent Cs1+ and one B3- atom. In the fourth H+0.50+ site, H+0.50+ is bonded in a single-bond geometry to one Y3+ and one B3- atom.

36 MATERIALS SCIENCE↗

Report on Coastal Structure Integrated Wave Energy Converters (CSI-WECs)

This report investigates a largely underexplored, and underexploited, application for wave energy: coastal structure integrated wave energy converters (CSI-WECs). These WEC types have significant potential to rapidly advance the wave energy industry while addressing the challenges of coastal community resiliency and marine energy integration and application, and the urgent need for increased coastal protection. To further support the value proposition investigation of this work, three wave energy developers agreed to conduct an energy production analysis of their technology for the four sites identified. Additionally, a geographic information system-based tool was developed that supports efficient and comprehensive site assessment for optimal and high-value deployments.

16 TIDAL AND WAVE POWER↗

Gas Chromatography-Tandem Mass Spectrometry of Lignin Pyrolyzates with Dopant-Assisted Atmospheric Pressure Chemical Ionization and Molecular Structure Search with CSI:FingerID

Dopant-assisted atmospheric pressure chemical ionization (dAPCI) is a soft ionization method rarely used for gas chromatography-mass spectrometry (GC-MS). The current study combines GC-dAPCI with tandem mass spectrometry (MS/MS) for analysis of a complex mixture such as lignin pyrolysis analysis. To identify the structures of volatile lignin pyrolysis products, collision-induced dissociation (CID) MS/MS using a quadrupole time-of-flight mass spectrometer (QTOFMS) and pseudo MS/MS through in-source collision-induced dissociation (ISCID) using a single stage TOFMS are utilized. To overcome the lack of MS/MS database, Compound Structure Identification (CSI):FingerID is used to interpret CID spectra and predict best matched structures from PubChem library. With this approach, a total of 59 compounds were positively identified in comparison to only 22 in NIST database search of GC-EI-MS dataset. This study demonstrates the effectiveness of GC-dAPCI-MS/MS to overcome the limitations of traditional GC-EI-MS analysis when EI-MS database is not sufficient. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and test of the Mu2e undoped CsI+SiPM crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating neutrino-less conversion of a negative muoninto an electron in the field of an aluminum nucleus. The calorimeter plays an important role in providing a fast trigger filter,excellent particle identification and a seeding for track reconstruction. Its requirements are to provide an energy (timing) resolutionbetter than 10% (0.5 ns) and a position resolution below 1 cm, for 100 MeV electrons. The calorimeter consists of two disks, eachone made of 674 un-doped CsI crystals readout by two large area arrays of 23 UV-extended SiPMs of 66 mm2dimensions.A large scale prototype (Module-0) has been constructed and tested with an electron beam in the energy range between 60 and 120MeV at the BTF of Frascati National Laboratories. Results demonstrated that this calorimeter satisfies the Mu2e requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct-reaction studies by particle-{gamma} coincidence spectroscopy using Csi-Hpge and Si-Hpge arrays

Particle-{gamma} and particle-{gamma}-{gamma} coincidence spectroscopy has several advantages in the study of direct reactions (particularly in inverse kinematics) since it can generally allow determination of: decay paths; high-precision level energies; multipolarities of transitions; and cross sections. Techniques for studying direct reactions by particle-{gamma} coincidence spectroscopy are presented for two cases: (1) heavy-ion reactions with CsI-HPGe, and (2) light-ion reactions with Si-HPGe. Future direct-reaction studies with radioactive ion beams (RIBs) will mostly involve low beam intensities and inverse kinematics (i.e., A{sub beam}>A{sub target}), which eliminates the traditional use of magnetic spectrometers. Particle-{gamma} coincidence spectroscopy currently provides the most viable method to study direct reactions with nuclei of any level density. In the present study, the capabilities and limitations of the technique are explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Channeling in direct dark matter detection III: channeling fraction in CsI crystals

