Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cryogenic optical systems and instruments IV; Proceedings of the Meeting, San Diego, CA, July 10-12, 1990

Consideration is given to cryogenic system design and optical technology; cryogenic instruments, sensors, and detectors; space cryogenic dewars and coolers; and cryogenic mechanisms, testing, and structures. Particular attention is given to mission optimization of the Space Infrared Telescope Facility (SIRTF), alternative aperture stop position designs for SIRTF, scaling laws for lightweight optics, evaluation of a far-infrared Ge:Ga multiplexed detector array, cryogenic limb array etalon spectrometer calibration, reliability growth of coolers for advanced optical systems and instruments, flight-qualified solid argon cooler for the BBXRT instrument, precision mechanisms for optical alignments at cryogenic temperatures, versatile cryogenic rotary-positioning systems, and optical alignments of the Cosmic Background Explorer observatory.

Melugin, Ramsey K.↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗

A Cryogenic Thermal Source for Detector Array Characterization

We describe the design, fabrication, and validation of a cryogenically compatible quasioptical thermal source for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure. The mold is fabricated using a hardened steel template produced via a wire electron discharge machining process. The absorptive mixture is bonded to a copper backplate enabling thermalization of the entire structure and measurement of the source temperature. Measurements indicate that the reflectance of the source is less than 0.001 across a spectral band extending from 75 to 330 gigahertz.

Chuss, David T.↗

Proceedings of the Third Infrared Detector Technology Workshop

This volume consists of 37 papers which summarize results presented at the Third Infrared Detector Technology Workshop, held February 7-9, 1989, at Ames Research Center. The workshop focused on infrared (IR) detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers on discrete IR detectors, cryogenic readouts, extrinsic and intrinsic IR arrays, and recent results from ground-based observations with integrated arrays were given. Recent developments in the second-generation Hubble Space Telescope (HST) infrared spectrometer and in detectors and arrays for the European Space Agency's Infrared Space Observatory (ISO) are also included, as are status reports on the Space Infrared Telescope Facility (SIRTF) and the Stratospheric Observatory for Infrared Astronomy (SOFIA) projects.

Mccreight, Craig R.↗

Cryogenic liquid-level detector

Detector is designed for quick assembly, fast response, and good performance under vibratory stress. Its basic parallel-plate open configuration can be adapted to any length and allows its calibration scale factor to be predicted accurately. When compared with discrete level sensors, continuous reading sensor was found to be superior if there is sloshing, boiling, or other disturbance.

Hamlet, J.↗

Detectors for Tomorrow's Instruments

Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor/normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provides a mechanism for high sensitivity detection of submillimeter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large scale superconducting detection systems are now being deployed. I will discuss the prospects for a new generation of instruments designed to take full advantage of the revolution in detector technology.

Moseley, Harvey↗

Technology development program for the Space Infrared Telescope Facility (SIRTF) science instruments

A coordinated technology program for the Space Infrared Telescope Facility (SIRTF) is described. The program encompasses detector technology, cryogenic mechanisms technology, and an adiabatic demagnetization refrigerator. Discrete detectors, detector arrays, detector readouts, and testing of engineering models under simulated flight environment conditions are considered. Several focal planes will be optimized at a particular wavelength range to make up over 247,000 detector pixels from about 1.8 to 1000 microns.

Ramos, Ruben↗

Use of mercuric iodide X-ray detectors with alpha backscattering spectrometers for space applications

The authors present X-ray fluorescence (XRF) spectra of different extraterrestrial samples taken with a mercuric iodide (HgI2) spectrometer inserted into an alpha backscattering instrument identical to that used in the Soviet Phobos mission. The results obtained with the HgI2 ambient temperature detector are compared with those obtained using an Si(Li) cryogenically cooled detector. Efforts to design an optimized instrument for space application are also described. The results presented indicate that the energy resolution and sensitivity of HgI2 detectors are adequate to meet the performance needs of a number of proposed space applications, particularly those in which cooled silicon X-ray detectors are impractical or even not usable, such as for the target science programs on geoscience opportunities for lunar surface, Mars surface, and other comet and planetary missions being planned by NASA and ESA.

Iwanczyk, J. S.↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗

RF Single Electron Transistor Readout Amplifiers for Superconducting Astronomical Detectors for X-Ray to Sub-mm Wavelengths

We report progress on using a new type of amplifier, the Radio-Frequency Single-Electron Transistor (RF-SET), to develop multi-channel sensor readout systems for fast and sensitive readout of high impedance cryogenic photodetectors such as Superconducting Tunnel Junctions and Single Quasiparticle Photon Counters. Although cryogenic, these detectors are desirable because of capabilities not other-wise attainable. However, high impedances and low output levels make low-noise, high-speed readouts challenging, and large format arrays would be facilitated by compact, low-power, on-chip integrated amplifiers. Well-suited for this application are RF-SETs, very high performance electrometers which use an rf readout technique to provide 100 MHz bandwidth. Small size, low power, and cryogenic operation allow direct integration with detectors, and using multiple rf carrier frequencies permits simultaneous readout of 20-50 amplifiers with a common electrical connection. We describe both the first 2-channel demonstration of this wavelength division multiplexing technique for RF-SETs, and Charge-Locked-Loop operation with 100 kHz of closed-loop bandwidth.

