Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Container Ship”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Production, isolation, and shipment of clinically relevant quantities of astatine-211: A simple and efficient approach to increasing supply

The alpha emitter astatine-211 ( 211 At) is a promising candidate for cancer treatment based on Targeted Alpha (α) Therapy (TAT). A small number of facilities, distributed across the United States, are capable of accelerating α-particle beams to produce 211 At. However, challenges remain regarding strategic methods for shipping 211 At in a form adaptable to advanced radiochemistry reactions and other uses of the radioisotope. Purpose: Our method allows shipment of 211 At in various quantities in a form convenient for further radiochemistry. Procedures: For this study, a 3-octanone impregnated Amberchrom® CG300M resin bed in a column cartridge was used to separate 211 At from the bismuth matrix on site at the production accelerator (Texas A&M) in preparation for shipping. Aliquots of 6 M HNO 3 containing up to ≈2.22 GBq of 211 At from the dissolved target were successfully loaded and retained on columns. Exempt packages (<370 MBq) were shipped to a destination radiochemistry facility, University of Texas MD Anderson Cancer Center, in the form of a convenient air-dried column. Type A packages have been shipped overnight to University of Alabama at Birmingham. Main findings: Air-dried column hold times of various lengths did not inhibit simple and efficient recovery of 211 At. Solution eluted from the column was sufficiently high in specific activity to successfully radiolabel a model compound, 4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)aniline (1), with 211 At. The method to prepare and ship 211 At described in this manuscript has also been used to ship larger quantities of 211 At a greater distance to University of Alabama at Birmingham. Principal conclusions: The successful proof of this method paves the way for the distribution of 211 At from Texas A&M University to research institutions and clinical oncology centers in Texas and elsewhere. Finally, use of this simple method at other facilities has the potential increase the overall availability of 211 At for preclinical and clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Container Evaluation: Analysis of the Swagelok Knuckle with Viewport as an Approved Hermetically Sealed Inner Container

This report outlines the results from the water ingress test, helium leak test and additional atmosphere testing for the Swagelok knuckle with viewport container further referred to as the SKV. This container is constructed from a standard union vacuum fitting, 1.33” conflat to 0.5” male VCR, a 1.33” conflat fused silica lensed viewport fitting, and a 0.5 inch VCR cap. The primary intended use of this container is to store Pu metal samples in the vault for a time interval exceeding 40 years. The samples need to be contained in an air free environment to ensure that the material does not oxidize over time. The container viewport is a critical design feature that will help the operators visually inspect and evaluate the state of the metal samples prior to opening the container. These containers are advertised as leak tight, but experimental tests were performed to test the water resistant criteria and the gas leaking criteria set forth by the TA-55 Criticality Safety Program. The results of the water ingress test show that the container is water-tight, with no signs of water penetrating the container within the required guidelines outlined in TA55-AP-522. The preliminary He leak test performed demonstrate that the conflat window port and VCR cap are able to maintain a hermetic seal. Additionally, all containers will be He leak tested independently by the manufacturer prior to shipping to LANL. A third voluntary test was added to assess the container’s ability to hold atmosphere, with successful results indicating the container is able to hold inert atmosphere to prevent lanthanum metal oxidation. It is the conclusion of the authorsthat there is enough evidence through the test conducted and outlined within this document that the proposed container meets the definition of a water-tight container, and it is able to provide a hermetic seal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing Greater Houston's Aerosol by Air Mass During TRACER

During the TRacking Aerosol and Convection interaction ExpeRiment (TRACER), a suite of aerosol and cloud measurements were made using the Texas A&M Rapid Onsite Atmospheric Measurement Van (ROAM-V) mobile instrument platform. Joint ROAM-V/radiosonde deployments focused on sampling polluted marine and continental air masses to understand summertime convection along and across the sea-breeze front as it propagated through Houston. The polluted marine air mass at Seawolf Park, Galveston, TX was defined by two characteristic aerosol populations. Although the background total particle concentrations averaged 2,500 cm −3 , the air mass was also influenced by frequent but irregular periods of ship emission with significantly higher aerosol concentrations at times exceeding 34,000 cm −3 . Ship emission influenced periods, typically lasting <10 min, contained smaller, less hygroscopic particles resulting in a 69% relative decline in cloud condensation nuclei (CCN) activated fraction at 1% supersaturation compared to background periods. Measurements in continental air masses northwest of Houston revealed an average aerosol concentration of 5,208 cm −3 with a κ value near 0.1 reasonably describing the CCN population, independent of particle size. In continental air masses, substantial differences in particle size and CCN activation over small distances (<42 miles between sites) suggest considerable site-to-site variability in addition to the expected day-to-day differences. This small-scale variability makes it difficult to generalize continental air mass aerosol properties. Both coastal and inland locations had effective ice nucleating particles, but inland deployments observed the warmest nucleation temperature at −15.6°C compared to −17.8°C close to the coast. These measurements can reduce uncertainties in regional convection allowing models to improve understanding of aerosol-cloud interactions.