The channeling of the ion recoiling after a collision with a WIMP changes the ionization signal in direct detection experiments, producing a larger signal scintillation or ionization than otherwise expected. We give estimates of the fraction of channeled recoiling ions in CsI crystals using analytic models produced since the 1960's and 70's to describe channeling and blocking effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e undoped CsI crystal calorimeter

We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE STELLAR MASS–HALO MASS RELATION FOR LOW-MASS X-RAY GROUPS AT 0.5< z< 1 IN THE CDFS WITH CSI

Since z∼1, the stellar mass density locked in low-mass groups and clusters has grown by a factor of ∼8. Here, we make the first statistical measurements of the stellar mass content of low-mass X-ray groups at 0.5<z<1, enabling the calibration of stellar-to-halo mass scales for wide-field optical and infrared surveys. Groups are selected from combined Chandra and XMM-Newton X-ray observations in the Chandra Deep Field South. These ultra-deep observations allow us to identify bona fide low-mass groups at high redshift and enable measurements of their total halo masses. We compute aggregate stellar masses for these halos using galaxies from the Carnegie-Spitzer-IMACS (CSI) spectroscopic redshift survey. Stars comprise ∼3%–4% of the total mass of group halos with masses 10{sup 12.8}<M{sub 200}/M{sub ⊙}<10{sup 13.5} (about the mass of Fornax and one-fiftieth the mass of Virgo). Complementing our sample with higher mass halos at these redshifts, we find that the stellar-to-halo mass ratio decreases toward higher halo masses, consistent with other work in the local and high redshift universe. The observed scatter about the stellar–halo mass relation is σ∼0.25 dex, which is relatively small and suggests that total group stellar mass can serve as a rough proxy for halo mass. We find no evidence for any significant evolution in the stellar–halo mass relation since z≲1. Quantifying the stellar content in groups since this epoch is critical given that hierarchical assembly leads to such halos growing in number density and hosting increasing shares of quiescent galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of {nu}{sub e}-electron scattering cross section with a CsI(Tl) scintillating crystal array at the Kuo-Sheng nuclear power reactor

The {nu}{sub e}-e{sup -} elastic scattering cross section was measured with a CsI(Tl) scintillating crystal array having a total mass of 187 kg. The detector was exposed to an average reactor {nu}{sub e} flux of 6.4x10{sup 12} cm{sup -2} s{sup -1} at the Kuo-Sheng Nuclear Power Station. The experimental design, conceptual merits, detector hardware, data analysis, and background understanding of the experiment are presented. Using 29882/7369 kg-days of Reactor ON/OFF data, the standard model (SM) electroweak interaction was probed at the squared 4-momentum transfer range of Q{sup 2{approx}}3x10{sup -6} GeV{sup 2}. The ratio of experimental to SM cross sections of {xi}=[1.08{+-}0.21(stat){+-}0.16(sys)] was measured. Constraints on the electroweak parameters (g{sub V},g{sub A}) were placed, corresponding to a weak mixing angle measurement of sin{sup 2{theta}}{sub W}=0.251{+-}0.031(stat){+-}0.024(sys). Destructive interference in the SM {nu}{sub e}-e process was verified. Bounds on anomalous neutrino electromagnetic properties were placed: neutrino magnetic moment at {mu}{sub {nu}{sub e}}<2.2x10{sup -10} {mu}{sub B} and the neutrino charge radius at -2.1x10{sup -32} cm{sup 2}<<r{sub {nu}}{sub e}{sup 2}><3.3x10{sup -32} cm{sup 2}, both at 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

E-Beam Electron Mobility Study on CZT and CsI

There is much interest in developing new scintillator detectors for radiation detection and radiographic imaging applications. The knowledge of the electron mobility ({mu}) is important in the basic understanding of charge transport and in the selection and optimization of many inorganic scintillator materials such as thallium-doped cesium iodide, CsI(Tl). Performance measures are used to model various scintillator responses in an effort to predict the effect of doping concentrations. Performance models will help in the new scintillator design process. Initial tests are done with cadmium zinc telluride detectors to establish measurement techniques and baselines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-340: Use of Intensity Modulated Proton Therapy (IMPT) for Reducing the Dose to Cochlea in Craniospinal Irradiation (CSI) of Pediatric Patients

