Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.

Roessler, K.↗

Small Business Innovations (Cryostat)

General Pneumatics Corporation, Scottsdale, AZ, developed an anti- clogging cryostat that liquifies gases by expansion for high pressure through a nozzle to produce cryorefrigeration based on their Kennedy Space Center Small Business Innovation Research (SBIR) work to develop a Joule-Thomson (JT) expansion valve that is less susceptible to clogging by particles or condensed contaminants in the flow than a non-contaminating compressor in a closed cycle Linde-Hampson cryocooler used to generate cryogenic cooling for infrared sensors, super conductors, supercooled electronics and cryosurgery.

Source record↗

Simplified Methodology to Estimate the Maximum Liquid Helium (LHe) Cryostat Pressure from a Vacuum Jacket Failure

The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared astronomical observation experiments. These experiments carry sensors cooled to liquid helium temperatures. The liquid helium supply is contained in large (i.e., 10 liters or more) vacuum-insulated dewars. Should the dewar vacuum insulation fail, the inrushing air will condense and freeze on the dewar wall, resulting in a large heat flux on the dewar's contents. The heat flux results in a rise in pressure and the actuation of the dewar pressure relief system. A previous NASA Engineering and Safety Center (NESC) assessment provided recommendations for the wall heat flux that would be expected from a loss of vacuum and detailed an appropriate method to use in calculating the maximum pressure that would occur in a loss of vacuum event. This method involved building a detailed supercritical helium compressible flow thermal/fluid model of the vent stack and exercising the model over the appropriate range of parameters. The experimenters designing science instruments for SOFIA are not experts in compressible supercritical flows and do not generally have access to the thermal/fluid modeling packages that are required to build detailed models of the vent stacks. Therefore, the SOFIA Program engaged the NESC to develop a simplified methodology to estimate the maximum pressure in a liquid helium dewar after the loss of vacuum insulation. The method would allow the university-based science instrument development teams to conservatively determine the cryostat's vent neck sizing during preliminary design of new SOFIA Science Instruments. This report details the development of the simplified method, the method itself, and the limits of its applicability. The simplified methodology provides an estimate of the dewar pressure after a loss of vacuum insulation that can be used for the initial design of the liquid helium dewar vent stacks. However, since it is not an exact tool, final verification of the dewar pressure vessel design requires a complete, detailed real fluid compressible flow model of the vent stack. The wall heat flux resulting from a loss of vacuum insulation increases the dewar pressure, which actuates the pressure relief mechanism and results in high-speed flow through the dewar vent stack. At high pressures, the flow can be choked at the vent stack inlet, at the exit, or at an intermediate transition or restriction. During previous SOFIA analyses, it was observed that there was generally a readily identifiable section of the vent stack that would limit the flow – e.g., a small diameter entrance or an orifice. It was also found that when the supercritical helium was approximated as an ideal gas at the dewar condition, the calculated mass flow rate based on choking at the limiting entrance or transition was less than the mass flow rate calculated using the detailed real fluid model2. Using this lower mass flow rate would yield a conservative prediction of the dewar’s wall heat flux capability. The simplified method of the current work was developed by building on this observation.

Ungar, Eugene K.↗

Development of an 400 L Integrated Refrigeration and Storage Cryostat for LNG/LCH4 Research

Research engineers from the Cryogenics Test Laboratory at NASA Kennedy Space Center in Florida have developed a 400 liter Integrated Refrigeration and Storage (IRAS) cryostat to explore advanced techniques for storage, conditioning, and transfer of liquefied natural gas and/or pure methane. A vertical-cylindrical configuration, the vacuum-jacketed apparatus houses a G-M cryocooler to control the state of the fluid, and sample tubes with corresponding temperature sensors fixed at various elevations to allow for sampling of the liquid. Two additional ports were also included for future instrumentation and/or mechanical feed-throughs. A primary goal of this test apparatus will be to study the effect of IRAS on the behavior of LNG during storage; most notably weathering and stratification of the bulk liquid over time. Additionally, in-situ liquefaction of natural gas can be performed, along with zero boil-off control, liquid densification, and slush production.

Swanger, Adam M.↗

Thermal Vacuum Testing of the Cryostat Heat Removal System for COSI SMEX

The Cryostat Heat Removal System (CHRS) of the Compton Spectrometer and Imager (COSI) consists of cryocooler, three transport aluminum ammonia Constant Conductance Heat Pipes (CCHP), three radiators with CCHP spreaders and Cryocooler Control Electronics (CCE) attached to a separate radiator. A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the integrated COSI CHRS in the flat configuration. This presentation summarizes the measured COSI CHRS performance along with lessons learned.

Pipes↗

Cold Test Results of Pre-Production PIP-II SSR2 Cavities with High-Power Couplers in the Fermilab Spoke Test Cryostat

As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qualification at Fermilab, complete with tuner and high-power coupler assemblies. This paper provides an overview of the ongoing efforts dedicated to high-power testing of jacketed SSR2 cavities in the Spoke Test Cryostat (STC) at Fermilab. Performance parameters obtained from these tests are presented, offering valuable insights into the cavities operational characteristics and readiness for integration into the PIP-II cryomodule.

43 PARTICLE ACCELERATORS↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Design Improvements in Liquid Argon Purification Techniques in DUNE Cold Electronics Test Cryostat (Iceberg)

A proposed design improvement for the removal of electronegative impurities from liquid argon for the purpose of neutrino detector research is described. The design will utilize a commercially available submersible pump to circulate liquid argon through an external filter containing molecular sieve and activated copper media, removing water and oxygen, respectively. The existing state-of-the-art filter design provides a throughput of 0.5 L/min, while the capacity of the submersible pump design is at least 4 L/min, though could be even higher depending on total losses within the filtration piping assembly. An additional benefit of the new design will be the ability to regenerate the filter media in situ without stopping the experimental testing. The following work will describe the design, operation, and expected performance using CFD analysis.

Schwartz, F.↗