54 ENVIRONMENTAL SCIENCES↗

Analytical Results for Prepared UIUC F 7 LiNaK

Source materials including 275 g of 7 LiF-NaF-KF (46.5-11.5-42.0 mol %) and 10 g each of several reagent salts were prepared at Argonne for shipment to the University of Illinois at Urbana Champaign. The F 7 LiNaK was packaged in a single jar and reagent salts were placed in small vials. The mass of each shipped salt is listed in Table 1. This report contains details of the preparation procedure and results of elemental composition measurements using inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) and phase analyses using X-ray diffraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Inactivation of highly transmissible livestock and avian viruses including influenza A and Newcastle disease virus for molecular diagnostics

There is a critical need for an inactivation method that completely inactivates pathogens at the time of sample collection while maintaining the nucleic acid quality required for diagnostic PCR testing. This inactivation method is required to alleviate concerns about transmission potential, minimize shipping complications and cost, and enable testing in lower containment laboratories, thereby enhancing disease diagnostics through improved turn-around time. This study evaluated a panel of 10 surrogate viruses that represent highly pathogenic animal diseases. These results showed that a commercial PrimeStore® molecular transport media (PSMTM) completely inactivated all viruses tested by >99.99%, as determined by infectivity and serial passage assays. However, the detection of viral nucleic acid by qRT-PCR was comparable in PSMTM and control-treated conditions. These results were consistent when viruses were evaluated in the presence of biological material such as sera and cloacal swabs to mimic diagnostic sample conditions for non-avian and avian viruses, respectively. The results of this study may be utilized by diagnostic testing laboratories for highly pathogenic agents affecting animal and human populations. These results may be used to revise guidance for select agent diagnostic testing and the shipment of infectious substances.

60 APPLIED LIFE SCIENCES↗

Design and Demonstration of a NH3-Fueled Two-Stroke Uniflow Engine for Greenhouse Gas Reduction

The maritime shipping industry is growing increasingly interested in both low and non-carbon-containing fuels to meet future greenhouse gas emission targets. Specifically of interest is ammonia, as it has a relatively high volumetric energy density compared to other future fuels, such as hydrogen, making it more economical to transport. The robust engine architecture of low-speed two-stroke marine engines makes them an ideal candidate for ammonia fuel, overcoming many of the issues surrounding its poor ignitability and low flame speed. If emissions and fueling system challenges can be addressed, retrofits of current low-speed two-stroke dual-fuel engines represent a viable pathway for bringing ammonia engines to market. This study explores these technical hurdles by describing the design, analysis, and experimental validation of a single cylinder research engine converted to operate on ammonia fuel. The engine is a reduced-scale uniflow two-stroke marine engine with two previous hardware configurations available – diesel and high-pressure CNG dual-fuel. A concept study was used to evaluate possible ammonia-fueled engine architectures and the associated tradeoffs and design considerations. With the chosen architecture, low-pressure dual fuel, 1D and 3D analysis tools were used to inform hardware selection and to determine hardware configurations which minimized ammonia-slip. In addition to these considerations the hardware and engine configuration were designed to provide a versatile and robust testing platform. This includes options to test both gaseous and liquid ammonia injection, as well as a wide range of performance parameters such as AFR, swirl, valve timing, SOI, and many others. Design constraints imposed by the existing engine hardware necessitated an iterative loop between design and analysis toolsets, ultimately converging on a final design for the ammonia-conversion hardware. The engine was rebuilt with the new hardware and evaluated in an engine test cell. A new control strategy developed and flashed onto a prototyping electronic control unit allowed for full control over all engine parameters. An initial calibration was developed, providing test data for validation of the engine 1D and 3D models. The impact of the design choices on engine operability and the ability to meet program targets is discussed as well as opportunities for further optimization of the ammonia-conversion hardware, informed by the validated models.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

WFIP3 - BARG site - NREL Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from NREL's profiling lidar (Windcube v2.1) at the WFIP3 NOAA SHIP site. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution.