Purpose: To evaluate use of intensity modulated proton therapy (IMPT) and number of beams for sparing cochlea in treatment of whole brain for pediatric medulloblastoma patients. Methods: In our institution, craniospinal irradiation patients are treated in supine position on our proton gantries using pencil beam scanning with each beam uniformly covering the target volume (SFUD). Each treatment plan consists of two opposed lateral whole brain fields and one or two spinal fields. For sparing the cochlea for the whole brain treatment, we created three different plans using IMPT for five pediatric patients. The first plan consisted of two lateral fields, the second two lateral fields and a superior-inferior field, and the third two lateral fields and two superior oblique fields. Optimization was performed with heavy weights applied to the eye, lens and cochlea while maintaining a dose prescription of 36 Gy to the whole brain. Results: IMPT plans reduce the dose to the cochlea. Increasing the number of treatment fields was found to lower the average dose to the cochlea: 15.0, 14.5 and 12.5 Gy for the two-field, three-field, and four-field plans respectively. The D95 for the two-field plan was 98.2%, compared to 100.0% for both the three-field and four-field plan. Coverage in the mid-brain was noticeably better in the three- and four-field plans, with more dose conformality surrounding the cochlea. Conclusion: IMPT plans for CSI and the whole brain irradiations are capable of sparing cochlea and reduce the dose considerably without compromising treating brain tissues. The reduction in average dose increases with three and four field plans as compared to traditional two lateral beam plans.

60 APPLIED LIFE SCIENCES↗

First operation of undoped CsI directly coupled with SiPMs at 77 K

Abstract The light yield of a small undoped cesium iodide (CsI) crystal directly coupled with two silicon photomultipliers (SiPMs) at about 77 Kelvin was measured to be $$43.0 \pm 1.1$$ 43.0 ± 1.1 photoelectrons (PE) per keV electron-equivalent (keV $$_\text {ee}$$ ee ) using X and $$\gamma $$ γ -ray peaks from an $$^{241}$$ 241 Am radioactive source from 18 to 60 keV. The high light yield together with some other technical advantages illustrate the great potential of this novel combination for neutrino and low-mass dark matter detection, particularly at accelerator-based neutrino sources, where random background can be highly suppressed by requiring coincident triggers between SiPMs and beam pulse timing signals. Some potential drawbacks of using cryogenic SiPMs instead of photomultiplier tubes (PMTs) were identified, such as worse energy resolution and optical cross-talks between SiPMs. Their influence to rare-event detection was discussed and possible solutions were provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils

The data release from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in 'D. Akimov et al 2022 JINST 17 P10034.' We share the data in the form of raw ADC waveforms, provide benchmark subselections and event reconstruction scripts to enhance the transparency and reproducibility of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AmeriFlux US-WT2 Stratford CSI

This is the AmeriFlux version of the carbon flux data for the site US-WT2 Stratford CSI. Site Description - Winter annual forage production system with grazing

Bednarz, Craig [West Texas A&M University]↗

Measurement of the energy and time resolution of a undoped CsI + MPPC array for the Mu2e experiment

This paper describes the measurements of energy and time response and resolution of a 3 x 3 array made of undoped CsI crystals coupled to large area Hamamatsu Multi Pixel Photon Counters. The measurements have been performed using the electron beam of the Beam Test Facility in Frascati (Rome, Italy) in the energy range 80-120 MeV. The measured energy resolution, estimated with the FWHM, at 100 MeV is 16.4%. This resolution is dominated by the energy leakage due to the small dimensions of the prototype. The time is reconstructed by fitting the leading edge of the digitized signals and applying a digital constant fraction discrimination technique. A time resolution of about 110 ps at 100 MeV is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