Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Correlation Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cross-Correlation Analysis of Digital Speckle Photography

This paper describes new algorithms for processing noisy specklograms, which permit quantitative diagnostics of the microstructure of shock-wave flows with a subpicosecond accuracy with the use of statistical analysis of numerically registered speckle fields disturbed by the refraction in the investigated flows. The software developed by us permits reconstructing up to 10,000 vector angles of probe radiation deflection in a two-dimensional region of size 20 × 30 mm{sup 2} in imaging a speckle field with optical magnification M = 1.

42 ENGINEERING↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

Correlative Analysis of GRBs detected by Swift and Suzaku-WAM

Since most gamma-ray bursts (GRBs) have a peak energy (Epeak) above the energy range (15-150 keV) of the Burst Alert Telescope (BAT) on Swift, a full understanding of the prompt emission from Swift GRBs requires spectral fits over as broad an energy range as possible. This can be done for bursts which are simultaneously detected by Swift BAT and the Suzaku Wide-band All-Sky Monitor (WAM), which covers the energy range from 50-5000 keV. Since the launch of Suzaku in July 2005, there have been 33 gamma-ray bursts (GRBs) which have triggered both Swift and WAM. A joint BAT-WAM team has cross-calibrated the two instruments using GRBs, and we are now able to perform joint fits on these bursts to determine spectral parameters including Epeak. The results of broad spectral fits allows us to understand the distribution of Epeak for Swift bursts and to calibrate Epeak estimators when Epeak is within the BAT energy range. For those bursts with spectroscopic redshifts, we can calculate the isotropic energy and study various correlations between Epeak and other global burst parameters. Here we present preliminary results of joint Swift/BAT-Suzaku/WAM spectral fits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlation Analysis of TEM Images of Nanocrystal Molecules

Quantitative characterizataion of images of naocrystals and nanostructures is a challenging but important task. The development and optimization of methods for the construction of complex nanostructures rely on imaging techniques. Computer programs were developed to quantify TEM images of nanocrystal/DNA nanostructures, and results are presented for heterodimers annd trimers of gold nanocrystals. The programs presented here have also been used to analyze more complex trimers and tetramers linked by branched DNA, as well as for structures made from attaching gold nanocrystals to CdSe/ZnS core-shell quantum dots. This work has the additional goal of enabling others to quickly and easily adapt the methods for their own use.

36 MATERIALS SCIENCE↗

Oxidation potentials of phenols and anilines: correlation analysis of electrochemical and theoretical values

As described in the main text, we classified our voltammograms into four types. For phenols, most compounds were type I or type II, except four phenols that were type III (4-nitrophenol, 4-cyanophenol, DNOC, and 4-hydroxyacetphenone); and two phenols that were type IV (4-aminophenol and dopamine). Almost all of the compounds gave the same type by SCV and SWV, except for 2,4-dinitrophenol (whose current went up and down and therefore could be considered a type II or III), 4-cyanophenol (which fell into a type III for SCV, but whose current went up and down in SWV (type II or III)), and 4-hydroxyacetophenone (which was a type III in SCV, but a type II in SWV). The majority of the anilines were type I except for p-toluidine (type II) and 4-methyl-3-nitroaniline and 2-methoxy-5-nitroaniline (both were type I for SWV, but for SCV fell into type III and type II respectively).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cross-instrument Analysis Correlation Software

This program has been designed to assist with the tracking of a sample from one analytical instrument to another such as SEM, microscopes, micro x-ray diffraction and other instruments where particular positions/locations on the sample are examined, photographed, etc. The software is designed to easily enter the position of fiducials and locations of interest such that in a future session in the same of different instrument the positions of interest can be re-found through using the known location fiducials in the current and reference session to transform the point into the current sessions coordinate system. The software is dialog box driven guiding the user through the necessary data entry and program choices. Information is stored in a series of text based extensible markup language (XML) files.

McJunkin, TimothyR.↗