At least 73 records · Page 4

Germanium JFET for Cryogenic Readout Electronics

The n-channel Germanium junction field effect transistor (Ge-JFET) was designed and fabricated for cryogenic applications. The Ge-JFET exhibits superior noise performance at liquid nitrogen temperature (77 K). From the device current voltage characteristics of n-channel JFETs, it is seen that transconductance increases monotonically with the lowering of temperature to 4.2 K (liquid helium temperature).

Das, N. C.↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗

Assessment of Cryogenic Analog Electronics for Lunar Environment

Assessment of Analog Electronics for Lunar Power Hibernation Non-nuclear robotic spacecraft on the Moon may not reliably operate past the first lunar day due to the subsequent long lunar night with an extreme low temperature range of 50K-100K. To address this concern, the NASA Glenn Research Center is developing a lunar power hibernation protocol that could enable spacecraft to passively survive the lunar night without any additional heating source and then reactivate at lunar dawn. Low cost lunar robotic missions could extend their mission lifetime from a single lunar cycle to potentially many months, thus greatly extending science data gathering and return on investment for commercial missions. This approach centers on evidence that lithium-ion battery cells can recover to full operation after being subjected to cryogenic temperatures. Exploiting this battery capability requires that all spacecraft electronics, including power system and avionics, passively tolerate the extreme cold without degradation. Key elements in the power system will also need to be capable of actively operating in the extreme cold to perform the functions required to restore the system to full operation after solar power returns at lunar dawn. This presentation provides an assessment of extreme-cold tolerance and operational capability of analog electronics where choices in semiconductor material, device type, and circuit fabrication technology has a dramatic impact on circuit behavior and reliability at low temperatures.

Lunar↗

2.5 Å-resolution structure of human CDK-activating kinase bound to the clinical inhibitor ICEC0942

The human CDK-activating kinase (CAK), composed of CDK7, cyclin H, and MAT1, is involved in the control of transcription initiation and the cell cycle. Because of these activities, it has been identified as a promising target for cancer chemotherapy. A number of CDK7 inhibitors have entered clinical trials, among them ICEC0942 (also known as CT7001). Structural information can aid in improving the affinity and specificity of such drugs or drug candidates, reducing side effects in patients. Here, we have determined the structure of the human CAK in complex with ICEC0942 at 2.5 Å-resolution using cryogenic electron microscopy. Our structure reveals conformational differences of ICEC0942 compared with previous X-ray crystal structures of the CDK2-bound complex, and highlights the critical ability of cryogenic electron microscopy to resolve structures of drug-bound protein complexes without the need to crystalize the protein target.

59 BASIC BIOLOGICAL SCIENCES↗

An in situ ambient and cryogenic transmission electron microscopy study of the effects of temperature on dislocation behavior in CrCoNi-based high-entropy alloys with low stacking-fault energy

Temperature is known to affect deformation mechanisms in metallic alloys. As temperature decreases, the stacking-fault energy in many face-centered cubic (fcc) alloys decreases, resulting in a change of deformation mode from dislocation slip to deformation twinning. Such an impact of temperature can be more complex in compositionally heterogeneous microstructures that exhibit, for example, local concentration fluctuation such as that in multi-principal element alloys. In this work, we compare the dislocation behavior and mechanical properties of a fcc Cr 20 Mn 10 Fe 30 Co 30 Ni 10 high-entropy alloy at ambient and liquid-nitrogen temperatures. We find that a network of stacking faults is formed by uniformly extended dislocations at ambient temperatures with low stacking-fault energy, whereas at lower temperatures, uneven dissociation of dislocations becomes significant, which results in severe dislocation pile-ups together with their pronounced entanglement. Our findings indicate that as the stacking-fault energy decreases with decreasing temperature, the heterogeneity of the distribution of elements becomes more dominant in tuning the local variation of lattice resistance. As a result, the change in dislocation behavior at low temperatures strongly affects microstructural evolution and consequently leads to significantly more pronounced work hardening.

