Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Resilience Strategies to Ensure Water Supply Continuity During Extended Grid Outages

The towns of Edgartown, Oak Bluffs and Tisbury, on the island of Martha’s Vineyard, MA, are concerned about the effect of prolonged grid outages on continuity of their water supply. Water pumping stations operated by the water utilities that currently serve each of the towns currently have backup power generation that can support water delivery for up to one week during peak water demand periods. Sandia advised on options to extend water supply to two weeks.

Mammoli, Andrea Alberto [Sandia National Laborator

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

A Cryogenic Seven-Element HEMT Front End for DSS 13

A cryogenically cooled Ka-band (33.6-GHz), seven-element front-end array for the DSN was built and tested. This system uses seven high electron mobility transistor (HEMT) low-noise amplifiers cooled by a two-stage closed-cycle refrigerator. All system components from the polarizers to the output isolators are cooled to a physical temperature between 18 and 35 K. The noise temperatures of the individual elements range from 64 to 84 K over a 2.75-GHz bandwidth.

J Bowen

Water-Moderated Reactor Concept

Because of the importance of nuclear rockets for manned planetary flight, the Lewis Research Center has been studying alternate nuclear rocket concepts that have the potential for meeting the high performance requirements of these missions. Lewis has concentrated its advanced nuclear rocket research program on a tungsten-water-moderated concept. The purpose of this presentation is to describe this concept and give a brief resume of some of the work that has been done in support of it.

Frank E Rom

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

The Detection of Water Vapor on Mars

We have found eleven weak lines of water vapor on a high dispersion near-infrared spectrogram of Mars taken at the coudè focus of the Mount Wilson 100-inch reflector on April 12/13,1963. We exposed 43 hours on ammoniated IV-N emulsion with a dispersion of 5.6 A/mm; the plate is well exposed at the poles and somewhat overexposed at the center of the planet’s disk. The Martian H 2 O lines in the X 8200 water-vapor band are displaced 0.42 A longward of their telluric counterparts due to the relative velocities of the earth and Mars: AV = +15 km/sec on that date. The Martian lines are strongest over the poles of the planet-we set the spectrograph slit daost north-south to cover both polar regions. This apparent polar strengthening of the Martian H 2 O lines is at least partially due to the increased air mass through the line of sight to high latitudes.

MARS /PLANET/

Three-Dimensional, Multi-Phase Unsteady Flow of Water Undergoing Multiple Flow Regimes (Free Surface, Droplet, and Fluid Film)

Upgrades to the Mobile Launcher Rainbird nozzles were implemented for the Artemis II launch to increase water flow rates and improve the mobile launcher deck water coverage while minimizing the water throw distance to avoid impacting the Space Launch System (SLS) rocket nozzles. This analysis describes the use of a three-dimensional, multi-phase, free surface transient computational fluid dynamics (CFD) model to simulate the water flowing out through the Rainbird nozzle and ensure compliance with current Artemis requirements. Flow rates, pressures, velocities, nozzle throw distances and coverage areas were analyzed to ensure that system requirements are met. The completed results were used to make necessary modifications to the Ignition Overpressure Protection and Sound Suppression (IOP/SS) system Rainbird design by reshaping the nozzle used in the system.

CFD