Stevenson, Thomas↗

Reliable Transport over SpaceWire for James Webb Space Telescope (JWST) Focal Plane Electronics (FPE) Network

NASA's James Webb Space Telescope (JWST) faces difficult technical and budgetary challenges to overcome before it is scheduled launch in 2010. The Integrated Science Instrument Module (ISIM), shares these challenges. The major challenge addressed in this paper is the data network used to collect, process, compresses and store Infrared data. A total of 114 Mbps of raw information must be collected from 19 sources and delivered to the two redundant data processing units across a twenty meter deployed thermally restricted interface. Further data must be transferred to the solid-state recorder and the spacecraft. The JWST detectors are kept at cryogenic temperatures to obtain the sensitivity necessary to measure faint energy sources. The Focal Plane Electronics (FPE) that sample the detector, generate packets from the samples, and transmit these packets to the processing electronics must dissipate little power in order to help keep the detectors at these cold temperatures. Separating the low powered front-end electronics from the higher-powered processing electronics, and using a simple high-speed protocol to transmit the detector data minimize the power dissipation near the detectors. Low Voltage Differential Signaling (LVDS) drivers were considered an obvious choice for physical layer because of their high speed and low power. The mechanical restriction on the number cables across the thermal interface force the Image packets to be concentrated upon two high-speed links. These links connect the many image packet sources, Focal Plane Electronics (FPE), located near the cryogenic detectors to the processing electronics on the spacecraft structure. From 12 to 10,000 seconds of raw data are processed to make up an image, various algorithms integrate the pixel data Loss of commands to configure the detectors as well as the loss of science data itself may cause inefficiency in the use of the telescope that are unacceptable given the high cost of the observatory. This combination of requirements necessitates a redundant, fault tolerant, high- speed, low mass, low power network with a low Bit error Rate(1E-9- 1E-12). The ISIM systems team performed many studies of the various network architectures that meeting these requirements. The architecture selected uses the Spacewire protocol, with the addition of a new transport and network layer added to implement end-to-end reliable transport. The network and reliable transport mechanism must be implemented in hardware because of the high average information rate and the restriction on the ability of the detectors to buffer data due to power and size restrictions. This network and transport mechanism was designed to be compatible with existing Spacewire links and routers so that existing equipment and designs may be leveraged upon. The transport layer specification is being coordinated with European Space Agency (ESA), Spacewire Working Group and the Consultative Committee for Space Data System (CCSDS) PlK Standard Onboard Interface (SOIF) panel, with the intent of developing a standard for reliable transport for Spacewire. Changes to the protocol presented are likely since negotiations are ongoing with these groups. A block of RTL VHDL that implements a multi-port Spacewire router with an external user interface will be developed and integrated with an existing Spacewire Link design. The external user interface will be the local interface that sources and sinks packets onto and off of the network (Figure 3). The external user interface implements the network and transport layer and handles acknowledgements and re-tries of packets for reliable transport over the network. Because the design is written in RTL, it may be ported to any technology but will initially be targeted to the new Actel Accelerator series (AX) part. Each link will run at 160 Mbps and the power will be about 0.165 Watt per link worst case in the Actel AX.

Rakow, Glenn↗

Advanced components for spaceborne infrared astronomy

The need for improved cryogenic components to be used in future spaceborne infrared astronomy missions was identified. Improved low noise cryogenic amplifiers operated with infrared detectors, and better cryogenic actuators and motors with extremely low power dissipation are needed. The feasibility of achieving technological breakthroughs in both of these areas was studied. An improved silicon junction field effect transistor (JFET) could be developed if: (1) high purity silicon; (2) optimum dopants; and (3) very high doping levels are used. The feasibility of a simple stepper motor equipped with superconducting coils is demonstrated by construction of such a device based on a standard commercial motor. It is found that useful levels of torque at immeasurably low power levels were achieved. It is concluded that with modest development and optimization efforts, significant performance gains is possible for both cryogenic preamplifiers and superconducting motors and actuators.

Davidson, A. W.↗

Performance and durability of HgI2 X-ray detectors for space missions

Considerable progress has been achieved recently in HgI2 detector fabrication technology and amplification electronics. An energy resolution of 198 eV (full width at half maximum) has been obtained for the Mn k-alpha line of 5.9 keV in a practical X-ray probe without the use of cryogenic cooling. Detectors prepared with Parylene-C encapsulation have demonstrated perfect reliability in two-year tests under high vacuum and temperature and bias cycling. Other HgI2 detectors have been used to demonstrate proton-radiation-damage resistance to levels of 10 to the 12 protons/sq cm at 10.7 MeV. It is concluded that HgI2 detectors are suitable for the ordinary requirements of energy dispersive detectors in X-ray spectroscopy systems.

Iwanczyk, J. S.↗

Superconducting Detectors Come of Age, or Ready to Leave the Lab

Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provide a mechanism for high sensitivity detection of submillil.neter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large-scale superconducting detection systems is now being deployed. Improved understanding of the operation of these detectors, combined with rapidly improving fabrication techniques, is quickly expanding the capability of these detectors. I will review the development and application of superconductor-based detectors, the ultimate limits to their performance, and consider prospects for their future applications. Continued advances promise to enable important new measurements in physics, and with appropriate advances in cryogenic infrastn~cturem, ay result in the use of these detectors in everyday monitoring applications.

Moseley, Samuel H.↗

Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and farinfrared astronomy. Each detector array is comprised of lambda/2 stepped impedance resonators, a 1.5μm thick silicon membrane, and 380μm thick silicon walls. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and are designed to have a surface impedance and filling fraction so as to match the impedance of free space. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.

far-infrared↗