36 MATERIALS SCIENCE↗

Cryo-EM Visualization of Intermolecular π-Electron Interactions within π-Conjugated Peptidic Supramolecular Polymers

The self-assembly of “π-peptides” – molecules with π-electron cores substituted with two or more oligopeptide chains – brings organic electronic function into biologically relevant nanomaterials. π-Peptides assemble into fibrillar nanomaterials as driven by enthalpic peptide-based hydrogen bonding networks and pi-core-based quadrupolar interactions. A large body of spectroscopic, morphological and computational studies informs on the nature of the self-assembly process and the resulting nanostructures, but detailed structural information has remained elusive. Here, inspired by the recent use of cryogenic electron microscopy (cryo-EM) to provide high-resolution structures for synthetic peptide nanomaterials, we present here the use of cryo-EM to offer ca. 3 Å resolution of π-peptide nanomaterial assemblies, visualizing for the first time the nature of the intermolecular π-core electronic interactions responsible for energy transport through these supramolecular materials.

Group theory↗

Cryo-FIB for TEM Investigation of Soft Matter and Beam Sensitive Energy Materials

Primarily driven by structural biology, the rapid advances in cryogenic electron microscopy techniques are now being adopted and applied by materials scientists. Samples that inherently have electron transparency can be rapidly frozen (vitrified) in amorphous ice and imaged directly on a cryogenic transmission electron microscopy (cryo-TEM), however this is not the case for many important materials systems, which can consist of layered structures, embedded architectures, or be contained within a device. Cryogenic focused ion beam (cryo-FIB) lift-out procedures have recently been developed to extract intact regions and interfaces of interest, that can then be thinned to electron transparency and transferred to the cryo-TEM for characterization. Several detailed studies have been reported demonstrating the cryo-FIB lift-out procedure, however due to its relative infancy in materials science improvements are still required to ensure the technique becomes more accessible and routinely successful. Here, we review recent results on the preparation of cryo-TEM lamellae using cryo-FIB and show that the technique is broadly applicable to a range of soft matter and beam sensitive energy materials. We then present a tutorial that can guide the materials scientist through the cryo-FIB lift-out process, highlighting recent methodological advances that address the most common failure points of the technique, such as needle attachment, lift-out and transfer, and final thinning.

36 MATERIALS SCIENCE↗

Cryo-FIB for TEM Investigation of Soft Matter and Beam Sensitive Energy Materials

Primarily driven by structural biology, the rapid advances in cryogenic electron microscopy techniques are now being adopted and applied by materials scientists. Samples that inherently have electron transparency can be rapidly frozen (vitrified) in amorphous ice and imaged directly on a cryogenic transmission electron microscopy (cryo-TEM), however this is not the case for many important materials systems, which can consist of layered structures, embedded architectures, or be contained within a device. Cryogenic focused ion beam (cryo-FIB) lift-out procedures have recently been developed to extract intact regions and interfaces of interest, that can then be thinned to electron transparency and transferred to the cryo-TEM for characterization. Several detailed studies have been reported demonstrating the cryo-FIB lift-out procedure, however due to its relative infancy in materials science improvements are still required to ensure the technique becomes more accessible and routinely successful. Here, we review recent results on the preparation of cryo-TEM lamellae using cryo-FIB and show that the technique is broadly applicable to a range of soft matter and beam sensitive energy materials. We then present a tutorial that can guide the materials scientist through the cryo-FIB lift-out process, highlighting recent methodological advances that address the most common failure points of the technique, such as needle attachment, lift-out and transfer, and final thinning.

36 MATERIALS SCIENCE↗

Applications of cryogenics in electron microscopy

Description of research and development efforts which resulted in a high-voltage cryoelectron microscope system capable of consistent operation at 1.8 to 4.2 K. Attention is given to the design and operation of superconducting objective lenses providing enhanced resolution during longer exposure times at lower beam intensities (thus reducing radiation damage of specimens). A specific system described combines a closed-cycle superfluid helium refrigerator integrated with a modified 200 kV electron microscope. Consistent resolutions of 8 to 16 A are attained with significantly reduced radiation damage, contamination, and thermal noise in prolonged vibration-free examination of specimens at temperatures from 1.8 to 4.2 K. Applications in specific disciplines are discussed, including membrane ultrastructure, cryobiology, microelectronics, and general superconductivity research.