17 WIND ENERGY↗

Sounding System / Raw Data

This dataset contains twice or four times daily radiosonde observations of the atmosphere from the quarterly LTER ship transects. Variables include atmospheric pressure, temperature, relative humidity, wind speed, wind direction, north wind speed, and east wind speed. Note that variables are a function of height.

17 WIND ENERGY↗

Development of a Helical Closure for Radioactive Material Shipping Packages

The Savannah River National Laboratory (SRNL) Packaging Technology group proposed a closure design for the outer packaging of a prototype Type B shipping package being developed for the Department of Energy (DOE). The closure design provides an efficient means of securing the containment vessel (CV) within the radioactive material packaging. This design has a simplified operation, requires less components, and less maintenance when compared to current radioactive material package closure methods. This paper will review and discuss the materials, designs, processes, and testing activities that were considered and pursued in the development of the novel closure for the outer packaging of new radioactive material shipping packages.

Housley, William M. [Savannah River National Labor↗

Irradiation-assisted Stress Corrosion Cracking of PWRirradiated Type 347 Stainless Steel (NSUF CINR 19-16567)

This document serves as the final report for NSUF Project 19-16567 (Reference 1) and its supporting contracts (References 2 and 3). It documents completion of testing of specimens fabricated as previously described in Reference 4. At a high level, the purpose of the testing is to generate data to support continued operation of light water reactors (LWR) and provide further understanding of irradiation-assisted stress corrosion crack (IASCC) initiation in baffle-former bolt materials. Baffle-former bolts that had been extracted from commercial pressurized water reactors (PWRs) were machined into miniature 4-point bend specimens and TEM samples at the Westinghouse Churchill Site hot cell facility. These samples were then shipped to the University of Michigan to undergo IASCC initiation testing in simulated PWR primary coolant containing either LiOH or KOH additions. Overall, 15 samples were tested, 8 in water with KOH additions and 7 in water with LiOH additions, until indications of cracking were observed. Crack initiation stress was similar in both water environments at 50-60% of the irradiated yield stress. Post-test examination of the cracking sites, including scanning electron microscopy and transmission electron microscopy, demonstrated that the crack initiation mechanism and crack initiation rates were similar between the two different water chemistries. A grain boundary oxidation and oxide fracture mechanism was observed to be responsible for crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

arsclwacr1kolliasshp.c0

arsclwacr1kolliasshp provides cloud boundaries and best-estimate time-height fields of uncalibreated radar moments on a ship. The uncalibreated WACR measurements are combined with observations from the micropulse lidar, ceilometer. The asiarsclwacrbnd1kolliasM1.c0 datastream contains cloud base and cloud layer boundaries.

54 ENVIRONMENTAL SCIENCES↗

WFIP3 - NOAA SHIP site - NREL Ceilometer (Vaisala CL51) / Derived Data

NOAA SHIP ceilometer: netCDF L3 data files have level 3 (L3) data that have gone through the calculation service and contain all the data from the algorithms, including mixing layer height values, and quality index data. L3 default files contain L3 data that use the default preset for a live plot. File naming schema: L3_DEFAULT_ _YYYYMMDDHHMM_ _ .nc Name Description: L3 Identification of the data level DEFAULT Identification of the L3 file type CUSTOM OFFLINE STATION_NUMBER WMO station number, if defined YYYYMMDDHHMM UTC time ParameterKey Identification of the advanced algorithm settings. See the table below for an explanation. FREE_FORMAT File suffix, if defined

17 WIND ENERGY↗

Cone Penetration Tests at the PacWave South Test Site

This ZIP archive contains cone penetration test data from the PacWave South Test Site. The data were collected in September 2023 aboard the ship Seacor Lee operating out of the Port of Newport, OR. The tests were performed by ConeTec using an AP van den Berg ROSON-100. The cone itself was a standard u2-type, 10 cm^2. A total of 22 soundings were performed.

16 TIDAL AND WAVE POWER↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

FY2023 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