Fernandez-Moran, H.↗

Low-Cost Tracking Ground Terminal Designed to Use Cryogenically Cooled Electronics

A computer-controlled, tracking ground terminal will be assembled at the NASA Glenn Research Center at Lewis Field to receive signals transmitted by the Glenn's Direct Data Distribution (D3) payload planned for a shuttle flight in low Earth orbit. The terminal will enable direct data reception of up to two 622-megabits-per-second (Mbps) beams from the space-based, K-band (19.05-GHz) transmitting array at an end-user bit error rate of up to 10(exp -12). The ground terminal will include a 0.9-m-diameter receive-only Cassegrain reflector antenna with a corrugated feed horn incorporating a dual circularly polarized, K-band feed assembly mounted on a multiaxis, gimbaled tracking pedestal as well as electronics to receive the downlink signals. The tracking system will acquire and automatically track the shuttle through the sky for all elevations greater than 20 above the horizon. The receiving electronics for the ground terminal consist of a six-pole microstrip bandpass filter, a three-stage monolithic microwave integrated circuit (MMIC) amplifier, and a Stirling cycle cryocooler (1 W at 80 K). The Sterling cycle cryocooler cools the front end of the receiver, also known as the low-noise amplifier (LNA), to about 77 K. Cryocooling the LNA significantly increases receiver performance, which is necessary so that it can use the antenna, which has an aperture of only 0.9 m. The following drawing illustrates the cryoterminal.

Wald, Lawrence W.↗

Missing Wedge Completion via Unsupervised Learning with Coordinate Networks

Cryogenic electron tomography (cryoET) is a powerful tool in structural biology, enabling detailed 3D imaging of biological specimens at a resolution of nanometers. Despite its potential, cryoET faces challenges such as the missing wedge problem, which limits reconstruction quality due to incomplete data collection angles. Recently, supervised deep learning methods leveraging convolutional neural networks (CNNs) have considerably addressed this issue; however, their pretraining requirements render them susceptible to inaccuracies and artifacts, particularly when representative training data is scarce. To overcome these limitations, we introduce a proof-of-concept unsupervised learning approach using coordinate networks (CNs) that optimizes network weights directly against input projections. This eliminates the need for pretraining, reducing reconstruction runtime by 3–20× compared to supervised methods. Our in silico results show improved shape completion and reduction of missing wedge artifacts, assessed through several voxel-based image quality metrics in real space and a novel directional Fourier Shell Correlation (FSC) metric. Our study illuminates benefits and considerations of both supervised and unsupervised approaches, guiding the development of improved reconstruction strategies.

42 ENGINEERING↗

Power Electronics Being Developed for Deep Space Cryogenic Applications

Electronic circuits and systems designed for deep space missions need to operate reliably and efficiently in harsh environments that include very low temperatures. Spacecraft that operate in such cold environments carry a large number of heaters so that the ambient temperature for the onboard electronics remains near 20 C. Electronics that can operate at cryogenic temperatures will simplify system design and reduce system size and weight by eliminating the heaters and their associated structures. As a result, system development and launch cost will be reduced. At the NASA Glenn Research Center, an ongoing program is focusing on the development of power electronics geared for deep space low-temperature environments. The research and development efforts include electrical components design, circuit design and construction, and system integration and demonstration at cryogenic temperatures. Investigations are being carried out on circuits and systems that are targeted for use in NASA missions where low temperatures will be encountered: devices such as ceramic and tantalum capacitors, metal film resistors, semiconductor switches, magnetics, and integrated circuits including dc/dc converters, operational amplifiers, voltage references, and motor controllers. Test activities cover a wide range of device and circuit performance under simple as well as complex test conditions, such as multistress and thermal cycling. The effect of low-temperature conditions on the switching characteristics of an advanced silicon-on-insulator field effect transistor is shown. For gate voltages (VGS) below 2.6 V, drain currents at -190 C are lower than drain currents at room temperature (20 C).

Patterson, Richard L.↗

SISGR: The regulation of carbon fixation in plant and green algae: Rubisco activase and the origin of heat inactivation of CO 2 assimilation

Rubisco activase (Rca) is a critical AAA+ ATPase protein complex that remodels and promotes the Rubisco enzyme, a key player in photosynthetic performance and carbon fixation. The assembly and function of the Rca protein complex are regulated by a range of factors, including subunit concentration, nucleotide-binding states, thermal conditions, metal-ion coordination, and post-translational modifications, such as phosphorylation. Despite its importance in photosynthesis, the detailed molecular mechanisms underlying the regulation of plant Rca and how it activates Rubisco remain elusive. This project aims to bridge this knowledge gap by integrating sophisticated enzymology tools with single-molecule methods and high-resolution electron microscopy to elucidate the structure and function of plant Rca. Through these multiple approaches, we have systematically investigated how the activity of plant Rca is impacted by various factors, such as phosphorylation and metal-ion coordination. The Rca complex assembly/disassembly dynamics were captured using anti-Brownian electrokinetic (ABEL) trap-based measurements, providing unprecedented insight into its structural flexibility and diverse assembly states. Furthermore, the structural analysis of Rca through electron crystallography and single-particle cryogenic electron microscopy (cryo-EM) reveals novel assembly states of the spinach Rca, providing insight into the mechanistic action for Rubisco remodeling. By combining cutting-edge tools and approaches, this work uncovers critical aspects of Rca’s regulation and assembly, paving the way for a deeper understanding of its role in photosynthetic efficiency and the potential for enhancing carbon fixation in crops.

59 BASIC BIOLOGICAL SCIENCES↗

Monomer and dimer structures of cytochrome bo 3 ubiquinol oxidase from Escherichia coli

Abstract The Escherichia coli cytochrome bo 3 ubiquinol oxidase is a four‐subunit heme‐copper oxidase that serves as a proton pump in the E. coli aerobic respiratory chain. Despite many mechanistic studies, it is unclear whether this ubiquinol oxidase functions as a monomer, or as a dimer in a manner similar to its eukaryotic counterparts—the mitochondrial electron transport complexes. In this study, we determined the monomeric and dimeric structures of the E. coli cytochrome bo 3 ubiquinol oxidase reconstituted in amphipol by cryogenic electron microscopy single particle reconstruction (cryo‐EM SPR) to a resolution of 3.15 and 3.46 Å, respectively. We have discovered that the protein can form a dimer with C2 symmetry, with the dimerization interface maintained by interactions between the subunit II of one monomer and the subunit IV of the other monomer. Moreover, the dimerization does not induce significant structural changes in the monomers, except the movement of a loop in subunit IV (residues 67–74).

59 BASIC BIOLOGICAL SCIENCES↗

TES Detector Noise Limited Readout Using SQUID Multiplexers

The availability of superconducting Transition Edge Sensors (TES) with large numbers of individual detector pixels requires multiplexers for efficient readout. The use of multiplexers reduces the number of wires needed between the cryogenic electronics and the room temperature electronics and cuts the number of required cryogenic amplifiers. We are using an 8 channel SQUID multiplexer to read out one-dimensional TES arrays which are used for submillimeter astronomical observations. We present results from test measurements which show that the low noise level of the SQUID multiplexers allows accurate measurements of the TES Johnson noise, and that in operation, the readout noise is dominated by the detector noise. Multiplexers for large number of channels require a large bandwidth for the multiplexed readout signal. We discuss the resulting implications for the noise performance of these multiplexers which will be used for the readout of two dimensional TES arrays in next generation instruments.

Staguhn, J. G.↗